Skip to main content
Erschienen in: Acta Neurochirurgica 11/2014

01.11.2014 | Clinical Article - Vascular

Flow visualization of recurrent aneurysms after coil embolization by 3D phase-contrast MRI

verfasst von: Kenichi Kono, Tomoaki Terada

Erschienen in: Acta Neurochirurgica | Ausgabe 11/2014

Einloggen, um Zugang zu erhalten

Abstract

Background

Flow patterns in cerebral aneurysms are clinically important. Information on inflow patterns into aneurysms is especially helpful in preventing a recurrence after coil embolization. Computational fluid dynamics (CFD) simulations of patient-specific cerebral aneurysms are feasible and provide information on flow patterns. However, flow visualization by CFD simulations is challenging for recurrent aneurysms after coil embolization because coils make it difficult to obtain precise geometry of the recurrent aneurysms. In this study, we assessed the feasibility of flow visualization of recurrent aneurysms using 3D phase-contrast magnetic resonance imaging (PC-MRI).

Method

Time-of-flight magnetic resonance angiography and 3D PC-MRI were performed in eight cases of recurrent aneurysms after coil embolization. We attempted to visualize flow inside the aneurysms using data of 3D PC-MRI and evaluated the visualization. Additionally, CFD simulations were performed in a single case.

Results

Inflow into aneurysms was visualized in all eight cases (100 %). Flow patterns inside aneurysms were visualized in six cases (75 %), and these were associated with a large size of recurrent aneurysms (mean size, 10.3 mm for visualized cases vs. 4.8 mm for unvisualized cases; p = 0.046, Mann–Whitney test). Flow patterns were similar between PC-MRI and CFD simulations. PC-MRI was faster and easier for observing inflow patterns than CFD simulations.

Conclusions

This is the first study to demonstrate that flow visualization of recurrent aneurysms by 3D PC-MRI is feasible. This technique may be more practical and easier than CFD simulations, and may provide clinically helpful information.
Literatur
1.
Zurück zum Zitat Cebral JR, Mut F, Weir J, Putman CM (2011) Association of hemodynamic characteristics and cerebral aneurysm rupture. AJNR Am J Neuroradiol 32:264–270PubMedCrossRefPubMedCentral Cebral JR, Mut F, Weir J, Putman CM (2011) Association of hemodynamic characteristics and cerebral aneurysm rupture. AJNR Am J Neuroradiol 32:264–270PubMedCrossRefPubMedCentral
2.
Zurück zum Zitat Gao B, Baharoglu MI, Cohen AD, Malek AM (2012) Stent-assisted coiling of intracranial bifurcation aneurysms leads to immediate and delayed intracranial vascular angle remodeling. AJNR Am J Neuroradiol 33:649–654PubMedCrossRef Gao B, Baharoglu MI, Cohen AD, Malek AM (2012) Stent-assisted coiling of intracranial bifurcation aneurysms leads to immediate and delayed intracranial vascular angle remodeling. AJNR Am J Neuroradiol 33:649–654PubMedCrossRef
3.
Zurück zum Zitat Graves VB, Strother CM, Duff TA, Perl J (1995) Early treatment of ruptured aneurysms with Guglielmi detachable coils: effect on subsequent bleeding. Neurosurgery 37:640–647PubMedCrossRef Graves VB, Strother CM, Duff TA, Perl J (1995) Early treatment of ruptured aneurysms with Guglielmi detachable coils: effect on subsequent bleeding. Neurosurgery 37:640–647PubMedCrossRef
4.
Zurück zum Zitat Hoi Y, Woodward SH, Kim M, Taulbee DB, Meng H (2006) Validation of CFD simulations of cerebral aneurysms with implication of geometric variations. J Biomech Eng 128:844–851PubMedCrossRefPubMedCentral Hoi Y, Woodward SH, Kim M, Taulbee DB, Meng H (2006) Validation of CFD simulations of cerebral aneurysms with implication of geometric variations. J Biomech Eng 128:844–851PubMedCrossRefPubMedCentral
5.
Zurück zum Zitat Huang QH, Wu YF, Xu Y, Hong B, Zhang L, Liu JM (2011) Vascular geometry change because of endovascular stent placement for anterior communicating artery aneurysms. AJNR Am J Neuroradiol 32:1721–1725PubMedCrossRef Huang QH, Wu YF, Xu Y, Hong B, Zhang L, Liu JM (2011) Vascular geometry change because of endovascular stent placement for anterior communicating artery aneurysms. AJNR Am J Neuroradiol 32:1721–1725PubMedCrossRef
6.
Zurück zum Zitat Hyogo T, Kataoka T, Hayase K, Nakamura H (2001) Angiographical follow-up results of cerebral aneurysms treated by Guglielmi detachable coil system. Interv Neuroradiol 7:137–142PubMedPubMedCentral Hyogo T, Kataoka T, Hayase K, Nakamura H (2001) Angiographical follow-up results of cerebral aneurysms treated by Guglielmi detachable coil system. Interv Neuroradiol 7:137–142PubMedPubMedCentral
7.
Zurück zum Zitat Isoda H, Ohkura Y, Kosugi T, Hirano M, Alley MT, Bammer R, Pelc NJ, Namba H, Sakahara H (2010) Comparison of hemodynamics of intracranial aneurysms between MR fluid dynamics using 3D cine phase-contrast MRI and MR-based computational fluid dynamics. Neuroradiology 52:913–920PubMedCrossRefPubMedCentral Isoda H, Ohkura Y, Kosugi T, Hirano M, Alley MT, Bammer R, Pelc NJ, Namba H, Sakahara H (2010) Comparison of hemodynamics of intracranial aneurysms between MR fluid dynamics using 3D cine phase-contrast MRI and MR-based computational fluid dynamics. Neuroradiology 52:913–920PubMedCrossRefPubMedCentral
8.
Zurück zum Zitat Isoda H, Ohkura Y, Kosugi T, Hirano M, Takeda H, Hiramatsu H, Yamashita S, Takehara Y, Alley MT, Bammer R, Pelc NJ, Namba H, Sakahara H (2010) In vivo hemodynamic analysis of intracranial aneurysms obtained by magnetic resonance fluid dynamics (MRFD) based on time-resolved three-dimensional phase-contrast MRI. Neuroradiology 52:921–928PubMedCrossRef Isoda H, Ohkura Y, Kosugi T, Hirano M, Takeda H, Hiramatsu H, Yamashita S, Takehara Y, Alley MT, Bammer R, Pelc NJ, Namba H, Sakahara H (2010) In vivo hemodynamic analysis of intracranial aneurysms obtained by magnetic resonance fluid dynamics (MRFD) based on time-resolved three-dimensional phase-contrast MRI. Neuroradiology 52:921–928PubMedCrossRef
9.
Zurück zum Zitat Kono K, Fujimoto T, Shintani A, Terada T (2012) Hemodynamic characteristics at the rupture site of cerebral aneurysms: a case study. Neurosurgery 71:E1202–E1209PubMedCrossRef Kono K, Fujimoto T, Shintani A, Terada T (2012) Hemodynamic characteristics at the rupture site of cerebral aneurysms: a case study. Neurosurgery 71:E1202–E1209PubMedCrossRef
10.
Zurück zum Zitat Kono K, Shintani A, Fujimoto T, Terada T (2012) Stent-assisted coil embolization and computational fluid dynamics simulations of bilateral vertebral artery dissecting aneurysms presenting with subarachnoid hemorrhage: case report. Neurosurgery 71:E1192–E1201PubMedCrossRef Kono K, Shintani A, Fujimoto T, Terada T (2012) Stent-assisted coil embolization and computational fluid dynamics simulations of bilateral vertebral artery dissecting aneurysms presenting with subarachnoid hemorrhage: case report. Neurosurgery 71:E1192–E1201PubMedCrossRef
11.
Zurück zum Zitat Kono K, Shintani S, Terada T (2014) Retreatment of recanalized aneurysms after y-stent-assisted coil embolization with double enterprise stents: case report and systematic review of the literature. Turk Neurosurg 24:593–597PubMed Kono K, Shintani S, Terada T (2014) Retreatment of recanalized aneurysms after y-stent-assisted coil embolization with double enterprise stents: case report and systematic review of the literature. Turk Neurosurg 24:593–597PubMed
12.
Zurück zum Zitat Kono K, Terada T (2013) Hemodynamics of 8 different configurations of stenting for bifurcation aneurysms. AJNR Am J Neuroradiol 34:1980–1986PubMedCrossRef Kono K, Terada T (2013) Hemodynamics of 8 different configurations of stenting for bifurcation aneurysms. AJNR Am J Neuroradiol 34:1980–1986PubMedCrossRef
13.
Zurück zum Zitat Kono K, Tomura N, Yoshimura R, Terada T (2013) Changes in wall shear stress magnitude after aneurysm rupture. Acta Neurochir (Wien) 155:1559–1563CrossRef Kono K, Tomura N, Yoshimura R, Terada T (2013) Changes in wall shear stress magnitude after aneurysm rupture. Acta Neurochir (Wien) 155:1559–1563CrossRef
14.
Zurück zum Zitat Lorensen WE, Cline HE (1987) Marching cubes: a high resolution 3D surface construction algorithm. ACM Siggraph Comput Graph 21:163–169CrossRef Lorensen WE, Cline HE (1987) Marching cubes: a high resolution 3D surface construction algorithm. ACM Siggraph Comput Graph 21:163–169CrossRef
15.
Zurück zum Zitat Luo B, Yang X, Wang S, Li H, Chen J, Yu H, Zhang Y, Zhang Y, Mu S, Liu Z, Ding G (2011) High shear stress and flow velocity in partially occluded aneurysms prone to recanalization. Stroke 42:745–753PubMedCrossRef Luo B, Yang X, Wang S, Li H, Chen J, Yu H, Zhang Y, Zhang Y, Mu S, Liu Z, Ding G (2011) High shear stress and flow velocity in partially occluded aneurysms prone to recanalization. Stroke 42:745–753PubMedCrossRef
16.
Zurück zum Zitat Naito T, Miyachi S, Matsubara N, Isoda H, Izumi T, Haraguchi K, Takahashi I, Ishii K, Wakabayashi T (2012) Magnetic resonance fluid dynamics for intracranial aneurysms–comparison with computed fluid dynamics. Acta Neurochir (Wien) 154:993–1001CrossRef Naito T, Miyachi S, Matsubara N, Isoda H, Izumi T, Haraguchi K, Takahashi I, Ishii K, Wakabayashi T (2012) Magnetic resonance fluid dynamics for intracranial aneurysms–comparison with computed fluid dynamics. Acta Neurochir (Wien) 154:993–1001CrossRef
17.
Zurück zum Zitat Shimai H, Yokota H, Nakamura S, Himeno R (2005) Extraction from biological volume data of a region of interest with non-uniform intensity. Optomechatronic Techn 2005:605115 Shimai H, Yokota H, Nakamura S, Himeno R (2005) Extraction from biological volume data of a region of interest with non-uniform intensity. Optomechatronic Techn 2005:605115
18.
Zurück zum Zitat Steinman DA, Hoi Y, Fahy P, Morris L, Walsh MT, Aristokleous N, Anayiotos AS, Papaharilaou Y, Arzani A, Shadden SC, Berg P, Janiga G, Bols J, Segers P, Bressloff NW, Cibis M, Gijsen FH, Cito S, Pallarés J, Browne LD, Costelloe JA, Lynch AG, Degroote J, Vierendeels J, Fu W, Qiao A, Hodis S, Kallmes DF, Kalsi H, Long Q, Kheyfets VO, Finol EA, Kono K, Malek AM, Lauric A, Menon PG, Pekkan K, Esmaily Moghadam M, Marsden AL, Oshima M, Katagiri K, Peiffer V, Mohamied Y, Sherwin SJ, Schaller J, Goubergrits L, Usera G, Mendina M, Valen-Sendstad K, Habets DF, Xiang J, Meng H, Yu Y, Karniadakis GE, Shaffer N, Loth F (2013) Variability of computational fluid dynamics solutions for pressure and flow in a giant aneurysm: the ASME 2012 Summer Bioengineering Conference CFD Challenge. J Biomech Eng 135:021016PubMedCrossRef Steinman DA, Hoi Y, Fahy P, Morris L, Walsh MT, Aristokleous N, Anayiotos AS, Papaharilaou Y, Arzani A, Shadden SC, Berg P, Janiga G, Bols J, Segers P, Bressloff NW, Cibis M, Gijsen FH, Cito S, Pallarés J, Browne LD, Costelloe JA, Lynch AG, Degroote J, Vierendeels J, Fu W, Qiao A, Hodis S, Kallmes DF, Kalsi H, Long Q, Kheyfets VO, Finol EA, Kono K, Malek AM, Lauric A, Menon PG, Pekkan K, Esmaily Moghadam M, Marsden AL, Oshima M, Katagiri K, Peiffer V, Mohamied Y, Sherwin SJ, Schaller J, Goubergrits L, Usera G, Mendina M, Valen-Sendstad K, Habets DF, Xiang J, Meng H, Yu Y, Karniadakis GE, Shaffer N, Loth F (2013) Variability of computational fluid dynamics solutions for pressure and flow in a giant aneurysm: the ASME 2012 Summer Bioengineering Conference CFD Challenge. J Biomech Eng 135:021016PubMedCrossRef
19.
Zurück zum Zitat van Ooij P, Schneiders JJ, Marquering HA, Majoie CB, van Bavel E, Nederveen AJ (2013) 3D cine phase-contrast MRI at 3T in intracranial aneurysms compared with patient-specific computational fluid dynamics. AJNR Am J Neuroradiol 34:1785–1791PubMedCrossRef van Ooij P, Schneiders JJ, Marquering HA, Majoie CB, van Bavel E, Nederveen AJ (2013) 3D cine phase-contrast MRI at 3T in intracranial aneurysms compared with patient-specific computational fluid dynamics. AJNR Am J Neuroradiol 34:1785–1791PubMedCrossRef
Metadaten
Titel
Flow visualization of recurrent aneurysms after coil embolization by 3D phase-contrast MRI
verfasst von
Kenichi Kono
Tomoaki Terada
Publikationsdatum
01.11.2014
Verlag
Springer Vienna
Erschienen in
Acta Neurochirurgica / Ausgabe 11/2014
Print ISSN: 0001-6268
Elektronische ISSN: 0942-0940
DOI
https://doi.org/10.1007/s00701-014-2231-5

Weitere Artikel der Ausgabe 11/2014

Acta Neurochirurgica 11/2014 Zur Ausgabe

Experimental Research - Neurosurgical Techniques

Flow-regulated external lumbar drain: applications and complications

Leitlinien kompakt für die Neurologie

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Schützt Olivenöl vor dem Tod durch Demenz?

10.05.2024 Morbus Alzheimer Nachrichten

Konsumieren Menschen täglich 7 Gramm Olivenöl, ist ihr Risiko, an einer Demenz zu sterben, um mehr als ein Vierten reduziert – und dies weitgehend unabhängig von ihrer sonstigen Ernährung. Dafür sprechen Auswertungen zweier großer US-Studien.

Bluttest erkennt Parkinson schon zehn Jahre vor der Diagnose

10.05.2024 Parkinson-Krankheit Nachrichten

Ein Bluttest kann abnorm aggregiertes Alpha-Synuclein bei einigen Menschen schon zehn Jahre vor Beginn der motorischen Parkinsonsymptome nachweisen. Mit einem solchen Test lassen sich möglicherweise Prodromalstadien erfassen und die Betroffenen früher behandeln.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Wartezeit nicht kürzer, aber Arbeit flexibler

Psychotherapie Medizin aktuell

Fünf Jahren nach der Neugestaltung der Psychotherapie-Richtlinie wurden jetzt die Effekte der vorgenommenen Änderungen ausgewertet. Das Hauptziel der Novellierung war eine kürzere Wartezeit auf Therapieplätze. Dieses Ziel wurde nicht erreicht, es gab jedoch positive Auswirkungen auf andere Bereiche.

Update Neurologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.