Skip to main content
Erschienen in: Acta Neurochirurgica 4/2016

01.04.2016 | Clinical Article - Vascular

Hemodynamic alterations after stent implantation in 15 cases of intracranial aneurysm

verfasst von: Chao Wang, Zhongbin Tian, Jian Liu, Linkai Jing, Nikhil Paliwal, Shengzhang Wang, Ying Zhang, Jianping Xiang, Adnan H. Siddiqui, Hui Meng, Xinjian Yang

Erschienen in: Acta Neurochirurgica | Ausgabe 4/2016

Einloggen, um Zugang zu erhalten

Abstract

Background

Stent-assisted coiling technology has been widely used in the treatment of intracranial aneurysms. In the current study, we investigated the intra-aneurysmal hemodynamic alterations after stent implantation and their association with the aneurysm location.

Methods

We first retrospectively studied 15 aneurysm cases [8 internal carotid artery-ophthalmic artery (ICA-OphA) aneurysms and 7 posterior communicating artery (PcoA) aneurysms] treated with Enterprise stents and coils. Then, based on the patient-specific geometries before and after stenting, we built virtual stenting computational fluid dynamics (CFD) simulation models.

Results

Before and after the stent deployment, the average wall shear stress (WSS) on the aneurysmal sac at systolic peak changed from 7.04 Pa (4.14 Pa, 15.77 Pa) to 6.04 Pa (3.86 Pa, 11.13 Pa), P = 0.001; the spatially averaged flow velocity in the perpendicular plane of the aneurysm dropped from 0.5 m/s (0.28 m/s, 0.7 m/s) to 0.33 m/s (0.25 m/s, 0.49 m/s), P = 0.001, respectively. Post stent implantation, the WSS in ICA-OphA aneurysms and PcoA aneurysms decreased by 14.4 % (P = 0.012) and 16.6 % (P = 0.018), respectively, and the flow velocity also reduced by 10.3 % (P = 0.029) and 10.5 % (P = 0.013), respectively. Changes in the WSS, flow velocity, and pressure were not significantly different between ICA-OphA and PcoA aneurysms (P > 0.05). Stent implantation did not significantly change the peak systolic pressure in either aneurysm type.

Conclusion

After the stent implantation, both the intra-aneurysmal flow velocity and WSS decreased independently of aneurysm type (ICA-OphA and PcoA). Little change was observed in peak systolic pressure.
Literatur
1.
Zurück zum Zitat Augsburger L, Reymond P, Rufenacht DA, Stergiopulos N (2011) Intracranial stents being modeled as a porous medium: flow simulation in stented cerebral aneurysms. Ann Biomed Eng 39:850–863CrossRefPubMed Augsburger L, Reymond P, Rufenacht DA, Stergiopulos N (2011) Intracranial stents being modeled as a porous medium: flow simulation in stented cerebral aneurysms. Ann Biomed Eng 39:850–863CrossRefPubMed
2.
Zurück zum Zitat Bernardini A, Larrabide I, Morales HG, Pennati G, Petrini L, Cito S, Frangi AF (2011) Influence of different computational approaches for stent deployment on cerebral aneurysm haemodynamics. Interface Focus 1:338–348CrossRefPubMedPubMedCentral Bernardini A, Larrabide I, Morales HG, Pennati G, Petrini L, Cito S, Frangi AF (2011) Influence of different computational approaches for stent deployment on cerebral aneurysm haemodynamics. Interface Focus 1:338–348CrossRefPubMedPubMedCentral
3.
Zurück zum Zitat Bernardini A, Larrabide I, Petrini L, Pennati G, Flore E, Kim M, Frangi AF (2012) Deployment of self-expandable stents in aneurysmatic cerebral vessels: comparison of different computational approaches for interventional planning. Comp Methods Biomech Biomed Engin 15:303–311CrossRef Bernardini A, Larrabide I, Petrini L, Pennati G, Flore E, Kim M, Frangi AF (2012) Deployment of self-expandable stents in aneurysmatic cerebral vessels: comparison of different computational approaches for interventional planning. Comp Methods Biomech Biomed Engin 15:303–311CrossRef
4.
Zurück zum Zitat Chalouhi N, Jabbour P, Gonzalez LF, Dumont AS, Rosenwasser R, Starke RM, Gordon D, Hann S, Tjoumakaris S (2012) Safety and efficacy of endovascular treatment of basilar tip aneurysms by coiling with and without stent assistance: a review of 235 cases. Neurosurgery 71:785–794CrossRefPubMed Chalouhi N, Jabbour P, Gonzalez LF, Dumont AS, Rosenwasser R, Starke RM, Gordon D, Hann S, Tjoumakaris S (2012) Safety and efficacy of endovascular treatment of basilar tip aneurysms by coiling with and without stent assistance: a review of 235 cases. Neurosurgery 71:785–794CrossRefPubMed
5.
Zurück zum Zitat Clajus C, Sychra V, Strasilla C, Klisch J (2013) Stent-assisted coil embolization of intracranial aneurysms using the Solitaire AB Neurovascular Remodeling Device: initial and midterm follow-up results. Neuroradiology 55:629–638CrossRefPubMed Clajus C, Sychra V, Strasilla C, Klisch J (2013) Stent-assisted coil embolization of intracranial aneurysms using the Solitaire AB Neurovascular Remodeling Device: initial and midterm follow-up results. Neuroradiology 55:629–638CrossRefPubMed
6.
Zurück zum Zitat Francis SE, Tu J, Qian Y, Avolio AP (2013) A combination of genetic, molecular and haemodynamic risk factors contributes to the formation, enlargement and rupture of brain aneurysms. J Clin Neurosci 20:912–918CrossRefPubMed Francis SE, Tu J, Qian Y, Avolio AP (2013) A combination of genetic, molecular and haemodynamic risk factors contributes to the formation, enlargement and rupture of brain aneurysms. J Clin Neurosci 20:912–918CrossRefPubMed
7.
Zurück zum Zitat Frosen J (2014) Smooth muscle cells and the formation, degeneration, and rupture of saccular intracranial aneurysm wall—a review of current pathophysiological knowledge. Transl Stroke Res 5:347–356CrossRefPubMed Frosen J (2014) Smooth muscle cells and the formation, degeneration, and rupture of saccular intracranial aneurysm wall—a review of current pathophysiological knowledge. Transl Stroke Res 5:347–356CrossRefPubMed
8.
Zurück zum Zitat Frosen J, Tulamo R, Paetau A, Laaksamo E, Korja M, Laakso A, Niemela M, Hernesniemi J (2012) Saccular intracranial aneurysm: pathology and mechanisms. Acta Neuropathol 123:773–786CrossRefPubMed Frosen J, Tulamo R, Paetau A, Laaksamo E, Korja M, Laakso A, Niemela M, Hernesniemi J (2012) Saccular intracranial aneurysm: pathology and mechanisms. Acta Neuropathol 123:773–786CrossRefPubMed
9.
Zurück zum Zitat Fu W, Gu Z, Meng X, Chu B, Qiao A (2010) Numerical simulation of hemodynamics in stented internal carotid aneurysm based on patient-specific model. J Biomech 43:1337–1342CrossRefPubMed Fu W, Gu Z, Meng X, Chu B, Qiao A (2010) Numerical simulation of hemodynamics in stented internal carotid aneurysm based on patient-specific model. J Biomech 43:1337–1342CrossRefPubMed
10.
Zurück zum Zitat Hong Y, Wang YJ, Deng Z, Wu Q, Zhang JM (2014) Stent-assisted coiling versus coiling in treatment of intracranial aneurysm: a systematic review and meta-analysis. PLoS One 9:e82311CrossRefPubMedPubMedCentral Hong Y, Wang YJ, Deng Z, Wu Q, Zhang JM (2014) Stent-assisted coiling versus coiling in treatment of intracranial aneurysm: a systematic review and meta-analysis. PLoS One 9:e82311CrossRefPubMedPubMedCentral
11.
Zurück zum Zitat Kim M, Levy EI, Meng H, Hopkins LN (2007) Quantification of hemodynamic changes induced by virtual placement of multiple stents across a wide-necked basilar trunk aneurysm. Neurosurgery 61:1305–1312, discussion 1312–1303CrossRefPubMedPubMedCentral Kim M, Levy EI, Meng H, Hopkins LN (2007) Quantification of hemodynamic changes induced by virtual placement of multiple stents across a wide-necked basilar trunk aneurysm. Neurosurgery 61:1305–1312, discussion 1312–1303CrossRefPubMedPubMedCentral
12.
13.
Zurück zum Zitat Kojima M, Irie K, Fukuda T, Arai F, Hirose Y, Negoro M (2012) The study of flow diversion effects on aneurysm using multiple enterprise stents and two flow diverters. Asian J Neurosurg 7:159–165CrossRefPubMedPubMedCentral Kojima M, Irie K, Fukuda T, Arai F, Hirose Y, Negoro M (2012) The study of flow diversion effects on aneurysm using multiple enterprise stents and two flow diverters. Asian J Neurosurg 7:159–165CrossRefPubMedPubMedCentral
14.
Zurück zum Zitat Kono K, Shintani A, Terada T (2014) Hemodynamic effects of stent struts versus straightening of vessels in stent-assisted coil embolization for sidewall cerebral aneurysms. PLoS One 9:e108033CrossRefPubMedPubMedCentral Kono K, Shintani A, Terada T (2014) Hemodynamic effects of stent struts versus straightening of vessels in stent-assisted coil embolization for sidewall cerebral aneurysms. PLoS One 9:e108033CrossRefPubMedPubMedCentral
15.
Zurück zum Zitat Krings T, Mandell DM, Kiehl TR, Geibprasert S, Tymianski M, Alvarez H, terBrugge KG, Hans FJ (2011) Intracranial aneurysms: from vessel wall pathology to therapeutic approach. Nat Rev Neurol 7:547–559CrossRefPubMed Krings T, Mandell DM, Kiehl TR, Geibprasert S, Tymianski M, Alvarez H, terBrugge KG, Hans FJ (2011) Intracranial aneurysms: from vessel wall pathology to therapeutic approach. Nat Rev Neurol 7:547–559CrossRefPubMed
16.
Zurück zum Zitat Larrabide I, Kim M, Augsburger L, Villa-Uriol MC, Rufenacht D, Frangi AF (2012) Fast virtual deployment of self-expandable stents: method and in vitro evaluation for intracranial aneurysmal stenting. Med Image Anal 16:721–730CrossRefPubMed Larrabide I, Kim M, Augsburger L, Villa-Uriol MC, Rufenacht D, Frangi AF (2012) Fast virtual deployment of self-expandable stents: method and in vitro evaluation for intracranial aneurysmal stenting. Med Image Anal 16:721–730CrossRefPubMed
17.
Zurück zum Zitat Lawson MF, Newman WC, Chi YY, Mocco JD, Hoh BL (2011) Stent-associated flow remodeling causes further occlusion of incompletely coiled aneurysms. Neurosurgery 69:598–603, discussion 603–594CrossRefPubMed Lawson MF, Newman WC, Chi YY, Mocco JD, Hoh BL (2011) Stent-associated flow remodeling causes further occlusion of incompletely coiled aneurysms. Neurosurgery 69:598–603, discussion 603–594CrossRefPubMed
18.
Zurück zum Zitat Lopes D, Sani S (2005) Histological postmortem study of an internal carotid artery aneurysm treated with the Neuroform stent. Neurosurgery 56:E416, discussion E416CrossRefPubMed Lopes D, Sani S (2005) Histological postmortem study of an internal carotid artery aneurysm treated with the Neuroform stent. Neurosurgery 56:E416, discussion E416CrossRefPubMed
19.
Zurück zum Zitat Meng H, Tutino VM, Xiang J, Siddiqui A (2014) High WSS or low WSS? Complex interactions of hemodynamics with intracranial aneurysm initiation, growth, and rupture: toward a unifying hypothesis. AJNR Am J Neuroradiol 35:1254–1262CrossRefPubMed Meng H, Tutino VM, Xiang J, Siddiqui A (2014) High WSS or low WSS? Complex interactions of hemodynamics with intracranial aneurysm initiation, growth, and rupture: toward a unifying hypothesis. AJNR Am J Neuroradiol 35:1254–1262CrossRefPubMed
20.
Zurück zum Zitat Metaxa E, Tremmel M, Natarajan SK, Xiang J, Paluch RA, Mandelbaum M, Siddiqui AH, Kolega J, Mocco J, Meng H (2010) Characterization of critical hemodynamics contributing to aneurysmal remodeling at the basilar terminus in a rabbit model. Stroke 41:1774–1782CrossRefPubMedPubMedCentral Metaxa E, Tremmel M, Natarajan SK, Xiang J, Paluch RA, Mandelbaum M, Siddiqui AH, Kolega J, Mocco J, Meng H (2010) Characterization of critical hemodynamics contributing to aneurysmal remodeling at the basilar terminus in a rabbit model. Stroke 41:1774–1782CrossRefPubMedPubMedCentral
21.
Zurück zum Zitat Mut F, Aubry R, Lohner R, Cebral JR (2010) Fast numerical solutions of patient-specific blood flows in 3D arterial systems. Int J Numer Methods Biomed Eng 26:73–85CrossRef Mut F, Aubry R, Lohner R, Cebral JR (2010) Fast numerical solutions of patient-specific blood flows in 3D arterial systems. Int J Numer Methods Biomed Eng 26:73–85CrossRef
22.
Zurück zum Zitat Paliwal N, Yu H, Damiano R, Xiang J, Yang X, Siddiqui A, Li H, Meng H (2014) Fast virtual stenting with vessel-specific initialization and collision detection. ASME International Design Engineering Technical Conferences and Computers and Information in Engineering Conference, American Society of Mechanical Engineers, Buffalo, NYCrossRef Paliwal N, Yu H, Damiano R, Xiang J, Yang X, Siddiqui A, Li H, Meng H (2014) Fast virtual stenting with vessel-specific initialization and collision detection. ASME International Design Engineering Technical Conferences and Computers and Information in Engineering Conference, American Society of Mechanical Engineers, Buffalo, NYCrossRef
23.
Zurück zum Zitat Piotin M, Blanc R, Spelle L, Mounayer C, Piantino R, Schmidt PJ, Moret J (2010) Stent-assisted coiling of intracranial aneurysms: clinical and angiographic results in 216 consecutive aneurysms. Stroke 41:110–115CrossRefPubMed Piotin M, Blanc R, Spelle L, Mounayer C, Piantino R, Schmidt PJ, Moret J (2010) Stent-assisted coiling of intracranial aneurysms: clinical and angiographic results in 216 consecutive aneurysms. Stroke 41:110–115CrossRefPubMed
24.
Zurück zum Zitat Rayz VL, Boussel L, Lawton MT, Acevedo-Bolton G, Ge L, Young WL, Higashida RT, Saloner D (2008) Numerical modeling of the flow in intracranial aneurysms: prediction of regions prone to thrombus formation. Ann Biomed Eng 36:1793–1804CrossRefPubMedPubMedCentral Rayz VL, Boussel L, Lawton MT, Acevedo-Bolton G, Ge L, Young WL, Higashida RT, Saloner D (2008) Numerical modeling of the flow in intracranial aneurysms: prediction of regions prone to thrombus formation. Ann Biomed Eng 36:1793–1804CrossRefPubMedPubMedCentral
25.
Zurück zum Zitat Shobayashi Y, Tateshima S, Kakizaki R, Sudo R, Tanishita K, Vinuela F (2013) Intra-aneurysmal hemodynamic alterations by a self-expandable intracranial stent and flow diversion stent: high intra-aneurysmal pressure remains regardless of flow velocity reduction. J Neurointerv Surg 5(Suppl 3):iii38–iii42CrossRefPubMed Shobayashi Y, Tateshima S, Kakizaki R, Sudo R, Tanishita K, Vinuela F (2013) Intra-aneurysmal hemodynamic alterations by a self-expandable intracranial stent and flow diversion stent: high intra-aneurysmal pressure remains regardless of flow velocity reduction. J Neurointerv Surg 5(Suppl 3):iii38–iii42CrossRefPubMed
26.
Zurück zum Zitat Spranger K, Ventikos Y (2014) Which spring is the best? Comparison of methods for virtual stenting. IEEE Trans Bio-Med Eng 61:1998–2010CrossRef Spranger K, Ventikos Y (2014) Which spring is the best? Comparison of methods for virtual stenting. IEEE Trans Bio-Med Eng 61:1998–2010CrossRef
27.
Zurück zum Zitat Tanemura H, Ishida F, Miura Y, Umeda Y, Fukazawa K, Suzuki H, Sakaida H, Matsushima S, Shimosaka S, Taki W (2013) Changes in hemodynamics after placing intracranial stents. Neurol Med Chir 53:171–178CrossRef Tanemura H, Ishida F, Miura Y, Umeda Y, Fukazawa K, Suzuki H, Sakaida H, Matsushima S, Shimosaka S, Taki W (2013) Changes in hemodynamics after placing intracranial stents. Neurol Med Chir 53:171–178CrossRef
28.
Zurück zum Zitat Wanke I, Forsting M (2008) Stents for intracranial wide-necked aneurysms: more than mechanical protection. Neuroradiology 50:991–998CrossRefPubMed Wanke I, Forsting M (2008) Stents for intracranial wide-necked aneurysms: more than mechanical protection. Neuroradiology 50:991–998CrossRefPubMed
Metadaten
Titel
Hemodynamic alterations after stent implantation in 15 cases of intracranial aneurysm
verfasst von
Chao Wang
Zhongbin Tian
Jian Liu
Linkai Jing
Nikhil Paliwal
Shengzhang Wang
Ying Zhang
Jianping Xiang
Adnan H. Siddiqui
Hui Meng
Xinjian Yang
Publikationsdatum
01.04.2016
Verlag
Springer Vienna
Erschienen in
Acta Neurochirurgica / Ausgabe 4/2016
Print ISSN: 0001-6268
Elektronische ISSN: 0942-0940
DOI
https://doi.org/10.1007/s00701-015-2696-x

Weitere Artikel der Ausgabe 4/2016

Acta Neurochirurgica 4/2016 Zur Ausgabe

Leitlinien kompakt für die Neurologie

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders gilt das offenbar für weibliche Kranke, wie eine Studie zeigt.

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Niedriger diastolischer Blutdruck erhöht Risiko für schwere kardiovaskuläre Komplikationen

25.04.2024 Hypotonie Nachrichten

Wenn unter einer medikamentösen Hochdrucktherapie der diastolische Blutdruck in den Keller geht, steigt das Risiko für schwere kardiovaskuläre Ereignisse: Darauf deutet eine Sekundäranalyse der SPRINT-Studie hin.

Frühe Alzheimertherapie lohnt sich

25.04.2024 AAN-Jahrestagung 2024 Nachrichten

Ist die Tau-Last noch gering, scheint der Vorteil von Lecanemab besonders groß zu sein. Und beginnen Erkrankte verzögert mit der Behandlung, erreichen sie nicht mehr die kognitive Leistung wie bei einem früheren Start. Darauf deuten neue Analysen der Phase-3-Studie Clarity AD.

Update Neurologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.