Coronary artery perforation after crush technique for stent compression

verfasst von: A. Avci, M.D., S. Fidan, G. Alıcı, G. Acar, C. Toprak, S. Izci, A.M. Esen

Erschienen in: Herz | Ausgabe 3/2015

Einloggen, um Zugang zu erhalten

Excerpt

Use of new metal alloys such as cobalt chromium or platinum chromium has enabled stents to have thinner struts. Thinner struts, in turn, improved the deliverability and conformability. In addition, to improve the flexibility, the numbers of fixed links between the stent cells were also reduced. These design differences in stent platforms resulted in decreased longitudinal stent integrity. Decreased longitudinal axial strength led to a newly described complication called longitudinal stent compression or the concertina effect [1]. …
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Rigattieri S, Sciahbasi A, Loschiavo P (2013) The clinical spectrum of longitudinal deformation of coronary stents: from a mere angiographic finding to a severe complication. J Invasive Cardiol 25(5):E101–E105PubMed Rigattieri S, Sciahbasi A, Loschiavo P (2013) The clinical spectrum of longitudinal deformation of coronary stents: from a mere angiographic finding to a severe complication. J Invasive Cardiol 25(5):E101–E105PubMed
2.
Zurück zum Zitat Kwok OH (2013) Stent “Concertina:” stent design does matter. J Invasive Cardiol 25(6):E114–E119PubMed Kwok OH (2013) Stent “Concertina:” stent design does matter. J Invasive Cardiol 25(6):E114–E119PubMed
3.
Zurück zum Zitat Leibundgut G, Gick M, Toma A et al (2013) Longitudinal compression of the platinum-chromium everolimus-eluting stent during coronary implanttaion: predisposing mechanical properties, incidence and predictors in a large cohort. Catheter Cardiovasc Interv 81(5):E206–E221CrossRefPubMed Leibundgut G, Gick M, Toma A et al (2013) Longitudinal compression of the platinum-chromium everolimus-eluting stent during coronary implanttaion: predisposing mechanical properties, incidence and predictors in a large cohort. Catheter Cardiovasc Interv 81(5):E206–E221CrossRefPubMed
4.
Zurück zum Zitat Williams PD, Mamas MA, Morgan KP et al (2012) Longitudinal stent deformation: a retrospective analysis of frequency and mechanisms. EuroIntervention 8(2):E267–E274CrossRef Williams PD, Mamas MA, Morgan KP et al (2012) Longitudinal stent deformation: a retrospective analysis of frequency and mechanisms. EuroIntervention 8(2):E267–E274CrossRef
5.
Zurück zum Zitat Robinson AD, Schreiber TL, Sobh MA et al (2011) Deformation, longitudinal shortening, and accordion of an ion stent. J Interv Cardiol 24(6):E493–E495CrossRef Robinson AD, Schreiber TL, Sobh MA et al (2011) Deformation, longitudinal shortening, and accordion of an ion stent. J Interv Cardiol 24(6):E493–E495CrossRef
Metadaten
Titel
Coronary artery perforation after crush technique for stent compression
verfasst von
A. Avci, M.D.
S. Fidan
G. Alıcı
G. Acar
C. Toprak
S. Izci
A.M. Esen
Publikationsdatum
01.05.2015
Verlag
Urban & Vogel
Erschienen in
Herz / Ausgabe 3/2015
Print ISSN: 0340-9937
Elektronische ISSN: 1615-6692
DOI
https://doi.org/10.1007/s00059-014-4052-y

Weitere Artikel der Ausgabe 3/2015

Herz 3/2015 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.