19.01.2018 | Original Article

Dose optimization of total or partial skin electron irradiation by thermoluminescent dosimetry

verfasst von: Lars Schüttrumpf, Klement Neumaier, Cornelius Maihoefer, Maximilian Niyazi, Ute Ganswindt, Minglun Li, Peter Lang, Michael Reiner, Claus Belka, Dr. med. Stefanie Corradini

Erschienen in: Strahlentherapie und Onkologie | Ausgabe 5/2018

Einloggen, um Zugang zu erhalten

Abstract

Background

Due to the complex surface of the human body, total or partial skin irradiation using large electron fields is challenging. The aim of the present study was to quantify the magnitude of dose optimization required after the application of standard fields.

Methods

Total skin electron irradiation (TSEI) was applied using the Stanford technique with six dual-fields. Patients presenting with localized lesions were treated with partial skin electron irradiation (PSEI) using large electron fields, which were individually adapted. In order to verify and validate the dose distribution, in vivo dosimetry with thermoluminescent dosimeters (TLD) was performed during the first treatment fraction to detect potential dose heterogeneity and to allow for an individual dose optimization with adjustment of the monitor units (MU).

Results

Between 1984 and 2017, a total of 58 patients were treated: 31 patients received TSEI using 12 treatment fields, while 27 patients underwent PSEI and were treated with 4–8 treatment fields. After evaluation of the dosimetric results, an individual dose optimization was necessary in 21 patients. Of these, 7 patients received TSEI (7/31). Monitor units (MU) needed to be corrected by a mean value of 117 MU (±105, range 18–290) uniformly for all 12 treatment fields, corresponding to a mean relative change of 12% of the prescribed MU. In comparison, the other 14 patients received PSEI (14/27) and the mean adjustment of monitor units was 282 MU (±144, range 59–500) to single or multiple fields, corresponding to a mean relative change of 22% of the prescribed MU. A second dose optimization to obtain a satisfying dose at the prescription point was need in 5 patients.

Conclusions

Thermoluminescent dosimetry allows an individual dose optimization in TSEI and PSEI to enable a reliable adjustment of the MUs to obtain the prescription dose. Especially in PSEI in vivo dosimetry is of fundamental importance.
Literatur
1.
Zurück zum Zitat Jones GW, Kacinski BM, Wilson LD, Willemze R, Spittle M, Hohenberg G, Handl-Zeller L, Trautinger F, Knobler R (2002) Total skin electron radiation in the management of mycosis fungoides: Consensus of the European Organization for Research and Treatment of Cancer (EORTC) Cutaneous Lymphoma Project Group. J Am Acad Dermatol 47:364–370CrossRefPubMed Jones GW, Kacinski BM, Wilson LD, Willemze R, Spittle M, Hohenberg G, Handl-Zeller L, Trautinger F, Knobler R (2002) Total skin electron radiation in the management of mycosis fungoides: Consensus of the European Organization for Research and Treatment of Cancer (EORTC) Cutaneous Lymphoma Project Group. J Am Acad Dermatol 47:364–370CrossRefPubMed
7.
Zurück zum Zitat Reynard EP, Evans MDC, Devic S, Parker W, Freeman CR, Roberge D, Podgorsak EB (2008) Rotational total skin electron irradiation with a linear accelerator. J Appl Clin Med Phys 9:2793CrossRefPubMed Reynard EP, Evans MDC, Devic S, Parker W, Freeman CR, Roberge D, Podgorsak EB (2008) Rotational total skin electron irradiation with a linear accelerator. J Appl Clin Med Phys 9:2793CrossRefPubMed
8.
Zurück zum Zitat Peters VG, Jaywant SM (1995) Implementation of total skin electron therapy using an optional high dose rate mode on a conventional linear accelerator. Med Dosim 20:99–104CrossRefPubMed Peters VG, Jaywant SM (1995) Implementation of total skin electron therapy using an optional high dose rate mode on a conventional linear accelerator. Med Dosim 20:99–104CrossRefPubMed
10.
Zurück zum Zitat Feist H, Rohloff R, Wiesmeth A, Willich N, Wendt Th, Burg G (1987) Dosimetry and first clinical results of total skin electron beam therapy of cutaneous T cell lymphomas. Strahlenther Onkol 163:273–274 Feist H, Rohloff R, Wiesmeth A, Willich N, Wendt Th, Burg G (1987) Dosimetry and first clinical results of total skin electron beam therapy of cutaneous T cell lymphomas. Strahlenther Onkol 163:273–274
11.
Zurück zum Zitat Horowitz YS, Moscovitch M (2013) Highlights and pitfalls of 20 years of application of computerised glow curve analysis to thermoluminescence research and dosimetry. Radiat Prot Dosimetry 153:1–22CrossRefPubMed Horowitz YS, Moscovitch M (2013) Highlights and pitfalls of 20 years of application of computerised glow curve analysis to thermoluminescence research and dosimetry. Radiat Prot Dosimetry 153:1–22CrossRefPubMed
12.
Zurück zum Zitat Kim YH, Jensen RA, Watanabe GL, Varghese A, Hoppe RT (1996) Clinical stage IA (limited patch and plaque) mycosis fungoides. A long-term outcome analysis. Arch Dermatol 132:1309–1313CrossRefPubMed Kim YH, Jensen RA, Watanabe GL, Varghese A, Hoppe RT (1996) Clinical stage IA (limited patch and plaque) mycosis fungoides. A long-term outcome analysis. Arch Dermatol 132:1309–1313CrossRefPubMed
16.
Zurück zum Zitat Hoppe RT, Harrison C, Tavallaee M, Bashey S, Sundram U, Shufeng L, Million L et al (2015) Low-dose total skin electron beam therapy as an effective modality to reduce disease burden in patients with mycosis fungoides: results of a pooled analysis from 3 phase-II clinical trials. J Am Acad Dermatol 72:286–292. https://doi.org/10.1016/j.jaad.2014.10.014 CrossRefPubMed Hoppe RT, Harrison C, Tavallaee M, Bashey S, Sundram U, Shufeng L, Million L et al (2015) Low-dose total skin electron beam therapy as an effective modality to reduce disease burden in patients with mycosis fungoides: results of a pooled analysis from 3 phase-II clinical trials. J Am Acad Dermatol 72:286–292. https://​doi.​org/​10.​1016/​j.​jaad.​2014.​10.​014 CrossRefPubMed
20.
Zurück zum Zitat Van Der Merwe DG (1993) Total skin electron therapy: a technique which can be implemented on a conventional electron linear accelerator. Int J Radiat Oncol Biol Phys 27:391–396CrossRef Van Der Merwe DG (1993) Total skin electron therapy: a technique which can be implemented on a conventional electron linear accelerator. Int J Radiat Oncol Biol Phys 27:391–396CrossRef
21.
Zurück zum Zitat Kumar PP, Henschke UK, Nibhanupudy JR (1977) Problems and solutions in achieving uniform dose distribution in superficial total body electron therapy. J Natl Med Assoc 69:645–647PubMedPubMedCentral Kumar PP, Henschke UK, Nibhanupudy JR (1977) Problems and solutions in achieving uniform dose distribution in superficial total body electron therapy. J Natl Med Assoc 69:645–647PubMedPubMedCentral
Metadaten
Titel
Dose optimization of total or partial skin electron irradiation by thermoluminescent dosimetry
verfasst von
Lars Schüttrumpf
Klement Neumaier
Cornelius Maihoefer
Maximilian Niyazi
Ute Ganswindt
Minglun Li
Peter Lang
Michael Reiner
Claus Belka
Dr. med. Stefanie Corradini
Publikationsdatum
19.01.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
Strahlentherapie und Onkologie / Ausgabe 5/2018
Print ISSN: 0179-7158
Elektronische ISSN: 1439-099X
DOI
https://doi.org/10.1007/s00066-018-1263-9

Weitere Artikel der Ausgabe 5/2018

Strahlentherapie und Onkologie 5/2018 Zur Ausgabe

Update Onkologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.