Skip to main content
Erschienen in: Documenta Ophthalmologica 3/2020

13.05.2020 | Original Research Article

Comparison of the performance of six stimulus paradigms in visual acuity assessment based on steady-state visual evoked potentials

verfasst von: Xiaowei Zheng, Guanghua Xu, Yifan Wu, Yunyun Wang, Chenghang Du, Yongcheng Wu, Sicong Zhang, Chengcheng Han

Erschienen in: Documenta Ophthalmologica | Ausgabe 3/2020

Einloggen, um Zugang zu erhalten

Abstract

Purpose

There are several stimulus paradigms used in objective visual acuity assessment based on steady-state visual evoked potentials (SSVEPs). The aim of this study was to explore the difference and performance of common used six stimulus paradigms (reverse vertical sinusoidal gratings, reverse horizontal sinusoidal gratings, reverse vertical square-wave gratings, brief-onset vertical sinusoidal gratings, reversal checkerboards and oscillating expansion–contraction concentric-rings) of SSVEP acuity assessment.

Methods

We tested subjective visual acuity both by tumbling E and Freiburg Visual Acuity and Contrast Test (FrACT) in 11 subjects. SSVEPs were induced by 11 spatial frequencies for each paradigm, and then a threshold determination criterion was used to define the objective SSVEP visual acuity.

Results

After SSVEP signal analysis, we found there was difference in SSVEP response of harmonic components and no difference in sensitive electrode placement for the six paradigms. We selected six electrodes (PO3, POz, PO4, O1, Oz and O2) as the sensitive electrodes to use in data processing for each paradigm. The results showed that except for brief-onset vertical sinusoidal gratings, the correlation and agreement between objective SSVEP and subjective FrACT acuity were all quite good, demonstrating good performance in acuity detection for the rest five paradigms.

Conclusion

Except for brief-onset vertical sinusoidal gratings, all the five stimulus paradigms of reverse vertical sinusoidal gratings, reverse horizontal sinusoidal gratings, reverse vertical square-wave gratings, reversal checkerboards and oscillating expansion–contraction concentric-rings performed quite well in objective SSVEP visual acuity assessment.
Literatur
2.
Zurück zum Zitat Bourne RRA, Flaxman SR, Braithwaite T, Cicinelli MV, Das A, Jonas JB, Keeffe J, Kempen JH, Leasher J, Limburg H, Naidoo K, Pesudovs K, Resnikoff S, Silvester A, Stevens GA, Tahhan N, Wong TY, Taylor HR, Vision Loss Expert G (2017) Magnitude, temporal trends, and projections of the global prevalence of blindness and distance and near vision impairment: a systematic review and meta-analysis. Lancet Glob Health 5(9):e888–e897. https://doi.org/10.1016/S2214-109X(17)30293-0CrossRefPubMed Bourne RRA, Flaxman SR, Braithwaite T, Cicinelli MV, Das A, Jonas JB, Keeffe J, Kempen JH, Leasher J, Limburg H, Naidoo K, Pesudovs K, Resnikoff S, Silvester A, Stevens GA, Tahhan N, Wong TY, Taylor HR, Vision Loss Expert G (2017) Magnitude, temporal trends, and projections of the global prevalence of blindness and distance and near vision impairment: a systematic review and meta-analysis. Lancet Glob Health 5(9):e888–e897. https://​doi.​org/​10.​1016/​S2214-109X(17)30293-0CrossRefPubMed
14.
Zurück zum Zitat Tyler CW, Apkarian P, Levi DM, Nakayama K (1979) Rapid assessment of visual function: an electronic sweep technique for the pattern visual evoked potential. Invest Ophthalmol Vis Sci 18(7):703–713PubMed Tyler CW, Apkarian P, Levi DM, Nakayama K (1979) Rapid assessment of visual function: an electronic sweep technique for the pattern visual evoked potential. Invest Ophthalmol Vis Sci 18(7):703–713PubMed
Metadaten
Titel
Comparison of the performance of six stimulus paradigms in visual acuity assessment based on steady-state visual evoked potentials
verfasst von
Xiaowei Zheng
Guanghua Xu
Yifan Wu
Yunyun Wang
Chenghang Du
Yongcheng Wu
Sicong Zhang
Chengcheng Han
Publikationsdatum
13.05.2020
Verlag
Springer Berlin Heidelberg
Erschienen in
Documenta Ophthalmologica / Ausgabe 3/2020
Print ISSN: 0012-4486
Elektronische ISSN: 1573-2622
DOI
https://doi.org/10.1007/s10633-020-09768-x

Weitere Artikel der Ausgabe 3/2020

Documenta Ophthalmologica 3/2020 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Ophthalmika in der Schwangerschaft

Die Verwendung von Ophthalmika in der Schwangerschaft und Stillzeit stellt immer eine Off-label-Anwendung dar. Ein Einsatz von Arzneimitteln muss daher besonders sorgfältig auf sein Risiko-Nutzen-Verhältnis bewertet werden. In der vorliegenden …

Operative Therapie und Keimnachweis bei endogener Endophthalmitis

Vitrektomie Originalie

Die endogene Endophthalmitis ist eine hämatogen fortgeleitete, bakterielle oder fungale Infektion, die über choroidale oder retinale Gefäße in den Augapfel eingeschwemmt wird [ 1 – 3 ]. Von dort infiltrieren die Keime in die Netzhaut, den …

Bakterielle endogene Endophthalmitis

Vitrektomie Leitthema

Eine endogene Endophthalmitis stellt einen ophthalmologischen Notfall dar, der umgehender Diagnostik und Therapie bedarf. Es sollte mit geeigneten Methoden, wie beispielsweise dem Freiburger Endophthalmitis-Set, ein Keimnachweis erfolgen. Bei der …

So erreichen Sie eine bestmögliche Wundheilung der Kornea

Die bestmögliche Wundheilung der Kornea, insbesondere ohne die Ausbildung von lichtstreuenden Narben, ist oberstes Gebot, um einer dauerhaften Schädigung der Hornhaut frühzeitig entgegenzuwirken und die Funktion des Auges zu erhalten.   

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.