Skip to main content
Erschienen in: International Orthopaedics 2/2014

01.02.2014 | Original Paper

Does computer-assisted total knee arthroplasty improve the overall component position and patient function?

verfasst von: Charlotte L. Allen, Gary J. Hooper, Byron J. Oram, J. Elizabeth Wells

Erschienen in: International Orthopaedics | Ausgabe 2/2014

Einloggen, um Zugang zu erhalten

Abstract

Purpose

There remains controversy as to whether computer-navigated total knee replacement (TKR) improves the overall prosthesis alignment and patient function. The aim of this study was to determine whether computer-assisted total knee arthroplasty provides superior prosthesis positioning when compared to a conventional jig-assisted total knee replacement and whether this affected the functional outcome.

Methods

This prospective, randomised controlled study compared computer navigated and conventional jig-assisted total knee replacement in 37 patients who underwent bilateral TKR. A quantitative assessment of the spatial positioning of the implant in the 74 total knee replacements was determined using a low-dose dual-beam CT scanning technique. This resulted in six parameters of alignment that were compared. Functional outcomes using the high activity arthroplasty score and Knee Society score were assessed pre-operatively, postoperatively, at three years and at five years. Patients also indicated which knee they felt was subjectively the best.

Results

There was no statistically significant difference in the prosthesis alignment between both groups and the number of outliers was not decreased with navigation. All function scores improved from pre-operative to postoperative but there was no statistically significant difference between the groups at five years. At five years, 40.6 % of patients thought their jig-assisted knee was the better knee compared with 21.9 % their computer assisted knee and 37.5 % of patients who felt they were the same.

Conclusion

Computer-assisted implantation of total knee replacements does not offer a significant advantage in prosthesis alignment. There was no difference in functional outcome or subjective “best knee” between the computer-assisted or jig-assisted knee.
Literatur
1.
Zurück zum Zitat Wasiliewski RC et al (1995) Wear patterns on retrieved polyethylene inserts and their relationship to technical considerations during total knee arthroplasty. Clin Orthop 318:176–181 Wasiliewski RC et al (1995) Wear patterns on retrieved polyethylene inserts and their relationship to technical considerations during total knee arthroplasty. Clin Orthop 318:176–181
2.
Zurück zum Zitat Moreland JR (1988) Mechanisms of failure in total knee arthroplasty. Clin Orthop Relat Res 266:49–64 Moreland JR (1988) Mechanisms of failure in total knee arthroplasty. Clin Orthop Relat Res 266:49–64
3.
Zurück zum Zitat Lotke PA, Ecker ML (1977) Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg Am 59:77–79PubMed Lotke PA, Ecker ML (1977) Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg Am 59:77–79PubMed
4.
Zurück zum Zitat Ritter MA et al (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop Relat Res 299:153–156PubMed Ritter MA et al (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop Relat Res 299:153–156PubMed
5.
Zurück zum Zitat Berend ME et al (2004) Tibial component failure mechanisms in total knee arthroplasty. Clin Orthop Relat Res 428:26–34PubMedCrossRef Berend ME et al (2004) Tibial component failure mechanisms in total knee arthroplasty. Clin Orthop Relat Res 428:26–34PubMedCrossRef
6.
Zurück zum Zitat Jeffery RS et al (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73:709–714PubMed Jeffery RS et al (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73:709–714PubMed
7.
Zurück zum Zitat Rienmüller A, Guggi T, Gruber G, Preiss S, Drobny T (2012) The effect of femoral component rotation on the five-year outcome of cemented mobile bearing total knee arthroplasty. Int Orthop 36(10):2067–2072PubMedCentralPubMedCrossRef Rienmüller A, Guggi T, Gruber G, Preiss S, Drobny T (2012) The effect of femoral component rotation on the five-year outcome of cemented mobile bearing total knee arthroplasty. Int Orthop 36(10):2067–2072PubMedCentralPubMedCrossRef
8.
Zurück zum Zitat Choong PF, Dowsey MM, Stoney JD (2009) Does accurate anatomical alignment result in better function and quality of life? comparing conventional and computer-assisted total knee arthroplasty. J Arthroplasty 24:560–569PubMedCrossRef Choong PF, Dowsey MM, Stoney JD (2009) Does accurate anatomical alignment result in better function and quality of life? comparing conventional and computer-assisted total knee arthroplasty. J Arthroplasty 24:560–569PubMedCrossRef
9.
Zurück zum Zitat Sparman M et al (2003) Positioning of total knee arthroplasty with and without navigation support. A prospective, randomised study. J Bone Joint Surg Br 85:830–835 Sparman M et al (2003) Positioning of total knee arthroplasty with and without navigation support. A prospective, randomised study. J Bone Joint Surg Br 85:830–835
10.
Zurück zum Zitat Stulberg SD et al (2002) Computer-assisted navigation in total knee replacement: results of an initial experience in thirty-five patients. J Bone Joint Surg Am 84(Suppl 2):90–98PubMed Stulberg SD et al (2002) Computer-assisted navigation in total knee replacement: results of an initial experience in thirty-five patients. J Bone Joint Surg Am 84(Suppl 2):90–98PubMed
11.
Zurück zum Zitat Chin PL et al (2005) Randomised control trial comparing radiographic total knee arthroplasty implant placement using computer navigation versus conventional technique. J Arthroplasty 20:618–626PubMedCrossRef Chin PL et al (2005) Randomised control trial comparing radiographic total knee arthroplasty implant placement using computer navigation versus conventional technique. J Arthroplasty 20:618–626PubMedCrossRef
12.
Zurück zum Zitat Bathis H et al (2004) Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique. J Bone Joint Surg Br 86:682–687PubMedCrossRef Bathis H et al (2004) Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique. J Bone Joint Surg Br 86:682–687PubMedCrossRef
13.
Zurück zum Zitat Haaker RG, Stockheim M, Kamp M, Proff G, Breitenfelder J, Ottersbach A (2005) Computer-assisted navigation increases precision of component placement in total knee arthroplasty. Clin Orthop Relat Res 433:152–159PubMedCrossRef Haaker RG, Stockheim M, Kamp M, Proff G, Breitenfelder J, Ottersbach A (2005) Computer-assisted navigation increases precision of component placement in total knee arthroplasty. Clin Orthop Relat Res 433:152–159PubMedCrossRef
14.
Zurück zum Zitat Chauhan S, Scott R, Breidahl W, Beaver R (2004) Computer-assisted knee arthroplasty versus a conventional jig-based technique: a randomised, prospective trial. J Bone Joint Surg Br 86-B:372–377CrossRef Chauhan S, Scott R, Breidahl W, Beaver R (2004) Computer-assisted knee arthroplasty versus a conventional jig-based technique: a randomised, prospective trial. J Bone Joint Surg Br 86-B:372–377CrossRef
15.
Zurück zum Zitat Zhang G, Chen J, Chai W, Liu M, Wang Y (2011) Comparison between computer-assisted-navigation and conventional total knee arthroplasties in patients undergoing simultaneous bilateral procedures—a randomized clinical trial. J Bone Joint Surg Am 93(13):1190–1196PubMedCrossRef Zhang G, Chen J, Chai W, Liu M, Wang Y (2011) Comparison between computer-assisted-navigation and conventional total knee arthroplasties in patients undergoing simultaneous bilateral procedures—a randomized clinical trial. J Bone Joint Surg Am 93(13):1190–1196PubMedCrossRef
16.
Zurück zum Zitat Mason J, Fehring T, Estok R, Banel D, Fahrbach K (2007) Meta-analysis of alignment outcomes in computer-assisted total knee arthroplasty surgery. J Arthroplasty 22(8):1097–1106PubMedCrossRef Mason J, Fehring T, Estok R, Banel D, Fahrbach K (2007) Meta-analysis of alignment outcomes in computer-assisted total knee arthroplasty surgery. J Arthroplasty 22(8):1097–1106PubMedCrossRef
17.
Zurück zum Zitat Yi-Jan Weng MD, Robert Wen-Wei Hsu MD, Wei-Hsiu Hsu MD (2009) Comparison of computer-assisted navigation and conventional instrumentation for bilateral total knee arthroplasty. J Arthroplasty 24(5):668–673PubMedCrossRef Yi-Jan Weng MD, Robert Wen-Wei Hsu MD, Wei-Hsiu Hsu MD (2009) Comparison of computer-assisted navigation and conventional instrumentation for bilateral total knee arthroplasty. J Arthroplasty 24(5):668–673PubMedCrossRef
18.
Zurück zum Zitat Kim Y, Kim J, Choi Y, Kwon O (2009) Computer-assisted surgical navigation does not improve the alignment and orientation of the components in total knee arthroplasty. J Bone Joint Surg Am 91(1):14–19PubMedCrossRef Kim Y, Kim J, Choi Y, Kwon O (2009) Computer-assisted surgical navigation does not improve the alignment and orientation of the components in total knee arthroplasty. J Bone Joint Surg Am 91(1):14–19PubMedCrossRef
19.
Zurück zum Zitat Parratte S, Pagnano MW, Trousdale RT, Berry DJ (2010) Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements. J Bone Joint Surg Am 92(12):2143–2149PubMedCrossRef Parratte S, Pagnano MW, Trousdale RT, Berry DJ (2010) Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements. J Bone Joint Surg Am 92(12):2143–2149PubMedCrossRef
20.
Zurück zum Zitat Kim YH, Park JW, Kim JS (2012) Computer-navigated versus conventional total knee arthroplasty. A prospective randomized trial. J Bone Joint Surg Am 94:2017–2024PubMedCrossRef Kim YH, Park JW, Kim JS (2012) Computer-navigated versus conventional total knee arthroplasty. A prospective randomized trial. J Bone Joint Surg Am 94:2017–2024PubMedCrossRef
21.
Zurück zum Zitat Cinotti G, Ripani F, Sessa P, Giannicola G (2012) Combining different rotational alignment axes with navigation may reduce the need for lateral retinacular release in total knee arthroplasty. Int Orthop 36(8):1595–1600PubMedCentralPubMedCrossRef Cinotti G, Ripani F, Sessa P, Giannicola G (2012) Combining different rotational alignment axes with navigation may reduce the need for lateral retinacular release in total knee arthroplasty. Int Orthop 36(8):1595–1600PubMedCentralPubMedCrossRef
22.
Zurück zum Zitat Saragaglia D, Picard F, Chaussard C, Montbarbon E, Leitner F, Cinquin P (2001) Computer-assisted knee arthroplasty: comparison with a conventional procedure. Results of 50 cases in a prospective randomized study. Rev Chir Orthop Reparatrice Appar Mot 87(1):18–28PubMed Saragaglia D, Picard F, Chaussard C, Montbarbon E, Leitner F, Cinquin P (2001) Computer-assisted knee arthroplasty: comparison with a conventional procedure. Results of 50 cases in a prospective randomized study. Rev Chir Orthop Reparatrice Appar Mot 87(1):18–28PubMed
23.
Zurück zum Zitat Koshino T, Takeyama M, Jiang LS, Yoshida T, Saito T (2002) Underestimation of varus angulation in knees with flexion deformity. Knee 9:275–279PubMedCrossRef Koshino T, Takeyama M, Jiang LS, Yoshida T, Saito T (2002) Underestimation of varus angulation in knees with flexion deformity. Knee 9:275–279PubMedCrossRef
24.
Zurück zum Zitat Krackow KA, Pepe CL, Galloway EJ (1990) A mathematical analysis of the effect of flexion and rotation on apparent varus/valgus alignment at the knee. Orthopaedics 13:861–868 Krackow KA, Pepe CL, Galloway EJ (1990) A mathematical analysis of the effect of flexion and rotation on apparent varus/valgus alignment at the knee. Orthopaedics 13:861–868
25.
Zurück zum Zitat Kawakami H, Sugano N, Yonenobu K, Yoshikawa H, Ochi T, Hattori A, Suzuki N (2004) Effects of rotation on measurement of lower limb alignment for knee osteotomy. J Othop Res 22:1248–1253CrossRef Kawakami H, Sugano N, Yonenobu K, Yoshikawa H, Ochi T, Hattori A, Suzuki N (2004) Effects of rotation on measurement of lower limb alignment for knee osteotomy. J Othop Res 22:1248–1253CrossRef
26.
Zurück zum Zitat Henckel J, Richards R, Lozhkin K, Harris S, Baena FM R y, Barret ARW, Cobb JP (2006) Very low-dose computed tomography for planning and outcome measurement in knee replacement—the imperial knee protocol. J Bone Joint Surg Br 88-B:1513–1518CrossRef Henckel J, Richards R, Lozhkin K, Harris S, Baena FM R y, Barret ARW, Cobb JP (2006) Very low-dose computed tomography for planning and outcome measurement in knee replacement—the imperial knee protocol. J Bone Joint Surg Br 88-B:1513–1518CrossRef
27.
Zurück zum Zitat Chauhan SK, Clark GW, Lloyd S, Scott RG, Breidahl W, Sikorski JM (2004) Computer-assisted total knee replacement. A controlled cadaver study using a multi-parameter quantitative CT assessment of alignment (The Perth CT protocol). J Bone Joint Surg Br 86-B:818–823CrossRef Chauhan SK, Clark GW, Lloyd S, Scott RG, Breidahl W, Sikorski JM (2004) Computer-assisted total knee replacement. A controlled cadaver study using a multi-parameter quantitative CT assessment of alignment (The Perth CT protocol). J Bone Joint Surg Br 86-B:818–823CrossRef
28.
Zurück zum Zitat Matziolis G, Krocker D, Weiss U, Tohtz S, Perka C (2007) A prospective, randomised study of computer-assisted and conventional total knee arthroplasty. Three dimensional evaluation of implant alignment and rotation. J Bone Joint Surg Am 89:236–243PubMedCrossRef Matziolis G, Krocker D, Weiss U, Tohtz S, Perka C (2007) A prospective, randomised study of computer-assisted and conventional total knee arthroplasty. Three dimensional evaluation of implant alignment and rotation. J Bone Joint Surg Am 89:236–243PubMedCrossRef
29.
Zurück zum Zitat Talbot S, Hooper G, Stokes A, Zordan R (2010) Use of a new high-activity arthroplasty score to assess function of young patients with total hip or knee arthroplasty. J Arthroplasty 25(2):268–273PubMedCrossRef Talbot S, Hooper G, Stokes A, Zordan R (2010) Use of a new high-activity arthroplasty score to assess function of young patients with total hip or knee arthroplasty. J Arthroplasty 25(2):268–273PubMedCrossRef
30.
Zurück zum Zitat Armitage P, Berry G, Mathews J (2002) Statistical methods in medical research. Oxford, Blackwell Armitage P, Berry G, Mathews J (2002) Statistical methods in medical research. Oxford, Blackwell
31.
Zurück zum Zitat Tigani D, Masetti G, Sabbioni G, Ben Ayad R, Filanti M, Fosco M (2012) Computer-assisted surgery as indication of choice: total knee arthroplasty in case of retained hardware or extra-articular deformity. Int Orthop 36(7):1379–1385PubMedCentralPubMedCrossRef Tigani D, Masetti G, Sabbioni G, Ben Ayad R, Filanti M, Fosco M (2012) Computer-assisted surgery as indication of choice: total knee arthroplasty in case of retained hardware or extra-articular deformity. Int Orthop 36(7):1379–1385PubMedCentralPubMedCrossRef
32.
Zurück zum Zitat Ritter M, Davis K, Davis P, Farris A, Malinzak R, Berend M, Meding J (2013) Preoperative malalignment increases risk of failure after total knee arthroplasty. J Bone Joint Surg Am 95(2):126–131PubMedCrossRef Ritter M, Davis K, Davis P, Farris A, Malinzak R, Berend M, Meding J (2013) Preoperative malalignment increases risk of failure after total knee arthroplasty. J Bone Joint Surg Am 95(2):126–131PubMedCrossRef
Metadaten
Titel
Does computer-assisted total knee arthroplasty improve the overall component position and patient function?
verfasst von
Charlotte L. Allen
Gary J. Hooper
Byron J. Oram
J. Elizabeth Wells
Publikationsdatum
01.02.2014
Verlag
Springer Berlin Heidelberg
Erschienen in
International Orthopaedics / Ausgabe 2/2014
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-013-1996-0

Weitere Artikel der Ausgabe 2/2014

International Orthopaedics 2/2014 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.