Skip to main content
Erschienen in: Clinical Oral Investigations 4/2009

01.12.2009 | Original Article

Fracture characteristics of anterior resin-bonded zirconia-fixed partial dentures

verfasst von: Martin Rosentritt, Stefan Ries, Carola Kolbeck, Maria Westphal, Ernst-Jürgen Richter, Gerhard Handel

Erschienen in: Clinical Oral Investigations | Ausgabe 4/2009

Einloggen, um Zugang zu erhalten

Abstract

Resin-bonded fixed partial dentures (RBFPD) are used as a minimal invasive, tooth-preventing alternative for replacing anterior teeth. Zirconia cantilever restorations were supposed to show sufficient strength for a clinical application. The aim of this investigation was to determine the fracture characteristics of cantilever and two-retainer RBFPD, which are fabricated by computer-manufactured high-strength zirconia. Human incisors and canines were used to form three groups of 14 RBFPDs with different types of preparation: group 1, an invasive cantilever; group 2, a minimal-invasive cantilever and group 3, a two-retainer RBFPD control. After thermal cycling and mechanical loading, which was performed to simulate oral service, all restorations were loaded to fracture in a universal testing machine. One half of the specimens were investigated as a control without simulated service. Mode of failure was determined for the three designs. Both cantilever groups showed comparable fracture resistance of 227 N (no. 1) and 210 N (no. 2) before thermal cycling and mechanical loading. The resistance after aging was reduced to 210 N for the invasive cantilever RBFPD and to 179 N for the minimal invasive group. Three-unit RBFPDs showed a significantly higher (p < 0.02) fracture resistance than cantilever bridges before (426 N) as well as after aging (360 N). Predominant failure was FPD and retainer fracture for the invasive cantilever design, debonding for the minimal cantilever design and RBFPD fracture for the two-retainer design. The present study revealed a significantly higher fracture resistance for two-retainer RBFPDs than for cantilever RBFPDs. The frequency of adhesive debonding increased for non-retentive prepared cantilever RBFPDs.
Literatur
1.
Zurück zum Zitat Edelhoff D, Sorensen JA (2002) Tooth removal associated with various preparation designs for anterior teeth. J Prosthet Dent 87:503–509CrossRefPubMed Edelhoff D, Sorensen JA (2002) Tooth removal associated with various preparation designs for anterior teeth. J Prosthet Dent 87:503–509CrossRefPubMed
2.
Zurück zum Zitat Behr M, Leibrock A, Stich W, Rammelsberg P, Rosentritt M, Handel G (1998) Adhesive-fixed partial dentures in anterior and posterior areas. Results of an on-going prospective study begun in 1985. Clin Oral Invest 2:31–35CrossRef Behr M, Leibrock A, Stich W, Rammelsberg P, Rosentritt M, Handel G (1998) Adhesive-fixed partial dentures in anterior and posterior areas. Results of an on-going prospective study begun in 1985. Clin Oral Invest 2:31–35CrossRef
3.
Zurück zum Zitat Probster B, Henrich GM (1997) 11-year follow-up study of resin-bonded fixed partial dentures. Int J Prosthodont 10:259–268PubMed Probster B, Henrich GM (1997) 11-year follow-up study of resin-bonded fixed partial dentures. Int J Prosthodont 10:259–268PubMed
4.
Zurück zum Zitat De Backer H, Van Herle G, De Moor N, Van den Berghe L, De Boever J (2006) A 20-year retrospective survival study of fixed partial dentures. Int J Prosthodont 19:143–153PubMed De Backer H, Van Herle G, De Moor N, Van den Berghe L, De Boever J (2006) A 20-year retrospective survival study of fixed partial dentures. Int J Prosthodont 19:143–153PubMed
5.
Zurück zum Zitat Ketabi AR, Kaus T, Herdach F, Groten M, Axmann-Krcmar D, Pröbster L et al (2004) Thirteen-year follow-up study of resin-bonded fixed partial dentures. Quint Inter 35:407–410 Ketabi AR, Kaus T, Herdach F, Groten M, Axmann-Krcmar D, Pröbster L et al (2004) Thirteen-year follow-up study of resin-bonded fixed partial dentures. Quint Inter 35:407–410
6.
Zurück zum Zitat Wolfart S, Kern M (2006) A new design for all-ceramic inlay-retained fixed partial dentures: a report of 2 cases. Quintessence Inter 37:27–33 Wolfart S, Kern M (2006) A new design for all-ceramic inlay-retained fixed partial dentures: a report of 2 cases. Quintessence Inter 37:27–33
7.
Zurück zum Zitat Kern M, Glaser R (1997) Cantilevered all-ceramic, resin-bonded fixed partial dentures: a new treatment modality. J Esthet Dent 9:255–264CrossRefPubMed Kern M, Glaser R (1997) Cantilevered all-ceramic, resin-bonded fixed partial dentures: a new treatment modality. J Esthet Dent 9:255–264CrossRefPubMed
8.
Zurück zum Zitat Komine F, Tomic M (2005) A single-retainer zirconium dioxide ceramic resin-bonded fixed partial denture for single tooth replacement: a clinical report. J Oral Sci 47:139–142CrossRefPubMed Komine F, Tomic M (2005) A single-retainer zirconium dioxide ceramic resin-bonded fixed partial denture for single tooth replacement: a clinical report. J Oral Sci 47:139–142CrossRefPubMed
9.
Zurück zum Zitat Ries S, Wolz J, Richter EJ (2006) Effect of design of all-ceramic resin-bonded fixed partial dentures on clinical survival rate. Int J Periodontics Restor Dent 26:143–149 Ries S, Wolz J, Richter EJ (2006) Effect of design of all-ceramic resin-bonded fixed partial dentures on clinical survival rate. Int J Periodontics Restor Dent 26:143–149
10.
Zurück zum Zitat Rosentritt M, Kolbeck C, Ries S, Gross M, Behr M, Handel G (2008) Zirconia resin-bonded fixed partial dentures in the anterior maxilla. Quintessence Int 39:313–319PubMed Rosentritt M, Kolbeck C, Ries S, Gross M, Behr M, Handel G (2008) Zirconia resin-bonded fixed partial dentures in the anterior maxilla. Quintessence Int 39:313–319PubMed
11.
Zurück zum Zitat Koutayas SO, Kern M, Ferraresso F, Stub JR (2000) Influence of design and mode of loading on the fracture strength of allceramic resin-bonded fixed partial dentures: An in vitro study in a dual-axis chewing simulator. J Prosthet Dent 83:540–547CrossRefPubMed Koutayas SO, Kern M, Ferraresso F, Stub JR (2000) Influence of design and mode of loading on the fracture strength of allceramic resin-bonded fixed partial dentures: An in vitro study in a dual-axis chewing simulator. J Prosthet Dent 83:540–547CrossRefPubMed
12.
Zurück zum Zitat Kern M (2005) Clinical long-term survival of two-retainer and single-retainer all-ceramic resin-bonded fixed partial dentures. Quintessence Int 36:141–147PubMed Kern M (2005) Clinical long-term survival of two-retainer and single-retainer all-ceramic resin-bonded fixed partial dentures. Quintessence Int 36:141–147PubMed
13.
Zurück zum Zitat Botelho MG, Chan AW, Yiu EY, Tse ET (2002) Longevity of two-unit cantilevered resin-bonded fixed partial dentures. Am J Dent 15:295–299PubMed Botelho MG, Chan AW, Yiu EY, Tse ET (2002) Longevity of two-unit cantilevered resin-bonded fixed partial dentures. Am J Dent 15:295–299PubMed
14.
Zurück zum Zitat Botelho MG, Leung KC, Ng H, Chan K (2006) A retrospective clinical evaluation of two-unit cantilevered resin-bonded fixed partial dentures. J Am Dent Assoc 137:783–788PubMed Botelho MG, Leung KC, Ng H, Chan K (2006) A retrospective clinical evaluation of two-unit cantilevered resin-bonded fixed partial dentures. J Am Dent Assoc 137:783–788PubMed
15.
Zurück zum Zitat Behr M, Hindelang U, Rosentritt M, Lang R Handel G (2000) Comparison of failure rates of adhesive-fixed partial dentures for in vivo and in vitro studies. Clin Oral Investig 4:25–30CrossRefPubMed Behr M, Hindelang U, Rosentritt M, Lang R Handel G (2000) Comparison of failure rates of adhesive-fixed partial dentures for in vivo and in vitro studies. Clin Oral Investig 4:25–30CrossRefPubMed
16.
Zurück zum Zitat Creugers NH, Snoek PA, Van , t Hof MA, Kayser AF (1990) Clinical performance of resin-bonded bridges: a 5-year prospective study. Part III: failure characteristics and survival after rebonding. J Oral Rehabil 17:179–186CrossRefPubMed Creugers NH, Snoek PA, Van , t Hof MA, Kayser AF (1990) Clinical performance of resin-bonded bridges: a 5-year prospective study. Part III: failure characteristics and survival after rebonding. J Oral Rehabil 17:179–186CrossRefPubMed
17.
Zurück zum Zitat Koutayas SO, Kern M, Ferraresso F, Strub JR (2002) Influence of framework design on fracture strength of mandibular anterior all-ceramic resin-bonded fixed partial dentures. Int J Prosthodont 15:223–229PubMed Koutayas SO, Kern M, Ferraresso F, Strub JR (2002) Influence of framework design on fracture strength of mandibular anterior all-ceramic resin-bonded fixed partial dentures. Int J Prosthodont 15:223–229PubMed
18.
Zurück zum Zitat Helkimo E, Carlsson GE, Helkimo M (1997) Bite force and state of dentition. Acta Odontol Scand 35:297–303CrossRef Helkimo E, Carlsson GE, Helkimo M (1997) Bite force and state of dentition. Acta Odontol Scand 35:297–303CrossRef
19.
Zurück zum Zitat Waltimo A, Kononen M (1995) Maximal bite force and its association with signs and symptoms of craniomandibular disorders in young Finnish non-patients. Acta Odontol Scand 53:254–258CrossRefPubMed Waltimo A, Kononen M (1995) Maximal bite force and its association with signs and symptoms of craniomandibular disorders in young Finnish non-patients. Acta Odontol Scand 53:254–258CrossRefPubMed
20.
Zurück zum Zitat Waltimo A, Kononen M (1993) A novel bite force recorder and maximal isometric bite force values for healthy young adults. Scand J Dent Res 101:171–175PubMed Waltimo A, Kononen M (1993) A novel bite force recorder and maximal isometric bite force values for healthy young adults. Scand J Dent Res 101:171–175PubMed
21.
Zurück zum Zitat Paphangkorakit J, Osborn JW (2000) The effect of normal occlusal forces on fluid movement through human dentine in vitro. Arch Oral Biol 45:1033–1041CrossRefPubMed Paphangkorakit J, Osborn JW (2000) The effect of normal occlusal forces on fluid movement through human dentine in vitro. Arch Oral Biol 45:1033–1041CrossRefPubMed
22.
Zurück zum Zitat Uo M, Sjogren G, Sundh A, Watari F, Bergman M, Lerner U (2003) Cytotoxicity and bonding property of dental ceramics. Dent Mater 19:487–492CrossRefPubMed Uo M, Sjogren G, Sundh A, Watari F, Bergman M, Lerner U (2003) Cytotoxicity and bonding property of dental ceramics. Dent Mater 19:487–492CrossRefPubMed
23.
Zurück zum Zitat Ernst CP, Cohnen U, Stender E, Willershausen B (2005) In vitro retentive strength of zirconium oxide ceramic crowns using different luting agents. J Prosthet Dent 93:551–558CrossRefPubMed Ernst CP, Cohnen U, Stender E, Willershausen B (2005) In vitro retentive strength of zirconium oxide ceramic crowns using different luting agents. J Prosthet Dent 93:551–558CrossRefPubMed
24.
Zurück zum Zitat Atsu SS, Kilicarslan MA, Kucukesmen HC, Aka PS (2006) Effect of zirconium-oxide ceramic surface treatments on the bond strength to adhesive resin. J Prosthet Dent 95:430–436CrossRefPubMed Atsu SS, Kilicarslan MA, Kucukesmen HC, Aka PS (2006) Effect of zirconium-oxide ceramic surface treatments on the bond strength to adhesive resin. J Prosthet Dent 95:430–436CrossRefPubMed
25.
Zurück zum Zitat Wegner SM, gerdes W, Kern M (2002) Effect of different aging conditions on ceramic-composite bond strength. Int J Prosthodont 15:267–272PubMed Wegner SM, gerdes W, Kern M (2002) Effect of different aging conditions on ceramic-composite bond strength. Int J Prosthodont 15:267–272PubMed
26.
Zurück zum Zitat Wegner SM, Kern M (2000) Long-term resin bond strength to zirconia ceramic. J Adhes Dent 2:139–147PubMed Wegner SM, Kern M (2000) Long-term resin bond strength to zirconia ceramic. J Adhes Dent 2:139–147PubMed
27.
Zurück zum Zitat Loher H, Behr M, Hintereder U, Rosentritt M, Handel G (2009) The impact of cement mixing and storage errors on the risk of failure of glass-ceramic crowns. Clin Oral Investig. doi:10.1007/s00784-008-0215-7 Loher H, Behr M, Hintereder U, Rosentritt M, Handel G (2009) The impact of cement mixing and storage errors on the risk of failure of glass-ceramic crowns. Clin Oral Investig. doi:10.​1007/​s00784-008-0215-7
28.
Zurück zum Zitat Caughman WF, Chan DC, Rueggeberg FA (2001) Curing potential of dual-polymerizable resin cements in simulated clinical situations. J Prosthet Dent 85:479–484CrossRefPubMed Caughman WF, Chan DC, Rueggeberg FA (2001) Curing potential of dual-polymerizable resin cements in simulated clinical situations. J Prosthet Dent 85:479–484CrossRefPubMed
29.
Zurück zum Zitat Walker MP, Spencer P, Eick JD (2003) Effect of simulated resin-bonded fixed partial denture clinical conditions on resin cement mechanical properties. J Oral Rehabil 30:837–846CrossRefPubMed Walker MP, Spencer P, Eick JD (2003) Effect of simulated resin-bonded fixed partial denture clinical conditions on resin cement mechanical properties. J Oral Rehabil 30:837–846CrossRefPubMed
30.
Zurück zum Zitat Beuer F, Naumann M, Gernet W Sorensen JA (2009) Precision of fit: zirconia three-unit fixed dental prostheses. Clin Oral Investig. doi:10.1007/s00784-008-0224-6. PNID: 18769946 Beuer F, Naumann M, Gernet W Sorensen JA (2009) Precision of fit: zirconia three-unit fixed dental prostheses. Clin Oral Investig. doi:10.​1007/​s00784-008-0224-6. PNID: 18769946
31.
Zurück zum Zitat De Jager N, Pallav P, Feilzer AJ (2004) The apparent increase of the Young’s modulus in thin cement layers. Dent Mater 20:457–462CrossRefPubMed De Jager N, Pallav P, Feilzer AJ (2004) The apparent increase of the Young’s modulus in thin cement layers. Dent Mater 20:457–462CrossRefPubMed
32.
Zurück zum Zitat Wolfart M, Lehmann F, Wolfart S, Kern M (2007) Durability of resin bond strength to zirconia ceramic after using different surface conditioning methods. Dent Mater 23:45–50CrossRefPubMed Wolfart M, Lehmann F, Wolfart S, Kern M (2007) Durability of resin bond strength to zirconia ceramic after using different surface conditioning methods. Dent Mater 23:45–50CrossRefPubMed
33.
Zurück zum Zitat Yoshida K, Tsuo Y, Atsuta M (2006) Bonding of dual-cured resin cement to zirconia ceramic using phosphate acid ester monomer and zirconate coupler. J Biomed Mater Res. Part B. Appl Biomater 77:28–33PubMedCrossRef Yoshida K, Tsuo Y, Atsuta M (2006) Bonding of dual-cured resin cement to zirconia ceramic using phosphate acid ester monomer and zirconate coupler. J Biomed Mater Res. Part B. Appl Biomater 77:28–33PubMedCrossRef
34.
Zurück zum Zitat Nothdurft FP, Motter PJ, Pospiech PR (2009) Effect of surface treatment on the initial bond strength of different luting cements to zirconium oxide ceramic. Clin Oral Investig. doi:10.1007/s00784-008-0222-8. PMID: 18758827 Nothdurft FP, Motter PJ, Pospiech PR (2009) Effect of surface treatment on the initial bond strength of different luting cements to zirconium oxide ceramic. Clin Oral Investig. doi:10.​1007/​s00784-008-0222-8. PMID: 18758827
35.
Zurück zum Zitat Ozcan M, Kerkdijk S, Valandro LF (2008) Comparison of resin cement adhesion to Y-TZP ceramic following manufacturers’ instructions of the cements only. Clin Oral Investig 12:279–282CrossRefPubMed Ozcan M, Kerkdijk S, Valandro LF (2008) Comparison of resin cement adhesion to Y-TZP ceramic following manufacturers’ instructions of the cements only. Clin Oral Investig 12:279–282CrossRefPubMed
36.
Zurück zum Zitat Johnston CD, Hussey DL (1993) The immediate replacement of incisor teeth by cantilevered resin-bonded bridgework. Dent Up 22:190–196 Johnston CD, Hussey DL (1993) The immediate replacement of incisor teeth by cantilevered resin-bonded bridgework. Dent Up 22:190–196
37.
Zurück zum Zitat Briggs P (1996) The single unit, single retainer, cantilever resin-bonded bridge. Br Dent J 181:373–377PubMed Briggs P (1996) The single unit, single retainer, cantilever resin-bonded bridge. Br Dent J 181:373–377PubMed
38.
Zurück zum Zitat Hussey DL (1996) The clinical performance of cantilevered resin-bonded bridgework. J Dent 24:251–256CrossRefPubMed Hussey DL (1996) The clinical performance of cantilevered resin-bonded bridgework. J Dent 24:251–256CrossRefPubMed
39.
Zurück zum Zitat Chan AW, Barnes IE (2000) A prospective study of cantilever resin-bonded bridges: an initial report. Aust Dent J 45:31–36CrossRefPubMed Chan AW, Barnes IE (2000) A prospective study of cantilever resin-bonded bridges: an initial report. Aust Dent J 45:31–36CrossRefPubMed
40.
Zurück zum Zitat De Boever JA, McCall WD Jr, Holden S, Ash MM Jr (1978) Functional occlusal forces: an investigation by telemetry. J Prosthet Dent 40:326–333CrossRefPubMed De Boever JA, McCall WD Jr, Holden S, Ash MM Jr (1978) Functional occlusal forces: an investigation by telemetry. J Prosthet Dent 40:326–333CrossRefPubMed
Metadaten
Titel
Fracture characteristics of anterior resin-bonded zirconia-fixed partial dentures
verfasst von
Martin Rosentritt
Stefan Ries
Carola Kolbeck
Maria Westphal
Ernst-Jürgen Richter
Gerhard Handel
Publikationsdatum
01.12.2009
Verlag
Springer-Verlag
Erschienen in
Clinical Oral Investigations / Ausgabe 4/2009
Print ISSN: 1432-6981
Elektronische ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-009-0254-8

Weitere Artikel der Ausgabe 4/2009

Clinical Oral Investigations 4/2009 Zur Ausgabe

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Parodontalbehandlung verbessert Prognose bei Katheterablation

19.04.2024 Vorhofflimmern Nachrichten

Werden Personen mit Vorhofflimmern in der Blanking-Periode nach einer Katheterablation gegen eine bestehende Parodontitis behandelt, verbessert dies die Erfolgsaussichten. Dafür sprechen die Resultate einer prospektiven Untersuchung.

Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.