Diagnostic accuracy and additional value of diffusion-weighted imaging for discrimination of malignant cervical lymph nodes in head and neck squamous cell carcinoma
verfasst von:
R. B. J. de Bondt, M. C. Hoeberigs, P. J. Nelemans, W. M. L. L. G. Deserno, C. Peutz-Kootstra, B. Kremer, R. G. H. Beets-Tan
The aim was to determine the diagnostic accuracy and additional value of diffusion-weighted imaging for detection of malignant lymph nodes in head and neck squamous cell carcinoma.
Methods
Two hundred nineteen lymph nodes, predominantly smaller than 10 mm (95.4%), in 16 consecutive patients were evaluated at 1.5 T. Lymph nodes were evaluated for maximum short axial diameter, morphological criteria, and apparent diffusion coefficient (ADC) values (b = 0 and b = 1,000 s/mm2). Sensitivity, specificity, positive and negative predictive values as well as diagnostic odds ratios (DORs) and areas under the curves (AUCs) of ROC curves were calculated for the various magnetic resonance imaging (MRI) criteria individually and in combination. Histological examination of lymph nodes in the neck dissection specimen was the gold standard to determine malignant involvement.
Results
The optimal ADC threshold was 1.0 × 10−3 mm2/s. Using this cutoff point, sensitivity and specificity were 92.3% and 83.9%, respectively. When used in combination with size and morphological criteria, ADC value <1.0 × 10−3 mm2/s was the strongest predictor of presence of metastasis (DOR = 97.6). A model which added ADC values to the other MRI criteria performed significantly better than a model without ADC values: AUC = 0.98 versus AUC = 0.91 (p = 0.036).
Conclusion
In this study, with predominantly small lymph nodes, the ADC criterion is the strongest independent predictor of presence of metastasis. The use of ADC values in combination with the other MRI criteria significantly improves the discrimination between malignant and benign lymph nodes.
Introduction
The presence of cervical lymph node metastases is an important prognostic factor in patients with head and neck squamous cell carcinoma (HNSCC) as this significantly worsens the treatment outcome [1‐8]. Radiological imaging plays an increasingly important role in accurate assessment of the lymph node status of the neck.
Frequently used criteria for differentiation between benign and malignant lymph nodes are the presence of necrosis—mainly seen in larger lymph nodes—and assessment of lymph node morphology such as borders and internal heterogeneity [9, 10]. Also the introduction of lymph node specific contrast agents like ultrasmall particles iron oxide on magnetic resonance imaging (MRI) provides differentiation between benign and malignant lymph nodes in the head and neck and results are improving [11‐16].
Anzeige
Another commonly used criterion is the maximum short axial diameter for which several studies have been undertaken to determine the optimal cutoff size [17, 18]. Small lymph nodes with a maximum short axial diameter below 10 mm are more challenging for radiologists, because the mere use of this size criterion will result in misclassification of malignant lymph nodes as normal on MRI evaluation. According to the literature, the performance of MRI is still poor in the assessment of lymph node metastases, and this concerns especially the detection of metastases in small lymph nodes [11].
Diffusion-weighted imaging (DWI) is a noninvasive MRI technique that provides image contrast dependent on the molecular motion of water. Any architectural changes in the proportion of extracellular to intracellular water protons—like metastases in lymph nodes—will alter the diffusion coefficient of the tissue. Therefore, DWI provides in characterization of different tissues and lesions. Previous reports showed the utility of DWI in the region of the head and neck for different pathology [19‐26]. In studies focused on nodal staging, the imaging results were based on series with only clinical positive necks in which large lymph nodes were selected for evaluation [27‐30]. Studies focusing on mainly negative necks at clinical examination are scarce. The aim of this study was to prospectively determine the diagnostic accuracy and additional value of DWI–MRI to conventional MRI—using size and morphology criteria—for differentiation between malignant and normal cervical lymph nodes.
Materials and methods
Patients
The local medical ethics committee approved this prospective study. Between March 2006 and December 2007, a series of 16 consecutive patients with a HNSCC who were scheduled for a supraomohyoid neck dissection (SOHND), selective or radical neck dissection (RND) enrolled in this study. All patients underwent MR imaging as part of the routine diagnostic workup; the findings of diffusion-weighted imaging were not used for clinical decision making. MR imaging was performed previous to ultrasonography with fine needle aspiration cytology of lymph nodes in the neck.
MR imaging
All examinations were performed at 1.5 T (Gyroscan, Powertrack 6000, Philips, Best, The Netherlands) using a Head–Neck coil (Philips, Best, The Netherlands). The Synergy Head–Neck coil was used for both the conventional and diffusion-weighted MR imaging; the range was from the base of skull to the level of the clavicles. To ascertain correlation of the conventional images and DWI, all sequences were acquired with similar geometry.
Anzeige
The conventional MR protocol consisted of axial fat-suppressed T2-weighted (TR/TE 1704/80), axial and coronal T1-weighted (TR/TE 400/12), contrast-enhanced axial and coronal fat-suppressed T1-weighted (TR/TE 740/12), and coronal short tau inversion recovery (TR/TE/TI 5868/60/15) sequences. Slice thickness was 3 mm; there was no interslice gap. The matrix was 272 × 512 with a field of view 220 (rectangular field of view (RFOV) 80%).
Diffusion-weighted images were acquired in the axial plane by using a gradient single-shot echo planar imaging sequence. The sequence was repeated for two b values b = 0 and b = 1,000 s/mm2 with the following parameters: TR/TE 5666/70, section thickness was 3 mm according to the conventional protocol, the matrix was 272 × 512 with a field of view 400 (RFOV 80%), there was no interslice gap, and the number of signal acquisition was 6. A total of 64 slices were acquired which covered the whole neck area from the skull base to the clavicles. The total scan time was 4 min 54 s. DWI was performed before the contrast-enhanced T1-weighted sequences. Apparent diffusion coefficient (ADC) maps were automatically constructed by the postprocessing software of the MR system.
Image evaluation
Two radiologists with specific experience in head and neck imaging (12 and 4 years, respectively) and taking part of multidisciplinary head and neck oncology conferences in a referral hospital independently evaluated the conventional images. Both observers were blinded to each other’s MR assessments and clinical information.
On the conventional MR images, lymph nodes were assessed for size and morphological criteria. All lymph nodes were determined by position and slice number per neck level, the maximum short axial diameter was recorded per lymph node, and lymph nodes were classified as normal (≤10 mm) or malignant (>10 mm). Furthermore, for each lymph node, it was predicted whether it was benign or malignant by using the following morphological criteria determined on the fat-suppressed T2-weighted images: the border of the lymph node (smooth, lobulated, spiculated, or indistinct). Presence of smooth and lobulated borders were considered as indicative of normal lymph nodes whereas that of spiculated and indistinct borders of malignant lymph nodes (Fig. 1). Another criterion was the degree of homogeneity of the signal intensity; homogeneous signal intensity was considered as normal whereas heterogeneous signal intensity was considered as indicative of malignant lymph nodes.
×
Diffusion-weighted images were evaluated on the MRI scanner workstation on which the ADC maps were constructed automatically by the postprocessing software of the MR system. In consensus, the two radiologists, who also assessed the conventional MR images, performed the evaluation of the diffusion-weighted images. To ascertain a node-by-node correlation between the conventional images versus the diffusion-weighted images, all lymph nodes on the T1-weighted and T2-weighted images were correlated to the corresponding b1000 images. On these b1000 images, a region of interest (ROI) was drawn manually around each single lymph node, the ROI was copied to the ADC map, and the ADC value was automatically calculated by the postprocessing software of the MR machine. This was done on all subsequent sections that contained lymph node parenchyma to ensure that most of the lymph node was included. The final ADC value of a lymph node was an average of all values from one single lymph node; this was expressed as mean ± standard deviation. Figure 2 demonstrates an example of this postprocessing technique. A necrotic area in a lymph node, determined as a hyperintense region on the T2-weighted image with a hypointense region on the (contrast-enhanced) T1-weighted images, was excluded from the area of analysis.
×
Pathological examination
All neck dissections were performed “en bloc”. Immediately after the resection, the surgeon positioned the neck dissection specimen on a schematic drawing of the neck in real proportions and fixed it with needles. The pathologist manually identified and localized the lymph nodes per neck level in the specimen. The maximum short axial diameter of all lymph nodes was recorded. Subsequently, lymph nodes were fixed, sectioned, and hematoxylin–eosin (HE) stained and the presence of tumor in each lymph node was examined microscopically. The results at pathology were used as the reference standard.
Pathological–radiological correlation
The neck was subdivided according to the six different levels in agreement with the classification of the American Joint Committee on Cancer; this classification was used by the radiologists when viewing the MR images and used by the pathologist when interpreting the specimen after neck dissection [31].
The results of the measurements on MRI were compared with the results of the pathological examination of the neck dissection specimens. By recording the combination of the maximum short axial diameter and the exact location of each lymph node per neck level—related to surrounding anatomic structures such as blood vessels, muscles, and salivary glands—it was possible to perform a topographic correlation for each lymph node between the pathological examination and the MR images.
Anzeige
Statistical analysis
Interobserver agreement with respect to the evaluation of the criteria size (maximum short axial diameter), border irregularity, and homogeneity of signal intensity on T2-weighted images was expressed by Cohen’s kappa-coefficient (κ). For each lymph node, the scores on MRI criteria were correlated with the results of pathologic examination of the neck dissection specimen. Pathologic results with respect to presence or absence of lymph node metastasis were used as standard of reference. Results on MRI criteria were dichotomized and diagnostic accuracy was evaluated in terms of sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV).
Furthermore, discriminative ability was expressed by the diagnostic odds ratio (DOR). The higher the DOR, the higher the ability of a particular criterion to discriminate between lymph nodes with and without metastasis. A DOR = 1 indicates that the criterion under study has no diagnostic value; a DOR > 1 indicates that the criterion has ability to discriminate between lymph nodes with and without metastasis.
The independent contribution of each criterion under study was analyzed using multivariate logistic regression models. In these models, presence or absence of metastasis according to pathologic examination was the dependent variable and the dichotomized results on MRI criteria were entered as independent variables. Diagnostic odds ratios, which can be derived from these models by exponentiation of the regression coefficients, indicate to what extent each criterion in the model can be used as an independent predictor of the presence of metastasis in a lymph node.
Finally, the added diagnostic value of ADC values to the other MRI criteria (size, border irregularity, and signal intensity on T2-weighted images) was analyzed by using multivariate logistic regression models, which included different sets of MRI criteria. Model-derived predicted probabilities were used to construct receiver operating characteristic (ROC) curves. Areas under the curve (AUCs) with 95% confidence intervals were used to compare the diagnostic accuracy of various models. Differences between the AUCs were tested for statistical significance using the method described by Hanley and McNeil, which accounts for the fact that the AUCs are derived from the same sample of patients. Statistical analyses were performed with SPSS 13 and STATA. In all analyses, p values <0.05 were considered as indicator for statistical significance [32].
Anzeige
Results
In 16 patients (mean age 59 years [range 40–77 years]; seven women and nine men), a total of 17 neck dissections were performed: SOHND, n = 4; RND, n = 4; and selective neck dissection, n = 9. Distribution of the total of 58 dissected neck levels was as follows: level I, n = 17; level II, n = 17; level III, n = 12; level IV, n = 5; and level V, n = 7. Relevant patient characteristics, clinical findings, tumor–node–metastasis (TNM) classification and details of the performed neck dissections are summarized in Table 1.
Table 1
Clinical findings in 16 consecutive patients with primary head and neck squamous cell carcinoma, clinical TNM classification, and details of the performed neck dissections.
Patient no.
Age (years)
Gender
Clinical presentation
Clinical TNM
Neck dissection
Dissected levels
Primary tumor location
Side
Type
Side
1
64
M
Tongue
R
T2N0M0
Selective ND
R
I–III, V
2
75
M
Nasopharynx
L
T2N1M0
Radical ND
L
I–V
3
53
M
Tongue
R
T3N1M0
Radical ND
R
I–V
4
62
F
Tongue
L
T3N0M0
Selective ND
L
I, II
5
58
M
Vallecula
R
T1N0M0
Selective ND
R
I, II, III, V
6
40
M
Tongue
L
T2N0M0
Selective ND
L
I–III
7
54
M
Nasopharynx
L
T1N1M0
Selective ND
L
I–III
8
63
M
Retro molar trigonum
L
T2N0M0
Selective ND
L
I–IV
9
55
F
Submandibular gland
L
T2N0M0
Selective ND
L
I, II
10
72
M
Tongue
L
T2N0M0
Supraomohyoid ND
L
I–III
11
74
F
Cheek
L
T2N0M0
Selective ND
L
I, II
12
51
F
Floor of mouth
R
T2N0M0
Radical ND
R
I–V
13
52
F
Soft palate
L
T2N0M0
Radical ND
L
I–V
14
47
F
Tongue
R
T3N0M0
Supraomohyoid ND
R
I–III
15
50
F
Tongue
R
T2N0M0
Selective ND
R
I, II
16
77
M
Nose
–
T2-3N0M0
Supraomohyoid ND
R
I–III
Supraomohyoid ND
L
I–III
ND neck dissection, L left, R right, M male, F female
At assessment of the MR images of the 58 dissected neck levels, a total of 281 lymph nodes were detected. Of these lymph nodes, 62 had a short axial diameter of ≤2 mm. Because these lymph nodes were not detected at the pathological examination, they were excluded from further analysis. The large majority (13 out of 16) of patients presented without palpable lymph nodes at clinical examination (clinical negative neck); only a few lymph nodes exceeded the maximum short axial diameter of 10 mm at pathological and radiological examination.
Pathological examination revealed 219 lymph nodes, which were matched to the lymph nodes on the MR images. Most lymph nodes were situated at level I (n = 45), level II (n = 100), or level III (n = 49). Only 25 nodes were detected at level IV (n = 7) or level V (n = 18). Evidence of metastases was demonstrated in 26 lymph nodes (node-based prevalence = 11.8%) and in 11 of 16 patients (patient-based prevalence = 68.8%). Lymph node size in relation to the presence of metastases (n = 26) was as follows: 5 mm, n = 5; 6 mm, n = 4; 7 mm, n = 3; 8 mm, n = 6; 9 mm, n = 1; 10 mm, n = 3; 15 mm, n = 1; 18 mm, n = 1; 20 mm, n = 1; and 30 mm, n = 1. The majority (95.4%) of lymph nodes on MRI showed a maximum short axial diameter ≤10 mm. Only ten nodes (4.6%) were >10 mm. Of these ten pathological determined lymph nodes, six were negative at pathological examination (range 11–12 mm in maximum short axial diameter). Four lymph nodes, with maximum short axial diameter ranging from 15–30 mm, showed massive metastasis. Twenty-two of the 26 metastases were found in the lymph nodes ≤10 mm. Figure 3 illustrates a lymph node with maximum short axial diameter of 12 mm with an ADC value of 1.3 × 10−3 mm2/s; pathological examination revealed no metastasis. Observer agreement for the three morphological criteria was κ = 0.86 for size, κ = 1.00 for border irregularity, and κ = 0.91 for signal intensity on the T2-weighted images.
×
Table 2 presents combinations of sensitivity and specificity that were found using different cutoff values for ADC. Lower ADC values correspond with higher probability of lymph node metastasis. ADC values of malignant lymph nodes were significantly lower compared with benign lymph nodes with mean (standard deviation, SD) values of 0.85 × 10−3 mm2/s (SD 0.19 × 10−3 mm2/s), and 1.2 × 10−3 mm2/s (SD 0.24 × 10−3 mm2/s), respectively. High sensitivity combined with acceptable specificity was found for a cutoff point of <1.0 × 10 versus >1.0 × 10−3 mm2/s. This cutoff value was used for further analyses.
Table 2
Sensitivity, specificity, and diagnostic odds ratio with 95% confidence interval for the diagnosis of malignant cervical lymph nodes for different threshold values of the apparent diffusion coefficient.
Threshold
Sensitivity (%)
Specificity (%)
DOR (95% CI)
<0.9 × 10 versus >0.9 × 10−3 mm2/s
69.2
92.2
26.7 (10.0–71.5)
<0.94 × 10 versus >0.94 × 10−3 mm2/s
84.6
90.2
50.4 (15.7–161.6)
<1.0 × 10 versus >1.0 × 10−3 mm2/s
92.3
83.9
62.7 (14.1–279)
Anzeige
Table 3 shows the sensitivity, specificity, PPV and NPV for dichotomized ADC values, and the other MRI criteria such as size, border irregularity, and signal intensity on T2-weighted images. Both the dichotomized size and ADC criteria are associated with the highest sensitivity, but the high sensitivity for size is compromised by a high proportion of false positive results.
Table 3
Sensitivity, specificity, positive predictive value, and negative predictive value for the diagnosis of malignant lymph nodes for the MR criteria: apparent diffusion coefficient (≤1.0 × 10 versus >1.0 × 10−3 mm2/s), size (maximum short axial diameter ≤10 versus >10 mm), border irregularity and signal intensity on T2-weighted images.
Criterion
Sensitivity (%)
Specificity (%)
PPV (%)
NPV (%)
ADC (<1.0 × 10 versus >1.0 × 10−3 mm2/s)
92.3
83.9
43.6
98.8
Size (≤10 versus >10 mm)
92.3
60.6
24.0
98.3
Border irregularity on T2-weighted images (spiculated/indistinct versus smooth/lobulated)
61.5
98.3
84.2
94.4
SI on T2-weighted images (heterogeneous versus homogeneous)
50.0
94.8
56.5
93.3
PPV positive predictive value, NPV negative predictive value, ADC apparent diffusion coefficient, SI signal intensity
Table 4 shows diagnostic odds ratios with 95% confidence intervals (CI) for the individual MRI criteria when they are used separately (derived from univariate analyses) and for the individual MRI criteria when they are used in combination with each other (derived from multivariate analyses). When used separately, the border criterion is associated with the highest ability to discriminate between malignant and benign lymph nodes (DOR = 90.1). However, when used in combination, the ADC criterion is the strongest independent predictor of presence of metastasis (DOR = 97.6) followed by the border criterion (DOR = 56.0). When evaluated in combination with the other criteria, the DOR of 4.4 (with 95% CI 0.7–28.0) associated with size no longer differs significantly from 1 and thus has no independent predictive value.
Table 4
Diagnostic odds ratios with 95% confidence intervals for apparent diffusion coefficient levels and three assessed morphological criteria (size, border, and signal intensity).
MRI criteria
Univariate analysis DOR (95% CI)
Multivariate analysis DOR (95% CI)
ADC threshold (<1.0 × 10 versus >1.0 × 10−3 mm2/s)
62.7 (10.0–71.5)
97.6 (9.7–982)
Size (≤10 versus >10 mm)
18.5 (4.2–80.4)
4.4 (0.7–28.0)
Border irregularity (spiculated/indistinct versus smooth/lobulated)
90.1 (22.5–361)
56.0 (4.4–719)
Signal intensity on T2-weighted image (heterogeneous versus homogeneous)
18.2 (6.7–49.4)
12.8 (1.8–91.6)
Results are derived from univariate and multivariate logistic regression analyses
DOR Diagnostic odds ratio, ADC apparent diffusion coefficient
Table 5 presents areas under the curve with 95% confidence intervals from various models. Model 3, adding ADC values to the other MRI criteria (size, border irregularity, and signal intensity on T2-weighted images), performs significantly better than model 2 that does not add ADC values to the other three criteria: AUC = 0.98 versus AUC = 0.91 (p = 0.036). Moreover, model 1, which includes only ADC as predictor of presence of metastasis, performs nearly as well as model 2, which includes the other three MRI criteria as predictors: AUC = 0.89 versus AUC = 0.91 (p = 0.52).
Table 5
Area under the curve and 95% confidence intervals for predicted probabilities of malignant lymph nodes derived from four models which included different combinations of MRI criteria.
Model
Criteria
AUC
95% CI
1
ADC (alone)
0.89
0.86–0.92
2
Size, border, and signal intensity on T2-weighted images
0.91
0.84–0.99
3
ADC, size, border, and signal intensity on T2-weighted images
0.98
0.97–1.00
4
Size and ADC
0.94
0.91–0.96
AUC area under the curve, ADC apparent diffusion coefficient
Discussion
The results show that apparent diffusion coefficient values calculated on the diffusion-weighted images, alone or in combination with other morphological criteria, are useful in discriminating malignant from benign lymph nodes in head and neck squamous cell carcinoma. ADC values of malignant lymph nodes were significantly lower compared to benign lymph nodes.
At present, there are only few reports that demonstrate the usefulness of DWI–MRI in characterizing lymph nodes in the neck. Some studies reported the ability of DWI to discriminate between different histological lymph node cancers in the neck [28‐30]. Others showed that ADC determination on DWI–MRI may have added value in discriminating malignant from benign lymph nodes in the neck [19, 20, 27]. All studies were performed in patients with palpable cervical lymphadenopathy (clinical positive necks), and further evaluation by MRI was limited to selected enlarged lymph nodes.
In contrast to previous reports, this study is unique in that it mainly dealt with patients with clinically negative necks. In only three out of 16 patients lymph nodes were palpable at clinical examination; however, in only two patients an enlarged lymph node with maximum short axial diameter ranging from 18 to 30 mm could also be demonstrated on MRI and at pathological examination. The large majority of lymph nodes (95.4%) on MRI were ≤10 mm; within this group, the pathologically confirmed malignant lymph nodes ranged a maximum short axial diameter of 5–10 mm. Those small lymph nodes would all be assigned as benign based on the size criterion. Especially the multivariate regression analyses demonstrate that the size criterion no longer differs significantly malignant from benign lymph nodes and thus has no independent predictive value. When used separately, the border criterion is associated with the highest ability to discriminate between lymph nodes with and without metastasis; however, when used in combination, the ADC criterion is the strongest independent predictor of presence of metastasis followed by the border criterion (Table 4).
These results in the clinically negative necks are of great clinical relevance as DWI shows to be an accurate tool to differentiate metastases in small lymph nodes. In a radiologically negative neck, the planned neck dissection could be converted to a wait-and-scan policy, whereas the radiologically determined positive neck would support the decision to perform a neck dissection. The relative high sensitivity and NPV for the size criterion in this study only accounts for lymph nodes exceeding 10 mm in maximum short axial diameter (Table 3). However, as in this study, the large majority of lymph nodes were ≤10 mm; the size criterion does no longer differ in these lymph nodes between malignant and benign lymph nodes. This is expressed by the low DOR for the size criterion in the univariate and multivariate logistic regression analyses (Table 4).
The optimal ADC threshold for this study population appeared to be 1.0 × 10−3 mm2/s (Fig. 4); when the criteria size and morphology on the conventional MR protocol were combined with this ADC threshold value, the area under the curve significantly increased. Figure 5 illustrates the ROC curves derived from predicted probabilities from models including different criteria sets. A model which added ADC values to the other MRI criteria performed significantly better than a model without ADC values whereas the model which includes only ADC performs nearly as well as the model which includes the other three MRI criteria. In a previous study, the same assessed morphological criteria showed—in addition to the size criterion—an increased AUC from 0.91 to 0.96. However, this accounted solely for the experienced head and neck radiologist in a series with higher prevalence of metastases (27.2%) and larger assessed lymph nodes (18% > 10 mm) [33].
×
×
The chosen ADC threshold of 1.0 × 10−3 mm2/s in this study might be difficult to reproduce in other centers. This is probably based on the differences in study design and techniques that will be used and differences in selection of patient series, i.e., the sizes of assessed lymph nodes might influence the choice of the ADC threshold as larger lymph nodes tend to show necrosis and this will affect the ADC values. To use DWI for characterizing lymph nodes in general practice, there should be a well-established threshold for the ADC values. It is advisable that thresholds are reproducible in different centers and on different MR machines, to set the ADC threshold to the proper value depends on the differential diagnosis of expected lymph node pathology.
Some limitations of this study have to be addressed. Firstly, the low prevalence of malignant lymph nodes, with as a result that the negative predictive values were high for all MRI criteria. It must be kept in mind that predictive values are not independent of the setting in which the test is used and are strongly influenced by the prevalence; metastases were present in only 26 out of 219 lymph nodes and negative predictive values of tests tend to be high when applied in a population with a low likelihood of the disease. It also has to be mentioned that the primary tumor sites in this study, which are relatively more likely to show small metastases, have been of influence especially on the size criterion showing low diagnostic accuracy and additional value. Secondly, in nine out of 45 lymph nodes (20%) with a size of 3–4 mm in maximum short axial diameter, ADC values were observed below the threshold of 1.0 × 10−3 mm2/s. None of these small lymph nodes showed histopathological evidence of metastasis; partial volume effect when drawing ROIs on the b1000 images around these small lymph nodes might be responsible for the false positive results. Thirdly, although the scan time of DWI will only take less than 5 min, it must be said that evaluating all lymph nodes at the MR workstation is time consuming.
Conclusions
We demonstrated in a series with predominantly small lymph nodes that ADC values calculated on the diffusion-weighted MRI is a strong predictor of the presence of metastasis, independently from other predictor such as size and morphology, in patients with head and neck squamous cell carcinoma (HNSCC). The use of ADC values in combination with the other MRI criteria significantly improves the discrimination between malignant and benign lymph nodes.
Conflict of interest statement
We declare that we have no conflict of interest.
Open Access
This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.
Open AccessThis is an open access article distributed under the terms of the Creative Commons Attribution Noncommercial License (https://creativecommons.org/licenses/by-nc/2.0), which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.
Mit e.Med Neurologie & Psychiatrie erhalten Sie Zugang zu CME-Fortbildungen der Fachgebiete, den Premium-Inhalten der dazugehörigen Fachzeitschriften, inklusive einer gedruckten Zeitschrift Ihrer Wahl.
Mit e.Med Neurologie erhalten Sie Zugang zu CME-Fortbildungen des Fachgebietes, den Premium-Inhalten der neurologischen Fachzeitschriften, inklusive einer gedruckten Neurologie-Zeitschrift Ihrer Wahl.
Mit e.Med Radiologie erhalten Sie Zugang zu CME-Fortbildungen des Fachgebietes Radiologie, den Premium-Inhalten der radiologischen Fachzeitschriften, inklusive einer gedruckten Radiologie-Zeitschrift Ihrer Wahl.
Diagnostic accuracy and additional value of diffusion-weighted imaging for discrimination of malignant cervical lymph nodes in head and neck squamous cell carcinoma
verfasst von
R. B. J. de Bondt M. C. Hoeberigs P. J. Nelemans W. M. L. L. G. Deserno C. Peutz-Kootstra B. Kremer R. G. H. Beets-Tan
Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.
Wenn unter einer medikamentösen Hochdrucktherapie der diastolische Blutdruck in den Keller geht, steigt das Risiko für schwere kardiovaskuläre Ereignisse: Darauf deutet eine Sekundäranalyse der SPRINT-Studie hin.
Ist die Tau-Last noch gering, scheint der Vorteil von Lecanemab besonders groß zu sein. Und beginnen Erkrankte verzögert mit der Behandlung, erreichen sie nicht mehr die kognitive Leistung wie bei einem früheren Start. Darauf deuten neue Analysen der Phase-3-Studie Clarity AD.
Neue arznei- und zellbasierte Ansätze, Frühdiagnose mit Bewegungssensoren, Rückenmarkstimulation gegen Gehblockaden – in der Parkinsonforschung tut sich einiges. Auf dem Deutschen Parkinsonkongress ging es auch viel um technische Innovationen.
Update Neurologie
Bestellen Sie unseren Fach-Newsletterund bleiben Sie gut informiert.