Abstract

Background

Different types of external fixators have been used for humeral lengthening with successful outcomes reported in literature. Motorized intramedullary (IM) lengthening nails have been developed as an alternative to external fixators for long bone lengthening in the lower extremity.

Questions/Purposes

This case series reports on using the new technology of IM lengthening nails for humeral lengthening. We assessed the radiological healing and functional outcomes after using the PRECICE IM nail for humeral lengthening.

Methods

This multicenter retrospective study included a total of six humeri in five patients (mean age was 20 years) that underwent lengthening with the magnetic IM PRECICE nail in two centers in the USA. The etiology was humeral growth arrest post-bone cyst (two segments), post-septic growth arrest (two segments), and multiple hereditary exostosis (bilateral segments in one patient). The outcomes measured were the length achieved, distraction index (DI; the length achieved in mm divided by the duration of lengthening in days), consolidation index (CI; number of days from surgery until consolidation divided by the length of the regenerate in cm), complications encountered, and functional outcomes (shoulder and elbow range of motion, the upper extremity functional index (UEFI), and QuickDASH functional scores).

Results

The mean follow-up period was 1.8 years (0.9 to 2.4 years). All segments achieved the goal of lengthening; the mean was 5.1 cm (4.5 to 5.8 cm). Mean DI was 0.7 mm/day (0.5 to 0.8). Mean CI was 36 days/cm (25 to 45 days/cm). No complications were observed. At the last follow-up, all patients maintained their preoperative range of motion (ROM) except one patient had reduced shoulder ROM. QuickDASH score and upper extremity functional index showed postoperative improvement compared to the preoperative scores.

Conclusion

IM lengthening nails can provide successful and safe humeral lengthening. Specifically, the PRECICE nail has accurate control over the lengthening process.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Accadbled F, Pailhé R, Cavaignac E, Sales de Gauzy J. Bone lengthening using the Fitbone(®) motorized intramedullary nail: The first experience in France. Orthop Traumatol Surg Res. 2016. Accadbled F, Pailhé R, Cavaignac E, Sales de Gauzy J. Bone lengthening using the Fitbone(®) motorized intramedullary nail: The first experience in France. Orthop Traumatol Surg Res. 2016.
2.
Zurück zum Zitat Al-Sayyad MJ. Taylor spatial frame in the treatment of upper extremity conditions. J Pediatr Orthop 2012; 32: 169–178.CrossRefPubMed Al-Sayyad MJ. Taylor spatial frame in the treatment of upper extremity conditions. J Pediatr Orthop 2012; 32: 169–178.CrossRefPubMed
3.
Zurück zum Zitat Babatunde OM, Fragomen AT, Rozbruch SR. Noninvasive quantitative assessment of bone healing after distraction osteogenesis. HSS J. 2010;6(1):71–8.CrossRefPubMed Babatunde OM, Fragomen AT, Rozbruch SR. Noninvasive quantitative assessment of bone healing after distraction osteogenesis. HSS J. 2010;6(1):71–8.CrossRefPubMed
4.
Zurück zum Zitat Balci HI, Kocaoglu M, Sen C, Eralp L, Batibay SG, Bilsel K. Bilateral humeral lengthening in achondroplasia with unilateral external fixators: is it safe and does it improve daily life? Bone Joint J. 2015;97-B(11):1577–81.CrossRefPubMed Balci HI, Kocaoglu M, Sen C, Eralp L, Batibay SG, Bilsel K. Bilateral humeral lengthening in achondroplasia with unilateral external fixators: is it safe and does it improve daily life? Bone Joint J. 2015;97-B(11):1577–81.CrossRefPubMed
5.
Zurück zum Zitat Beaton DE, Wright JG, Katz JN. Upper Extremity Collaborative Group Development of the QuickDASH: comparison of three item-reduction approaches. J Bone Joint Surg Am. 2005 May;87(5):1038–46.PubMed Beaton DE, Wright JG, Katz JN. Upper Extremity Collaborative Group Development of the QuickDASH: comparison of three item-reduction approaches. J Bone Joint Surg Am. 2005 May;87(5):1038–46.PubMed
6.
Zurück zum Zitat Belthur MV, Iobst CA, Bor N, Segev E, Eidelman M, Standard SC, Herzenberg JE. Correction of cubitus varus after pediatric supracondylar elbow fracture: alternative method using the Taylor spatial frame. J Pediatr Orthop. 2015. Belthur MV, Iobst CA, Bor N, Segev E, Eidelman M, Standard SC, Herzenberg JE. Correction of cubitus varus after pediatric supracondylar elbow fracture: alternative method using the Taylor spatial frame. J Pediatr Orthop. 2015.
7.
Zurück zum Zitat Black SR, Kwon MS, Cherkashin AM, Samchukov ML, Birch JG, Jo CH. Lengthening in congenital femoral deficiency: a comparison of circular external fixation and a motorized intramedullary nail. J Bone Joint Surg Am. 2015;97(17):1432–40.CrossRefPubMed Black SR, Kwon MS, Cherkashin AM, Samchukov ML, Birch JG, Jo CH. Lengthening in congenital femoral deficiency: a comparison of circular external fixation and a motorized intramedullary nail. J Bone Joint Surg Am. 2015;97(17):1432–40.CrossRefPubMed
8.
Zurück zum Zitat Cattaneo R, Catagni MA, Guerreschi F. Applications of the Ilizarov method in the humerus. Lengthenings and nonunions. Hand Clin. 1993;9(4):729–39.PubMed Cattaneo R, Catagni MA, Guerreschi F. Applications of the Ilizarov method in the humerus. Lengthenings and nonunions. Hand Clin. 1993;9(4):729–39.PubMed
9.
Zurück zum Zitat Cattaneo R, Villa A, Catagni MA, Bell D. Lengthening of the humerus using the Ilizarov technique. Description of the method and report of 43 cases. Clin Orthop Relat Res. 1990;(250):117–24. Cattaneo R, Villa A, Catagni MA, Bell D. Lengthening of the humerus using the Ilizarov technique. Description of the method and report of 43 cases. Clin Orthop Relat Res. 1990;(250):117–24.
10.
Zurück zum Zitat Chesworth BM, Hamilton CB, Walton DM, Benoit M, Blake TA, Bredy H, Burns C, Chan L, Frey E, Gillies G, Gravelle T, Ho R, Holmes R, Lavallée RL, MacKinnon M, Merchant AJ, Sherman T, Spears K, Yardley D. Reliability and validity of two versions of the upper extremity functional index. Physiother Can. 2014; 66(3):243–53.CrossRefPubMedPubMedCentral Chesworth BM, Hamilton CB, Walton DM, Benoit M, Blake TA, Bredy H, Burns C, Chan L, Frey E, Gillies G, Gravelle T, Ho R, Holmes R, Lavallée RL, MacKinnon M, Merchant AJ, Sherman T, Spears K, Yardley D. Reliability and validity of two versions of the upper extremity functional index. Physiother Can. 2014; 66(3):243–53.CrossRefPubMedPubMedCentral
11.
Zurück zum Zitat Dal Monte A, Andrisano A, Manfrini M, Zucchi M. Humeral lengthening in hypoplasia of the upper limb. J Pediatr Orthop. 1985;5(2):202–7.CrossRefPubMed Dal Monte A, Andrisano A, Manfrini M, Zucchi M. Humeral lengthening in hypoplasia of the upper limb. J Pediatr Orthop. 1985;5(2):202–7.CrossRefPubMed
12.
Zurück zum Zitat Damsin JP, Ghanem I. Upper limb lengthening. Hand Clin. 2000;16(4):685–701.PubMed Damsin JP, Ghanem I. Upper limb lengthening. Hand Clin. 2000;16(4):685–701.PubMed
13.
Zurück zum Zitat Gummesson C, Ward MM, Atroshi I. The shortened disabilities of the arm, shoulder and hand questionnaire (QuickDASH): validity and reliability based on responses within the full-length DASH. BMC Musculoskelet Disord. 2006;7:44.CrossRefPubMedPubMedCentral Gummesson C, Ward MM, Atroshi I. The shortened disabilities of the arm, shoulder and hand questionnaire (QuickDASH): validity and reliability based on responses within the full-length DASH. BMC Musculoskelet Disord. 2006;7:44.CrossRefPubMedPubMedCentral
14.
Zurück zum Zitat Herzenberg JE. Humeral lengthening and realignment. In, Rozbruch SR, Ilizarov S eds. Limb Lengthening and Reconstruction Surgery. New York: Informa Healthcare; 2007;ch 39:535–543. Herzenberg JE. Humeral lengthening and realignment. In, Rozbruch SR, Ilizarov S eds. Limb Lengthening and Reconstruction Surgery. New York: Informa Healthcare; 2007;ch 39:535–543.
15.
Zurück zum Zitat Hosny GA. Unilateral humeral lengthening in children and adolescents. J Pediatr Orthop B. 2005;14:439–443.CrossRefPubMed Hosny GA. Unilateral humeral lengthening in children and adolescents. J Pediatr Orthop B. 2005;14:439–443.CrossRefPubMed
16.
Zurück zum Zitat Kashiwagi N, Suzuki S, Seto Y, Futami T. Bilateral humeral lengthening in achondroplasia. Clin Orthop Relat Res. 2001;391: 251–257.CrossRef Kashiwagi N, Suzuki S, Seto Y, Futami T. Bilateral humeral lengthening in achondroplasia. Clin Orthop Relat Res. 2001;391: 251–257.CrossRef
17.
Zurück zum Zitat Katz K, Goldberg I, Bahar A, Yosipovitch Z. Humeral lengthening for septic neonatal growth arrest. J Hand Surg Am. 1989; 14:903–907.CrossRefPubMed Katz K, Goldberg I, Bahar A, Yosipovitch Z. Humeral lengthening for septic neonatal growth arrest. J Hand Surg Am. 1989; 14:903–907.CrossRefPubMed
18.
Zurück zum Zitat Kim SJ, Agashe MV, Song SH, Choi HJ, Lee H, Song HR. Comparison between upper and lower limb lengthening in patients with achondroplasia: a retrospective study. J Bone Joint Surg Br. 2012;94(1):128–33.CrossRefPubMed Kim SJ, Agashe MV, Song SH, Choi HJ, Lee H, Song HR. Comparison between upper and lower limb lengthening in patients with achondroplasia: a retrospective study. J Bone Joint Surg Br. 2012;94(1):128–33.CrossRefPubMed
19.
Zurück zum Zitat Kiss S, Pap K, Vízkelety T, Terebessy T, Balla M, Szoke G. The humerus is the best place for bone lengthening. Int Orthop. 2008;32(3):385–8.CrossRefPubMed Kiss S, Pap K, Vízkelety T, Terebessy T, Balla M, Szoke G. The humerus is the best place for bone lengthening. Int Orthop. 2008;32(3):385–8.CrossRefPubMed
20.
Zurück zum Zitat Kurtz AM, Rozbruch SR. Humerus Lengthening With the PRECICE Internal Lengthening Nail. J Pediatr Orthop. 2017 Feb 27. Kurtz AM, Rozbruch SR. Humerus Lengthening With the PRECICE Internal Lengthening Nail. J Pediatr Orthop. 2017 Feb 27.
21.
Zurück zum Zitat Lädermann A, Edwards TB, Walch G. Arm lengthening after reverse shoulder arthroplasty: a review. Int Orthop. 2014;38(5):991–1000.CrossRefPubMed Lädermann A, Edwards TB, Walch G. Arm lengthening after reverse shoulder arthroplasty: a review. Int Orthop. 2014;38(5):991–1000.CrossRefPubMed
22.
Zurück zum Zitat Lee FY, Schoeb JS, Yu J, Christiansen BD, Dick HM. Operative lengthening of the humerus: indications, benefits, and complications. J Pediatr Orthop. 2005;25:613–616.CrossRefPubMed Lee FY, Schoeb JS, Yu J, Christiansen BD, Dick HM. Operative lengthening of the humerus: indications, benefits, and complications. J Pediatr Orthop. 2005;25:613–616.CrossRefPubMed
23.
Zurück zum Zitat Malot R, Park KW, Song SH, Kwon HN, Song HR. Role of hybrid monolateral fixators in managing humeral length and deformity correction. Acta Orthop. 2013;84(3):280–5.CrossRefPubMedPubMedCentral Malot R, Park KW, Song SH, Kwon HN, Song HR. Role of hybrid monolateral fixators in managing humeral length and deformity correction. Acta Orthop. 2013;84(3):280–5.CrossRefPubMedPubMedCentral
24.
Zurück zum Zitat McCarthy JJ, Iobst CA, Rozbruch SR, Sabharwal S, Eismann EA. Limb Lengthening and Reconstruction Society AIM index reliably assesses lower limb deformity. Clin Orthop Relat Res. 2013;471(2):621–7.CrossRefPubMed McCarthy JJ, Iobst CA, Rozbruch SR, Sabharwal S, Eismann EA. Limb Lengthening and Reconstruction Society AIM index reliably assesses lower limb deformity. Clin Orthop Relat Res. 2013;471(2):621–7.CrossRefPubMed
25.
Zurück zum Zitat McCarthy JJ, Ranade A, Davidson RS. Pediatric deformity correction using a multiaxial correction fixator. Clin Orthop Relat Res 2008; 466:3011–3017.CrossRefPubMedPubMedCentral McCarthy JJ, Ranade A, Davidson RS. Pediatric deformity correction using a multiaxial correction fixator. Clin Orthop Relat Res 2008; 466:3011–3017.CrossRefPubMedPubMedCentral
26.
Zurück zum Zitat McLawhorn AS, Sherman SL, Blyakher A, Widmann RF. Humeral lengthening and deformity correction with the multiaxial correction system. J Pediatr Orthop B 2011; 20: 111–116.CrossRefPubMed McLawhorn AS, Sherman SL, Blyakher A, Widmann RF. Humeral lengthening and deformity correction with the multiaxial correction system. J Pediatr Orthop B 2011; 20: 111–116.CrossRefPubMed
27.
Zurück zum Zitat Paley D. PRECICE intramedullary limb lengthening system. Expert Rev Med Devices. 2015;12(3):231–49.CrossRefPubMed Paley D. PRECICE intramedullary limb lengthening system. Expert Rev Med Devices. 2015;12(3):231–49.CrossRefPubMed
28.
Zurück zum Zitat Paley D, Herzenberg JE, Bor N. Fixator-assisted nailing of femoral and tibial deformities. Techniques in Orthopaedics. 1997;12(4): 260–275.CrossRef Paley D, Herzenberg JE, Bor N. Fixator-assisted nailing of femoral and tibial deformities. Techniques in Orthopaedics. 1997;12(4): 260–275.CrossRef
29.
Zurück zum Zitat Pawar AY, McCoy TH Jr, Fragomen AT, Rozbruch SR. Does humeral lengthening with a monolateral frame improve function? Clin Orthop Relat Res. 2013; 471: 277–283.CrossRefPubMed Pawar AY, McCoy TH Jr, Fragomen AT, Rozbruch SR. Does humeral lengthening with a monolateral frame improve function? Clin Orthop Relat Res. 2013; 471: 277–283.CrossRefPubMed
30.
Zurück zum Zitat Popkov D, Popkov A, Haumont T, Journeau P, Lascombes P. Flexible intramedullary nail use in limb lengthening. J Pediatr Orthop. 2010;30(8):910–8.CrossRefPubMed Popkov D, Popkov A, Haumont T, Journeau P, Lascombes P. Flexible intramedullary nail use in limb lengthening. J Pediatr Orthop. 2010;30(8):910–8.CrossRefPubMed
31.
Zurück zum Zitat Shabtai L, Specht SC, Standard SC, Herzenberg JE. Internal lengthening device for congenital femoral deficiency and fibular hemimelia. Clin Orthop Relat Res. 2014;472(12):3860–8.CrossRefPubMedPubMedCentral Shabtai L, Specht SC, Standard SC, Herzenberg JE. Internal lengthening device for congenital femoral deficiency and fibular hemimelia. Clin Orthop Relat Res. 2014;472(12):3860–8.CrossRefPubMedPubMedCentral
32.
Zurück zum Zitat Shevtsov VI, Popkov AV, Popkov DA, Yerofeev SA, Prévot J, Lascombes P. Elastic stable intramedullary nailing in Ilizarov bone lengthening. Rev Chir Orthop Reparatrice Appar Mot. 2004;90(5):399–410. French.CrossRefPubMed Shevtsov VI, Popkov AV, Popkov DA, Yerofeev SA, Prévot J, Lascombes P. Elastic stable intramedullary nailing in Ilizarov bone lengthening. Rev Chir Orthop Reparatrice Appar Mot. 2004;90(5):399–410. French.CrossRefPubMed
33.
Zurück zum Zitat Rozbruch SR, Birch JG, Dahl MT, Herzenberg JE. Motorized intramedullary nail for management of limb-length discrepancy and deformity. J Am Acad Orthop Surg. 2014;22(7):403–9.CrossRefPubMed Rozbruch SR, Birch JG, Dahl MT, Herzenberg JE. Motorized intramedullary nail for management of limb-length discrepancy and deformity. J Am Acad Orthop Surg. 2014;22(7):403–9.CrossRefPubMed
34.
Zurück zum Zitat Tellisi N, Ilizarov S, Fragomen AT, Rozbruch SR. Humeral lengthening and deformity correction in Ollier’s disease: distraction osteogenesis with a multiaxial correction frame. J Pediatr Orthop B 2008; 17:152–157.CrossRefPubMed Tellisi N, Ilizarov S, Fragomen AT, Rozbruch SR. Humeral lengthening and deformity correction in Ollier’s disease: distraction osteogenesis with a multiaxial correction frame. J Pediatr Orthop B 2008; 17:152–157.CrossRefPubMed
35.
Zurück zum Zitat Tetsworth K, Krome J, Paley D. Lengthening and deformity correction of the upper extremity by the Ilizarov technique. Orthop Clin North Am. 1991;22(4):689–713.PubMed Tetsworth K, Krome J, Paley D. Lengthening and deformity correction of the upper extremity by the Ilizarov technique. Orthop Clin North Am. 1991;22(4):689–713.PubMed
36.
Zurück zum Zitat Tiefenboeck TM, Zak L, Wozasek GE. Intramedullary magnetically actuated limb lengthening in a patient with congenital humeral limb shortening. Injury. 2016 Jul;47(7):1597-600 Tiefenboeck TM, Zak L, Wozasek GE. Intramedullary magnetically actuated limb lengthening in a patient with congenital humeral limb shortening. Injury. 2016 Jul;47(7):1597-600
37.
Zurück zum Zitat Yang CB, Huang SC. Humeral lengthening using the Ilizarov technique. J Formos. Med Assoc. 1997;96(4):291–4.PubMed Yang CB, Huang SC. Humeral lengthening using the Ilizarov technique. J Formos. Med Assoc. 1997;96(4):291–4.PubMed
Metadaten
Titel
Humeral Lengthening with the PRECICE Magnetic Lengthening Nail
verfasst von
Ahmed I. Hammouda, MD
Shawn C. Standard, MD
S. Robert Rozbruch, MD
John E. Herzenberg, MD
Publikationsdatum
21.04.2017
Verlag
Springer US
Erschienen in
HSS Journal ® / Ausgabe 3/2017
Print ISSN: 1556-3316
Elektronische ISSN: 1556-3324
DOI
https://doi.org/10.1007/s11420-017-9552-x

Weitere Artikel der Ausgabe 3/2017

HSS Journal ® 3/2017 Zur Ausgabe

Clinical Pathology Conference

Immunoglobulin G4-related Aortitis

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.