Erschienen in:
01.04.2016 | Research Article
Free phenytoin assessment in patients: measured versus calculated blood serum levels
verfasst von:
Andrea Tobler, Raphael Hösli, Stefan Mühlebach, Andreas Huber
Erschienen in:
International Journal of Clinical Pharmacy
|
Ausgabe 2/2016
Einloggen, um Zugang zu erhalten
Abstract
Background Total serum drug levels are routinely determined for the therapeutic drug monitoring of selected, difficult-to-dose drugs. For some of these drugs, however, knowledge of the free fraction is necessary to adapt correct dosing. Phenytoin, with its non-linear pharmacokinetics, >90 % albumin binding and slow elimination rate, is such a drug requiring individualization in patients, especially if rapid intravenous loading and subsequent dose adaptation is needed. In a prior long-term investigation, we showed the excellent performance of pharmacy-assisted Bayesian forecasting support for optimal dosing in hospitalized patients treated with phenytoin. In a subgroup analysis, we evaluated the suitability of the Sheiner-Tozer algorithm to calculate the free phenytoin fraction in hypoalbuminemic patients. Objective To test the usefulness of the Sheiner-Tozer algorithm for the correct estimation of the free phenytoin concentrations in hospitalized patients. Setting A Swiss tertiary care hospital. Method Free phenytoin plasma concentration was calculated from total phenytoin concentration in hypoalbuminemic patients and compared with the measured free phenytoin. The patients were separated into a low (35 ≤ albumin ≥ 25 g/L) and a very low group (albumin <25 g/L) for comparing and statistically analyzing the calculated and the measured free phenytoin concentration. Main outcome measures Calculated and the measured free phenytoin concentration. Results The calculated (1.2 mg/L (SD = 0.7) and the measured (1.1 mg/L (SD = 0.5) free phenytoin concentration correlated. The mean difference in the low and the very low albumin group was: 0.10 mg/L (SD = 1.4) (n = 11) and 0.13 mg/L (SD = 0.24) (n = 12), respectively. Although the variability of the data could be a bias, no statistically significant difference between the groups was found: t test (p = 0.78), the Passing–Bablok regression, the Spearman’s rank correlation coefficient of r = 0.907 and p = 0.00. The Bland–Altman plot including the regression analysis revealed no systematic differences between the calculated and the measured value [M = 0.11 (SD = 0.28)]. Conclusion In absence of a free phenytoin plasma concentration measurement also in hypoalbuminemic patients, the Sheiner-Tozer algorithm represents a useful tool to assist therapeutic monitoring to calculate or control free phenytoin by using total phenytoin and the albumin concentration.