Skip to main content
Erschienen in: Urolithiasis 6/2011

01.12.2011 | Original Paper

Flow matters: irrigation flow differs in flexible ureteroscopes of the newest generation

verfasst von: Stephan Kruck, Aristoteles G. Anastasiadis, Georgios Gakis, Ute Walcher, Joerg Hennenlotter, Axel S. Merseburger, Arnulf Stenzl, Udo Nagele

Erschienen in: Urolithiasis | Ausgabe 6/2011

Einloggen, um Zugang zu erhalten

Abstract

The development of new-generation flexible ureteroscopes has improved diagnostic and therapeutic endourological procedures. Despite technical improvement irrigation flow and quality of vision is often unsatisfactory. This study describes inter-manufactural differences in the latest available flexible ureteroscopes in terms of irrigation flow in correlation to different deflection angles and the use of 1.9 Fr. stone baskets. Irrigation flow measurements were performed in five new-generation flexible ureterorenoscopes with 3.6 Fr. working channels: Wolf (Uretero-Renoscope 270°), Storz (Flex-X² and Flex-Xc), ACMI (DUR-D) and Olympus (URF Type P5) in 0°, 90° and 180° deflection. All measurements were carried out five times with an empty working channel as well as with inserted 1.9 Fr. stone baskets. Mean flow rates with empty instruments (SD) counted 50 ml/min (0.8), 50 (1.0), 48 (1.7), 48 (1.6) and 44 (0.7) for ACMI, Wolf, Storz (FlexX² and Flex-Xc), and Olympus, respectively. Stone baskets significantly reduced irrigation flows in all tested ureteroscopes (p < 0.05). In channels with inserted baskets, the highest flow rates were measured for ACMI and Wolf with 12 ml/min (0.7) each. The lowest reduction of flow rate was detected in the ACMI and the Wolf ureteroscope (76.0%, 38 ml/min each). Measurements after flexion showed no significant differences between the ureteroscopes. Latest generation of flexible ureteroscopes offer various new product developments, including excellent deflection capacities. This study showed inter-manufactural differences in terms of irrigation flow rates with either empty or occupied working channels resulting in significant alterations in endoscopic view.
Literatur
1.
Zurück zum Zitat Abdelshehid C, Ahlering MT, Chou D, Park HK, Basillote J, Lee D, Kim I, Eichel L, Protsenko D, Wong B, McDougall E, Clayman RV (2005) Comparison of flexible ureteroscopes: deflection, irrigant flow and optical characteristics. J Urol 173:2017–2021PubMedCrossRef Abdelshehid C, Ahlering MT, Chou D, Park HK, Basillote J, Lee D, Kim I, Eichel L, Protsenko D, Wong B, McDougall E, Clayman RV (2005) Comparison of flexible ureteroscopes: deflection, irrigant flow and optical characteristics. J Urol 173:2017–2021PubMedCrossRef
2.
Zurück zum Zitat Andonian S, Okeke Z, Smith AD (2008) Digital ureteroscopy: the next step. J Endourol 22:603–606PubMedCrossRef Andonian S, Okeke Z, Smith AD (2008) Digital ureteroscopy: the next step. J Endourol 22:603–606PubMedCrossRef
3.
Zurück zum Zitat Honeck P, Nagele U, Michel MS (2008) Technical innovations in endourological stone therapy. Urologe A 47:587–590PubMedCrossRef Honeck P, Nagele U, Michel MS (2008) Technical innovations in endourological stone therapy. Urologe A 47:587–590PubMedCrossRef
4.
Zurück zum Zitat Mitchell S, Havranek E, Patel A (2008) First digital flexible ureterorenoscope: initial experience. J Endourol 22:47–50PubMedCrossRef Mitchell S, Havranek E, Patel A (2008) First digital flexible ureterorenoscope: initial experience. J Endourol 22:47–50PubMedCrossRef
5.
Zurück zum Zitat Monga M, Best S, Venkatesh R, Ames C, Lee C, Kuskowski M, Schwartz S, Vanlangendock R, Skenazy J, Landman J (2006) Durability of flexible ureteroscopes: a randomized, prospective study. J Urol 176:137–141PubMedCrossRef Monga M, Best S, Venkatesh R, Ames C, Lee C, Kuskowski M, Schwartz S, Vanlangendock R, Skenazy J, Landman J (2006) Durability of flexible ureteroscopes: a randomized, prospective study. J Urol 176:137–141PubMedCrossRef
6.
Zurück zum Zitat Nagele U, Horstmann M, Hennenlotter J, Walcher U, Kuczyk MA, Sievert KD, Stenzl A, Anastasiadis AG (2006) Size does matter: 1.5 Fr. stone baskets almost double irrigation flow during flexible ureteroscopy compared to 1.9 Fr. stone baskets. Urol Res 34:389–392PubMedCrossRef Nagele U, Horstmann M, Hennenlotter J, Walcher U, Kuczyk MA, Sievert KD, Stenzl A, Anastasiadis AG (2006) Size does matter: 1.5 Fr. stone baskets almost double irrigation flow during flexible ureteroscopy compared to 1.9 Fr. stone baskets. Urol Res 34:389–392PubMedCrossRef
7.
Zurück zum Zitat Smith RD, Patel A (2007) Impact of flexible ureterorenoscopy in current management of nephrolithiasis. Curr Opin Urol 17:114–119PubMedCrossRef Smith RD, Patel A (2007) Impact of flexible ureterorenoscopy in current management of nephrolithiasis. Curr Opin Urol 17:114–119PubMedCrossRef
8.
Zurück zum Zitat Turk C, Knoll T, Kohrmann KU (2008) New guidelines for urinary stone treatment: controversy or development? Urologe A 47:591–593PubMedCrossRef Turk C, Knoll T, Kohrmann KU (2008) New guidelines for urinary stone treatment: controversy or development? Urologe A 47:591–593PubMedCrossRef
Metadaten
Titel
Flow matters: irrigation flow differs in flexible ureteroscopes of the newest generation
verfasst von
Stephan Kruck
Aristoteles G. Anastasiadis
Georgios Gakis
Ute Walcher
Joerg Hennenlotter
Axel S. Merseburger
Arnulf Stenzl
Udo Nagele
Publikationsdatum
01.12.2011
Verlag
Springer-Verlag
Erschienen in
Urolithiasis / Ausgabe 6/2011
Print ISSN: 2194-7228
Elektronische ISSN: 2194-7236
DOI
https://doi.org/10.1007/s00240-011-0373-y

Weitere Artikel der Ausgabe 6/2011

Urolithiasis 6/2011 Zur Ausgabe

Update Urologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.