Skip to main content
Erschienen in: CardioVascular and Interventional Radiology 3/2010

01.06.2010 | Technical Note

CT-Guided Fiducial Placement for CyberKnife Stereotactic Radiosurgery: An Initial Experience

verfasst von: Evangelia Sotiropoulou, Ιrene Stathochristopoulou, Konstantinos Stathopoulos, Kosmas Verigos, Nikolaos Salvaras, Loukas Thanos

Erschienen in: CardioVascular and Interventional Radiology | Ausgabe 3/2010

Einloggen, um Zugang zu erhalten

Abstract

CyberKnife frameless image-guided radiosurgery has become a widely used system for parenchymal extracranial lesions. Gold fiducials are required for the planning and aiming of CyberKnife therapy. We report our initial experience and describe the technique of positioning tumor markers, under CT guidance. We conducted a retrospective review of 105 patients who were referred for CyberKnife stereotactic radiosurgery at Iatropolis CyberKnife Center in Athens. All patients underwent percutaneous fiducial placement via CT guidance. At the desired location, the 18-G needle was advanced into or near the tumor. Data collected included number and locations of fiducials placed and complications experienced to date. One hundred five patients underwent fiducial placement under CT guidance and a total number of 319 gold seeds were implanted. We experienced one episode of pneumothorax that required drainage, one mild pneumothorax, and three episodes of perifocal pulmonary hemorrhage. In conclusion, fiducial implantation under CT guidance appears to be a safe and efficient procedure, as long as it is performed by an experienced interventional radiologist.
Literatur
1.
Zurück zum Zitat Casamassima F, Cavedon C, Francescon P et al (2006) Use of motion tracking in stereotactic body radiotherapy: evaluation of uncertainty in off-target dose distribution and optimization strategies. Acta Oncol 45:943–947CrossRefPubMed Casamassima F, Cavedon C, Francescon P et al (2006) Use of motion tracking in stereotactic body radiotherapy: evaluation of uncertainty in off-target dose distribution and optimization strategies. Acta Oncol 45:943–947CrossRefPubMed
2.
Zurück zum Zitat Adler JR Jr, Chang SD, Murphy MJ et al (1997) The Cyberknife: a frameless robotic system for radiosurgery. Stereotact Funct Neurosurg 69:124–128CrossRefPubMed Adler JR Jr, Chang SD, Murphy MJ et al (1997) The Cyberknife: a frameless robotic system for radiosurgery. Stereotact Funct Neurosurg 69:124–128CrossRefPubMed
3.
Zurück zum Zitat Kuo JS, Yu C, Petrovich Z et al (2003) The CyberKnife stereotactic radiosurgery system: description, installation, and an initial evaluation of use and functionality. Neurosurgery 53:1235–1239 (discussion 1239)CrossRefPubMed Kuo JS, Yu C, Petrovich Z et al (2003) The CyberKnife stereotactic radiosurgery system: description, installation, and an initial evaluation of use and functionality. Neurosurgery 53:1235–1239 (discussion 1239)CrossRefPubMed
4.
5.
Zurück zum Zitat Gerszten PC, Burton SA, Ozhasoglu C et al (2005) Stereotactic radiosurgery for spinal metastases from renal cell carcinoma. J Neurosurg Spine 3:288–295CrossRefPubMed Gerszten PC, Burton SA, Ozhasoglu C et al (2005) Stereotactic radiosurgery for spinal metastases from renal cell carcinoma. J Neurosurg Spine 3:288–295CrossRefPubMed
6.
Zurück zum Zitat Chang SD, Murphy M, Geis P et al (1998) Clinical experience with image-guided robotic radiosurgery (the Cyberknife) in the treatment of brain and spinal cord tumors. Neurol Med Chir 38:780–783CrossRef Chang SD, Murphy M, Geis P et al (1998) Clinical experience with image-guided robotic radiosurgery (the Cyberknife) in the treatment of brain and spinal cord tumors. Neurol Med Chir 38:780–783CrossRef
7.
Zurück zum Zitat Whyte RI, Crownover R, Murphy MJ et al (2003) Stereotactic radiosurgery for lung tumors: preliminary report of a phase I trial. Ann Thorac Surg 75:1097–1101CrossRefPubMed Whyte RI, Crownover R, Murphy MJ et al (2003) Stereotactic radiosurgery for lung tumors: preliminary report of a phase I trial. Ann Thorac Surg 75:1097–1101CrossRefPubMed
8.
Zurück zum Zitat Koong AC, Christofferson E, Le QT et al (2005) Phase II study to assess the efficacy of conventionally fractionated radiotherapy followed by a stereotactic radiosurgery boost in patients with locally advanced pancreatic cancer. Int J Radiat Oncol Biol Phys 63:320–323PubMed Koong AC, Christofferson E, Le QT et al (2005) Phase II study to assess the efficacy of conventionally fractionated radiotherapy followed by a stereotactic radiosurgery boost in patients with locally advanced pancreatic cancer. Int J Radiat Oncol Biol Phys 63:320–323PubMed
9.
Zurück zum Zitat Koong AC, Le QT, Ho A et al (2004) Phase I study of stereotactic radiosurgery in patients with locally advanced pancreatic cancer. Int J Radiat Oncol Biol Phys 58:1017–1021PubMed Koong AC, Le QT, Ho A et al (2004) Phase I study of stereotactic radiosurgery in patients with locally advanced pancreatic cancer. Int J Radiat Oncol Biol Phys 58:1017–1021PubMed
10.
Zurück zum Zitat King CR, Lehmann J, Adler JR et al (2003) CyberKnife radiotherapy for localized prostate cancer: rationale and technical feasibility. Technol Cancer Res Treat 2:25–30PubMed King CR, Lehmann J, Adler JR et al (2003) CyberKnife radiotherapy for localized prostate cancer: rationale and technical feasibility. Technol Cancer Res Treat 2:25–30PubMed
11.
Zurück zum Zitat Blomgren H, Lax I, Naslund I et al (1995) Stereotactic high dose fraction radiation therapy of extracranial tumors using an accelerator. Clinical experience of the first thirty-one patients. Acta Oncol 34:861–870CrossRefPubMed Blomgren H, Lax I, Naslund I et al (1995) Stereotactic high dose fraction radiation therapy of extracranial tumors using an accelerator. Clinical experience of the first thirty-one patients. Acta Oncol 34:861–870CrossRefPubMed
12.
Zurück zum Zitat Herfarth KK, Debus J, Lohr F et al (2001) Stereotactic single-dose radiation therapy of liver tumors: results of a phase I/II trial. J Clin Oncol 19:164–170PubMed Herfarth KK, Debus J, Lohr F et al (2001) Stereotactic single-dose radiation therapy of liver tumors: results of a phase I/II trial. J Clin Oncol 19:164–170PubMed
13.
Zurück zum Zitat Wulf J, Hadinger U, Oppitz U et al (2001) Stereotactic radiotherapy of targets in the lung and liver. Strahlenther Onkol 177:645–655CrossRefPubMed Wulf J, Hadinger U, Oppitz U et al (2001) Stereotactic radiotherapy of targets in the lung and liver. Strahlenther Onkol 177:645–655CrossRefPubMed
14.
Zurück zum Zitat Yu C, Main W, Taylor D et al (2004) An anthropomorphic phantom study of the accuracy of CyberKknife spinal radiosurgery. Neurosurgery 55:1138–1149CrossRefPubMed Yu C, Main W, Taylor D et al (2004) An anthropomorphic phantom study of the accuracy of CyberKknife spinal radiosurgery. Neurosurgery 55:1138–1149CrossRefPubMed
15.
Zurück zum Zitat Ryu SI, Chang SD, Kim DH et al (2001) Image-guided hypofractionated stereotactic radiosurgery to spinal lesions. Neurosurgery 49:838–846CrossRefPubMed Ryu SI, Chang SD, Kim DH et al (2001) Image-guided hypofractionated stereotactic radiosurgery to spinal lesions. Neurosurgery 49:838–846CrossRefPubMed
16.
Zurück zum Zitat Berbeco RI, Nishioka S, Shirato H et al (2005) Residual motion of lung tumours in gated radiotherapy with external respiratory surrogates. Phys Med Biol 50:3655–3667CrossRefPubMed Berbeco RI, Nishioka S, Shirato H et al (2005) Residual motion of lung tumours in gated radiotherapy with external respiratory surrogates. Phys Med Biol 50:3655–3667CrossRefPubMed
17.
Zurück zum Zitat Shirato H, Shimizu S, Kunieda T et al (2000) Physical aspects of a real-time tumor -tracking system for gated radiotherapy. Int J Radiat Oncol Biol Phys 48:1187–1195CrossRefPubMed Shirato H, Shimizu S, Kunieda T et al (2000) Physical aspects of a real-time tumor -tracking system for gated radiotherapy. Int J Radiat Oncol Biol Phys 48:1187–1195CrossRefPubMed
18.
Zurück zum Zitat Fu D, Kuduvalli G (2006) Enhancing skeletal features in digitally reconstructed radiographs. In: Reinhardt JM, Pluim JP (eds). Proceedings of SPIE International Society for Optical Engineering 6144:846–851 Fu D, Kuduvalli G (2006) Enhancing skeletal features in digitally reconstructed radiographs. In: Reinhardt JM, Pluim JP (eds). Proceedings of SPIE International Society for Optical Engineering 6144:846–851
19.
Zurück zum Zitat Fu D, Kuduvalli G, Maurer CR et al (2006) 3D target localization using 2D local displacements of skeletal structures in orthogonal X-ray images for image-guided spinal radiosurgery. Int J Comput Assist Radiol Surg Suppl 1:198–200 Fu D, Kuduvalli G, Maurer CR et al (2006) 3D target localization using 2D local displacements of skeletal structures in orthogonal X-ray images for image-guided spinal radiosurgery. Int J Comput Assist Radiol Surg Suppl 1:198–200
20.
Zurück zum Zitat Sinner W (1976) Complications of percutaneous thoracic needle aspiration biopsy. Acta Radiol Diagn 17:813–828 Sinner W (1976) Complications of percutaneous thoracic needle aspiration biopsy. Acta Radiol Diagn 17:813–828
21.
Zurück zum Zitat Laurent F, Latrabe V, Vergier B et al (2000) Percutaneous CT-guided biopsy of the lung: comparison between aspiration and automated cutting needles using a coaxial technique. CardioVasc Interv Radiol 23:266–272CrossRef Laurent F, Latrabe V, Vergier B et al (2000) Percutaneous CT-guided biopsy of the lung: comparison between aspiration and automated cutting needles using a coaxial technique. CardioVasc Interv Radiol 23:266–272CrossRef
22.
Zurück zum Zitat Klein JS, Salomon G, Stewart EA (1996) Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle: results in 122 patients. Radiology 198:715–720PubMed Klein JS, Salomon G, Stewart EA (1996) Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle: results in 122 patients. Radiology 198:715–720PubMed
23.
Zurück zum Zitat Richardson CM, Pointon KS, Manhire AR et al (2002) Percutaneous lung biopsies: a survey of UK practice based on 5444 biopsies. Br J Radiol 75:731–735PubMed Richardson CM, Pointon KS, Manhire AR et al (2002) Percutaneous lung biopsies: a survey of UK practice based on 5444 biopsies. Br J Radiol 75:731–735PubMed
24.
Zurück zum Zitat Glassberg RM, Sussman SK (1990) Life threatening haemorrhage due to percutaneous thoracic intervention: importance of the internal mammary artery. AJR 154:47–49PubMed Glassberg RM, Sussman SK (1990) Life threatening haemorrhage due to percutaneous thoracic intervention: importance of the internal mammary artery. AJR 154:47–49PubMed
25.
Zurück zum Zitat Kumaradevan J, Babar S, Watkinson AF (2000) Complications of abdominal biopsy. Imaging 12:226–234 Kumaradevan J, Babar S, Watkinson AF (2000) Complications of abdominal biopsy. Imaging 12:226–234
26.
Zurück zum Zitat Livraghi T, Damascelli B, Lombardi C et al (1983) Risk in fine-needle abdominal biopsy. J Clin Ultrasound 11(2):77–81CrossRefPubMed Livraghi T, Damascelli B, Lombardi C et al (1983) Risk in fine-needle abdominal biopsy. J Clin Ultrasound 11(2):77–81CrossRefPubMed
27.
Zurück zum Zitat Rosenbaum DA, Frost DB (1990) Fine-needle aspiration biopsy of the pancreas complicated by pancreatic ascites. Cancer 65:2537–2538CrossRefPubMed Rosenbaum DA, Frost DB (1990) Fine-needle aspiration biopsy of the pancreas complicated by pancreatic ascites. Cancer 65:2537–2538CrossRefPubMed
28.
Zurück zum Zitat Frederiksen P, Thommesen P, Skjoldborg H (1976) Pancreatic fistula and hematoma (one each). Fine-needle aspiration biopsy of the pancreas. Scand J Gastroenterol 1(1):785–791 Frederiksen P, Thommesen P, Skjoldborg H (1976) Pancreatic fistula and hematoma (one each). Fine-needle aspiration biopsy of the pancreas. Scand J Gastroenterol 1(1):785–791
29.
Zurück zum Zitat Shirato H, Harada T, Harabayashi T et al (2004) Feasibility of insertion/implantation of 2.0-mm-diameter gold internal fiducial markers for precise set up and real-time tumor tracking in radiotherapy. Int J Radiat Oncol Biol Phys 60:329–334CrossRef Shirato H, Harada T, Harabayashi T et al (2004) Feasibility of insertion/implantation of 2.0-mm-diameter gold internal fiducial markers for precise set up and real-time tumor tracking in radiotherapy. Int J Radiat Oncol Biol Phys 60:329–334CrossRef
Metadaten
Titel
CT-Guided Fiducial Placement for CyberKnife Stereotactic Radiosurgery: An Initial Experience
verfasst von
Evangelia Sotiropoulou
Ιrene Stathochristopoulou
Konstantinos Stathopoulos
Kosmas Verigos
Nikolaos Salvaras
Loukas Thanos
Publikationsdatum
01.06.2010
Verlag
Springer-Verlag
Erschienen in
CardioVascular and Interventional Radiology / Ausgabe 3/2010
Print ISSN: 0174-1551
Elektronische ISSN: 1432-086X
DOI
https://doi.org/10.1007/s00270-009-9748-7

Weitere Artikel der Ausgabe 3/2010

CardioVascular and Interventional Radiology 3/2010 Zur Ausgabe

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.