Introduction

This study aims to assess the accuracy of digital templating for hip hemiarthroplasty using radiographs without calibration.

Methods

Two independent, blinded observers retrospectively utilised digital software to template 50 consecutive patients who had hip hemiarthroplasty. The templated parameters (head size, offset and stem size) derived from pre-operative radiographs were compared to the actual prosthetic sizes used intra-operatively. Inter and intra-observer variabilities were calculated.

Results

Both observers correctly templated the offset and head size (± 2 mm) used in 90% (n = 45) of cases. The femoral stem size (± 1 size) was correctly predicted by templating in over 84% of the cases (n = 42). Inter-observer agreement was excellent for femoral head size with an intra-class correlation coefficients (ICC) of 0.94, substantial for offset (k = 0.7) but only fair for stem size (k = 0.27). ICC values comparing the actual prostheses inserted with the template values were excellent for head size (ICC = 0.96), substantial to near perfect for offset (k = 0.78, 0.85) and fair to moderate (k = 0.24, 0.45) for stem size.

Conclusion

Digital templating of radiographs without calibration can be used to accurately and reliably predict femoral head size and offset at a set magnification of 120%. Femoral stem size, however, is more difficult to template adequately on pre-operative radiographs without calibration.
Literatur
1.
Zurück zum Zitat Della Valle AG, Comba F, Taveras N, Salvati EA. The utility and precision of analogue and digital preoperative planning for total hip arthroplasty. Int Orthop. 2008;32(3):289–94.CrossRef Della Valle AG, Comba F, Taveras N, Salvati EA. The utility and precision of analogue and digital preoperative planning for total hip arthroplasty. Int Orthop. 2008;32(3):289–94.CrossRef
2.
Zurück zum Zitat Whiddon DR, Bono JV, Lang JE, Smith EL, Salyapongse AK. Accuracy of digital templating in total hip arthroplasty. Am J Orthop (Belle Mead NJ). 2011;40(8):395–8. Whiddon DR, Bono JV, Lang JE, Smith EL, Salyapongse AK. Accuracy of digital templating in total hip arthroplasty. Am J Orthop (Belle Mead NJ). 2011;40(8):395–8.
3.
Zurück zum Zitat Iorio R, Siegel J, Specht LM, Tilzey JF, Hartman A, Healy WL. A comparison of acetate vs digital templating for preoperative planning of total hip arthroplasty: is digital templating accurate and safe? J Arthroplasty. 2009;24(2):175–9.CrossRef Iorio R, Siegel J, Specht LM, Tilzey JF, Hartman A, Healy WL. A comparison of acetate vs digital templating for preoperative planning of total hip arthroplasty: is digital templating accurate and safe? J Arthroplasty. 2009;24(2):175–9.CrossRef
4.
Zurück zum Zitat Gamble P, Beer J, Petruccelli D, Winemaker M. The accuracy of digital templating in uncemented total hip arthroplasty. J Arthroplasty. 2010;25(4):529–32.CrossRef Gamble P, Beer J, Petruccelli D, Winemaker M. The accuracy of digital templating in uncemented total hip arthroplasty. J Arthroplasty. 2010;25(4):529–32.CrossRef
5.
Zurück zum Zitat Sinclair VF, Wilson J, Jain NP, Knowles D. Assessment of accuracy of marker ball placement in pre-operative templating for total hip arthroplasty. J Arthroplasty. 2014;29(8):1658–60.CrossRef Sinclair VF, Wilson J, Jain NP, Knowles D. Assessment of accuracy of marker ball placement in pre-operative templating for total hip arthroplasty. J Arthroplasty. 2014;29(8):1658–60.CrossRef
6.
Zurück zum Zitat Carroll C, Stevenson M, Scope A, Evans P, Buckley S. Hemiarthroplasty and total hip arthroplasty for treating primary intracapsular fracture of the hip: a systematic review and cost-effectiveness analysis. Health Technol Assess. 2011;15:36. Carroll C, Stevenson M, Scope A, Evans P, Buckley S. Hemiarthroplasty and total hip arthroplasty for treating primary intracapsular fracture of the hip: a systematic review and cost-effectiveness analysis. Health Technol Assess. 2011;15:36.
7.
Zurück zum Zitat Van der Meulen, et.al. (1996) Effect of hemiarthroplasty on acetabular cartilage. Project Reports. VA Palo Alto Health Care System’s Bone and Joint Rehabilitation Research and Development Centre. Van der Meulen, et.al. (1996) Effect of hemiarthroplasty on acetabular cartilage. Project Reports. VA Palo Alto Health Care System’s Bone and Joint Rehabilitation Research and Development Centre.
8.
Zurück zum Zitat White SP, Shardlow DL. Effect of introduction of digital radiographic techniques on pre-operative templating in orthopaedic practice. Ann R Coll Surg Engl. 2009;87:53–4.CrossRef White SP, Shardlow DL. Effect of introduction of digital radiographic techniques on pre-operative templating in orthopaedic practice. Ann R Coll Surg Engl. 2009;87:53–4.CrossRef
9.
Zurück zum Zitat Franken M, Grimm B, Heyligers I. A comparison of four systems for calibration when templating for total hip replacement with digital radiography. J Bone Joint Surg (Br). 2010;92:136–41.CrossRef Franken M, Grimm B, Heyligers I. A comparison of four systems for calibration when templating for total hip replacement with digital radiography. J Bone Joint Surg (Br). 2010;92:136–41.CrossRef
10.
Zurück zum Zitat Eggli S, Pisan M, Muller ME. The value of preoperative planning for total hip arthroplasty. J Bone Joint Surg Br. 1998;80(3):382–90.CrossRef Eggli S, Pisan M, Muller ME. The value of preoperative planning for total hip arthroplasty. J Bone Joint Surg Br. 1998;80(3):382–90.CrossRef
11.
Zurück zum Zitat Schmidutz F, Steinbrück A, Wanke-Jellinek L, Pietschmann M, Jansson V, Fottner A. The accuracy of digital templating: a comparison of short-stem total hip arthroplasty and conventional total hip arthroplasty. Int Orthop. 2012;36(9):1767–72.CrossRef Schmidutz F, Steinbrück A, Wanke-Jellinek L, Pietschmann M, Jansson V, Fottner A. The accuracy of digital templating: a comparison of short-stem total hip arthroplasty and conventional total hip arthroplasty. Int Orthop. 2012;36(9):1767–72.CrossRef
12.
Zurück zum Zitat Jassim SS, Ingham C, Keeling M, Wimhurst JA. Digital templating facilitates accurate leg length correction in total hip arthroplasty. Acta Orthop Belg. 2012;78(3):344–9.PubMed Jassim SS, Ingham C, Keeling M, Wimhurst JA. Digital templating facilitates accurate leg length correction in total hip arthroplasty. Acta Orthop Belg. 2012;78(3):344–9.PubMed
13.
Zurück zum Zitat Descamps S, Livesey C, Learmonth ID. Determination of digitized radiograph magnification factors for pre-operative templating in hip prosthesis surgery. Skeletal Radiol. 2010;9:273–7.CrossRef Descamps S, Livesey C, Learmonth ID. Determination of digitized radiograph magnification factors for pre-operative templating in hip prosthesis surgery. Skeletal Radiol. 2010;9:273–7.CrossRef
14.
Zurück zum Zitat Oddy MJ, Jones MJ, Pendegrass CJ, Pilling JR, Wimhurst JA. Assessment of reproducibility and accuracy in templating hybrid total hip arthroplasty using digital radiographs. J Bone Joint Surg Br. 2006;88:581–5.CrossRef Oddy MJ, Jones MJ, Pendegrass CJ, Pilling JR, Wimhurst JA. Assessment of reproducibility and accuracy in templating hybrid total hip arthroplasty using digital radiographs. J Bone Joint Surg Br. 2006;88:581–5.CrossRef
15.
Zurück zum Zitat Wimsey S, Pickard R, Shaw G. Accurate scaling of digital radiographs of the pelvis: a prospective trial of two methods. J Bone Joint Surg Br. 2006;88-B:1508–12.CrossRef Wimsey S, Pickard R, Shaw G. Accurate scaling of digital radiographs of the pelvis: a prospective trial of two methods. J Bone Joint Surg Br. 2006;88-B:1508–12.CrossRef
16.
Zurück zum Zitat Kulkarni A, Partington P, Kelly D, Muller S. Disc calibration for digital templating in hip replacement. J Bone Joint Surg Br. 2008;90-B:1623–6.CrossRef Kulkarni A, Partington P, Kelly D, Muller S. Disc calibration for digital templating in hip replacement. J Bone Joint Surg Br. 2008;90-B:1623–6.CrossRef
17.
Zurück zum Zitat King RJ, Craig PR, Boreham BG, Majeed MA, Moran CG. The magnification of digital radiographs in the trauma patient: Implications for templating. Injury. 2009;40(2):173–6.CrossRef King RJ, Craig PR, Boreham BG, Majeed MA, Moran CG. The magnification of digital radiographs in the trauma patient: Implications for templating. Injury. 2009;40(2):173–6.CrossRef
18.
Zurück zum Zitat White SP, Bainbridge J, Smith EJ. Assessment of magnification of digital pelvic radiographs in total hip arthroplasty using templating software. Ann R Coll Surg Engl. 2008;90(7):592–6.CrossRef White SP, Bainbridge J, Smith EJ. Assessment of magnification of digital pelvic radiographs in total hip arthroplasty using templating software. Ann R Coll Surg Engl. 2008;90(7):592–6.CrossRef
19.
Zurück zum Zitat Riddick A, Smith A, Thomas DP. Accuracy of preoperative templating in total hip arthroplasty. J Orthop Surg. 2014;22(2):173–6.CrossRef Riddick A, Smith A, Thomas DP. Accuracy of preoperative templating in total hip arthroplasty. J Orthop Surg. 2014;22(2):173–6.CrossRef
20.
Zurück zum Zitat Boese CK, Lechler P, Rose L, Dargel J, Oppermann J, Eysel P, et al. Calibration markers for digital templating in total hip arthroplasty. PLoS One. 2015;10(7):e0128529.CrossRef Boese CK, Lechler P, Rose L, Dargel J, Oppermann J, Eysel P, et al. Calibration markers for digital templating in total hip arthroplasty. PLoS One. 2015;10(7):e0128529.CrossRef
25.
Zurück zum Zitat Mittag F, Ipach I, Schaefer R, Meisner C, Leichtle U. Predictive value of preoperative digital templating in THA depends on the surgical experience of the performing physician. Orthopedics. 2012;35:144–7. Mittag F, Ipach I, Schaefer R, Meisner C, Leichtle U. Predictive value of preoperative digital templating in THA depends on the surgical experience of the performing physician. Orthopedics. 2012;35:144–7.
26.
Zurück zum Zitat Steinberg EL, Shasha N, Menahem A, Dekel S. Preoperative planning of total hip replacement using TraumaCad™ system. Arch Orthop Trauma Surg. 2010;130:1429.CrossRef Steinberg EL, Shasha N, Menahem A, Dekel S. Preoperative planning of total hip replacement using TraumaCad™ system. Arch Orthop Trauma Surg. 2010;130:1429.CrossRef
27.
Zurück zum Zitat Marcucci M, Indelli PF, Latella L, Poli P, King D. A multimodal approach in total hip arthroplasty preoperative templating. Skelet Radiol. 2013;42:1287–94.CrossRef Marcucci M, Indelli PF, Latella L, Poli P, King D. A multimodal approach in total hip arthroplasty preoperative templating. Skelet Radiol. 2013;42:1287–94.CrossRef
28.
Zurück zum Zitat Unnanuntana A, Wagner D, Goodman SB. The accuracy of preoperative templating in cementless total hip arthroplasty. J Arthroplasty. 2009;24(2):180.CrossRef Unnanuntana A, Wagner D, Goodman SB. The accuracy of preoperative templating in cementless total hip arthroplasty. J Arthroplasty. 2009;24(2):180.CrossRef
29.
Zurück zum Zitat Sariali E, Mauprivez R, Khiami F, et al. Accuracy of the preoperative planning for cementless total hip arthroplasty. A randomised comparison between three- dimensional computerised planning and conventional templating. Orthop Traumatol Surg Res. 2012;98(2):151.CrossRef Sariali E, Mauprivez R, Khiami F, et al. Accuracy of the preoperative planning for cementless total hip arthroplasty. A randomised comparison between three- dimensional computerised planning and conventional templating. Orthop Traumatol Surg Res. 2012;98(2):151.CrossRef
30.
Zurück zum Zitat Bartoníček J, et al. Hemiarthroplasty for displaced intracapsular femoral neck fractures. Osteo Trauma Care. 2005;13(4):214–8.CrossRef Bartoníček J, et al. Hemiarthroplasty for displaced intracapsular femoral neck fractures. Osteo Trauma Care. 2005;13(4):214–8.CrossRef
Metadaten
Titel
Digital templating without a calibration marker is accurate at predicting implant size for hip hemiarthroplasty
verfasst von
Mina Derias
Muhammad A. Khan
Jamie Buchanan
Publikationsdatum
12.09.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
European Journal of Trauma and Emergency Surgery / Ausgabe 1/2020
Print ISSN: 1863-9933
Elektronische ISSN: 1863-9941
DOI
https://doi.org/10.1007/s00068-018-0994-8

Weitere Artikel der Ausgabe 1/2020

European Journal of Trauma and Emergency Surgery 1/2020 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Aquatherapie bei Fibromyalgie wirksamer als Trockenübungen

03.05.2024 Fibromyalgiesyndrom Nachrichten

Bewegungs-, Dehnungs- und Entspannungsübungen im Wasser lindern die Beschwerden von Patientinnen mit Fibromyalgie besser als das Üben auf trockenem Land. Das geht aus einer spanisch-brasilianischen Vergleichsstudie hervor.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.