Abstract

Purpose

Many image-guided interventions rely on tracked ultrasound where the transducer is augmented with a tracking device. The relationship between the ultrasound image coordinate system and the tracking sensor must be determined accurately via probe calibration. We introduce a novel calibration framework guided by the prediction of target registration error (TRE): Between successive measurements of the calibration phantom, our framework guides the user in choosing the pose of the calibration phantom by optimizing TRE.

Methods

We introduced an oriented line calibration phantom and modeled the ultrasound calibration process as a point-to-line registration problem. We then derived a spatial stiffness model of point-to-line registration for estimating TRE magnitude at any target. Assuming isotropic, identical localization error, we used the model to estimate TRE for each pixel using the current calibration estimate. We then searched through the calibration tool space to find the pose for the next fiducial which maximally minimized TRE.

Results

Both simulation and experimental results suggested that TRE decreases monotonically, reaching an asymptote when a sufficient number of measurements (typically around 12) are made. Independent point reconstruction accuracy assessment showed sub-millimeter accuracy of the calibration framework.

Conclusion

We have introduced the first TRE-guided ultrasound calibration framework. Using a hollow straw as an oriented line phantom, we virtually constructed a rigid lines phantom and modeled the calibration process as a point-to-line registration. Highly accurate calibration was achieved with minimal measurements by using a spatial stiffness model of TRE to strategically choose the pose of the calibration phantom between successive measurements.
Literatur
1.
Zurück zum Zitat Ackerman M, Cheng A, Boctor E, Chirikjian G (2014) Online ultrasound sensor calibration using gradient descent on the Euclidean group. In: Robotics and automation (ICRA), 2014 IEEE international conference on, pp 4900–4905 Ackerman M, Cheng A, Boctor E, Chirikjian G (2014) Online ultrasound sensor calibration using gradient descent on the Euclidean group. In: Robotics and automation (ICRA), 2014 IEEE international conference on, pp 4900–4905
2.
Zurück zum Zitat Ameri G, McLeod AJ, Baxter JSH, Chen ECS, Peters TM (2015) Line fiducial material and thickness considerations for ultrasound calibration. In: Proceedings of the SPIE, vol 9415 Ameri G, McLeod AJ, Baxter JSH, Chen ECS, Peters TM (2015) Line fiducial material and thickness considerations for ultrasound calibration. In: Proceedings of the SPIE, vol 9415
3.
Zurück zum Zitat Besl P, McKay ND (1992) A method for registration of 3-D shapes. Pattern analysis and machine intelligence. IEEE Trans 14(2):239–256 Besl P, McKay ND (1992) A method for registration of 3-D shapes. Pattern analysis and machine intelligence. IEEE Trans 14(2):239–256
4.
Zurück zum Zitat Chen EC, McLeod AJ, Baxter JS, Peters TM (2015) An iterative closest point framework for ultrasound calibration. In: Augmented environments for computer-assisted interventions, vol 9365, Springer International Publishing, pp 69–79 Chen EC, McLeod AJ, Baxter JS, Peters TM (2015) An iterative closest point framework for ultrasound calibration. In: Augmented environments for computer-assisted interventions, vol 9365, Springer International Publishing, pp 69–79
5.
Zurück zum Zitat Chen EC, McLeod AJ, Baxter JS, Peters TM (2015) Registration of 3D shapes under anisotropic scaling. Int J Comput Assist Radiol Surg 10(6):867–878CrossRefPubMed Chen EC, McLeod AJ, Baxter JS, Peters TM (2015) Registration of 3D shapes under anisotropic scaling. Int J Comput Assist Radiol Surg 10(6):867–878CrossRefPubMed
6.
Zurück zum Zitat Chen TK, Thurston AD, Ellis RE, Abolmaesumi P (2009) A real-time freehand ultrasound calibration system with automatic accuracy feedback and control. Ultrasound Med Biol 35(1):79–93CrossRefPubMed Chen TK, Thurston AD, Ellis RE, Abolmaesumi P (2009) A real-time freehand ultrasound calibration system with automatic accuracy feedback and control. Ultrasound Med Biol 35(1):79–93CrossRefPubMed
7.
Zurück zum Zitat Comeau RM, Fenster A, Peters TM (1998) Integrated MR and ultrasound imaging for improved image guidance in neurosurgery. In: Proceedings of the SPIE, vol 3338, pp 747–754 Comeau RM, Fenster A, Peters TM (1998) Integrated MR and ultrasound imaging for improved image guidance in neurosurgery. In: Proceedings of the SPIE, vol 3338, pp 747–754
8.
Zurück zum Zitat Detmer PR, Bashein G, Hodges T, Beach KW, Filer EP, Burns DH, Strandness DE Jr (1994) 3D ultrasonic image feature localization based on magnetic scanhead tracking: in vitro calibration and validation. Ultrasound Med Biol 20:923–936CrossRefPubMed Detmer PR, Bashein G, Hodges T, Beach KW, Filer EP, Burns DH, Strandness DE Jr (1994) 3D ultrasonic image feature localization based on magnetic scanhead tracking: in vitro calibration and validation. Ultrasound Med Biol 20:923–936CrossRefPubMed
9.
Zurück zum Zitat Fitzpatrick J, West J, Jr Maurer CR (1998) Predicting error in rigid-body point-based registration. Med Imaging IEEE Trans 17(5):694–702CrossRef Fitzpatrick J, West J, Jr Maurer CR (1998) Predicting error in rigid-body point-based registration. Med Imaging IEEE Trans 17(5):694–702CrossRef
10.
Zurück zum Zitat Gower JC, Dijksterhuis GB (2004) Procrustes problems. Oxford University Press, OxfordCrossRef Gower JC, Dijksterhuis GB (2004) Procrustes problems. Oxford University Press, OxfordCrossRef
11.
Zurück zum Zitat Guo X, Cheng A, Zhang H, Kang HJ, Etienne-Cummings R, Boctor E (2014) Active echo: A new paradigm for ultrasound calibration. In: Medical image computing and computer-assisted intervention, Springer, pp 397–404 Guo X, Cheng A, Zhang H, Kang HJ, Etienne-Cummings R, Boctor E (2014) Active echo: A new paradigm for ultrasound calibration. In: Medical image computing and computer-assisted intervention, Springer, pp 397–404
12.
Zurück zum Zitat Horn BK (1987) Closed-form solution of absolute orientation using unit quaternions. J Opt Soc Am 4:629–642CrossRef Horn BK (1987) Closed-form solution of absolute orientation using unit quaternions. J Opt Soc Am 4:629–642CrossRef
13.
Zurück zum Zitat Hsu PW, Prager RW, Gee AH, Treece GM (2009) Freehand 3D ultrasound calibration: a review. In: Advanced imaging in biology and medicine, Springer, Berlin, pp 47–84 Hsu PW, Prager RW, Gee AH, Treece GM (2009) Freehand 3D ultrasound calibration: a review. In: Advanced imaging in biology and medicine, Springer, Berlin, pp 47–84
14.
Zurück zum Zitat Hsu PW, Treece GM, Prager RW, Houghton NE, Gee AH (2008) Comparison of freehand 3-D ultrasound calibration techniques using a stylus. Ultrasound Med Biol 34(10):1610–1621CrossRefPubMed Hsu PW, Treece GM, Prager RW, Houghton NE, Gee AH (2008) Comparison of freehand 3-D ultrasound calibration techniques using a stylus. Ultrasound Med Biol 34(10):1610–1621CrossRefPubMed
15.
Zurück zum Zitat Khamene A, Sauer F (2005) A novel phantom-less spatial and temporal ultrasound calibration method. In: Medical image computing and computer-assisted intervention, Springer, pp 65–72 Khamene A, Sauer F (2005) A novel phantom-less spatial and temporal ultrasound calibration method. In: Medical image computing and computer-assisted intervention, Springer, pp 65–72
16.
Zurück zum Zitat Ma B, Ellis RE (2003) Robust registration for computer-integrated orthopedic surgery: laboratory validation and clinical experience. Med Image Anal 7(3):237–250CrossRefPubMed Ma B, Ellis RE (2003) Robust registration for computer-integrated orthopedic surgery: laboratory validation and clinical experience. Med Image Anal 7(3):237–250CrossRefPubMed
17.
Zurück zum Zitat Ma B, Ellis RE (2004) Spatial-stiffness analysis of surface-based registration. In: Medical image computing and computer-assisted intervention, Springer, pp 623–630 Ma B, Ellis RE (2004) Spatial-stiffness analysis of surface-based registration. In: Medical image computing and computer-assisted intervention, Springer, pp 623–630
18.
Zurück zum Zitat Ma B, Moghari M, Ellis R, Abolmaesumi P (2010) Estimation of optimal fiducial target registration error in the presence of heteroscedastic noise. Med Imaging IEEE Trans 29(3):708–723CrossRef Ma B, Moghari M, Ellis R, Abolmaesumi P (2010) Estimation of optimal fiducial target registration error in the presence of heteroscedastic noise. Med Imaging IEEE Trans 29(3):708–723CrossRef
19.
Zurück zum Zitat Ma B, Peters TM, Chen ECS (2016) Estimation of line-based target registration error. Proc SPIE 9786:978626-1–978626-9 Ma B, Peters TM, Chen ECS (2016) Estimation of line-based target registration error. Proc SPIE 9786:978626-1–978626-9
20.
Zurück zum Zitat Mercier L, Langø T, Lindseth F, Collins LD (2005) A review of calibration techniques for freehand 3-D ultrasound systems. Ultrasound Med Biol 31(2):143–165CrossRefPubMed Mercier L, Langø T, Lindseth F, Collins LD (2005) A review of calibration techniques for freehand 3-D ultrasound systems. Ultrasound Med Biol 31(2):143–165CrossRefPubMed
21.
Zurück zum Zitat Muratore DM, Galloway RL Jr (2001) Beam calibration without a phantom for creating a 3-D freehand ultrasound system. Ultrasound Med Biol 27(11):1557–1566CrossRefPubMed Muratore DM, Galloway RL Jr (2001) Beam calibration without a phantom for creating a 3-D freehand ultrasound system. Ultrasound Med Biol 27(11):1557–1566CrossRefPubMed
22.
Zurück zum Zitat Prager RW, Rohling RN, Gee AH, Berman L (1998) Rapid calibration for 3-D freehand ultrasound. Ultrasound Med Biol 24(6):855–869CrossRefPubMed Prager RW, Rohling RN, Gee AH, Berman L (1998) Rapid calibration for 3-D freehand ultrasound. Ultrasound Med Biol 24(6):855–869CrossRefPubMed
23.
Zurück zum Zitat Schönemann PH (1966) A generalized solution of the orthogonal procrustes problem. Psychometrika 31(1):1–10CrossRef Schönemann PH (1966) A generalized solution of the orthogonal procrustes problem. Psychometrika 31(1):1–10CrossRef
24.
Zurück zum Zitat Welch J, Bax M, Mori K, Krummel T, Shahidi R, Maurer C (2002) A fast and accurate method of ultrasound probe calibration for image-guided surgery. In: Proceedings of computer assisted radiology and surgery, p 1078 Welch J, Bax M, Mori K, Krummel T, Shahidi R, Maurer C (2002) A fast and accurate method of ultrasound probe calibration for image-guided surgery. In: Proceedings of computer assisted radiology and surgery, p 1078
25.
Zurück zum Zitat Yaniv Z (2015) Which pivot calibration? In: Proceedings of the SPIE, vol 9415 Yaniv Z (2015) Which pivot calibration? In: Proceedings of the SPIE, vol 9415
Metadaten
Titel
Guided ultrasound calibration: where, how, and how many calibration fiducials
verfasst von
Elvis C. S. Chen
Terry M. Peters
Burton Ma
Publikationsdatum
01.06.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
International Journal of Computer Assisted Radiology and Surgery / Ausgabe 6/2016
Print ISSN: 1861-6410
Elektronische ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-016-1390-7

Weitere Artikel der Ausgabe 6/2016

International Journal of Computer Assisted Radiology and Surgery 6/2016 Zur Ausgabe

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.