His bundle pacing: troubleshooting during follow-up

verfasst von: PD Dr. med. Carsten W. Israel, Sona Tribunyan

Erschienen in: Herzschrittmachertherapie + Elektrophysiologie | Ausgabe 2/2020

Einloggen, um Zugang zu erhalten

Abstract

Follow-up of pacemaker systems for His bundle pacing (HBP) requires electrocardiogram (ECG) knowledge and creative thinking. This relates to ventricular threshold measurement in which it can be difficult to distinguish between selective HBP and loss of capture with pseudofusion since, by definition, intrinsic QRS complexes and those selectively paced via the His bundle look identical. Threshold testing in HBP is best performed in unipolar pacing mode, recording of a 12-lead ECG and pacing in VVI mode significantly above the intrinsic rate. Peculiarities of HBP relate to oversensing by the His bundle lead of atrial activity or the His bundle potential itself, leading to ventricular asystole or incorrect measurements during sensing testing. Ventricular undersensing and the use of His bundle plus additional right ventricular leads may lead to complex ECGs. However, other daily pacemaker problems (such as tachycardia above the upper rate limit or premature beats) and specific phenomena (such as paradoxical cardiac memory) may also be demanding in ECG troubleshooting of HBP.
Literatur
1.
Zurück zum Zitat Jastrzębski M, Moskal P, Curila K, Fijorek K, Kukla P, Bednarek A, Kiełbasa G, Bednarski A, Baranchuk A, Czarnecka D (2019) Electrocardiographic characterization of non-selective His-bundle pacing: validation of novel diagnostic criteria. Europace. https://doi.org/10.1093/europace/euz275 (epub before print)CrossRefPubMed Jastrzębski M, Moskal P, Curila K, Fijorek K, Kukla P, Bednarek A, Kiełbasa G, Bednarski A, Baranchuk A, Czarnecka D (2019) Electrocardiographic characterization of non-selective His-bundle pacing: validation of novel diagnostic criteria. Europace. https://​doi.​org/​10.​1093/​europace/​euz275 (epub before print)CrossRefPubMed
2.
Zurück zum Zitat Vijayaraman P, Dandamudi G, Miller JM (2014) Paradoxical cardiac memory during permanent His bundle pacing. J Cardiovasc Electrophysiol 25:545–546CrossRef Vijayaraman P, Dandamudi G, Miller JM (2014) Paradoxical cardiac memory during permanent His bundle pacing. J Cardiovasc Electrophysiol 25:545–546CrossRef
Metadaten
Titel
His bundle pacing: troubleshooting during follow-up
verfasst von
PD Dr. med. Carsten W. Israel
Sona Tribunyan
Publikationsdatum
28.05.2020
Verlag
Springer Medizin
Erschienen in
Herzschrittmachertherapie + Elektrophysiologie / Ausgabe 2/2020
Print ISSN: 0938-7412
Elektronische ISSN: 1435-1544
DOI
https://doi.org/10.1007/s00399-020-00693-9

Weitere Artikel der Ausgabe 2/2020

Herzschrittmachertherapie + Elektrophysiologie 2/2020 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.