No. | Age (years)/sex | Site | Dome [mm]/D/N-Ratio | Alpha angleb | Previous Treatment | Stent Size | Immediate RROC | Intraprocedural complication | DSA FU (days) | FU RROC | FU mRS |
---|---|---|---|---|---|---|---|---|---|---|---|
1 | 47/F | MCA | 2.9/1.4 | 19 | N | 3 × 28 | 1 | N | N/Aa | N/Aa | 0 |
2 | 59/M | MCA | 3.5/1 | 24 | N | 3 × 24 | 1 | N | N/Aa | N/Aa | 0 |
3 | 58/F | MCA | 4.0/0.9 | 9 | N | 3 × 24 | 2 | N | 96 | 2 | 0 |
4 | 61/F | PcaA | 1.8/1.2 | 24 | Coiling | 2.5 × 22 | 1 | N | 96 | 1 | 0 |
5 | 61/M | AcomA | 1.3/1.0 | 4 | N | 2.5 × 22 | 1 | N | N/Aa | N/Aa | 0 |
6 | 56/M | MCA | 1.5/1.5 | 26 | Coiling | 2.5 × 22 | 1 | N | 115 | 1 | 0 |
7 | 56/M | MCA | 3.1/0.9 | 17 | N | 3 × 24 | 1 | N | 133 | 1 | 0 |
8 | 50/F | ICA‑T | 3.2/1.6 | 47 | N | 3.5 × 22 | 1 | N | 193 | 1 | 0 |
9 | 38/F | AcomA | 5.6/1.1 | 72 | Coiling | 2.5 × 22 | 1 | N | 89 | 1 | 0 |
10 | 52/F | MCA | 1.9/1.7 | 29 | N | 2.5 × 17 | 1 | N | 98 | 1 | 0 |
11 | 65/M | AcomA | 4.7/1.2 | 38 | N | 2.5 × 27 | 1 | N | 7 | 1 | 1 |
12 | 54/M | MCA | 1.6/0.7 | 27 | N | 2.5 × 17 | 1 | N | 357 | 1 | 0 |
13 | 48/F | MCA | 1.3/1.5 | 38 | Coiling | 3 × 24 | 1 | N | 399 | 1 | 0 |
14 | 62/F | AcomA | 2.0/1.0 | 43 | N | 3 × 24 | 1 | N | 419 | 1 | 0 |
15 | 67/M | MCA | 4.7/1.3 | 11 | N | 3 × 28 | 1 | N | N/Aa | N/Aa | 0 |
Open Access 28.09.2021 | Correction
Correction to: “Shelf” Technique Using a Novel Braided Self-Expandable Stent for the Treatment of Wide-Necked Bifurcation Aneurysms
Erschienen in: Clinical Neuroradiology | Ausgabe 4/2021