Extended Multimodal Flat Detector CT Imaging in Acute Ischemic Stroke: A Pilot Study

verfasst von: Philip Hoelter, Stefan Lang, Vanessa Beuscher, Bernd Kallmuenzer, Michael Manhart, Stefan Schwab, Arnd Doerfler

Erschienen in: Journal of Imaging Informatics in Medicine | Ausgabe 3/2023

Abstract

By using Flat detector computed tomography (FD-CT), a one-stop-shop approach in the diagnostic workup of acute ischemic stroke (AIS) might be achieved. Although information on upstream vessels is warranted, dedicated FD-CT protocols which include the imaging of the cervical vasculature are still lacking. We aimed to prospectively evaluate the implementation of a new multimodal FD-CT protocol including cervical vessel imaging in AIS patients. In total, 16 patients were included in this study. Eight patients with AIS due to large vessel occlusion (LVO) prospectively received a fully multimodal FD-CT imaging, including non-enhanced flat detector computed tomography (NE-FDCT), dynamic perfusion flat detector computed tomography (FD-CTP) and flat detector computed tomography angiography (FD-CTA) including cervical imaging. For comparison of time metrics and image quality, eight AIS patients, which received multimodal CT imaging, were included retrospectively. Although image quality of NE-FDCT and FD-CTA was rated slightly lower than NE-CT and CTA, all FD-CT datasets were of diagnostic quality. Intracerebral hemorrhage exclusion and LVO detection was reliably possible. Median door-to-image time was comparable for the FD-CT group and the control group (CT:30 min, IQR27-58; FD-CT:44.5 min, IQR31-55, p = 0.491). Door-to-groin-puncture time (CT:79.5 min, IQR65-90; FD-CT:59.5 min, IQR51-67; p = 0.016) and image-to-groin-puncture time (CT:44 min, IQR30-50; FD-CT:14 min, IQR12-18; p < 0.001) were significantly shorter, when patients were directly transferred to the angiosuite, where FD-CT took place. Our study indicates that using a new fully multimodal FD-CT approach including imaging of cervical vessels for first-line imaging in AIS patients is feasible and comparable to multimodal CT imaging with substantial potential to streamline the stroke workflow.
Hinweise

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Introduction

Expeditious endovascular treatment (EVT) is the therapy of choice in patients with acute ischemic stroke (AIS) due to large vessel occlusion (LVO) of the anterior circulation [14]. Even patients in an extended time window up to 24 h after symptom onset, could benefit from EVT [5]. However, time remains crucial, as it has been shown that the door-to-puncture time and the imaging-to-puncture time, respectively, are independent predictors of successful recanalization and subsequent better outcome [6, 7]. Continuous time surveillance and frequent feedback become more important to extinguish causes of delay and to maintain and improve an effective workflow. Although time from patient arrival in the emergency room (ER) to beginning of EVT has improved from two hours to one hour, transfer remains a crucial bottleneck within a fast AIS workflow [7, 8].
The idea to perform diagnostic and therapeutic imaging within the angiosuite is obvious, as a prolonged time interval from brain imaging to reperfusion negatively effects the outcome [9].
However, the majority of hospitals is not capable to perform EVT and the patients are transferred to an endovascular capable center (ECC) [10]. Due to deterioration and prolonged transportation times, a second multimodal computed tomography (CT) at the ECC might be necessary to decide whether EVT is still indicated. To save time at the ECC, the implementation of a “one stop” approach in the workup of ischemic stroke within the angiosuite is aspired. Studies on “one-stop” management have already been published [1113]. These studies used flat detector computed tomography (FD-CT), a broadly used imaging technology in interventional radiology and neuroradiology, that offers images with high spatial resolution [14]. However, none of these trials reported on a fully multimodal flat detector computed tomography (FD-CT) approach, that is capable of a dedicated angiographic imaging of the cervical vasculature. Hence, the suggested FD-CT workflow protocols lack of visualization of the cervical vasculature. Thus, important information for EVT planning, e.g., tortuous anatomy, upstream stenosis or dissection, may be missed initially, although extracranial stenosis of the internal cervical artery (ICA) is an important cause of LVO, causing up to 16% of AIS [15].
The purpose of our study was to analyze if fully multimodal FD-CT as an imaging approach is (i) feasible and (ii) expedites the current workflow for outpatients with AIS, when compared to conventional multimodal CT.

Materials and Methods

Study Population

Informed consent was obtained by the patients or legal representatives according to local law and regulations. Institutional review board approval was obtained before the commencement of this study and this study was performed in accordance with the ethical standards laid down in the 1964 Declaration of Helsinki and its later amendments.
A total of 16 patients were included. Inclusion criteria were a National Institutes of Health Stroke Scale (NIHSS) > 3, age > 18 years, AIS symptoms due to suspected LVO and transfer from non-endovascular capable centers (nECC) to receive EVT (drip and ship model). To compare time metrics without any bias due to performed general anesthesia (GA), only patients with externally performed GA were included. Moreover, to avoid exposing patients to unnecessary radiation, only patients were included in which an externally performed imaging was not delivered, so new imaging before EVT was required for treatment decision (hemorrhage exclusion, LVO detection, situation of brain hemodynamics).
Our patient collective consisted of two parts. First, we screened prospectively for patients eligible for multimodal FD-CT. Out of 163 AIS patients that received EVT due to LVO between January 2020 and October 2020 (10 months), eight patients met the inclusion criteria and were transferred to the angiosuite, where multimodal FD-CT imaging was performed before EVT due to clinical indication.
Second, we screened our database for AIS patients that received EVT in our department and received multimodal CT imaging before transfer to the angiosuite. Between August 2017 and January 2019 (15 months), 261 patients with LVO received EVT in our department. During that period eight patients, that were screened retrospectively, met the inclusion criteria.
For all patients major workflow times were recorded: Time of AIS onset; Time of arrival in the ER of our center; Time of cerebral imaging; Time of groin puncture; Time of last DSA series. From the recorded data, several time intervals were calculated: Symptom onset to initial imaging (onset-to-image); ER arrival to initial imaging (door-to-image); ER arrival to groin puncture (door-to-groin-puncture); initial imaging to groin puncture (image-to-groin-puncture); initial imaging to reperfusion (image-to-reperfusion); groin puncture to reperfusion (groin-puncture-to-reperfusion). “Groin puncture” was defined as the moment when the interventionalist cannulates the inguinal artery to gain access to the patient's arterial system, thereby beginning the EVT procedure. “Reperfusion” was defined as the end of EVT, irrespective of the achieved TICI score. Workflow is pictured in Fig. 1.

Multimodal CT

CT was performed using a 128-section scanner (Somatom Definition AS + ; Siemens Healthcare GmbH, Forchheim, Germany). A multimodal stroke protocol (non-enhanced computed tomography (NECT), CTA and computed tomography perfusion (CTP)) was performed.
CTA was performed in caudocranial direction with a coverage in the z-axis was from the aortic arch to the cranial vertex (120 kV, 160 mAs, collimation: 128 × 0.6 mm, rotation time: 0.3 s). 60 ml contrast agent (Imeron® 400, Bracco Imaging, Konstanz, Germany) were injected via an 18-gauge cubital-vein-cannula at a rate of 5 ml/s, followed by 50 ml of saline flush. Bolus tracking was performed in the ascending aorta and image acquisition started 4 s after contrast exceeding 100 HU [16].
CTP was performed in caudocranial direction. Coverage in the z-axis was 96 mm, centered in the basal ganglia (80 kV, 80 mAs). Acquisition of one scan every 1.5 s over a period of 67.98 s was initiated with a delay of 2 s after contrast injection. 30 ml contrast agent (Imeron® 400, Bracco Imaging, Konstanz, Germany) were injected via an 18-gauge cubital-vein-cannula at a rate of 5 ml/s, followed by 50 ml of saline flush.

Multimodal FD-CT

Multimodal FD-CT and digital subtraction angiography (DSA) was performed in one session using the same angiography system (Artis icono; Siemens Healthcare GmbH, Forchheim, Germany) followed by DSA. All FD-CT applications used are CE-labeled. Specific FD-CT protocols were obtained in the following order: 1. non-enhanced FD-CT (NE-FDCT); 2. FD-CT perfusion (FD-CTP); 3. FD-CT angiography (FD-CTA) (Table 1). For FD-CTA, image acquisition was started using bolus watching technique.
Table 1
Flat detector protocol parameters of the specific protocols used
 
NE-FDCT
(7 s DynaCT Sine Spin)
FD-CTP
(60 s DynaCT Head Perfusion)
FD-CTA
(4 s Dyna CT Head Care)
Angulation
220°
200°
800°
° per frame
0.4
0.8
0.8
kV
109
70
70
FOV
49
49
49
Rotations [n]
1
10
1
Duration per rotation
7 s
5 s (+ 1 s pause between the rotations)
4 s
Duration in total
7 s
60 s
4 s
Amount of contrast used
n/a
50 ml
50 ml
NE-FDCT Non-enhanced Flat Detector Computed Tomography, FDCTP FDCT perfusion, FDCTA FDCT angiography
All contrast agent (Imeron® 400, Bracco Imaging, Konstanz, Germany) used was injected via an 18-gauge cubital-vein-cannula at a rate of 5 ml/s, followed by 50 ml of saline flush.
Perfusion volumes were calculated using RAPID CTP and RAPID ANGIO software (iSchema View, Inc., Menlo Park, Ca, USA). Moreover, image reconstruction was performed on a dedicated Siemens workstation and color-coded maps were generated using a dedicated prototype software (Siemens Healthcare GmbH, Forchheim, Germany).

Image Quality

All non-enhanced, angiographic and perfusion datasets were evaluated by 2 neuroradiologists (7 and 9 years of experience) with respect to image quality. The quality of the datasets was assessed in a consensus reading by using a five-point scaled grading system: 4 = excellent (high contrast, no artefacts); 3 = good (high contrast; minimal artefacts, e.g., due to movement or metallic implants); 2 = compromised (e.g., reduced homogeneity of contrast); 1 = heavily compromised (low contrast); 0 = not diagnostic (no diagnostic information).
Vascular segments were screened with regard to LVO detection: internal cervical artery (ICA) left/right with the proximal and distal segments, middle cerebral artery (MCA) left/right (proximal M1, distal M1, M2-M3), anterior cerebral artery (ACA) left/right, vertebral artery (VA) left/right (V1-V3, V4), basilar artery (BA), posterior cerebral artery (PCA) left/right. Vessel occlusion was described using a 2-point scale for FD-CTA, CTA and subsequent DSA. FD-CTA and CTA datasets were evaluated separately and in random order, blinded to clinical data. DSA datasets were evaluated in a consensus reading.

Data Analysis

Normal distribution of all data was assessed using Kolmogorov–Smirnov test. Normally distributed data were analyzed using one-way ANOVA. In absence of a normal distribution, Mann–Whitney-U test was performed. For binary data, we applied a one-tailed Fisher Exact probability test. For correlation between occlusion site as rated on FD-CTA, CTA and DSA respectively, Pearson rank correlation coefficient was applied.
Statistical significance was considered for a p-value of less than 0.05.
To assess the interrater agreement of LVO detection, the interrater correlation coefficient (ICC) was used. ICC estimates and their 95% confident intervals (CI) were based on a single rater, absolute-agreement, two-way mixed-effects model [17]. Interpretation of average ICC values was as follows: poor ≤ 0.40; fair = 0.40–0.59; good = 0.60–0.74; and excellent = 0.75–1.00.
All statistical analyses were performed using commercially available software (IBM® SPSS® Statistics Version 19, Chicago, IL, USA).

Results

Demographic and Clinical Data

The included 16 patients did not differ significantly with regard to their demographic data. The admission status was not significantly different. Most of the patients received i.v. t-PA. Left-sided stroke occurred more often within the FD-CT group, although not with significant difference (p = 0.055). The number of performed EVT-passes did not differ significantly.
Processing of perfusion parameters was feasible in all datasets. There was no significant difference between both patient groups with regard to infarct core (p = 0.161), tissue at risk (p = 0.249) or mismatch volume (p = 0.673). Moreover, both groups did not differ in terms of collateral status obtained by perfusion imaging (p = 0.893) (Table 2).
Table 2
Baseline characteristics; there was no significant difference between the patient groups, indicating a rather homogenous patient collective
 
Multimodal CT
(n = 8)
Multimodal FDCT (n = 8)
p Value
Demographic data
   
   Gendera, female
4 (50)
2 (25)
0.304
   Ageb, years
65.6 ± 10.1
68.8 ± 8.0
0.503
Admission status
   
   Pre-mRSc
0 (0–0)
0 (0–2)
0.505
   NIHSSc
17.5 (12–34)
12.5 (8–16)
0.058
   Left hemispheric strokea
3 (37.5)
4 (50)
0.055
   Anterior circulation strokea
3 (37.5%)
7 (87.5%)
0.059
   Received i.v. lysisa
8 (100)
5 (62.5)
0.1
   EVT-passes performeda
2.5 (1–3)
3 (2–3)
0.382
Perfusion Details as calculated by RAPID CTP/RAPID ANGIO
   CBFb
9.88 ± 14.29
38 ± 45.58
0.161
   Tmaxb
89.75 ± 53.40
133.88 ± 88.96
0.249
   Mismatch Volumeb
79.88 ± 44.34
95.88 ± 95.02
0.673
   HIRb
0.47 ± 0.29
0.45 ± 0.31
0.893
mRS, Modified Rankin Scale, NIHSS National Institutes of Health Stroke Scale, I.v Intravenous
an (%)
bmean ± SD
cmedian (IQR 25th-75th percentile)

Image Quality and LVO Detection

Image quality was sufficient to detect LVO in all cases and showed no significant difference between the FD-CT and the CT group (p = 0.721). Perfusion datasets were sufficient for further analysis too, regardless of the imaging modality (p = 0.645). Image quality was lower for NE-FDCT (p < 0.001) and FD-CTA datasets (p = 0.001) compared to NECT and CTA data (Table 3). However, all NE-FDCT and FD-CTA datasets were of diagnostic quality.
Table 3
Quality metrics; image quality of the non-enhanced CT was significantly superior compared to FDCT imaging, whereas there was no significant difference in image quality regarding the perfusion imaging. Although CT-angiography yielded a significant superior image quality, it did not result into a superior LVO-detection
 
Multimodal CT
(n = 8)
Multimodal FDCT (n = 8)
p Value
Image Qualitya
   
Non-enhanced
4 (4–4)
2.5 (2–3)
 < 0.001
Perfusion data
4 (3–4)
4 (3–4)
0.645
Angiographic data
4 (4–4)
3 (3–4)
0.01
LVO-detection
4 (4–4)
4 (4–4)
0.721
amedian (IQR 25th-75th percentile)
A total of 304 vessel segments (152 by FD-CTA, 152 by CTA) were scored to define site of LVO. Detailed occlusion sites are listed in Table 4. Correlation between DSA series and rated FD-CTA, CTA, respectively, was excellent for both readers (Reader 1: r = 0.967, p < 0.001; Reader 2: r = 0.969, p < 0.001). Interrater agreement was excellent for both FD-CTA (ICC = 0.986 (0.929–0.997)) and CTA assessment (ICC = 0.995 (0.976–0.999)).
Table 4
Occlusion sites; detailed site of each vessel occlusion as detected by FD-CT and CT was assessed for Reader 1 and 2 separately. Site of occlusion assessed on the DSA images in consensus was considered gold standard
 
Reader 1
Reader 2
 
Vascular segment, n (%)
FD-CT (n = 8)
CT (n = 8)
FD-CT (n = 8)
CT (n = 8)
DSA (n = 16)
Proximal ICA
1 (12.5)
0
1 (12.5)
0
1 (6.3)
Distal ICA
0
1 (12.5)
1 (12.5)
1 (12.5)
2 (12.5)
Proximal M1
4 (50)
1 (12.5)
4 (50)
1 (12.5)
5 (31.2)
Distal M1
1 (12.5)
0
0
0
0
M2/3
1 (12.5)
1 (12.5)
1 (12.5)
1 (12.5)
2 (12.5)
ACA
0
0
0
0
0
VA
0
1 (12.5)
0
2 (25)
2 (12.5)
BA
1 (12.5)
4 (50)
1 (12.5)
3 (37.5)
4 (25)
PCA
0
0
0
0
0
ICA, Internal Cervical Artery, M1 M1 segment of the middle cerebral artery, M2/3 M2/3 segment of the middle cerebral artery, ACA Anterior Cerebral Artery, VA Vertebral Artery, BA Basilar Artery, PCA Posterior Cerebral Artery

Workflow Data

4/16 patients had unknown onset of AIS (p = 0.715). Onset-to-image time was without significant difference between both groups (CT: 231 min, IQR 96–367; FD-CT: 203 min, IQR 191–262; p = 0.928). 2/8 (25%) patients of the FD-CT group and 3/8 patients (37.5%) of the CT group were presented during off-hours (6 pm till 8 am or on weekend; p = 0.721).
Door-to-image time showed no significant difference between the CT group (30 min, IQR 27–58) and the FD-CT group (44.5 min, IQR 31–55; p = 0.491).
Image-to-groin-puncture time was significantly shorter for patients that received multimodal FD-CT prior to EVT (14 min, IQR 12–18), when compared to the CT group (44 min, IQR 30–50, p < 0.001). Thus, door-to-groin-puncture time was significantly reduced when multimodal FD-CT was applied (CT: 79.5 min, IQR 65–90; FD-CT: 59.5 min, IQR 51–67; p = 0.016).
Image-to-reperfusion time (CT: 103 min, IQR 68–119; FD-CT: 99.5 min, IQR 54–129; p = 0.875) and groin-puncture-to-reperfusion time (CT: 54 min, IQR 32–75; FD-CT: 88 min, IQR 42–114; p = 0.165) showed no significant difference between both groups (Table 5).
Table 5
Process times; time metrics that represents patient delivery to the imaging modalities (onset-to-image and door-to-image time) did not differ significantly. Neither did the time metrics that represents the time of patient treatment with EVT (image-to-reperfusion and groin-puncture-to-reperfusion time). The time intervals that include patient arrival, patient imaging, respectively, to the start of the EVT is significantly reduced in the FD-CT group
 
Multimodal CT (n = 8)
Multimodal FD-CT (n = 8)
p Value
Time interval [min]a
   
onset-to-image
231 (96–367)
203 (191–262)
0.928
door-to-image
30 (27–58)
44.5 (31–55)
0.491
door-to-groin-puncture
79.5 (65–90)
59.5 (51–67)
0.016
image-to-groin-puncture
44 (30–50)
14 (12–18)
 < 0.001
image-to-reperfusion
103 (68–119)
99.5 (54–129)
0.875
groin-puncture-to-reperfusion
54 (32–75)
88 (42–114)
0.165
amedian (IQR 25th-75th percentile)

Discussion

In this small series, we could show that using a new fully multimodal FD-CT approach for diagnosis of LVO in AIS is feasible. Moreover, in our series door-to-groin-puncture times were reduced significantly compared to conventional multimodal CT even though NE-FDCT, FD-CTP and FD-CTA is performed. To our knowledge, this is the first study examining this new FD-CT application in outpatients with AIS due to LVO (Figs. 2 and 3).
Current work of Psychogios et al., who investigated the impact of first-line FD-CT imaging on workflow in AIS patients who presented at the ECC first, draw comparable conclusions as we did in our study: first-line imaging within the angiosuite can significantly reduce intrahospital delay [11].
In line with other current literature our study indicates that by using FD-CT first-line, ‘one-stop-shopping’ can be achieved in outpatients, which reduces the door-to-groin-puncture time and consecutively door-to-reperfusion time [18, 19]. Especially in a clinical setting, with long distances between ER, CT and the angiosuite, time delay by intrahospital transit plays a large role. As Khatri et al. demonstrated, a 30-min delay in angiographic perfusion reduces the relative likelihood of good clinical outcome (mRS of 0–2) by 14% [20]. FD-CT could offer the opportunity to reduce this delay as the transit concentrates on the direction from the ER to the angiosuite.
However, when compared to aforesaid studies there are methodical differences to our new FD-CT approach. As 15% of all AIS are based on carotid tandem occlusions, defined as both, extra- and intracranial occlusion, the need of imaging cervical vasculature is obvious [20]. Previous multimodal FD-CT imaging trials lack on imaging cervical vasculature [13]. Our approach aims for a fast imaging of the cervical vasculature within 4 s of scanning time using bolus watching technique. The study group of Psychogios et al. used a biphasic angiographic approach [11, 13]. This technique offers high-quality images of the intracranial vasculature, however, limited to the skull [21]. With our new multimodal FD-CT protocol including a FD-CTA acquisition with extended FOV imaging from the aortic arch up to M3 segment level is feasible instead. Despite FD-CTA offers information on cervical vasculature, it is limited by its FOV, which currently covers 49 cm. Thus, imaging from aortic arch and full brain coverage is not feasible. Potential protocol adjustments, e.g., FD-CTA for visualization of the cervical vasculature and FD-CTP for visualization of the cerebral vessel, might be considered to overcome this drawback.
The aforesaid studies did not apply perfusion imaging in their study, whereas our approach includes a dynamic perfusion scan. Subsequently, dedicated high-quality imaging of collateral status and clot burden is possible as previously shown [23]. Recent work of Brehm et al. showed reduced door-to-groin-puncture times in AIS patients when applying a perfusion based FD-CT-approach [12]. They used a perfusion protocol, which is similar to that applied in our study. However, as their workflow did not include FD-CTA, imaging of the cervical vasculature was not performed.
To our knowledge, we provide data on real multimodal FD-CT imaging in AIS patients for the first time, proving that additional imaging of the cervical vasculature is feasible within the angiosuite. Thus, a CT-like diagnostic workup of AIS seems possible when using FD-CT only.
In our study, the suggested door-to-groin-puncture-time of less than 60 min was achieved within the FD-CT cohort and is lower as times reported by the HERMES collaboration [24, 25].
Unfortunately, the fast-imaging workup of the FD-CT cohort could not be transferred to faster image-to-reperfusion times (p = 0.875). As both groups did not significantly differ with regard to the number of performed EVT passes (p = 0.382), this might be addressed by difficult access to the clot, which cannot be affected by the choice of imaging. Moreover, our small and selected study population might have hindered advantageous speed of reperfusion for the FD-CT group. However, our inclusion criterion of the patient cohort was the externally performed GA. This was done to minimize any bias of intrahospital workflow times. The predominance of posterior LVO in the CT group might be partially explained by this approach, as imbalances regarding the site of LVO, or LVO access were not addressed equally. Thus, assessments of larger cohorts of the anterior and posterior circulation are warranted.
In analogy to multimodal CT, reconstructing non-enhanced images, cerebral perfusion images and the cerebral vasculature out of the obtained FD-CT datasets is mandatory. The speed of the image acquisition is short. The acquisition time is 7 s for the NE-FDCT, 60 s for the FD-CTP and another 4 s for the FD-CTA. Reconstruction time is comparable to that of multimodal CT but depends on the operators’ experience. To our knowledge time of post-processing does not play a role when comparing both modalities. In all patients, software reconstruction was successful and offered information of impaired brain hemodynamics.
FD-CT image quality of brain parenchyma is inferior when compared to CT. Especially with regard to the assessment of early ischemic changes and evaluation of the Alberta Stroke Program Early CT Score (ASPECTS), respectively [26]. The delineation of SAH depiction, especially near the skull base, was reported to be reduced as well [27, 28]. However, Leyhe et al. recently showed that the latest type of FD-CT detector offers high sensitivity and specificity in intracranial hemorrhage detection [29]. Nevertheless, NE-CT and CTA data were superior in the qualitative rating. The use of an alternative NE-FDCT protocol might overcome this drawback in parts, as there are studies reporting on superior depiction of cerebral vasculature when applying FD-CTA [30]. However, these studies use different programs, dedicated for intracranial vessel imaging. Nonetheless, although image quality was rated inferior for FD-CTA in our study, all FD-CT datasets were sufficient for LVO-detection, just like the CT datasets. Both showed excellent interrater agreement, as well as an excellent correlation to the subsequent DSA series.
To our knowledge this is the first paper describing an “one-stop-shopping” approach with integrated AI-based perfusion assessment performed with RAPID ANGIO. Automated image processing using RAPID software was feasible in all cases. The FD-CTP datasets showed equivalent image quality when reconstructed, offering the information needed to estimate infarct core and penumbra. Especially for readers with less experience in perfusion imaging automated software applications offer support in image evaluation. Whether automated perfusion analysis using RAPID software differs with regard to volumes when comparing CTP and FD-CTP has not been addressed yet. As our cohorts are different with regard to occlusion site—though not significant due to the small number of patients—comparative statements are not possible. Niu et al. showed, that automated FD-CTP postprocessing is comparable to CTP [31]. By using automated software solutions, reconstruction and interpretation of perfusion data might help physicians with clinical decision making. Thus, the workflow might get more streamlined.
With regard to dosage measurement, a comparable amount of doses has already been described for FD-CT and CT imaging [32]. Dedicated measurement of effective doses for the 7 s NE-FDCT Sine Spin run and the 4 s FD-CTA are still missing and are subject of running studies. However, due to the rotation angle of 200° dosimetry on FD-CT in comparison with CT has to be considered as an approximation.
The present study has several limitations. First, it is in parts retrospectively designed and monocentric, which bears the risk of selection bias. Second, our study cohort is relatively small and limited on outpatients that have already received GA. In order to focus on transfer times that are not influenced by GA on site, we decided to choose this inclusion criterion. However, this criterion has hindered this study to include more patients, especially for the retrospective CT cohort. Third, the patients that received CT imaging had predominantly occlusions of the posterior circulation.

Conclusion

Using a new extended multimodal FD-CT protocol, diagnostic imaging within the angiosuite is a promising attempt to streamline the AIS workflow. Our small series showed that by using FD-CT, the time span between imaging and EVT can be speed-up. However, dedicated workflow-analyses on larger patient cohorts are needed and improvements in organization and interdisciplinary collaboration are essential to guarantee a treatment in shortest time possible.

Declarations

Ethics Approval

The study was conducted according to the guidelines of the Declaration of Helsinki, and approved by the Institutional Review Board of University Hospital Erlangen.
All procedures were performed for clinical indication in accordance with the presumed patient will. All FDCT and CT applications have CE-approval, except the Siemens perfusion prototype software. With regard to the Siemens perfusion prototype software, the concepts and information presented in this paper are based on research and are not commercially available.
We confirm that the manuscript has been read and approved by all named authors.

Conflicts of Interest

On behalf of all authors, the corresponding author states that there is no conflict of interest. M.M. – UNRELATED: Employment: Siemens Healthcare GmbH.
Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​.

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

e.Med Radiologie

Kombi-Abonnement

Mit e.Med Radiologie erhalten Sie Zugang zu CME-Fortbildungen des Fachgebietes Radiologie, den Premium-Inhalten der radiologischen Fachzeitschriften, inklusive einer gedruckten Radiologie-Zeitschrift Ihrer Wahl.

Literatur
1.
Zurück zum Zitat Berkhemer OA, Fransen PS, Beumer D, et al. A randomized trial of intraarterial treatment for acute ischemic stroke. N Engl J Med 2015;372:11-20.CrossRefPubMed Berkhemer OA, Fransen PS, Beumer D, et al. A randomized trial of intraarterial treatment for acute ischemic stroke. N Engl J Med 2015;372:11-20.CrossRefPubMed
2.
Zurück zum Zitat Goyal M, Demchuk AM, Menon BK, et al. Randomized assessment of rapid endovascular treatment of ischemic stroke. N Engl J Med 2015;372:1019-1030.CrossRefPubMed Goyal M, Demchuk AM, Menon BK, et al. Randomized assessment of rapid endovascular treatment of ischemic stroke. N Engl J Med 2015;372:1019-1030.CrossRefPubMed
3.
Zurück zum Zitat Saver JL, Goyal M, Bonafe A, et al. Stent-Retriever Thrombectomy after Intravenous t-PA vs. t-PA Alone in Stroke. N Engl J Med 2015. Saver JL, Goyal M, Bonafe A, et al. Stent-Retriever Thrombectomy after Intravenous t-PA vs. t-PA Alone in Stroke. N Engl J Med 2015.
4.
Zurück zum Zitat Campbell BC, Mitchell PJ, Kleinig TJ, et al. Endovascular therapy for ischemic stroke with perfusion-imaging selection. N Engl J Med 2015;372:1009-1018.CrossRefPubMed Campbell BC, Mitchell PJ, Kleinig TJ, et al. Endovascular therapy for ischemic stroke with perfusion-imaging selection. N Engl J Med 2015;372:1009-1018.CrossRefPubMed
5.
Zurück zum Zitat Nogueira RG, Jadhav AP, Haussen DC, et al. Thrombectomy 6 to 24 Hours after Stroke with a Mismatch between Deficit and Infarct. N Engl J Med 2017. Nogueira RG, Jadhav AP, Haussen DC, et al. Thrombectomy 6 to 24 Hours after Stroke with a Mismatch between Deficit and Infarct. N Engl J Med 2017.
6.
Zurück zum Zitat Bourcier R, Goyal M, Liebeskind DS, et al. Association of Time From Stroke Onset to Groin Puncture With Quality of Reperfusion After Mechanical Thrombectomy: A Meta-analysis of Individual Patient Data From 7 Randomized Clinical Trials. JAMA Neurol 2019;76:405-411.CrossRefPubMedPubMedCentral Bourcier R, Goyal M, Liebeskind DS, et al. Association of Time From Stroke Onset to Groin Puncture With Quality of Reperfusion After Mechanical Thrombectomy: A Meta-analysis of Individual Patient Data From 7 Randomized Clinical Trials. JAMA Neurol 2019;76:405-411.CrossRefPubMedPubMedCentral
7.
Zurück zum Zitat Mehta BP, Leslie-Mazwi TM, Chandra RV, et al. Reducing door-to-puncture times for intra-arterial stroke therapy: a pilot quality improvement project. J Am Heart Assoc 2014;3:e000963.CrossRefPubMedPubMedCentral Mehta BP, Leslie-Mazwi TM, Chandra RV, et al. Reducing door-to-puncture times for intra-arterial stroke therapy: a pilot quality improvement project. J Am Heart Assoc 2014;3:e000963.CrossRefPubMedPubMedCentral
8.
Zurück zum Zitat Hill MD, Goyal M, Menon BK, et al. Efficacy and safety of nerinetide for the treatment of acute ischaemic stroke (ESCAPE-NA1): a multicentre, double-blind, randomised controlled trial. Lancet 2020;395:878-887.CrossRefPubMed Hill MD, Goyal M, Menon BK, et al. Efficacy and safety of nerinetide for the treatment of acute ischaemic stroke (ESCAPE-NA1): a multicentre, double-blind, randomised controlled trial. Lancet 2020;395:878-887.CrossRefPubMed
9.
Zurück zum Zitat Goyal M, Jadhav AP, Bonafe A, et al. Analysis of Workflow and Time to Treatment and the Effects on Outcome in Endovascular Treatment of Acute Ischemic Stroke: Results from the SWIFT PRIME Randomized Controlled Trial. Radiology 2016;279:888-897.CrossRefPubMed Goyal M, Jadhav AP, Bonafe A, et al. Analysis of Workflow and Time to Treatment and the Effects on Outcome in Endovascular Treatment of Acute Ischemic Stroke: Results from the SWIFT PRIME Randomized Controlled Trial. Radiology 2016;279:888-897.CrossRefPubMed
10.
Zurück zum Zitat Holodinsky JK, Williamson TS, Kamal N, Mayank D, Hill MD, Goyal M. Drip and Ship Versus Direct to Comprehensive Stroke Center: Conditional Probability Modeling. Stroke 2017;48:233-238.CrossRefPubMed Holodinsky JK, Williamson TS, Kamal N, Mayank D, Hill MD, Goyal M. Drip and Ship Versus Direct to Comprehensive Stroke Center: Conditional Probability Modeling. Stroke 2017;48:233-238.CrossRefPubMed
11.
Zurück zum Zitat Psychogios MN, Behme D, Schregel K, et al. One-Stop Management of Acute Stroke Patients: Minimizing Door-to-Reperfusion Times. Stroke 2017;48:3152-3155.CrossRefPubMed Psychogios MN, Behme D, Schregel K, et al. One-Stop Management of Acute Stroke Patients: Minimizing Door-to-Reperfusion Times. Stroke 2017;48:3152-3155.CrossRefPubMed
12.
Zurück zum Zitat Brehm A, Tsogkas I, Maier IL, et al. One-Stop Management with Perfusion for Transfer Patients with Stroke due to a Large-Vessel Occlusion: Feasibility and Effects on In-Hospital Times. AJNR Am J Neuroradiol 2019;40:1330-1334.CrossRefPubMedPubMedCentral Brehm A, Tsogkas I, Maier IL, et al. One-Stop Management with Perfusion for Transfer Patients with Stroke due to a Large-Vessel Occlusion: Feasibility and Effects on In-Hospital Times. AJNR Am J Neuroradiol 2019;40:1330-1334.CrossRefPubMedPubMedCentral
13.
Zurück zum Zitat Psychogios MN, Maier IL, Tsogkas I, et al. One-Stop Management of 230 Consecutive Acute Stroke Patients: Report of Procedural Times and Clinical Outcome. J Clin Med 2019;8. Psychogios MN, Maier IL, Tsogkas I, et al. One-Stop Management of 230 Consecutive Acute Stroke Patients: Report of Procedural Times and Clinical Outcome. J Clin Med 2019;8.
14.
Zurück zum Zitat Kalender WA, Kyriakou Y. Flat-detector computed tomography (FD-CT). Eur Radiol 2007; 17(11):2767-79.CrossRefPubMed Kalender WA, Kyriakou Y. Flat-detector computed tomography (FD-CT). Eur Radiol 2007; 17(11):2767-79.CrossRefPubMed
15.
Zurück zum Zitat Flaherty ML, Kissela B, Khoury JC, et al. Carotid artery stenosis as a cause of stroke. Neuroepidemiology 2013;40:36-41.CrossRefPubMed Flaherty ML, Kissela B, Khoury JC, et al. Carotid artery stenosis as a cause of stroke. Neuroepidemiology 2013;40:36-41.CrossRefPubMed
16.
Zurück zum Zitat Kaschka IN, Kloska SP, Struffert T, et al. Clot Burden and Collaterals in Anterior Circulation Stroke: Differences Between Single-Phase CTA and Multi-phase 4D-CTA. Clinical neuroradiology 2016;26:309-315.CrossRefPubMed Kaschka IN, Kloska SP, Struffert T, et al. Clot Burden and Collaterals in Anterior Circulation Stroke: Differences Between Single-Phase CTA and Multi-phase 4D-CTA. Clinical neuroradiology 2016;26:309-315.CrossRefPubMed
17.
Zurück zum Zitat Koo TK, Li MY. A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research. J Chiropr Med 2016;15:155-163.CrossRefPubMedPubMedCentral Koo TK, Li MY. A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research. J Chiropr Med 2016;15:155-163.CrossRefPubMedPubMedCentral
18.
Zurück zum Zitat Tong E, Komlosi P, Wintermark M. One-stop-shop stroke imaging with functional CT. Eur J Radiol 2015;84:2425-2431.CrossRefPubMed Tong E, Komlosi P, Wintermark M. One-stop-shop stroke imaging with functional CT. Eur J Radiol 2015;84:2425-2431.CrossRefPubMed
19.
Zurück zum Zitat Yang P, Niu K, Wu Y, et al. Time-Resolved C-Arm Computed Tomographic Angiography Derived From Computed Tomographic Perfusion Acquisition: New Capability for One-Stop-Shop Acute Ischemic Stroke Treatment in the Angiosuite. Stroke 2015;46:3383-3389.CrossRefPubMed Yang P, Niu K, Wu Y, et al. Time-Resolved C-Arm Computed Tomographic Angiography Derived From Computed Tomographic Perfusion Acquisition: New Capability for One-Stop-Shop Acute Ischemic Stroke Treatment in the Angiosuite. Stroke 2015;46:3383-3389.CrossRefPubMed
20.
Zurück zum Zitat Khatri P, Yeatts SD, Mazighi M, et al. Time to angiographic reperfusion and clinical outcome after acute ischaemic stroke: an analysis of data from the Interventional Management of Stroke (IMS III) phase 3 trial. Lancet Neurol 2014;13:567-574.CrossRefPubMedPubMedCentral Khatri P, Yeatts SD, Mazighi M, et al. Time to angiographic reperfusion and clinical outcome after acute ischaemic stroke: an analysis of data from the Interventional Management of Stroke (IMS III) phase 3 trial. Lancet Neurol 2014;13:567-574.CrossRefPubMedPubMedCentral
21.
Zurück zum Zitat de Castro-Afonso LH, Nakiri GS, Moretti Monsignore L, et al. Endovascular Reperfusion for Acute Isolated Cervical Carotid Occlusions: The Concept of "Hemodynamic Thrombectomy". Interv Neurol 2020;8:27-37.CrossRefPubMed de Castro-Afonso LH, Nakiri GS, Moretti Monsignore L, et al. Endovascular Reperfusion for Acute Isolated Cervical Carotid Occlusions: The Concept of "Hemodynamic Thrombectomy". Interv Neurol 2020;8:27-37.CrossRefPubMed
22.
Zurück zum Zitat Maier IL, Scalzo F, Leyhe JR, et al. Validation of collateral scoring on flat-detector multiphase CT angiography in patients with acute ischemic stroke. PLoS One 2018;13:e0202592.CrossRefPubMedPubMedCentral Maier IL, Scalzo F, Leyhe JR, et al. Validation of collateral scoring on flat-detector multiphase CT angiography in patients with acute ischemic stroke. PLoS One 2018;13:e0202592.CrossRefPubMedPubMedCentral
23.
Zurück zum Zitat Yang P, Niu K, Wu Y, et al. Evaluation of Collaterals and Clot Burden Using Time-Resolved C-Arm Conebeam CT Angiography in the Angiography Suite: A Feasibility Study. AJNR Am J Neuroradiol 2017;38:747-752.CrossRefPubMedPubMedCentral Yang P, Niu K, Wu Y, et al. Evaluation of Collaterals and Clot Burden Using Time-Resolved C-Arm Conebeam CT Angiography in the Angiography Suite: A Feasibility Study. AJNR Am J Neuroradiol 2017;38:747-752.CrossRefPubMedPubMedCentral
24.
Zurück zum Zitat McTaggart RA, Ansari SA, Goyal M, et al. Initial hospital management of patients with emergent large vessel occlusion (ELVO): report of the standards and guidelines committee of the Society of NeuroInterventional Surgery. J Neurointerv Surg 2017;9:316-323.CrossRefPubMed McTaggart RA, Ansari SA, Goyal M, et al. Initial hospital management of patients with emergent large vessel occlusion (ELVO): report of the standards and guidelines committee of the Society of NeuroInterventional Surgery. J Neurointerv Surg 2017;9:316-323.CrossRefPubMed
25.
Zurück zum Zitat Saver JL, Goyal M, van der Lugt A, et al. Time to Treatment With Endovascular Thrombectomy and Outcomes From Ischemic Stroke: A Meta-analysis. JAMA 2016;316:1279-1288.CrossRefPubMed Saver JL, Goyal M, van der Lugt A, et al. Time to Treatment With Endovascular Thrombectomy and Outcomes From Ischemic Stroke: A Meta-analysis. JAMA 2016;316:1279-1288.CrossRefPubMed
26.
Zurück zum Zitat Struffert T, Deuerling-Zheng Y, Kloska S, et al. Flat detector CT in the evaluation of brain parenchyma, intracranial vasculature, and cerebral blood volume: a pilot study in patients with acute symptoms of cerebral ischemia. AJNR American journal of neuroradiology 2010;31:1462-1469.CrossRefPubMedPubMedCentral Struffert T, Deuerling-Zheng Y, Kloska S, et al. Flat detector CT in the evaluation of brain parenchyma, intracranial vasculature, and cerebral blood volume: a pilot study in patients with acute symptoms of cerebral ischemia. AJNR American journal of neuroradiology 2010;31:1462-1469.CrossRefPubMedPubMedCentral
27.
Zurück zum Zitat Doelken M, Struffert T, Richter G, et al. Flat-panel detector volumetric CT for visualization of subarachnoid hemorrhage and ventricles: preliminary results compared to conventional CT. Neuroradiology 2008;50:517-523.CrossRefPubMed Doelken M, Struffert T, Richter G, et al. Flat-panel detector volumetric CT for visualization of subarachnoid hemorrhage and ventricles: preliminary results compared to conventional CT. Neuroradiology 2008;50:517-523.CrossRefPubMed
28.
Zurück zum Zitat Doerfler A, Golitz P, Engelhorn T, Kloska S, Struffert T. Flat-Panel Computed Tomography (DYNA-CT) in Neuroradiology. From High-Resolution Imaging of Implants to One-Stop-Shopping for Acute Stroke. Clinical neuroradiology 2015;25 Suppl 2:291–297. Doerfler A, Golitz P, Engelhorn T, Kloska S, Struffert T. Flat-Panel Computed Tomography (DYNA-CT) in Neuroradiology. From High-Resolution Imaging of Implants to One-Stop-Shopping for Acute Stroke. Clinical neuroradiology 2015;25 Suppl 2:291–297.
29.
Zurück zum Zitat Leyhe JR, Tsogkas I, Hesse AC, et al. Latest generation of flat detector CT as a peri-interventional diagnostic tool: a comparative study with multidetector CT. Journal of neurointerventional surgery 2017;9:1253-1257.CrossRefPubMed Leyhe JR, Tsogkas I, Hesse AC, et al. Latest generation of flat detector CT as a peri-interventional diagnostic tool: a comparative study with multidetector CT. Journal of neurointerventional surgery 2017;9:1253-1257.CrossRefPubMed
30.
Zurück zum Zitat Saake M, Breuer L, Goelitz P, Ott S, Struffert T, Doerfler A. Flat detector computed tomography angiography with intravenous contrast application: feasibility for visualization of cerebral arterial vasculature. J Neuroimaging 2013;23:414-420.CrossRefPubMed Saake M, Breuer L, Goelitz P, Ott S, Struffert T, Doerfler A. Flat detector computed tomography angiography with intravenous contrast application: feasibility for visualization of cerebral arterial vasculature. J Neuroimaging 2013;23:414-420.CrossRefPubMed
31.
Zurück zum Zitat Niu K, Yang P, Wu Y, et al. C-Arm Conebeam CT Perfusion Imaging in the Angiographic Suite: A Comparison with Multidetector CT Perfusion Imaging. AJNR American journal of neuroradiology 2016;37:1303-1309.CrossRefPubMedPubMedCentral Niu K, Yang P, Wu Y, et al. C-Arm Conebeam CT Perfusion Imaging in the Angiographic Suite: A Comparison with Multidetector CT Perfusion Imaging. AJNR American journal of neuroradiology 2016;37:1303-1309.CrossRefPubMedPubMedCentral
32.
Zurück zum Zitat Brehm A, Stamm G, Lupke M, Riedel C, Stieltjes B, Psychogios MN. Effective dose to patient measurements for flat-detector computed tomography protocols in acute stroke care. European radiology 2020;30:5082-5088.CrossRefPubMed Brehm A, Stamm G, Lupke M, Riedel C, Stieltjes B, Psychogios MN. Effective dose to patient measurements for flat-detector computed tomography protocols in acute stroke care. European radiology 2020;30:5082-5088.CrossRefPubMed
Metadaten
Titel
Extended Multimodal Flat Detector CT Imaging in Acute Ischemic Stroke: A Pilot Study
verfasst von
Philip Hoelter
Stefan Lang
Vanessa Beuscher
Bernd Kallmuenzer
Michael Manhart
Stefan Schwab
Arnd Doerfler
Publikationsdatum
17.01.2023
Verlag
Springer International Publishing
Erschienen in
Journal of Imaging Informatics in Medicine / Ausgabe 3/2023
Print ISSN: 2948-2925
Elektronische ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-022-00699-4

Weitere Artikel der Ausgabe 3/2023

Journal of Digital Imaging 3/2023 Zur Ausgabe

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.