Skip to main content
Erschienen in: Netherlands Heart Journal 1/2008

01.01.2008 | article

Fifty years of cardiac pacing: the dark side of the moon?

verfasst von: C. C. de Cock

Erschienen in: Netherlands Heart Journal | Ausgabe 1/2008

Einloggen, um Zugang zu erhalten

Abstract

Fifty years after its introduction, cardiac pacing has evolved from an experimental medical treatment to an expanding field in today's cardiology. Only recently there is accumulating evidence that prolonged stimulation of the right ventricular apex is associated with clinically significant adverse effects. In this commentary, the potential adverse effects are summarised and potential modifications in contemporary pacing are discussed. (Neth Heart J 2008;16(suppl 1):S12-S14.)
Literatur
1.
Zurück zum Zitat Report of the World Health Organization (WHO): World health statistics 2008. ISBN 978 92 4 156359 8 (NLM classification: WA 900.1). Report of the World Health Organization (WHO): World health statistics 2008. ISBN 978 92 4 156359 8 (NLM classification: WA 900.1).
2.
Zurück zum Zitat Maisel W, Moynahan M, Zuckerman B, Gross T, Tovar O, Tillmann D, et al. Pacemaker and ICD generator malfunctions. Analysis of Food and Drug Administration annual report. JAMA 2006;295:1901-6. Maisel W, Moynahan M, Zuckerman B, Gross T, Tovar O, Tillmann D, et al. Pacemaker and ICD generator malfunctions. Analysis of Food and Drug Administration annual report. JAMA 2006;295:1901-6.
3.
Zurück zum Zitat Wiggers CJ. The muscular reactions of the mammalian ventricles to artificial surface stimuli. Am J Physiol 1925;37C:275-82. Wiggers CJ. The muscular reactions of the mammalian ventricles to artificial surface stimuli. Am J Physiol 1925;37C:275-82.
4.
Zurück zum Zitat Tse HF, Lau CP. Long-term effect of right ventricular pacing on myocardial perfusion and function. J Am Coll Cardiol 1997;29: 744-9. Tse HF, Lau CP. Long-term effect of right ventricular pacing on myocardial perfusion and function. J Am Coll Cardiol 1997;29: 744-9.
5.
Zurück zum Zitat Tantengco MV,Thomas RL, Karpawich PP. Left ventricular dysfunction after long-term right ventricular apical pacing in the young, J Am Coll Cardiol 2001;37:2093-100. Tantengco MV,Thomas RL, Karpawich PP. Left ventricular dysfunction after long-term right ventricular apical pacing in the young, J Am Coll Cardiol 2001;37:2093-100.
6.
Zurück zum Zitat Connolly SJ, Kerr CR, Gent M, Roberts R, Yusuf S, Gillis AM, et al. Canadian Trial of Physiologic Pacing Investigators, Effects of physiologic pacing versus ventricular pacing on the risk of stroke and death due to cardiovascular causes. N Engl J Med 2000;342:1385-91. Connolly SJ, Kerr CR, Gent M, Roberts R, Yusuf S, Gillis AM, et al. Canadian Trial of Physiologic Pacing Investigators, Effects of physiologic pacing versus ventricular pacing on the risk of stroke and death due to cardiovascular causes. N Engl J Med 2000;342:1385-91.
7.
Zurück zum Zitat Lamas GA, Lee KL, Sweeney MO, Silverman R, Leon A, Yee R, et al. Ventricular pacing or dual-chamber pacing for sinus-node dysfunction. N Engl J Med 2002;346:1854-62. Lamas GA, Lee KL, Sweeney MO, Silverman R, Leon A, Yee R, et al. Ventricular pacing or dual-chamber pacing for sinus-node dysfunction. N Engl J Med 2002;346:1854-62.
8.
Zurück zum Zitat Sweeney MO, Hellkamp AS, Ellenbogen KE, Greenspon AJ, Freedman RA, Lee KL, et al. Adverse effect of ventricular pacing on heart failure and atrial fibrillation among patients with normal baseline QRS duration in a clinical trial of pacemaker therapy for sinus node dysfunction. Circulation 2003;107:2932-7. Sweeney MO, Hellkamp AS, Ellenbogen KE, Greenspon AJ, Freedman RA, Lee KL, et al. Adverse effect of ventricular pacing on heart failure and atrial fibrillation among patients with normal baseline QRS duration in a clinical trial of pacemaker therapy for sinus node dysfunction. Circulation 2003;107:2932-7.
9.
Zurück zum Zitat The DAVID Trial Investigators. Dual-chamber pacing or ventricular backup pacing in patients with an implantble defibrillator: The Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial. JAMA 2002;288:3115-23. The DAVID Trial Investigators. Dual-chamber pacing or ventricular backup pacing in patients with an implantble defibrillator: The Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial. JAMA 2002;288:3115-23.
10.
Zurück zum Zitat Steinberg JS, Fischer A, Wang P, Schuger C, Daubert C, McNitt S, et al. The clinical implications of cumulative ventricular pacing in the Multicenter Automatic Defibrillator Trial (MADIT II). J Cardiovasc Electrophysiol 2005;16:359-65. Steinberg JS, Fischer A, Wang P, Schuger C, Daubert C, McNitt S, et al. The clinical implications of cumulative ventricular pacing in the Multicenter Automatic Defibrillator Trial (MADIT II). J Cardiovasc Electrophysiol 2005;16:359-65.
11.
Zurück zum Zitat Nielsen JC, Pedersen AK, Mortensen PT, Pedersen OL, Pedersen AK, et al. Programming a fixed long atrioventricular delay is not effective in preventing ventricular pacing in patients with sick sinus syndrome. Europace 1999;1:113-20. Nielsen JC, Pedersen AK, Mortensen PT, Pedersen OL, Pedersen AK, et al. Programming a fixed long atrioventricular delay is not effective in preventing ventricular pacing in patients with sick sinus syndrome. Europace 1999;1:113-20.
12.
Zurück zum Zitat Sweeney MO, Shea JB, Fox V. Randomized trial of a new atrial-based minimal ventricular pacing mode in dual chamber implantable cardioverter-defibrillators: MVP. Heart Rhythm 2004;1:60-7. Sweeney MO, Shea JB, Fox V. Randomized trial of a new atrial-based minimal ventricular pacing mode in dual chamber implantable cardioverter-defibrillators: MVP. Heart Rhythm 2004;1:60-7.
13.
Zurück zum Zitat Sweeney MO, Bank AJ, Nsah E. Koullick M, Zeng QC, Hettrick D, et al. Minimizing ventricular pacing to reduce atrial fibrillation in sinus-node disease. N Engl J Med 2007;357:1000-8. Sweeney MO, Bank AJ, Nsah E. Koullick M, Zeng QC, Hettrick D, et al. Minimizing ventricular pacing to reduce atrial fibrillation in sinus-node disease. N Engl J Med 2007;357:1000-8.
14.
Zurück zum Zitat Deshmukh P, Casavant DA, Romanyshyn M, Anderson K. Permanent, direct His-bundle pacing, a novel approach to cardiac pacing in patients with normal His-Purkinje activation. Circulation 2000;101:869-77. Deshmukh P, Casavant DA, Romanyshyn M, Anderson K. Permanent, direct His-bundle pacing, a novel approach to cardiac pacing in patients with normal His-Purkinje activation. Circulation 2000;101:869-77.
15.
Zurück zum Zitat de Cock CC, Giudici MC, Twisk JW. Comparison of the haemo-dynamic effects of right ventricular outflow-tract pacing with right ventricular apex pacing. Europace 2003;5:275-8. de Cock CC, Giudici MC, Twisk JW. Comparison of the haemo-dynamic effects of right ventricular outflow-tract pacing with right ventricular apex pacing. Europace 2003;5:275-8.
16.
Zurück zum Zitat Giudici MC, Karpawich PP. Alternative pacing sites: it's time to define terms. Pacing Clin Cardiol 1999;22:551-3. Giudici MC, Karpawich PP. Alternative pacing sites: it's time to define terms. Pacing Clin Cardiol 1999;22:551-3.
17.
Zurück zum Zitat Lieberman R, Padeletti L, Schreuderr J, Jackson K. Michelucci A, Colella A, et al. Ventricular pacing lead position alters systemic hemodynamics and left ventricular function in patients with and without reduced ejection fraction. J Am Coll Cardiol 2006;48:1634-41. Lieberman R, Padeletti L, Schreuderr J, Jackson K. Michelucci A, Colella A, et al. Ventricular pacing lead position alters systemic hemodynamics and left ventricular function in patients with and without reduced ejection fraction. J Am Coll Cardiol 2006;48:1634-41.
18.
Zurück zum Zitat Varma C, O'Callaghan P, Mahon NG, Hnatkova K, McKenna W, Camm AJ, et al. Effects of multisite pacing on ventricular coordination. Heart 2002;87:322-8. Varma C, O'Callaghan P, Mahon NG, Hnatkova K, McKenna W, Camm AJ, et al. Effects of multisite pacing on ventricular coordination. Heart 2002;87:322-8.
Metadaten
Titel
Fifty years of cardiac pacing: the dark side of the moon?
verfasst von
C. C. de Cock
Publikationsdatum
01.01.2008
Verlag
Bohn Stafleu van Loghum
Erschienen in
Netherlands Heart Journal / Ausgabe 1/2008
Print ISSN: 1568-5888
Elektronische ISSN: 1876-6250
DOI
https://doi.org/10.1007/BF03086198

Weitere Artikel der Ausgabe 1/2008

Netherlands Heart Journal 1/2008 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

Niedriger diastolischer Blutdruck erhöht Risiko für schwere kardiovaskuläre Komplikationen

25.04.2024 Hypotonie Nachrichten

Wenn unter einer medikamentösen Hochdrucktherapie der diastolische Blutdruck in den Keller geht, steigt das Risiko für schwere kardiovaskuläre Ereignisse: Darauf deutet eine Sekundäranalyse der SPRINT-Studie hin.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Adipositas-Medikament auch gegen Schlafapnoe wirksam

24.04.2024 Adipositas Nachrichten

Der als Antidiabetikum sowie zum Gewichtsmanagement zugelassene Wirkstoff Tirzepatid hat in Studien bei adipösen Patienten auch schlafbezogene Atmungsstörungen deutlich reduziert, informiert der Hersteller in einer Vorab-Meldung zum Studienausgang.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.