22.01.2018 | Original Article

Effect of a calcium chloride solution treatment on physical and mechanical properties of glass ionomer cements

verfasst von: Dimitrios Dionysopoulos, Kosmas Tolidis, Dimitrios Tortopidis, Paris Gerasimou, Thrasyvoulos Sfeikos

Erschienen in: Odontology | Ausgabe 4/2018

Einloggen, um Zugang zu erhalten

Abstract

This paper details a novel method to improve wear resistance of dental glass ionomer cement (GIC) restorations. The purpose of this in vitro study was to evaluate the effect of a calcium chloride (CaCl2) solution treatment on surface hardness, surface roughness, compressive strength, water sorption and solubility of three conventional glass ionomer cements (GICs). Additionally, the changes of the Ca composition and morphology of the surface of the tested GICs were also investigated. The experimental groups of the study were: Group 1 (control) specimens after mixing were left in the mold to set without any treatment for 5 min; Group 2 specimens were left in the mold to set for 5 min and then each specimen was immersed in 10 ml of 42.7 wt% CaCl2 solution for 60 s. Statistical analysis was performed using one-way ANOVA and Tukey post hoc tests (a = 0.05). Calcium chloride solution treatment increased surface hardness of the GICs compared to control groups (P < 0.05), while surface roughness and compressive strength did not change after the treatment (P > 0.05). Reduction in water sorption and solubility was detected but not in all CaCl2 solution-treatment groups. No alterations were observed in surface morphology of the GICs, while surface calcium composition was increased after the treatment (P < 0.05). The use of a CaCl2 solution immediately after initial setting of GICs may be advantageous for some properties of the materials and possibly leads to improved prognosis and wear resistance of their restorations.
Literatur
1.
Zurück zum Zitat Dionysopoulos D, Koliniotou-Koumpia E, Helvatzoglou-Antoniades M, Kotsanos N. Fluoride release and recharge ability of contemporary fluoride-containing restorative materials and dental adhesives. Dent Mater J. 2013;32:296–304.CrossRef Dionysopoulos D, Koliniotou-Koumpia E, Helvatzoglou-Antoniades M, Kotsanos N. Fluoride release and recharge ability of contemporary fluoride-containing restorative materials and dental adhesives. Dent Mater J. 2013;32:296–304.CrossRef
2.
Zurück zum Zitat Tamilselvam S, Divyanand MJ, Neelakantan P. Biocompatibility of a conventional glass ionomer, ceramic reinforced glass ionomer, giomer and resin composite to fibroblasts: in vitro study. J Clin Pediatr Dent. 2013;37:403–6.CrossRef Tamilselvam S, Divyanand MJ, Neelakantan P. Biocompatibility of a conventional glass ionomer, ceramic reinforced glass ionomer, giomer and resin composite to fibroblasts: in vitro study. J Clin Pediatr Dent. 2013;37:403–6.CrossRef
3.
Zurück zum Zitat Nicholson JW. Adhesion of glass ionomer cements to teeth: a review. Int J Adhes Adhes. 2016;69:33–8.CrossRef Nicholson JW. Adhesion of glass ionomer cements to teeth: a review. Int J Adhes Adhes. 2016;69:33–8.CrossRef
4.
Zurück zum Zitat Yan Z, Sidhu SK, Carrick TE, McCabe JF. Response to thermal stimuli of glass ionomer cements. Dent Mater. 2007;23:597–600.CrossRef Yan Z, Sidhu SK, Carrick TE, McCabe JF. Response to thermal stimuli of glass ionomer cements. Dent Mater. 2007;23:597–600.CrossRef
5.
Zurück zum Zitat Gu S, Rasimick BJ, Deutsch AS, Musikant BL. In vitro evaluation of five core materials. J Prosthodont. 2007;16:25–30.CrossRef Gu S, Rasimick BJ, Deutsch AS, Musikant BL. In vitro evaluation of five core materials. J Prosthodont. 2007;16:25–30.CrossRef
6.
Zurück zum Zitat Kleverlaan CJ, van Duinen RNB, Feilzer AJ. Mechanical properties of glass ionomer cements affected by curing methods. Dent Mater. 2004;20:45–50.CrossRef Kleverlaan CJ, van Duinen RNB, Feilzer AJ. Mechanical properties of glass ionomer cements affected by curing methods. Dent Mater. 2004;20:45–50.CrossRef
7.
Zurück zum Zitat de Gee AJ, van Duinen RN, Werner A, Davidson CL. Early and long-term wear of conventional and resin-modified glass ionomers. J Dent Res. 1996;75:1613–9.CrossRef de Gee AJ, van Duinen RN, Werner A, Davidson CL. Early and long-term wear of conventional and resin-modified glass ionomers. J Dent Res. 1996;75:1613–9.CrossRef
8.
Zurück zum Zitat Ilie N, Hickel R, Valceanu AS, Huth KC. Fracture toughness of dental restorative materials. Clin Oral Investig. 2012;16:489–98.CrossRef Ilie N, Hickel R, Valceanu AS, Huth KC. Fracture toughness of dental restorative materials. Clin Oral Investig. 2012;16:489–98.CrossRef
9.
Zurück zum Zitat Peutzfeldt A, García-Godoy F, Asmussen E. Surface hardness and wear of glass ionomers and compomers. Am J Dent. 1997;10:15–7.PubMed Peutzfeldt A, García-Godoy F, Asmussen E. Surface hardness and wear of glass ionomers and compomers. Am J Dent. 1997;10:15–7.PubMed
10.
Zurück zum Zitat Bonifácio CC, Kleverlaan CJ, Raggio DP, Werner A, de Carvalho RC, van Amerongen WE. Physical-mechanical properties of glass ionomer cements indicated for atraumatic restorative treatment. Aust Dent J. 2009;54:233–7.CrossRef Bonifácio CC, Kleverlaan CJ, Raggio DP, Werner A, de Carvalho RC, van Amerongen WE. Physical-mechanical properties of glass ionomer cements indicated for atraumatic restorative treatment. Aust Dent J. 2009;54:233–7.CrossRef
11.
Zurück zum Zitat Silva RM, Santos PHN, Souza LB, Dumont VC, Soares JA, Santos MH. Effects of cellulose fibers on the physical and chemical properties of glass ionomer dental restorative materials. Mater Res Bull. 2013;48:118–26.CrossRef Silva RM, Santos PHN, Souza LB, Dumont VC, Soares JA, Santos MH. Effects of cellulose fibers on the physical and chemical properties of glass ionomer dental restorative materials. Mater Res Bull. 2013;48:118–26.CrossRef
12.
Zurück zum Zitat Najeeb S, Khurshid Z, Zafar MS, Khan AS, Zohaib S, Marti JMN, et al. Modifications in glass ionomer cements: nano-sized fillers and bioactive nanoceramics. Int J Mol Sci. 2016;17:1134.CrossRef Najeeb S, Khurshid Z, Zafar MS, Khan AS, Zohaib S, Marti JMN, et al. Modifications in glass ionomer cements: nano-sized fillers and bioactive nanoceramics. Int J Mol Sci. 2016;17:1134.CrossRef
13.
Zurück zum Zitat Tolidis K, Dionysopoulos D, Gerasimou P, Sfeikos T. Effect of radiant heat and ultrasound on fluoride release and surface hardness of glass ionomer cements. J Appl Biomater Funct Mater. 2016;14:e463–9.PubMed Tolidis K, Dionysopoulos D, Gerasimou P, Sfeikos T. Effect of radiant heat and ultrasound on fluoride release and surface hardness of glass ionomer cements. J Appl Biomater Funct Mater. 2016;14:e463–9.PubMed
14.
Zurück zum Zitat Gavic L, Gorseta K, Glavina D, Czarnecka B, Nicholson JW. Heat transfer properties and thermal cure of glass-ionomer dental cements. J Mater Sci Mater Med. 2015;26:249.CrossRef Gavic L, Gorseta K, Glavina D, Czarnecka B, Nicholson JW. Heat transfer properties and thermal cure of glass-ionomer dental cements. J Mater Sci Mater Med. 2015;26:249.CrossRef
15.
Zurück zum Zitat Menne-Happ U, Ilie N. Effect of heat application on the mechanical behaviour of glass ionomer cements. Clin Oral Investig. 2014;18:643–50.CrossRef Menne-Happ U, Ilie N. Effect of heat application on the mechanical behaviour of glass ionomer cements. Clin Oral Investig. 2014;18:643–50.CrossRef
16.
Zurück zum Zitat Dionysopoulos D, Tolidis K, Strakas D, Gerasimou P, Sfeikos T, Gutknecht N. Effect of radiant heat on conventional glass ionomer cements during setting by using a blue light diode laser system (445 nm). Lasers Med Sci. 2017;32:703–9.CrossRef Dionysopoulos D, Tolidis K, Strakas D, Gerasimou P, Sfeikos T, Gutknecht N. Effect of radiant heat on conventional glass ionomer cements during setting by using a blue light diode laser system (445 nm). Lasers Med Sci. 2017;32:703–9.CrossRef
17.
Zurück zum Zitat Dehurtevent M, Deveaux E, Hornez JC, Robberecht L, Tabary N, Chai F. Influence of heat and ultrasonic treatments on the setting and maturation of a glass-ionomer cement. Am J Dent. 2015;28:105–10.PubMed Dehurtevent M, Deveaux E, Hornez JC, Robberecht L, Tabary N, Chai F. Influence of heat and ultrasonic treatments on the setting and maturation of a glass-ionomer cement. Am J Dent. 2015;28:105–10.PubMed
18.
Zurück zum Zitat Towler MR, Bushby AJ, Billington RW, Hill RG. A preliminary comparison of the mechanical properties of chemically cured and ultrasonically cured glass ionomer cements, using nano-indentation techniques. Biomaterials. 2001;22:1401–6.CrossRef Towler MR, Bushby AJ, Billington RW, Hill RG. A preliminary comparison of the mechanical properties of chemically cured and ultrasonically cured glass ionomer cements, using nano-indentation techniques. Biomaterials. 2001;22:1401–6.CrossRef
19.
Zurück zum Zitat Shiozawa M, Takahashi H, Iwasaki N, Wada T, Uo M. Effect of immersion time of restorative glass ionomer cements and immersion duration in calcium chloride solution on surface hardness. Dent Mater. 2014;30:e377–83.CrossRef Shiozawa M, Takahashi H, Iwasaki N, Wada T, Uo M. Effect of immersion time of restorative glass ionomer cements and immersion duration in calcium chloride solution on surface hardness. Dent Mater. 2014;30:e377–83.CrossRef
20.
Zurück zum Zitat Shiozawa M, Takahashi H, Iwasaki N, Uo M. Effect of calcium chloride solution immersion on surface hardness of restorative glass ionomer cements. Dent Mater J. 2013;32:828–33.CrossRef Shiozawa M, Takahashi H, Iwasaki N, Uo M. Effect of calcium chloride solution immersion on surface hardness of restorative glass ionomer cements. Dent Mater J. 2013;32:828–33.CrossRef
21.
Zurück zum Zitat Dionysopoulos D, Tolidis K, Gerasimou P, Sfeikos T. Effect of three clinical curing treatments on fluoride release and surface hardness of glass ionomer cements. Int J Periodontics Restor Dent. 2017;37:e197–203.CrossRef Dionysopoulos D, Tolidis K, Gerasimou P, Sfeikos T. Effect of three clinical curing treatments on fluoride release and surface hardness of glass ionomer cements. Int J Periodontics Restor Dent. 2017;37:e197–203.CrossRef
22.
Zurück zum Zitat Musanje L, Shu M, Darvell B. Water sorption and mechanical behaviour of cosmetic direct restorative materials in artificial saliva. Dent Mater. 2001;17:394–401.CrossRef Musanje L, Shu M, Darvell B. Water sorption and mechanical behaviour of cosmetic direct restorative materials in artificial saliva. Dent Mater. 2001;17:394–401.CrossRef
23.
Zurück zum Zitat Leach R. In: Characterisation of areal surface texture. Chapter: The areal field parameters. Springer, p. 15–43. Leach R. In: Characterisation of areal surface texture. Chapter: The areal field parameters. Springer, p. 15–43.
24.
Zurück zum Zitat Dionysopoulos D, Tolidis K, Sfeikos T, Karanasiou C, Parisi X. Evaluation of surface microhardness and abrasion resistance of two dental glass ionomer cements after radiant heat treatment. Adv Mater Sci Eng 2017 Article ID: 5824562. Dionysopoulos D, Tolidis K, Sfeikos T, Karanasiou C, Parisi X. Evaluation of surface microhardness and abrasion resistance of two dental glass ionomer cements after radiant heat treatment. Adv Mater Sci Eng 2017 Article ID: 5824562.
25.
Zurück zum Zitat Heintze SD, Zellweger G, Zappini G. The relationship between physical parameters and wear of dental composites. Wear. 2007;263:1138–46.CrossRef Heintze SD, Zellweger G, Zappini G. The relationship between physical parameters and wear of dental composites. Wear. 2007;263:1138–46.CrossRef
26.
Zurück zum Zitat Nicholson JW, McKenzie MA, Goodridge R, Wilson AD. Variations in the compressive strength of dental cements stored in ionic or acidic solutions. J Mater Sci Mater Med. 2001;12:647–52.CrossRef Nicholson JW, McKenzie MA, Goodridge R, Wilson AD. Variations in the compressive strength of dental cements stored in ionic or acidic solutions. J Mater Sci Mater Med. 2001;12:647–52.CrossRef
27.
Zurück zum Zitat Nicholson JW. Studies in the setting of polyelectrolyte cements: part VII. The effect of divalent metal chlorides on the properties of zinc polycarboxylate and glass-ionomer dental cements. J Mater Sci Mater Med. 1998;9:273–7.CrossRef Nicholson JW. Studies in the setting of polyelectrolyte cements: part VII. The effect of divalent metal chlorides on the properties of zinc polycarboxylate and glass-ionomer dental cements. J Mater Sci Mater Med. 1998;9:273–7.CrossRef
28.
Zurück zum Zitat Nicholson JW, Wilson AD. The effect of storage in aqueous solutions on glass-ionomer and zinc polycarboxylate dental cements. J Mater Sci Mater Med. 2000;11:357–60.CrossRef Nicholson JW, Wilson AD. The effect of storage in aqueous solutions on glass-ionomer and zinc polycarboxylate dental cements. J Mater Sci Mater Med. 2000;11:357–60.CrossRef
29.
Zurück zum Zitat Zankuli MA, Delvin H, Silikas N. Water sorption and solubility of core built-up materials. Dent Mater. 2014;30:e324–9.CrossRef Zankuli MA, Delvin H, Silikas N. Water sorption and solubility of core built-up materials. Dent Mater. 2014;30:e324–9.CrossRef
30.
Zurück zum Zitat Martin N, Jedynakiewicz N. Measurement of water sorption in dental composites. Biomaterials. 1998;19:77–83.CrossRef Martin N, Jedynakiewicz N. Measurement of water sorption in dental composites. Biomaterials. 1998;19:77–83.CrossRef
31.
Zurück zum Zitat Calvo AFB, Kicuti A, Tedesco TK, Braga MM, Raggio DP. Evaluation of the relationship between the cost and properties of glass ionomer cements indicated for atraumatic restorative treatment. Braz Oral Res. 2016;30:e8. Calvo AFB, Kicuti A, Tedesco TK, Braga MM, Raggio DP. Evaluation of the relationship between the cost and properties of glass ionomer cements indicated for atraumatic restorative treatment. Braz Oral Res. 2016;30:e8.
32.
Zurück zum Zitat Nicholson JW, Czarnecka B. Kinetic studies of water uptake and loss in glass-ionomer cements. J Mater Sci Mater Med. 2008;19:1723–7.CrossRef Nicholson JW, Czarnecka B. Kinetic studies of water uptake and loss in glass-ionomer cements. J Mater Sci Mater Med. 2008;19:1723–7.CrossRef
33.
Zurück zum Zitat Dowling AH, Fleming GJP, McGinley L, Addison O. Improving the standard of the standard for glass ionomers: an alternative to the compressive fracture strength test for consideration? J Dent. 2012;40:189–201.CrossRef Dowling AH, Fleming GJP, McGinley L, Addison O. Improving the standard of the standard for glass ionomers: an alternative to the compressive fracture strength test for consideration? J Dent. 2012;40:189–201.CrossRef
34.
Zurück zum Zitat Chai J, Takahashi Y, Hisama K, Shimizu H. Water sorption and dimensional stability of three glass fiber-reinforced composites. Int J Prosthodont. 2004;17:195–9.PubMed Chai J, Takahashi Y, Hisama K, Shimizu H. Water sorption and dimensional stability of three glass fiber-reinforced composites. Int J Prosthodont. 2004;17:195–9.PubMed
Metadaten
Titel
Effect of a calcium chloride solution treatment on physical and mechanical properties of glass ionomer cements
verfasst von
Dimitrios Dionysopoulos
Kosmas Tolidis
Dimitrios Tortopidis
Paris Gerasimou
Thrasyvoulos Sfeikos
Publikationsdatum
22.01.2018
Verlag
Springer Japan
Erschienen in
Odontology / Ausgabe 4/2018
Print ISSN: 1618-1247
Elektronische ISSN: 1618-1255
DOI
https://doi.org/10.1007/s10266-018-0338-5

Weitere Artikel der Ausgabe 4/2018

Odontology 4/2018 Zur Ausgabe

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Parodontalbehandlung verbessert Prognose bei Katheterablation

19.04.2024 Vorhofflimmern Nachrichten

Werden Personen mit Vorhofflimmern in der Blanking-Periode nach einer Katheterablation gegen eine bestehende Parodontitis behandelt, verbessert dies die Erfolgsaussichten. Dafür sprechen die Resultate einer prospektiven Untersuchung.

Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.