Skip to main content
Erschienen in: Current Oral Health Reports 4/2019

18.11.2019 | Modern Production Laboratory Advances in Dental Technology (M Bergler and E Steger, Section Editors)

Factors Affecting the Marginal Fit of CAD-CAM Restorations and Concepts to Improve Outcomes

verfasst von: Alan Atlas, Wael Isleem, Michael Bergler, Howard P. Fraiman, Ricardo Walter, Nathaniel D. Lawson

Erschienen in: Current Oral Health Reports | Ausgabe 4/2019

Einloggen, um Zugang zu erhalten

Abstract

Purpose of Review

With the advent of CAD-CAM technology, it is essential to examine factors that affect outcomes of restorations fabricated by the new methodologies.

Recent Findings

This report assesses and compares ceramic crown fabrication systems to determine what factors affect marginal fit and provide solutions for better outcomes.

Summary

The review revealed key scientific evidence about what factors influence the marginal fit of CAD-CAM ceramic restorations. Solutions were recommended to help the clinician achieve greater long-term success when providing this treatment to their patients. The dental microscope enables the dental practitioner to achieve improved clinical outcomes in all phases of restorative dentistry, especially CAD-CAM restorations.
Literatur
1.
Zurück zum Zitat • Boitelle P, Mawussi B, Tapie L, Fromentin O. A systematic review of CAD/CAM fit restoration evaluations. J Oral Rehabil. 2014;41:853–74. https://doi.org/10.1111/joor.12205This review emphasized deficiency in the number of clinical studies on accuracy of CAD-CAM restorations and inconsistency in protocols preclude solid evidenced based conclusions.CrossRef • Boitelle P, Mawussi B, Tapie L, Fromentin O. A systematic review of CAD/CAM fit restoration evaluations. J Oral Rehabil. 2014;41:853–74. https://​doi.​org/​10.​1111/​joor.​12205This review emphasized deficiency in the number of clinical studies on accuracy of CAD-CAM restorations and inconsistency in protocols preclude solid evidenced based conclusions.CrossRef
2.
4.
Zurück zum Zitat •• Schestatsky R, Zucuni CP, Venturini AB, de Lima Burgo TA, Bacchi A, Valandro LF, et al. CAD-CAM milled versus pressed lithium-disilicate monolithic crowns adhesively cemented after distinct surface treatments: fatigue performance and ceramic surface characteristics. J Mech Behav Biomed Mater. 2019;94:144–54. https://doi.org/10.1016/j.jmbbm.2019.03.005This study compared CAD/CAM’s different classes of materials possessing various levels of machinability compared to pressed manufacturing.CrossRefPubMed •• Schestatsky R, Zucuni CP, Venturini AB, de Lima Burgo TA, Bacchi A, Valandro LF, et al. CAD-CAM milled versus pressed lithium-disilicate monolithic crowns adhesively cemented after distinct surface treatments: fatigue performance and ceramic surface characteristics. J Mech Behav Biomed Mater. 2019;94:144–54. https://​doi.​org/​10.​1016/​j.​jmbbm.​2019.​03.​005This study compared CAD/CAM’s different classes of materials possessing various levels of machinability compared to pressed manufacturing.CrossRefPubMed
13.
Zurück zum Zitat Ural C, Burgaz Y, Saraç D. In vitro evaluation of marginal adaptation in five ceramic restoration fabricating techniques. Quintessence Int. 2010;41:585–90. PMID: 20614046 Ural C, Burgaz Y, Saraç D. In vitro evaluation of marginal adaptation in five ceramic restoration fabricating techniques. Quintessence Int. 2010;41:585–90. PMID: 20614046
33.
Zurück zum Zitat Albert FE, El-Mowafy OM. Marginal adaptation and microleakage of Procera AllCeram crowns with four cements. Int J Prosthodont. 2004;17:529–35.PubMed Albert FE, El-Mowafy OM. Marginal adaptation and microleakage of Procera AllCeram crowns with four cements. Int J Prosthodont. 2004;17:529–35.PubMed
39.
Zurück zum Zitat • Renne W, Wolf B, Kessler R, McPherson K, Mennito AS. Evaluation of the marginal fit of CAD/CAM crowns fabricated using two different chairside CAD/CAM systems on preparations of varying quality. J Esthet Restor Dent. 2015;27(4):194–202. https://doi.org/10.1111/jerd.12148This study demonstrated the importance of preparation over scanning and milling systems utilized.CrossRef • Renne W, Wolf B, Kessler R, McPherson K, Mennito AS. Evaluation of the marginal fit of CAD/CAM crowns fabricated using two different chairside CAD/CAM systems on preparations of varying quality. J Esthet Restor Dent. 2015;27(4):194–202. https://​doi.​org/​10.​1111/​jerd.​12148This study demonstrated the importance of preparation over scanning and milling systems utilized.CrossRef
40.
Zurück zum Zitat Rosenstiel SF, Land MF, Fujimoto J. Con- temporary fixed prosthodontics. 4th ed. St Louis: Mosby Elsevier; 2006. p. 325–7. Rosenstiel SF, Land MF, Fujimoto J. Con- temporary fixed prosthodontics. 4th ed. St Louis: Mosby Elsevier; 2006. p. 325–7.
41.
Zurück zum Zitat Shillingburg HT, Hobo S, Whitsett LD, Ja-Cobi R, Brackett SE. Fundamentals of fixed prosthodontics. 3rd ed. Chicago: Quintessence Publishing; 1997. p. 437. Shillingburg HT, Hobo S, Whitsett LD, Ja-Cobi R, Brackett SE. Fundamentals of fixed prosthodontics. 3rd ed. Chicago: Quintessence Publishing; 1997. p. 437.
42.
Zurück zum Zitat Hmaidouch R, Neumann P, Mueller WD. Influence of preparation form, luting space setting and cement type on the marginal and internal fit of CAD/ CAM crown copings. Int J Comput Dent. 2011;14:219–26.PubMed Hmaidouch R, Neumann P, Mueller WD. Influence of preparation form, luting space setting and cement type on the marginal and internal fit of CAD/ CAM crown copings. Int J Comput Dent. 2011;14:219–26.PubMed
49.
Zurück zum Zitat • Nedelcu R, Olsson P, Nyström I, Thor A. Finish line distinctness and accuracy in 7 intraoral scanners versus conventional impression: an in vitro descriptive comparison. BMC Oral Health. 2018;18(1):27. https://doi.org/10.1186/s12903-018-0489-3This study demonstrated the potential issues scanners have compared to conventional impressions. • Nedelcu R, Olsson P, Nyström I, Thor A. Finish line distinctness and accuracy in 7 intraoral scanners versus conventional impression: an in vitro descriptive comparison. BMC Oral Health. 2018;18(1):27. https://​doi.​org/​10.​1186/​s12903-018-0489-3This study demonstrated the potential issues scanners have compared to conventional impressions.
60.
Zurück zum Zitat Friedman MJ, Landesman HM. Microscope-assisted precision (MAP) dentistry. A challenge for new knowledge. J Calif Dent Assoc. 1998;26(12):900–5.PubMed Friedman MJ, Landesman HM. Microscope-assisted precision (MAP) dentistry. A challenge for new knowledge. J Calif Dent Assoc. 1998;26(12):900–5.PubMed
61.
Zurück zum Zitat Musikant BL, Cohen BI, Deutsch AS. The surgical microscope, not just for the specialist. N Y State Dent J. 1996;62(8):33–5.PubMed Musikant BL, Cohen BI, Deutsch AS. The surgical microscope, not just for the specialist. N Y State Dent J. 1996;62(8):33–5.PubMed
Metadaten
Titel
Factors Affecting the Marginal Fit of CAD-CAM Restorations and Concepts to Improve Outcomes
verfasst von
Alan Atlas
Wael Isleem
Michael Bergler
Howard P. Fraiman
Ricardo Walter
Nathaniel D. Lawson
Publikationsdatum
18.11.2019
Verlag
Springer International Publishing
Erschienen in
Current Oral Health Reports / Ausgabe 4/2019
Elektronische ISSN: 2196-3002
DOI
https://doi.org/10.1007/s40496-019-00245-2

Weitere Artikel der Ausgabe 4/2019

Current Oral Health Reports 4/2019 Zur Ausgabe

Modern Approaches to Endodontics (S Kim and B Karabucak, Section Editors)

Beyond Endodontic MicroSurgery 2: Transplantation

Modern Production Laboratory Advances in Dental Technology (M Bergler and E Steger, Section Editors)

Facially Driven Digital Diagnostic Waxing: New Software Features to Simulate and Define Restorative Outcomes

Modern Production Laboratory Advances in Dental Technology (M Bergler and E Steger, Section Editors)

3D Printing of Zirconia–What is the Future?

Modern Approaches to Endodontics (S Kim and B Karabucak, Section Editors)

Beyond Endodontic MicroSurgery 1: Intentional Replantation

Dental Restorative Materials (M Özcan and P Cesar, Section Editor)

Current Developments on Enamel and Dentin Remineralization

Parodontalbehandlung verbessert Prognose bei Katheterablation

19.04.2024 Vorhofflimmern Nachrichten

Werden Personen mit Vorhofflimmern in der Blanking-Periode nach einer Katheterablation gegen eine bestehende Parodontitis behandelt, verbessert dies die Erfolgsaussichten. Dafür sprechen die Resultate einer prospektiven Untersuchung.

Invasive Zahnbehandlung: Wann eine Antibiotikaprophylaxe vor infektiöser Endokarditis schützt

11.04.2024 Endokarditis Nachrichten

Bei welchen Personen eine Antibiotikaprophylaxe zur Prävention einer infektiösen Endokarditis nach invasiven zahnärztlichen Eingriffen sinnvoll ist, wird diskutiert. Neue Daten stehen im Einklang mit den europäischen Leitlinienempfehlungen.

Zell-Organisatoren unter Druck: Mechanismen des embryonalen Zahnwachstums aufgedeckt

08.04.2024 Zahnmedizin Nachrichten

Der Aufbau von Geweben und Organen während der Embryonalentwicklung wird von den Zellen bemerkenswert choreografiert. Für diesen Prozess braucht es spezielle sogenannte „Organisatoren“. In einer aktuellen Veröffentlichung im Fachjournal Nature Cell Biology berichten Forschende durch welchen Vorgang diese Organisatoren im Gewebe entstehen und wie sie dann die Bildung von Zähnen orchestrieren.

Die Oralprophylaxe & Kinderzahnheilkunde umbenannt

11.03.2024 Kinderzahnmedizin Nachrichten

Infolge der Umbenennung der Deutschen Gesellschaft für Kinderzahnheilkunde in Deutsche Gesellschaft für Kinderzahnmedizin (DGKiZ) wird deren Mitgliederzeitschrift Oralprophylaxe & Kinderzahnheilkunde in Oralprophylaxe & Kinderzahnmedizin umbenannt. Aus diesem Grunde trägt die erste Ausgabe in 2024 erstmalig den neuen Titel.

Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.