Skip to main content
Erschienen in: General Thoracic and Cardiovascular Surgery 4/2017

10.02.2016 | Case Report

Endovascular treatment of large and wide aortic neck: case report and literature review

verfasst von: Felice Pecoraro, David Pakeliani, Ettore Dinoto, Guido Bajardi

Erschienen in: General Thoracic and Cardiovascular Surgery | Ausgabe 4/2017

Einloggen, um Zugang zu erhalten

Abstract

Large (24–34 mm) and wide (≥35 mm) aortic necks are a contraindication to endovascular aneurysm repair (EVAR). A 63-year-old man, unfit for conventional surgery, presented a 79 mm abdominal aortic aneurysm with 36.5 mm aortic neck and a 62 mm right common iliac artery aneurysm. He was treated endovascularly with standard commercially available stent-graft using the so-called ‘funnel technique’; by placing a thoracic stent-graft inside a bifurcated device to achieve proximal sealing. The completion angiography and the 6 months follow-up with computed tomography showed no stent-graft migration, limb occlusion or endoleak. The literature review reported 179 cases of large aortic neck managed with EVAR, all cases treated with standard devices. Conversely a wide aortic neck was reported in 9; in 2 cases were employed custom-made devices and in 7 standard stent-graft. The use of EVAR with commercially available stent-grafts is feasible and it represents an option especially in non-elective setting.
Literatur
1.
Zurück zum Zitat Paravastu SC, Jayarajasingam R, Cottam R, Palfreyman SJ, Michaels JA, Thomas SM. Endovascular repair of abdominal aortic aneurysm. Cochrane Database Syst Rev. 2014;1:CD004178. doi:10.1002/14651858.CD004178.pub2. Paravastu SC, Jayarajasingam R, Cottam R, Palfreyman SJ, Michaels JA, Thomas SM. Endovascular repair of abdominal aortic aneurysm. Cochrane Database Syst Rev. 2014;1:CD004178. doi:10.​1002/​14651858.​CD004178.​pub2.
3.
Zurück zum Zitat Brossier J, Coscas R, Capdevila C, Kitzis M, Coggia M, Goeau-Brissonniere O. Anatomic feasibility of endovascular treatment of abdominal aortic aneurysms in emergency in the era of the chimney technique: impact on an emergency endovascular kit. Ann Vasc Surg. 2013;27(7):844–50. doi:10.1016/j.avsg.2012.05.035.CrossRefPubMed Brossier J, Coscas R, Capdevila C, Kitzis M, Coggia M, Goeau-Brissonniere O. Anatomic feasibility of endovascular treatment of abdominal aortic aneurysms in emergency in the era of the chimney technique: impact on an emergency endovascular kit. Ann Vasc Surg. 2013;27(7):844–50. doi:10.​1016/​j.​avsg.​2012.​05.​035.CrossRefPubMed
4.
Zurück zum Zitat Zayed HA, Bell RE, Clough RE, Thomas S, Sabharwal T, Reidy JF, et al. Results of endovascular repair of abdominal aortic aneurysms with an unfavorable proximal neck using large stent-grafts. Cardiovasc Intervent Radiol. 2009;32(6):1161–4. doi:10.1007/s00270-009-9557-z.CrossRefPubMed Zayed HA, Bell RE, Clough RE, Thomas S, Sabharwal T, Reidy JF, et al. Results of endovascular repair of abdominal aortic aneurysms with an unfavorable proximal neck using large stent-grafts. Cardiovasc Intervent Radiol. 2009;32(6):1161–4. doi:10.​1007/​s00270-009-9557-z.CrossRefPubMed
5.
Zurück zum Zitat Bastos Goncalves F, Hoeks SE, Teijink JA, Moll FL, Castro JA, Stolker RJ, et al. Risk factors for proximal neck complications after endovascular aneurysm repair using the endurant stentgraft. Eur J Vasc Endovasc Surg. 2015;49(2):156–62. doi:10.1016/j.ejvs.2014.10.003.CrossRefPubMed Bastos Goncalves F, Hoeks SE, Teijink JA, Moll FL, Castro JA, Stolker RJ, et al. Risk factors for proximal neck complications after endovascular aneurysm repair using the endurant stentgraft. Eur J Vasc Endovasc Surg. 2015;49(2):156–62. doi:10.​1016/​j.​ejvs.​2014.​10.​003.CrossRefPubMed
6.
Zurück zum Zitat Walker TG, Kalva SP, Yeddula K, Wicky S, Kundu S, Drescher P, et al. Clinical practice guidelines for endovascular abdominal aortic aneurysm repair: written by the Standards of Practice Committee for the Society of Interventional Radiology and endorsed by the Cardiovascular and Interventional Radiological Society of Europe and the Canadian Interventional Radiology Association. J Vasc Interv Radiol JVIR. 2010;21(11):1632–55. doi:10.1016/j.jvir.2010.07.008.CrossRefPubMed Walker TG, Kalva SP, Yeddula K, Wicky S, Kundu S, Drescher P, et al. Clinical practice guidelines for endovascular abdominal aortic aneurysm repair: written by the Standards of Practice Committee for the Society of Interventional Radiology and endorsed by the Cardiovascular and Interventional Radiological Society of Europe and the Canadian Interventional Radiology Association. J Vasc Interv Radiol JVIR. 2010;21(11):1632–55. doi:10.​1016/​j.​jvir.​2010.​07.​008.CrossRefPubMed
7.
Zurück zum Zitat Ingle H, Fishwick G, Thompson MM, Bell PR. Endovascular repair of wide neck AAA-preliminary report on feasibility and complications. Eur J Vasc Endovasc Surg. 2002;24(2):123–7.CrossRefPubMed Ingle H, Fishwick G, Thompson MM, Bell PR. Endovascular repair of wide neck AAA-preliminary report on feasibility and complications. Eur J Vasc Endovasc Surg. 2002;24(2):123–7.CrossRefPubMed
8.
Zurück zum Zitat Jordan WD Jr, Moore WM Jr, Melton JG, Brown OW, Carpenter JP, Endologix I. Secure fixation following EVAR with the Powerlink XL System in wide aortic necks: results of a prospective, multicenter trial. J Vasc Surg. 2009;50(5):979–86. doi:10.1016/j.jvs.2009.05.057.CrossRefPubMed Jordan WD Jr, Moore WM Jr, Melton JG, Brown OW, Carpenter JP, Endologix I. Secure fixation following EVAR with the Powerlink XL System in wide aortic necks: results of a prospective, multicenter trial. J Vasc Surg. 2009;50(5):979–86. doi:10.​1016/​j.​jvs.​2009.​05.​057.CrossRefPubMed
9.
Zurück zum Zitat Saha P, Hughes J, Patel AS, Donati T, Sallam M, Patel SD, et al. Medium-term outcomes following endovascular repair of infrarenal abdominal aortic aneurysms with an unfavourable proximal neck. Cardiovasc Intervent Radiol. 2014;38(4):840–5. doi:10.1007/s00270-014-1038-3.CrossRefPubMed Saha P, Hughes J, Patel AS, Donati T, Sallam M, Patel SD, et al. Medium-term outcomes following endovascular repair of infrarenal abdominal aortic aneurysms with an unfavourable proximal neck. Cardiovasc Intervent Radiol. 2014;38(4):840–5. doi:10.​1007/​s00270-014-1038-3.CrossRefPubMed
10.
Zurück zum Zitat Lee JT, Lee J, Aziz I, Donayre CE, Walot I, Kopchok GE, et al. Stent-graft migration following endovascular repair of aneurysms with large proximal necks: anatomical risk factors and long-term sequelae. J Endovasc Therapy. 2002;9(5):652–64. doi:10.1583/1545-1550(2002) 009<0652:SGMFER>2.0.CO;2. Lee JT, Lee J, Aziz I, Donayre CE, Walot I, Kopchok GE, et al. Stent-graft migration following endovascular repair of aneurysms with large proximal necks: anatomical risk factors and long-term sequelae. J Endovasc Therapy. 2002;9(5):652–64. doi:10.1583/1545-1550(2002) 009<0652:SGMFER>2.0.CO;2.
11.
Zurück zum Zitat Perdikides T, Melas N, Lagios K, Saratzis A, Siafakas A, Bountouris I, et al. Primary endoanchoring in the endovascular repair of abdominal aortic aneurysms with an unfavorable neck. J Endovasc Ther. 2012;19(6):707–15. doi:10.1583/JEVT-12-4008R.1.CrossRefPubMed Perdikides T, Melas N, Lagios K, Saratzis A, Siafakas A, Bountouris I, et al. Primary endoanchoring in the endovascular repair of abdominal aortic aneurysms with an unfavorable neck. J Endovasc Ther. 2012;19(6):707–15. doi:10.​1583/​JEVT-12-4008R.​1.CrossRefPubMed
14.
Zurück zum Zitat Rancic Z, Pecoraro F, Pfammatter T, Banzic I, Klein H, Kyriakidis K, et al. The use of Endurant stent-graft for abdominal aortic aneurysm: the story about extension of instruction for use with persistent good results of stent-graft latest generation. J Cardiovasc Surg. 2012;53(5):579–94. Rancic Z, Pecoraro F, Pfammatter T, Banzic I, Klein H, Kyriakidis K, et al. The use of Endurant stent-graft for abdominal aortic aneurysm: the story about extension of instruction for use with persistent good results of stent-graft latest generation. J Cardiovasc Surg. 2012;53(5):579–94.
Metadaten
Titel
Endovascular treatment of large and wide aortic neck: case report and literature review
verfasst von
Felice Pecoraro
David Pakeliani
Ettore Dinoto
Guido Bajardi
Publikationsdatum
10.02.2016
Verlag
Springer Japan
Erschienen in
General Thoracic and Cardiovascular Surgery / Ausgabe 4/2017
Print ISSN: 1863-6705
Elektronische ISSN: 1863-6713
DOI
https://doi.org/10.1007/s11748-016-0627-2

Weitere Artikel der Ausgabe 4/2017

General Thoracic and Cardiovascular Surgery 4/2017 Zur Ausgabe

Wie erfolgreich ist eine Re-Ablation nach Rezidiv?

23.04.2024 Ablationstherapie Nachrichten

Nach der Katheterablation von Vorhofflimmern kommt es bei etwa einem Drittel der Patienten zu Rezidiven, meist binnen eines Jahres. Wie sich spätere Rückfälle auf die Erfolgschancen einer erneuten Ablation auswirken, haben Schweizer Kardiologen erforscht.

Hinter dieser Appendizitis steckte ein Erreger

23.04.2024 Appendizitis Nachrichten

Schmerzen im Unterbauch, aber sonst nicht viel, was auf eine Appendizitis hindeutete: Ein junger Mann hatte Glück, dass trotzdem eine Laparoskopie mit Appendektomie durchgeführt und der Wurmfortsatz histologisch untersucht wurde.

Mehr Schaden als Nutzen durch präoperatives Aussetzen von GLP-1-Agonisten?

23.04.2024 Operationsvorbereitung Nachrichten

Derzeit wird empfohlen, eine Therapie mit GLP-1-Rezeptoragonisten präoperativ zu unterbrechen. Eine neue Studie nährt jedoch Zweifel an der Notwendigkeit der Maßnahme.

Ureterstriktur: Innovative OP-Technik bewährt sich

19.04.2024 EAU 2024 Kongressbericht

Die Ureterstriktur ist eine relativ seltene Komplikation, trotzdem bedarf sie einer differenzierten Versorgung. In komplexen Fällen wird dies durch die roboterassistierte OP-Technik gewährleistet. Erste Resultate ermutigen.

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.