Abstract

Purpose

The purpose of this study was to compare the midterm outcomes between fixed and mobile ultra-congruent (UC) bearings in total knee arthroplasty (TKA).

Methods

This is a retrospective matched-pairs case–control study of patients who underwent primary navigation-assisted TKA with a minimum 5-year follow-up. A total of 182 cases involved the fixed UC bearing system as Group 1 and 101 cases involved mobile UC bearing system group as Group 2. After 1:1 matching, 73 knees in each group were enrolled. Clinical and radiographic outcomes were evaluated.

Results

The overall survival was 143 of 146 cases (97.9 %) at final follow-up, and 72 of 73 cases (96.3 %) in Group 1 and 71 of 73 cases (95.8 %) in Group 2 at final follow-up based on an endpoint of revision surgery. The reasons of revision TKA were periprosthetic fracture in Group 1, infection and bearing dislocation in Group 2. There was no statistical difference in Hospital for Special Surgery (HSS) scores, Knee Society Scores (KSS), WOMAC index score evaluations between groups.

Conclusions

This study demonstrated that the fixed-bearing UC prosthesis could provide satisfactory performance compared with that of the mobile-bearing UC prosthesis with minimum 5-year follow-up. The fixed-bearing UC prosthesis could be considered in navigation-assisted TKA with theoretical advantages of UC design.

Level of evidence

IV.
Literatur
1.
Zurück zum Zitat Bailey O, Ferguson K, Crawfurd E, James P, May PA, Brown S, Blyth M, Leach WJ (2015) No clinical difference between fixed- and mobile-bearing cruciate-retaining total knee arthroplasty: a prospective randomized study. Knee Surg Sports Traumatol Arthrosc 23:1653–1659CrossRefPubMed Bailey O, Ferguson K, Crawfurd E, James P, May PA, Brown S, Blyth M, Leach WJ (2015) No clinical difference between fixed- and mobile-bearing cruciate-retaining total knee arthroplasty: a prospective randomized study. Knee Surg Sports Traumatol Arthrosc 23:1653–1659CrossRefPubMed
2.
Zurück zum Zitat Bauwens K, Matthes G, Wich M, Gebhard F, Hanson B, Ekkernkamp A, Stengel D (2007) Navigated total knee replacement. A meta-analysis. J Bone Joint Surg Am 89:261–269PubMed Bauwens K, Matthes G, Wich M, Gebhard F, Hanson B, Ekkernkamp A, Stengel D (2007) Navigated total knee replacement. A meta-analysis. J Bone Joint Surg Am 89:261–269PubMed
3.
Zurück zum Zitat Bistolfi A, Lee GC, Deledda D, Rosso F, Berchialla P, Crova M, Massazza G (2014) NexGen LPS mobile bearing total knee arthroplasty: 10-year results. Knee Surg Sports Traumatol Arthrosc 22:1786–1792CrossRefPubMed Bistolfi A, Lee GC, Deledda D, Rosso F, Berchialla P, Crova M, Massazza G (2014) NexGen LPS mobile bearing total knee arthroplasty: 10-year results. Knee Surg Sports Traumatol Arthrosc 22:1786–1792CrossRefPubMed
4.
Zurück zum Zitat Blunn GW, Joshi AB, Minns RJ, Lidgren L, Lilley P, Ryd L, Engelbrecht E, Walker PS (1997) Wear in retrieved condylar knee arthroplasties. A comparison of wear in different designs of 280 retrieved condylar knee prostheses. J Arthroplasty 12:281–290CrossRefPubMed Blunn GW, Joshi AB, Minns RJ, Lidgren L, Lilley P, Ryd L, Engelbrecht E, Walker PS (1997) Wear in retrieved condylar knee arthroplasties. A comparison of wear in different designs of 280 retrieved condylar knee prostheses. J Arthroplasty 12:281–290CrossRefPubMed
5.
Zurück zum Zitat Carothers JT, Kim RH, Dennis DA, Southworth C (2011) Mobile-bearing total knee arthroplasty: a meta-analysis. J Arthroplasty 26:537–542CrossRefPubMed Carothers JT, Kim RH, Dennis DA, Southworth C (2011) Mobile-bearing total knee arthroplasty: a meta-analysis. J Arthroplasty 26:537–542CrossRefPubMed
6.
Zurück zum Zitat Chavoix JB (2013) Functionality and safety of an ultra-congruent rotating platform knee prosthesis at 5.6 years: more than 5-year follow-up of the e.motion UC-TKA. Open Orthop J 7:152–157CrossRefPubMedPubMedCentral Chavoix JB (2013) Functionality and safety of an ultra-congruent rotating platform knee prosthesis at 5.6 years: more than 5-year follow-up of the e.motion UC-TKA. Open Orthop J 7:152–157CrossRefPubMedPubMedCentral
7.
Zurück zum Zitat Cheng T, Pan XY, Mao X, Zhang GY, Zhang XL (2012) Little clinical advantage of computer-assisted navigation over conventional instrumentation in primary total knee arthroplasty at early follow-up. Knee 19:237–245CrossRefPubMed Cheng T, Pan XY, Mao X, Zhang GY, Zhang XL (2012) Little clinical advantage of computer-assisted navigation over conventional instrumentation in primary total knee arthroplasty at early follow-up. Knee 19:237–245CrossRefPubMed
8.
Zurück zum Zitat Cheng T, Zhang G, Zhang X (2011) Imageless navigation system does not improve component rotational alignment in total knee arthroplasty. J Surg Res 171:590–600CrossRefPubMed Cheng T, Zhang G, Zhang X (2011) Imageless navigation system does not improve component rotational alignment in total knee arthroplasty. J Surg Res 171:590–600CrossRefPubMed
9.
Zurück zum Zitat Cheng T, Zhao S, Peng X, Zhang X (2012) Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials? Knee Surg Sports Traumatol Arthrosc 20:1307–1322CrossRefPubMed Cheng T, Zhao S, Peng X, Zhang X (2012) Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials? Knee Surg Sports Traumatol Arthrosc 20:1307–1322CrossRefPubMed
10.
Zurück zum Zitat Cho SD, Youm YS, Park KB (2011) Three- to six-year follow-up results after high-flexion total knee arthroplasty: can we allow passive deep knee bending? Knee Surg Sports Traumatol Arthrosc 19:899–903CrossRefPubMed Cho SD, Youm YS, Park KB (2011) Three- to six-year follow-up results after high-flexion total knee arthroplasty: can we allow passive deep knee bending? Knee Surg Sports Traumatol Arthrosc 19:899–903CrossRefPubMed
11.
Zurück zum Zitat Dennis DA, Komistek RD (2006) Mobile-bearing total knee arthroplasty: design factors in minimizing wear. Clin Orthop Relat Res 452:70–77CrossRefPubMed Dennis DA, Komistek RD (2006) Mobile-bearing total knee arthroplasty: design factors in minimizing wear. Clin Orthop Relat Res 452:70–77CrossRefPubMed
12.
Zurück zum Zitat Dennis DA, Komistek RD, Mahfouz MR, Outten JT, Sharma A (2005) Mobile-bearing total knee arthroplasty: do the polyethylene bearings rotate? Clin Orthop Relat Res 440:88–95CrossRefPubMed Dennis DA, Komistek RD, Mahfouz MR, Outten JT, Sharma A (2005) Mobile-bearing total knee arthroplasty: do the polyethylene bearings rotate? Clin Orthop Relat Res 440:88–95CrossRefPubMed
13.
Zurück zum Zitat Engh GA, Zimmerman RL, Parks NL, Engh CA (2009) Analysis of wear in retrieved mobile and fixed bearing knee inserts. J Arthroplasty 24:28–32CrossRefPubMed Engh GA, Zimmerman RL, Parks NL, Engh CA (2009) Analysis of wear in retrieved mobile and fixed bearing knee inserts. J Arthroplasty 24:28–32CrossRefPubMed
14.
Zurück zum Zitat Ewald FC (1989) The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res 248:9–12 Ewald FC (1989) The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res 248:9–12
15.
Zurück zum Zitat Geiger F, Mau H, Kruger M, Thomsen M (2008) Comparison of a new mobile-bearing total knee prosthesis with a fixed-bearing prosthesis: a matched pair analysis. Arch Orthop Trauma Surg 128:285–291CrossRefPubMed Geiger F, Mau H, Kruger M, Thomsen M (2008) Comparison of a new mobile-bearing total knee prosthesis with a fixed-bearing prosthesis: a matched pair analysis. Arch Orthop Trauma Surg 128:285–291CrossRefPubMed
16.
Zurück zum Zitat Goebel D, Schultz W (2012) The Columbus Knee System: 4-year results of a new deep flexion design compared to the NexGen full flex implant. Arthritis 2012:213817CrossRefPubMedPubMedCentral Goebel D, Schultz W (2012) The Columbus Knee System: 4-year results of a new deep flexion design compared to the NexGen full flex implant. Arthritis 2012:213817CrossRefPubMedPubMedCentral
17.
Zurück zum Zitat Grupp TM, Kaddick C, Schwiesau J, Maas A, Stulberg SD (2009) Fixed and mobile bearing total knee arthroplasty—influence on wear generation, corresponding wear areas, knee kinematics and particle composition. Clin Biomech (Bristol, Avon) 24:210–217CrossRef Grupp TM, Kaddick C, Schwiesau J, Maas A, Stulberg SD (2009) Fixed and mobile bearing total knee arthroplasty—influence on wear generation, corresponding wear areas, knee kinematics and particle composition. Clin Biomech (Bristol, Avon) 24:210–217CrossRef
18.
Zurück zum Zitat Hakki S, Saleh KJ, Potty AG, Bilotta V, Oliveira D (2013) Columbus navigated TKA system: clinical and radiological results at a minimum of 5 years with survivorship analysis. Orthopedics 36:e308–e318CrossRefPubMed Hakki S, Saleh KJ, Potty AG, Bilotta V, Oliveira D (2013) Columbus navigated TKA system: clinical and radiological results at a minimum of 5 years with survivorship analysis. Orthopedics 36:e308–e318CrossRefPubMed
19.
Zurück zum Zitat Han HS, Kang SB, Yoon KS (2007) High incidence of loosening of the femoral component in legacy posterior stabilised-flex total knee replacement. J Bone Joint Surg Br 89:1457–1461CrossRefPubMed Han HS, Kang SB, Yoon KS (2007) High incidence of loosening of the femoral component in legacy posterior stabilised-flex total knee replacement. J Bone Joint Surg Br 89:1457–1461CrossRefPubMed
20.
Zurück zum Zitat Hilding MB, Lanshammar H, Ryd L (1996) Knee joint loading and tibial component loosening. RSA and gait analysis in 45 osteoarthritic patients before and after TKA. J Bone Joint Surg Br 78:66–73PubMed Hilding MB, Lanshammar H, Ryd L (1996) Knee joint loading and tibial component loosening. RSA and gait analysis in 45 osteoarthritic patients before and after TKA. J Bone Joint Surg Br 78:66–73PubMed
21.
Zurück zum Zitat Hofmann AA, Tkach TK, Evanich CJ, Camargo MP (2000) Posterior stabilization in total knee arthroplasty with use of an ultracongruent polyethylene insert. J Arthroplasty 15:576–583CrossRefPubMed Hofmann AA, Tkach TK, Evanich CJ, Camargo MP (2000) Posterior stabilization in total knee arthroplasty with use of an ultracongruent polyethylene insert. J Arthroplasty 15:576–583CrossRefPubMed
22.
Zurück zum Zitat Iosifidis M, Iliopoulos E, Neofytou D, Sakorafas N, Andreou D, Alvanos D, Kyriakidis A (2014) The Rotaglide mobile-bearing total knee arthroplasty: no difference between cemented and hybrid implantation. Knee Surg Sports Traumatol Arthrosc 22:1843–1848CrossRefPubMed Iosifidis M, Iliopoulos E, Neofytou D, Sakorafas N, Andreou D, Alvanos D, Kyriakidis A (2014) The Rotaglide mobile-bearing total knee arthroplasty: no difference between cemented and hybrid implantation. Knee Surg Sports Traumatol Arthrosc 22:1843–1848CrossRefPubMed
23.
Zurück zum Zitat Ko YB, Jang EC, Park SM, Kim SH, Kwak YH, Lee HJ (2015) No difference in clinical and radiologic outcomes after total knee arthroplasty with a new ultra-congruent mobile bearing system and rotating platform mobile bearing systems after minimum 5-year follow-up. J Arthroplasty 30:379–383CrossRefPubMed Ko YB, Jang EC, Park SM, Kim SH, Kwak YH, Lee HJ (2015) No difference in clinical and radiologic outcomes after total knee arthroplasty with a new ultra-congruent mobile bearing system and rotating platform mobile bearing systems after minimum 5-year follow-up. J Arthroplasty 30:379–383CrossRefPubMed
24.
Zurück zum Zitat Kwak JY, Jeong JH, Lee SH, Jung HJ, Jung YB (2012) Comparison of the clinical outcomes after total knee arthroplasty with the LCS rotating platform mobile bearing knee system and the PFC Sigma RP-F mobile bearing knee system. Clin Orthop Surg 4:256–262CrossRefPubMedPubMedCentral Kwak JY, Jeong JH, Lee SH, Jung HJ, Jung YB (2012) Comparison of the clinical outcomes after total knee arthroplasty with the LCS rotating platform mobile bearing knee system and the PFC Sigma RP-F mobile bearing knee system. Clin Orthop Surg 4:256–262CrossRefPubMedPubMedCentral
25.
Zurück zum Zitat Laskin RS, Maruyama Y, Villaneuva M, Bourne R (2000) Deep-dish congruent tibial component use in total knee arthroplasty: a randomized prospective study. Clin Orthop Relat Res 380:36–44CrossRef Laskin RS, Maruyama Y, Villaneuva M, Bourne R (2000) Deep-dish congruent tibial component use in total knee arthroplasty: a randomized prospective study. Clin Orthop Relat Res 380:36–44CrossRef
26.
Zurück zum Zitat Lee HJ, Lee JS, Jung HJ, Song KS, Yang JJ, Park CW (2011) Comparison of joint line position changes after primary bilateral total knee arthroplasty performed using the navigation-assisted measured gap resection or gap balancing techniques. Knee Surg Sports Traumatol Arthrosc 19:2027–2032CrossRefPubMed Lee HJ, Lee JS, Jung HJ, Song KS, Yang JJ, Park CW (2011) Comparison of joint line position changes after primary bilateral total knee arthroplasty performed using the navigation-assisted measured gap resection or gap balancing techniques. Knee Surg Sports Traumatol Arthrosc 19:2027–2032CrossRefPubMed
27.
Zurück zum Zitat Marques CJ, Daniel S, Sufi-Siavach A, Lampe F (2015) No differences in clinical outcomes between fixed- and mobile-bearing computer-assisted total knee arthroplasties and no correlations between navigation data and clinical scores. Knee Surg Sports Traumatol Arthrosc 23:1660–1668CrossRefPubMed Marques CJ, Daniel S, Sufi-Siavach A, Lampe F (2015) No differences in clinical outcomes between fixed- and mobile-bearing computer-assisted total knee arthroplasties and no correlations between navigation data and clinical scores. Knee Surg Sports Traumatol Arthrosc 23:1660–1668CrossRefPubMed
28.
Zurück zum Zitat Massin P, Boyer P, Sabourin M (2012) Less femorotibial rotation and AP translation in deep-dished total knee arthroplasty. An intraoperative kinematic study using navigation. Knee Surg Sports Traumatol Arthrosc 20:1714–1719CrossRefPubMed Massin P, Boyer P, Sabourin M (2012) Less femorotibial rotation and AP translation in deep-dished total knee arthroplasty. An intraoperative kinematic study using navigation. Knee Surg Sports Traumatol Arthrosc 20:1714–1719CrossRefPubMed
29.
Zurück zum Zitat Meftah M, Ranawat AS, Ranawat CS (2012) Ten-year follow-up of a rotating-platform, posterior-stabilized total knee arthroplasty. J Bone Joint Surg Am 94:426–432CrossRefPubMed Meftah M, Ranawat AS, Ranawat CS (2012) Ten-year follow-up of a rotating-platform, posterior-stabilized total knee arthroplasty. J Bone Joint Surg Am 94:426–432CrossRefPubMed
30.
Zurück zum Zitat Moreland JR (1988) Mechanisms of failure in total knee arthroplasty. Clin Orthop Relat Res 226:49–64 Moreland JR (1988) Mechanisms of failure in total knee arthroplasty. Clin Orthop Relat Res 226:49–64
31.
Zurück zum Zitat Partington PF, Sawhney J, Rorabeck CH, Barrack RL, Moore J (1999) Joint line restoration after revision total knee arthroplasty. Clin Orthop Relat Res 367:165–171CrossRef Partington PF, Sawhney J, Rorabeck CH, Barrack RL, Moore J (1999) Joint line restoration after revision total knee arthroplasty. Clin Orthop Relat Res 367:165–171CrossRef
32.
Zurück zum Zitat Peters CL, Mulkey P, Erickson J, Anderson MB, Pelt CE (2014) Comparison of total knee arthroplasty with highly congruent anterior-stabilized bearings versus a cruciate-retaining design. Clin Orthop Relat Res 472:175–180CrossRefPubMed Peters CL, Mulkey P, Erickson J, Anderson MB, Pelt CE (2014) Comparison of total knee arthroplasty with highly congruent anterior-stabilized bearings versus a cruciate-retaining design. Clin Orthop Relat Res 472:175–180CrossRefPubMed
33.
Zurück zum Zitat Ritter MA, Harty LD, Davis KE, Meding JB, Berend ME (2003) Predicting range of motion after total knee arthroplasty. Clustering, log-linear regression, and regression tree analysis. J Bone Joint Surg Am 85-a:1278–1285CrossRefPubMed Ritter MA, Harty LD, Davis KE, Meding JB, Berend ME (2003) Predicting range of motion after total knee arthroplasty. Clustering, log-linear regression, and regression tree analysis. J Bone Joint Surg Am 85-a:1278–1285CrossRefPubMed
34.
Zurück zum Zitat Sparmann M, Wolke B, Czupalla H, Banzer D, Zink A (2003) Positioning of total knee arthroplasty with and without navigation support. A prospective, randomised study. J Bone Joint Surg Br 85:830–835PubMed Sparmann M, Wolke B, Czupalla H, Banzer D, Zink A (2003) Positioning of total knee arthroplasty with and without navigation support. A prospective, randomised study. J Bone Joint Surg Br 85:830–835PubMed
35.
Zurück zum Zitat Vanlommel J, Luyckx JP, Labey L, Innocenti B, De Corte R, Bellemans J (2011) Cementing the tibial component in total knee arthroplasty: which technique is the best? J Arthroplasty 26:492–496CrossRefPubMed Vanlommel J, Luyckx JP, Labey L, Innocenti B, De Corte R, Bellemans J (2011) Cementing the tibial component in total knee arthroplasty: which technique is the best? J Arthroplasty 26:492–496CrossRefPubMed
36.
Zurück zum Zitat Wajsfisz A, Biau D, Boisrenoult P, Beaufils P (2010) Comparative study of intraoperative knee flexion with three different TKR designs. Orthop Traumatol Surg Res 96:242–248CrossRefPubMed Wajsfisz A, Biau D, Boisrenoult P, Beaufils P (2010) Comparative study of intraoperative knee flexion with three different TKR designs. Orthop Traumatol Surg Res 96:242–248CrossRefPubMed
37.
Zurück zum Zitat Yau WP, Chiu KY, Tang WM, Ng TP (2005) Residual posterior femoral condyle osteophyte affects the flexion range after total knee replacement. Int Orthop 29:375–379CrossRefPubMedPubMedCentral Yau WP, Chiu KY, Tang WM, Ng TP (2005) Residual posterior femoral condyle osteophyte affects the flexion range after total knee replacement. Int Orthop 29:375–379CrossRefPubMedPubMedCentral
38.
Zurück zum Zitat Youm YS, Cho SD, Lee SH, Cho HY (2014) Total knee arthroplasty using a posterior cruciate ligament sacrificing medial pivot knee: minimum 5-year follow-up results. Knee Surg Relat Res 26:135–140CrossRefPubMedPubMedCentral Youm YS, Cho SD, Lee SH, Cho HY (2014) Total knee arthroplasty using a posterior cruciate ligament sacrificing medial pivot knee: minimum 5-year follow-up results. Knee Surg Relat Res 26:135–140CrossRefPubMedPubMedCentral
Metadaten
Titel
Comparison of ultra-congruent mobile- and fixed-bearing navigation-assisted total knee arthroplasty with minimum 5-year follow-up
verfasst von
Seong Hwan Kim
Jung-Won Lim
Young-Bong Ko
Min-Gu Song
Han-Jun Lee
Publikationsdatum
04.05.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 11/2016
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-016-4147-5

Weitere Artikel der Ausgabe 11/2016

Knee Surgery, Sports Traumatology, Arthroscopy 11/2016 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.