Skip to main content
Erschienen in: Current Cardiovascular Imaging Reports 11/2015

01.11.2015 | Echocardiography (T Buck, Section Editor)

Imaging During Percutaneous Valvular Heart DiseaseInterventions: Is More Better or Less?

verfasst von: Alejandra Carbonell San Román, José Luis Zamorano Gómez

Erschienen in: Current Cardiovascular Imaging Reports | Ausgabe 11/2015

Einloggen, um Zugang zu erhalten

Abstract

Percutaneous valvular interventions have become a valid option in the treatment of valvular heart disease (VHD) for patients with prohibited surgical risk and multiple comorbidities. Multimodality imaging plays an increasingly central role in the evaluation of these interventions in which precise guidance for appropriate and accurate positioning of the device is mandatory. This review will discuss the role of these imaging modalities in patient selection and the pre-procedural assessment of the valve, intra-procedural guidance and, ultimately, result evaluation.
Literatur
1.
Zurück zum Zitat Vahanian A, Alfieri O, Adreotti F, Antunes MJ, Baron-Esquivias G, Baumgartner H, et al. Guidelines on the management of valvular heart disease (version 2012): the joint task force on the management of valvular heart disease of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS). Eur Heart J. 2012;33:2451–96.PubMedCrossRef Vahanian A, Alfieri O, Adreotti F, Antunes MJ, Baron-Esquivias G, Baumgartner H, et al. Guidelines on the management of valvular heart disease (version 2012): the joint task force on the management of valvular heart disease of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS). Eur Heart J. 2012;33:2451–96.PubMedCrossRef
2.
Zurück zum Zitat Vahanian A, Alfieri O, Al-Attar N, Antus M, Bax J, Cormier B, et al. Transcathether valve implantation for patients with aortic stenosis: position statement from the European Association of Cardio-Thoracic Surgery (EACTS) and the European Society of Cardiology (ESC), in collaboration with the European Association of Percutaneous Cardiovascular Interventions (EAPCI). Eur Heart J. 2008;29:1463–70.PubMedCrossRef Vahanian A, Alfieri O, Al-Attar N, Antus M, Bax J, Cormier B, et al. Transcathether valve implantation for patients with aortic stenosis: position statement from the European Association of Cardio-Thoracic Surgery (EACTS) and the European Society of Cardiology (ESC), in collaboration with the European Association of Percutaneous Cardiovascular Interventions (EAPCI). Eur Heart J. 2008;29:1463–70.PubMedCrossRef
3.
Zurück zum Zitat Gurvitch R, Webb JG, Yuan R, Johnson M, Hague C, Wilson AB, et al. Aortic annulus diameter determination by multidetector computed tomography: reproducibility, applicability, and implications for transcatheter aortic valve implantation. J Am Coll Cardiol Intv. 2011;4(11):1235–45.CrossRef Gurvitch R, Webb JG, Yuan R, Johnson M, Hague C, Wilson AB, et al. Aortic annulus diameter determination by multidetector computed tomography: reproducibility, applicability, and implications for transcatheter aortic valve implantation. J Am Coll Cardiol Intv. 2011;4(11):1235–45.CrossRef
4.
Zurück zum Zitat Bloomfield GS, Gillam LD, Hahn RT, Kapadia S, Leipsic J, Lerakis S, et al. A practical guide to multimodality imaging of transcatheter aortic valve replacement. J Am Coll Cardiol Img. 2012;5(4):441–55.CrossRef Bloomfield GS, Gillam LD, Hahn RT, Kapadia S, Leipsic J, Lerakis S, et al. A practical guide to multimodality imaging of transcatheter aortic valve replacement. J Am Coll Cardiol Img. 2012;5(4):441–55.CrossRef
5.••
Zurück zum Zitat Zamorano JL, Badano LP, Bruce C, Chan KL, Gonçalves A, Hahn RT, et al. EAE/ASE recommendations for the use of echocardiography in new transcatheter interventions for valvular heart disease. Eur Heart J. 2011;32(17):2189–214. This is one of the first expert consensus documents underlining the importance of echocardiography in the guidance of transcatheter valve procedures and its role in patient selection, preprocedural planning, intraprocedural support and postprocedural evaluation.PubMedCrossRef Zamorano JL, Badano LP, Bruce C, Chan KL, Gonçalves A, Hahn RT, et al. EAE/ASE recommendations for the use of echocardiography in new transcatheter interventions for valvular heart disease. Eur Heart J. 2011;32(17):2189–214. This is one of the first expert consensus documents underlining the importance of echocardiography in the guidance of transcatheter valve procedures and its role in patient selection, preprocedural planning, intraprocedural support and postprocedural evaluation.PubMedCrossRef
6.
Zurück zum Zitat Thomas M, Schymik G, Walther T, Himbert D, Lefevre T, Treede H, et al. One-year outcomes of cohort 1 in the Edwards SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) registry: the European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve. Circulation. 2011;124:425–33.PubMedCrossRef Thomas M, Schymik G, Walther T, Himbert D, Lefevre T, Treede H, et al. One-year outcomes of cohort 1 in the Edwards SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) registry: the European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve. Circulation. 2011;124:425–33.PubMedCrossRef
7.
Zurück zum Zitat Bax J, Delgado V, Bapat V, Baumgartner H, Collet JP, Erbel R, et al. Open issues in transcatheter aortic valve implantation. Part 2: procedural issues and outcomes after transcatheter aortic valve implantation. Eur Heart J. 2014;35:2627–38.PubMedCrossRef Bax J, Delgado V, Bapat V, Baumgartner H, Collet JP, Erbel R, et al. Open issues in transcatheter aortic valve implantation. Part 2: procedural issues and outcomes after transcatheter aortic valve implantation. Eur Heart J. 2014;35:2627–38.PubMedCrossRef
8.
Zurück zum Zitat Khatri PJ, Webb JG, Rodes-Cabau J, Fremes SE, Ruel M, Lau K, et al. Adverse effects associated with transcatheter aortic valve implantation: a meta-analysis of contemporary studies. Ann Intern Med. 2013;158:35–46.PubMedCrossRef Khatri PJ, Webb JG, Rodes-Cabau J, Fremes SE, Ruel M, Lau K, et al. Adverse effects associated with transcatheter aortic valve implantation: a meta-analysis of contemporary studies. Ann Intern Med. 2013;158:35–46.PubMedCrossRef
9.
Zurück zum Zitat Nishimura RA, Otto CM, Bonow RO, Carabello BA, Erwin 3rd JP, Guyton RA, et al. 2014 AHA/ACC guideline for the management of patients with valvular heart disease: executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines. Circulation. 2014;129(23):e521–643.PubMedCrossRef Nishimura RA, Otto CM, Bonow RO, Carabello BA, Erwin 3rd JP, Guyton RA, et al. 2014 AHA/ACC guideline for the management of patients with valvular heart disease: executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines. Circulation. 2014;129(23):e521–643.PubMedCrossRef
10.
Zurück zum Zitat Gilard M, Eltchaninoff H, Iung B, Donzeau-Gouge P, Chevreul K, Fajadet J, et al. Registry of transcatheter aortic-valve implantation in high-risk patients. N Engl J Med. 2012;366:1705–15.PubMedCrossRef Gilard M, Eltchaninoff H, Iung B, Donzeau-Gouge P, Chevreul K, Fajadet J, et al. Registry of transcatheter aortic-valve implantation in high-risk patients. N Engl J Med. 2012;366:1705–15.PubMedCrossRef
11.
Zurück zum Zitat Moat NE, Ludman P, de Belder MA, Bridgewater B, Cunningham AD, Young CP. Long-term outcomes after transcatheter aortic valve implantation in high-risk patients with severe aortic stenosis: the UK TAVI (United Kingdom Transcatheter Aortic Valve Implantation) Registry. J Am Coll Cardiol. 2011;58:2130–8.PubMedCrossRef Moat NE, Ludman P, de Belder MA, Bridgewater B, Cunningham AD, Young CP. Long-term outcomes after transcatheter aortic valve implantation in high-risk patients with severe aortic stenosis: the UK TAVI (United Kingdom Transcatheter Aortic Valve Implantation) Registry. J Am Coll Cardiol. 2011;58:2130–8.PubMedCrossRef
12.
Zurück zum Zitat Mack MJ, Brennan JM, Brindis R, Carroll J, Edwards F, Grover F, et al. Outcomes following transcatheter aortic valve replacement in the United States. JAMA. 2013;310:2069–77.PubMedCrossRef Mack MJ, Brennan JM, Brindis R, Carroll J, Edwards F, Grover F, et al. Outcomes following transcatheter aortic valve replacement in the United States. JAMA. 2013;310:2069–77.PubMedCrossRef
13.•
Zurück zum Zitat Athappan G, Patvardhan E, Tuzcu EM, Svensson LG, Lemos PA, Fraccaro C. Incidence, predictors, and outcomes of aortic regurgitation after transcatheter aortic valve replacement: meta-analysis and systematic review of literature. J Am Coll Cardiol. 2013;61:1585–95. A meta-analysis to report predictors of paravalvular regurgitation being mostly the Agatson calcium score by MSCT, valve undersizing and the depth of implantation.PubMedCrossRef Athappan G, Patvardhan E, Tuzcu EM, Svensson LG, Lemos PA, Fraccaro C. Incidence, predictors, and outcomes of aortic regurgitation after transcatheter aortic valve replacement: meta-analysis and systematic review of literature. J Am Coll Cardiol. 2013;61:1585–95. A meta-analysis to report predictors of paravalvular regurgitation being mostly the Agatson calcium score by MSCT, valve undersizing and the depth of implantation.PubMedCrossRef
14.•
Zurück zum Zitat Smith LA, Monaghan MJ. Monitoring of procedures: peri-interventional echo assessment for transcatheter aortic valve implantation. Eur Heart J Cardiovasc Imaging. 2013;14(9):840–50. An excellent review to describe the procedural use of echocardiography and its added value in this procedure.PubMedCrossRef Smith LA, Monaghan MJ. Monitoring of procedures: peri-interventional echo assessment for transcatheter aortic valve implantation. Eur Heart J Cardiovasc Imaging. 2013;14(9):840–50. An excellent review to describe the procedural use of echocardiography and its added value in this procedure.PubMedCrossRef
15.
Zurück zum Zitat Jánosi RA, Kahlert P, Plicht B, Wendt D, Eggebrecht H, Erbel R, et al. Measurement of the aortic annulus size by real-time three-dimensional transesophageal echocardiography. Minim Invasive Ther. 2011;20:85–94.CrossRef Jánosi RA, Kahlert P, Plicht B, Wendt D, Eggebrecht H, Erbel R, et al. Measurement of the aortic annulus size by real-time three-dimensional transesophageal echocardiography. Minim Invasive Ther. 2011;20:85–94.CrossRef
16.
Zurück zum Zitat Jabbour A, Ismail TF, Moat N, Gulati A, Roussin I, Alpendurada F, et al. Multimodality imaging in transcatheter aortic valve implantation and post-procedural aortic regurgitation: comparison among cardiovascular magnetic resonance, cardiac computed tomography, and echocardiography. J Am Coll Cardiol. 2011;58:2165–73.PubMedCrossRef Jabbour A, Ismail TF, Moat N, Gulati A, Roussin I, Alpendurada F, et al. Multimodality imaging in transcatheter aortic valve implantation and post-procedural aortic regurgitation: comparison among cardiovascular magnetic resonance, cardiac computed tomography, and echocardiography. J Am Coll Cardiol. 2011;58:2165–73.PubMedCrossRef
17.
Zurück zum Zitat Gurvtich R, Webb JG, Yuan R, Johnson M, Hague C, Willson AB, et al. Aortic annulus diameter determination by multidetector computed tomography: reproducibility, applicability and implications for transcatheter aortic valve implantation. J Am Coll Cardiol Intv. 2011;4(11):1235–45.CrossRef Gurvtich R, Webb JG, Yuan R, Johnson M, Hague C, Willson AB, et al. Aortic annulus diameter determination by multidetector computed tomography: reproducibility, applicability and implications for transcatheter aortic valve implantation. J Am Coll Cardiol Intv. 2011;4(11):1235–45.CrossRef
18.
Zurück zum Zitat Jilaihawi H, Kashif M, Fontana G, Furugen A, Shiota T, Friede G, et al. Cross-sectional computed tomographic assessment improves accuracy of aortic annular sizing for transcatheter aortic valve replacement and reduces the incidence of paravalvular aortic regurgitation. J Am Coll Cardiol. 2012;59(14):1275–86.PubMedCrossRef Jilaihawi H, Kashif M, Fontana G, Furugen A, Shiota T, Friede G, et al. Cross-sectional computed tomographic assessment improves accuracy of aortic annular sizing for transcatheter aortic valve replacement and reduces the incidence of paravalvular aortic regurgitation. J Am Coll Cardiol. 2012;59(14):1275–86.PubMedCrossRef
19.
Zurück zum Zitat Watanabe Y, Morice MC, Bouvier E, Leong T, Hayashida K, Lefèvre T, et al. Automated 3-dimensional aortic annular assessment by multidetector computed tomography in transcatheter aortic valve implantation. J Am Coll Cardiol Intv. 2013;6(9):955–64.CrossRef Watanabe Y, Morice MC, Bouvier E, Leong T, Hayashida K, Lefèvre T, et al. Automated 3-dimensional aortic annular assessment by multidetector computed tomography in transcatheter aortic valve implantation. J Am Coll Cardiol Intv. 2013;6(9):955–64.CrossRef
20.
Zurück zum Zitat Altiok E, Koos R, Schroder J, Brehmer K, Hamada S, Becker M, et al. Comparison of two-dimensional and three-dimensional imaging techniques for measurement of aortic annulus diameters before transcatheter aortic valve implantation. Heart. 2011;91(19):1578–84.CrossRef Altiok E, Koos R, Schroder J, Brehmer K, Hamada S, Becker M, et al. Comparison of two-dimensional and three-dimensional imaging techniques for measurement of aortic annulus diameters before transcatheter aortic valve implantation. Heart. 2011;91(19):1578–84.CrossRef
21.
Zurück zum Zitat Stortecky S, Heg D, Gloekler S, Wenaweser P, Windecker S, Buellesfeld L. Accuracy and reproducibility of aortic annulus sizing using a dedicated three-dimensional computed tomography reconstruction tool in patients evaluated for transcatheter aortic valve replacement. EuroIntervention. 2014;10(3):339–46.PubMedCrossRef Stortecky S, Heg D, Gloekler S, Wenaweser P, Windecker S, Buellesfeld L. Accuracy and reproducibility of aortic annulus sizing using a dedicated three-dimensional computed tomography reconstruction tool in patients evaluated for transcatheter aortic valve replacement. EuroIntervention. 2014;10(3):339–46.PubMedCrossRef
22.
Zurück zum Zitat Khalique OK, Kodali SK, Paradis JM, Nazif TM, Williams MR, Einstein AJ, et al. Aortic annular sizing using a novel 3-dimensional echocardiographic method: use and comparison with cardiac computed tomography. Circ Cardiovasc Imaging. 2014;7(1):155–63.PubMedCrossRef Khalique OK, Kodali SK, Paradis JM, Nazif TM, Williams MR, Einstein AJ, et al. Aortic annular sizing using a novel 3-dimensional echocardiographic method: use and comparison with cardiac computed tomography. Circ Cardiovasc Imaging. 2014;7(1):155–63.PubMedCrossRef
23.
Zurück zum Zitat Santos N, de Agustin JA, Almeria C, Goncalves A, Marcos-Alberca P, Fernandez-Golfin C, et al. Prosthesis/annulus discongruence assessed by three-dimensional transesophageal echocardiography: a predictor of significant para valvular aortic regurgitation after transcatheter aortic valve implantation. Eur Heart J Cardiovasc Imaging. 2012;13:931–7.PubMedCrossRef Santos N, de Agustin JA, Almeria C, Goncalves A, Marcos-Alberca P, Fernandez-Golfin C, et al. Prosthesis/annulus discongruence assessed by three-dimensional transesophageal echocardiography: a predictor of significant para valvular aortic regurgitation after transcatheter aortic valve implantation. Eur Heart J Cardiovasc Imaging. 2012;13:931–7.PubMedCrossRef
24.
Zurück zum Zitat Hahn T, Khalique O, Williams MR, et al. Predicting paravalvular regurgitation following transcatheter valve replacement: utility of a novel method for three-dimensional echocardiographic measurement of the aortic annulus. J Am Soc Echocardiogr. 2013;26:144–52. Hahn T, Khalique O, Williams MR, et al. Predicting paravalvular regurgitation following transcatheter valve replacement: utility of a novel method for three-dimensional echocardiographic measurement of the aortic annulus. J Am Soc Echocardiogr. 2013;26:144–52.
25.
Zurück zum Zitat Thilo C, Shivaraju A, von Scheidt W, Kasel AM. Bicuspid aortic valve stenosis with successful transfemoral transcatheter aortic valve replacement (TAVI) using the Sapien 3 valve. Eur Heart J. 2014;35(38):2662.PubMedCrossRef Thilo C, Shivaraju A, von Scheidt W, Kasel AM. Bicuspid aortic valve stenosis with successful transfemoral transcatheter aortic valve replacement (TAVI) using the Sapien 3 valve. Eur Heart J. 2014;35(38):2662.PubMedCrossRef
26.
Zurück zum Zitat Costopoulos C, Latib A, Maisano F, Testa L, Bedogni F, Buchanan L, et al. Comparison of results of transcatheter aortic valve implantation in patients with severely stenotic bicuspid versus tricuspid or nonbicuspid valves. Am J Cardiol. 2014;113(8):1390–3.PubMedCrossRef Costopoulos C, Latib A, Maisano F, Testa L, Bedogni F, Buchanan L, et al. Comparison of results of transcatheter aortic valve implantation in patients with severely stenotic bicuspid versus tricuspid or nonbicuspid valves. Am J Cardiol. 2014;113(8):1390–3.PubMedCrossRef
27.
Zurück zum Zitat Ewe SH, Ng AC, Schuijf JD, van der Kley F, Colli A, Palmen M, et al. Location and severity of aortic valve calcium and implications for aortic regurgitation after transcatheter aortic valve implantation. Am J Cardiol. 2011;108:1470–7.PubMedCrossRef Ewe SH, Ng AC, Schuijf JD, van der Kley F, Colli A, Palmen M, et al. Location and severity of aortic valve calcium and implications for aortic regurgitation after transcatheter aortic valve implantation. Am J Cardiol. 2011;108:1470–7.PubMedCrossRef
28.
Zurück zum Zitat Haensig M, Lehmkuhl L, Rastan AJ, Kempfert J, Mukherjee C, Gutberlet M, et al. Aortic valve calcium scoring is a predictor of significant paravalvular aortic insufficiency in transapical-aortic valve implantation. Eur J Cardiothorac Surg. 2012;41:1234–40.PubMedCrossRef Haensig M, Lehmkuhl L, Rastan AJ, Kempfert J, Mukherjee C, Gutberlet M, et al. Aortic valve calcium scoring is a predictor of significant paravalvular aortic insufficiency in transapical-aortic valve implantation. Eur J Cardiothorac Surg. 2012;41:1234–40.PubMedCrossRef
29.
Zurück zum Zitat Ribeiro HB, Nombela-Franco L, Urena M, Mok M, Pasian S, Doyle D, et al. Coronary obstruction following transcatheter aortic valve implantation: a systematic review. J Am Coll Cardiol Intv. 2013;6(5):452–61.CrossRef Ribeiro HB, Nombela-Franco L, Urena M, Mok M, Pasian S, Doyle D, et al. Coronary obstruction following transcatheter aortic valve implantation: a systematic review. J Am Coll Cardiol Intv. 2013;6(5):452–61.CrossRef
30.
Zurück zum Zitat Jánosi RA, Plicht B, Kahlert P, Eißmann M, Wendt D, Jakob H, et al. Quantitative analysis of aortic valve stenosis and aortic root dimensions by three-dimensional echocardiography in patients scheduled for transcutaneous aortic valve implantation. Curr Cardiovasc Img Rep. 2014;7:9296.CrossRef Jánosi RA, Plicht B, Kahlert P, Eißmann M, Wendt D, Jakob H, et al. Quantitative analysis of aortic valve stenosis and aortic root dimensions by three-dimensional echocardiography in patients scheduled for transcutaneous aortic valve implantation. Curr Cardiovasc Img Rep. 2014;7:9296.CrossRef
31.
Zurück zum Zitat Barbanti M, Yang TH, Rodes-Cbau J, Tamburin C, Jilaihawi H, et al. Anatomical and procedural features associated with aortic root rupture during balloon expandable transcatheter aortic valve replacement. Circulation. 2013;128(3):244–53.PubMedCrossRef Barbanti M, Yang TH, Rodes-Cbau J, Tamburin C, Jilaihawi H, et al. Anatomical and procedural features associated with aortic root rupture during balloon expandable transcatheter aortic valve replacement. Circulation. 2013;128(3):244–53.PubMedCrossRef
32.
Zurück zum Zitat Masson JB, Kovac J, Schuler G, Ye J, Cheung A, Kapadia S, et al. Transcatheter aortic valve implantation: review of the nature, management and avoidance of procedural complications. J Am Coll Cardiol Intv. 2009;2(9):811–20.CrossRef Masson JB, Kovac J, Schuler G, Ye J, Cheung A, Kapadia S, et al. Transcatheter aortic valve implantation: review of the nature, management and avoidance of procedural complications. J Am Coll Cardiol Intv. 2009;2(9):811–20.CrossRef
33.
Zurück zum Zitat Holmes Jr DR, Mack MJ, Kaul S, Agnihotri A, Alexander KP, Bailey SR, et al. 2012 ACCF/AATS/SCAI/STS expert consensus document on transcatheter aortic valve replacement. J Am Coll Cardiol. 2012;59(2):249–62. Holmes Jr DR, Mack MJ, Kaul S, Agnihotri A, Alexander KP, Bailey SR, et al. 2012 ACCF/AATS/SCAI/STS expert consensus document on transcatheter aortic valve replacement. J Am Coll Cardiol. 2012;59(2):249–62.
34.•
Zurück zum Zitat Zamorano JL, Gonçalves A, Lang R. Imaging to select and guide transcatheter aortic valve implantation. Eur Heart J. 2014;35:1578–87. The use of multimodality imaging in percutaneous valve interventions is described in detail in this review.PubMedCentralPubMedCrossRef Zamorano JL, Gonçalves A, Lang R. Imaging to select and guide transcatheter aortic valve implantation. Eur Heart J. 2014;35:1578–87. The use of multimodality imaging in percutaneous valve interventions is described in detail in this review.PubMedCentralPubMedCrossRef
35.
Zurück zum Zitat Shibayama K, Harada K, Berdejo J, Mihara H, Tanaka J, Gurudevan SV, et al. Effect of transcatheter aortic valve replacement on the mitral valve apparatus and mitral regurgitation: real-time three-dimensional transesophageal echocardiography study. Circ Cardiovasc Imaging. 2014;7(2):344–51.PubMedCrossRef Shibayama K, Harada K, Berdejo J, Mihara H, Tanaka J, Gurudevan SV, et al. Effect of transcatheter aortic valve replacement on the mitral valve apparatus and mitral regurgitation: real-time three-dimensional transesophageal echocardiography study. Circ Cardiovasc Imaging. 2014;7(2):344–51.PubMedCrossRef
36.
Zurück zum Zitat Lerakis S, Hayek SS, Douglas PS. Paravalvular aortic leak after transcatheter aortic valve replacement: current knowledge. Circulation. 2013;127(3):397–407.PubMedCrossRef Lerakis S, Hayek SS, Douglas PS. Paravalvular aortic leak after transcatheter aortic valve replacement: current knowledge. Circulation. 2013;127(3):397–407.PubMedCrossRef
37.
Zurück zum Zitat Hong SJ, Hong MK, Ko YG, Hong GR, Shim JK, Kwak YL, et al. Migration of calcium and atheromatous plaque in computed tomography: an important mechanism of coronary artery occlusion after transcatheter aortic valve replacement. J Am Coll Cardiol. 2014;63(12):e23.PubMedCrossRef Hong SJ, Hong MK, Ko YG, Hong GR, Shim JK, Kwak YL, et al. Migration of calcium and atheromatous plaque in computed tomography: an important mechanism of coronary artery occlusion after transcatheter aortic valve replacement. J Am Coll Cardiol. 2014;63(12):e23.PubMedCrossRef
38.
Zurück zum Zitat Ribeiro HB, Webb JG, Makkar RR, Cohen MG, Kapadia SR, Kodali S, et al. Predictive factors, management, and clinical outcomes of coronary obstruction following transcatheter aortic valve implantation: insights from a large multicentre registry. J Am Coll Cardiol. 2013;62(17):1552–62.PubMedCrossRef Ribeiro HB, Webb JG, Makkar RR, Cohen MG, Kapadia SR, Kodali S, et al. Predictive factors, management, and clinical outcomes of coronary obstruction following transcatheter aortic valve implantation: insights from a large multicentre registry. J Am Coll Cardiol. 2013;62(17):1552–62.PubMedCrossRef
39.
Zurück zum Zitat Griese DP, Reents W, Kerber S, Diegeler A, Babin-Ebell J. Emergent cardiac surgery during transfemoral and transapical transcatheter aortic valve implantation: incidence, reasons, management and outcome of 411 patients from a single center. Catheter Cardiovasc Interv. 2013;82(5):E726–33.PubMedCrossRef Griese DP, Reents W, Kerber S, Diegeler A, Babin-Ebell J. Emergent cardiac surgery during transfemoral and transapical transcatheter aortic valve implantation: incidence, reasons, management and outcome of 411 patients from a single center. Catheter Cardiovasc Interv. 2013;82(5):E726–33.PubMedCrossRef
40.
Zurück zum Zitat Eggebrecht H, Schmermund A, Kahlert P, Erbel R, Voigtlander T, Mehta RH. Emergent cardiac surgery during transcatheter aortic implantation (TAVI): a weighted meta-analysis of 9251 patients from 46 studies. Eurointervention. 2013;8(9):1072–80.PubMedCrossRef Eggebrecht H, Schmermund A, Kahlert P, Erbel R, Voigtlander T, Mehta RH. Emergent cardiac surgery during transcatheter aortic implantation (TAVI): a weighted meta-analysis of 9251 patients from 46 studies. Eurointervention. 2013;8(9):1072–80.PubMedCrossRef
41.
Zurück zum Zitat Zoghbi WA, Chambers JB, Dumesnil JG, Foster E, Gottdiener JS, Grayburn PA, et al. Recommendations for evaluation of prosthetic valves with echocardiography and Doppler ultrasound: a report from the American Society of Echocardiography’s Guidelines and Standards Committee and the Task Force on Prosthetic Valves, developed in conjunction with the American College of Cardiology Cardiovascular Imaging Committee, Cardiac Imaging Committee of the American Heart Association, the European Association of Echocardiography, a registered branch of the European Society of Cardiology, the Japanese Society of Echocardiography and the Canadian Society of Echocardiography, endorsed by the American College of Cardiology Foundation, American Heart Association, European Association of Echocardiography, a registered branch of the European Society Of Cardiology, the Japanese Society of Echocardiography, and Canadian Society of Echocardiography. J Am Soc Echocardiogr. 2009;22(9):975–1014.PubMedCrossRef Zoghbi WA, Chambers JB, Dumesnil JG, Foster E, Gottdiener JS, Grayburn PA, et al. Recommendations for evaluation of prosthetic valves with echocardiography and Doppler ultrasound: a report from the American Society of Echocardiography’s Guidelines and Standards Committee and the Task Force on Prosthetic Valves, developed in conjunction with the American College of Cardiology Cardiovascular Imaging Committee, Cardiac Imaging Committee of the American Heart Association, the European Association of Echocardiography, a registered branch of the European Society of Cardiology, the Japanese Society of Echocardiography and the Canadian Society of Echocardiography, endorsed by the American College of Cardiology Foundation, American Heart Association, European Association of Echocardiography, a registered branch of the European Society Of Cardiology, the Japanese Society of Echocardiography, and Canadian Society of Echocardiography. J Am Soc Echocardiogr. 2009;22(9):975–1014.PubMedCrossRef
42.•
Zurück zum Zitat Goncalves A, Almeria C, Marcos-Alberca P, Feltes G, Hernandez-Antolin R, Rodriguez E, et al. Three-dimensional echocardiography in paravalvular aortic regurgitation assessment after transcatheter aortic valve implantation. J Am Soc Echocardiogr. 2012;25:47–55. This paper describes the incremental value of three-dimensional echocardiography in assessment of paravalvular regurgitation.PubMedCrossRef Goncalves A, Almeria C, Marcos-Alberca P, Feltes G, Hernandez-Antolin R, Rodriguez E, et al. Three-dimensional echocardiography in paravalvular aortic regurgitation assessment after transcatheter aortic valve implantation. J Am Soc Echocardiogr. 2012;25:47–55. This paper describes the incremental value of three-dimensional echocardiography in assessment of paravalvular regurgitation.PubMedCrossRef
43.
Zurück zum Zitat Sinning JM, Vasa-Nicotera M, Chin D, Hammerstingl C, Ghanem A, Bence J, et al. Evaluation and management of paravalvular aortic regurgitation after transcatheter aortic valve replacement. J Am Coll Cardiol. 2013;62(1):11–20.PubMedCrossRef Sinning JM, Vasa-Nicotera M, Chin D, Hammerstingl C, Ghanem A, Bence J, et al. Evaluation and management of paravalvular aortic regurgitation after transcatheter aortic valve replacement. J Am Coll Cardiol. 2013;62(1):11–20.PubMedCrossRef
44.
Zurück zum Zitat Kappetein AP, Head SJ, Généreux P, Piazza N, van Mieghem NM, Blackstone EH, et al. Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document (VARC-2). Eur J Cardiothorac Surg. 2012;42(5):S45–60.PubMedCrossRef Kappetein AP, Head SJ, Généreux P, Piazza N, van Mieghem NM, Blackstone EH, et al. Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document (VARC-2). Eur J Cardiothorac Surg. 2012;42(5):S45–60.PubMedCrossRef
45.
Zurück zum Zitat Lang RM, Badano LP, Tsang W, Adams DH, Agricola E, Buck T, et al. EAE/ASE recommendations for image acquisition and display using three-dimensional echocardiography. Eur Heart J Cardiovasc Imaging. 2012;13(1):1–46.PubMedCrossRef Lang RM, Badano LP, Tsang W, Adams DH, Agricola E, Buck T, et al. EAE/ASE recommendations for image acquisition and display using three-dimensional echocardiography. Eur Heart J Cardiovasc Imaging. 2012;13(1):1–46.PubMedCrossRef
46.•
Zurück zum Zitat Genereux P, Head SJ, Hahn R, Daneault B, Odali S, Williams MR, et al. Paravalvular leak after transcatheter aortic valve replacement: the new Achilles’ heel: a comprehensive review of the literature. J Am Coll Cardiol. 2013;61(11):1125–36. This paper resumes the evidence provided by current literature on paravalvular regurgitation.PubMedCrossRef Genereux P, Head SJ, Hahn R, Daneault B, Odali S, Williams MR, et al. Paravalvular leak after transcatheter aortic valve replacement: the new Achilles’ heel: a comprehensive review of the literature. J Am Coll Cardiol. 2013;61(11):1125–36. This paper resumes the evidence provided by current literature on paravalvular regurgitation.PubMedCrossRef
47.
Zurück zum Zitat Nombela-Franco L, Rodes-Cabau J, DeLarochelliere R, Larose E, Doyle D, Villeneuve J, et al. Predictive factors, efficacy and safety of balloon post-dilatation after transcatheter aortic valve implantation with a balloon-expandable valve. J Am Coll Cardiol Intv. 2012;5:499–512.CrossRef Nombela-Franco L, Rodes-Cabau J, DeLarochelliere R, Larose E, Doyle D, Villeneuve J, et al. Predictive factors, efficacy and safety of balloon post-dilatation after transcatheter aortic valve implantation with a balloon-expandable valve. J Am Coll Cardiol Intv. 2012;5:499–512.CrossRef
48.
Zurück zum Zitat Nietlispach F, Maisano F. Balloon post-dilation after transcatheter aortic valve replacement: a solution worth trying in patients with residual aortic insufficiency. J Am Coll Cardiol Intv. 2014;7(7):790–1.CrossRef Nietlispach F, Maisano F. Balloon post-dilation after transcatheter aortic valve replacement: a solution worth trying in patients with residual aortic insufficiency. J Am Coll Cardiol Intv. 2014;7(7):790–1.CrossRef
49.
Zurück zum Zitat Daneault B, Koss E, Hahn RT, Kodali S, Williams MR, Genereux P, et al. Efficacy and safety of postdilatation to reduce paravalvular regurgitation during balloon-expandable transcatheter aortic valve replacement. Circ Cardiovasc Interv. 2013;6(1):85–91.PubMedCrossRef Daneault B, Koss E, Hahn RT, Kodali S, Williams MR, Genereux P, et al. Efficacy and safety of postdilatation to reduce paravalvular regurgitation during balloon-expandable transcatheter aortic valve replacement. Circ Cardiovasc Interv. 2013;6(1):85–91.PubMedCrossRef
50.
Zurück zum Zitat Inoue K. Percutaneous transvenous mitral commissurotomy using the Inoue balloon. Eur Heart J. 1991;99(Suppl B):99–108.CrossRef Inoue K. Percutaneous transvenous mitral commissurotomy using the Inoue balloon. Eur Heart J. 1991;99(Suppl B):99–108.CrossRef
51.
Zurück zum Zitat Wilkins GT, Weyman AE, Abascal VM, Block PC, Palacios IF. Percutaneous balloon dilatation of the mitral valve: an analysis of echocardiographic variables related to outcome and the mechanism of dilatation. Br Heart J. 1988;60(4):299–308.PubMedCentralPubMedCrossRef Wilkins GT, Weyman AE, Abascal VM, Block PC, Palacios IF. Percutaneous balloon dilatation of the mitral valve: an analysis of echocardiographic variables related to outcome and the mechanism of dilatation. Br Heart J. 1988;60(4):299–308.PubMedCentralPubMedCrossRef
52.
Zurück zum Zitat Valocik G, Kamp O, Mannaerts HF, Visser CA. New quantitative three-dimensional echocardiographic indices of mitral valve stenosis. Int J Cardiovasc Imaging. 2007;23(6):707–16.PubMedCrossRef Valocik G, Kamp O, Mannaerts HF, Visser CA. New quantitative three-dimensional echocardiographic indices of mitral valve stenosis. Int J Cardiovasc Imaging. 2007;23(6):707–16.PubMedCrossRef
53.
Zurück zum Zitat Zamorano J, Cordeiro P, Sugeng L, et al. Real-time three-dimensional echocardiography for rheumatic mitral valve stenosis evaluation—an accurate and novel approach. J Am Coll Cardiol. 2004;43(11):2091–6.PubMedCrossRef Zamorano J, Cordeiro P, Sugeng L, et al. Real-time three-dimensional echocardiography for rheumatic mitral valve stenosis evaluation—an accurate and novel approach. J Am Coll Cardiol. 2004;43(11):2091–6.PubMedCrossRef
54.
Zurück zum Zitat Fatkin D, Roy P, Morgan JJ, Feneley MP. Percutaneous balloon mitral valvulotomy with the Inoue single-balloon catheter: commissural morphology as a determinant of outcome. J Am Coll Cardiol. 1993;21(2):390–7.PubMedCrossRef Fatkin D, Roy P, Morgan JJ, Feneley MP. Percutaneous balloon mitral valvulotomy with the Inoue single-balloon catheter: commissural morphology as a determinant of outcome. J Am Coll Cardiol. 1993;21(2):390–7.PubMedCrossRef
55.
Zurück zum Zitat Dreyfus J, Cimadevilla C, Nguyen V, Brochet E, Lepage L, Himbert D, et al. Feasibility of percutaneous mitral commissurotomy in patients with commissural mitral valve calcification. Eur Heart J. 2014;35(24):1617–23.PubMedCrossRef Dreyfus J, Cimadevilla C, Nguyen V, Brochet E, Lepage L, Himbert D, et al. Feasibility of percutaneous mitral commissurotomy in patients with commissural mitral valve calcification. Eur Heart J. 2014;35(24):1617–23.PubMedCrossRef
56.
Zurück zum Zitat White ML, Grover-McKay M, Weiss RM, et al. Prediction of change in mitral valve area after mitral balloon commissurotomy using cine computed tomography. Investig Radiol. 1994;29(9):827–33.CrossRef White ML, Grover-McKay M, Weiss RM, et al. Prediction of change in mitral valve area after mitral balloon commissurotomy using cine computed tomography. Investig Radiol. 1994;29(9):827–33.CrossRef
57.
Zurück zum Zitat Zamorano J, Perez de Isla L, Sugeng L, et al. Non-invasive assessment of mitral valve area during percutaneous balloon mitral valvuloplasty: role of real-time 3D echocardiography. Eur Heart J. 2004;25(23):2086–91.PubMedCrossRef Zamorano J, Perez de Isla L, Sugeng L, et al. Non-invasive assessment of mitral valve area during percutaneous balloon mitral valvuloplasty: role of real-time 3D echocardiography. Eur Heart J. 2004;25(23):2086–91.PubMedCrossRef
58.
Zurück zum Zitat Applebaum RM, Kasliwal RR, Kanojia A, et al. Utility of three-dimensional echocardiography during balloon mitral valvuloplasty. J Am Coll Cardiol. 1998;32:1405–9.PubMedCrossRef Applebaum RM, Kasliwal RR, Kanojia A, et al. Utility of three-dimensional echocardiography during balloon mitral valvuloplasty. J Am Coll Cardiol. 1998;32:1405–9.PubMedCrossRef
59.
Zurück zum Zitat Lee S-P, Kim H-K, Kim K-H, Kim J-H, et al. Prevalence of significant tricuspid regurgitation in patients with successful percutaneous mitral valvuloplasty for mitral stenosis: results from 12 years’ follow-up of one centre prospective registry. Heart. 2013;99:91–7.PubMedCrossRef Lee S-P, Kim H-K, Kim K-H, Kim J-H, et al. Prevalence of significant tricuspid regurgitation in patients with successful percutaneous mitral valvuloplasty for mitral stenosis: results from 12 years’ follow-up of one centre prospective registry. Heart. 2013;99:91–7.PubMedCrossRef
60.
Zurück zum Zitat Feldman T, Kar S, Rinaldi M, et al. Percutaneous mitral repair with the MitraClip system: safety and midterm durability in the initial EVEREST (Endovascular Valve Edge-to-Edge REpair Study) cohort. J Am Coll Cardiol. 2009;54:686–94.PubMedCrossRef Feldman T, Kar S, Rinaldi M, et al. Percutaneous mitral repair with the MitraClip system: safety and midterm durability in the initial EVEREST (Endovascular Valve Edge-to-Edge REpair Study) cohort. J Am Coll Cardiol. 2009;54:686–94.PubMedCrossRef
61.
Zurück zum Zitat Feldman T, Foster E, Glower DG, et al. Percutaneous repair or surgery for mitral regurgitation. N Engl J Med. 2011;364:1395–406.PubMedCrossRef Feldman T, Foster E, Glower DG, et al. Percutaneous repair or surgery for mitral regurgitation. N Engl J Med. 2011;364:1395–406.PubMedCrossRef
62.
Zurück zum Zitat Munkholm-Larsen S, Wan B, Tian DH, Kearney K, Rahnavardi M, Dixen U, et al. A systematic review on the safety and efficacy of percutaneous edge-to-edge mitral valve repair with the MitraClip system for high surgical risk candidates. Heart. 2014;100(6):473–8.PubMedCrossRef Munkholm-Larsen S, Wan B, Tian DH, Kearney K, Rahnavardi M, Dixen U, et al. A systematic review on the safety and efficacy of percutaneous edge-to-edge mitral valve repair with the MitraClip system for high surgical risk candidates. Heart. 2014;100(6):473–8.PubMedCrossRef
63.
Zurück zum Zitat Wan B, Rahnavardi M, Tian DH, Phan K, Munkholm-Larsen S, Bannon PG, et al. A meta-analysis of MitraClip system versus surgery for treatment of severe mitral regurgitation. Ann Cardiothorac Surg. 2013;2(6):683–92.PubMedCentralPubMed Wan B, Rahnavardi M, Tian DH, Phan K, Munkholm-Larsen S, Bannon PG, et al. A meta-analysis of MitraClip system versus surgery for treatment of severe mitral regurgitation. Ann Cardiothorac Surg. 2013;2(6):683–92.PubMedCentralPubMed
64.
Zurück zum Zitat Alfieri O, De Bonis M. The role of edge-to-edge repair in the surgical treatment of mitral regurgitation. J Card Surg. 2010;25(5):536–41.PubMedCrossRef Alfieri O, De Bonis M. The role of edge-to-edge repair in the surgical treatment of mitral regurgitation. J Card Surg. 2010;25(5):536–41.PubMedCrossRef
65.
Zurück zum Zitat Wunderlich NC, Siegel RJ. Peri-interventional echo assessment for the MitraClip procedure. Eur Heart J Cardiovasc Imaging. 2013;14(10):935–49.PubMedCrossRef Wunderlich NC, Siegel RJ. Peri-interventional echo assessment for the MitraClip procedure. Eur Heart J Cardiovasc Imaging. 2013;14(10):935–49.PubMedCrossRef
66.
Zurück zum Zitat Quaife RA, Salcedo EE, Carroll JD. Procedural guidance using advance imaging techniques for percutaneous edge-to-edge mitral valve repair. Curr Cardiol Rep. 2014;16(2):452.PubMedCrossRef Quaife RA, Salcedo EE, Carroll JD. Procedural guidance using advance imaging techniques for percutaneous edge-to-edge mitral valve repair. Curr Cardiol Rep. 2014;16(2):452.PubMedCrossRef
67.
Zurück zum Zitat Jain S, Malouf JF. Incremental value of 3-D transesophageal echocardiographic imaging of the mitral valve. Curr Cardiol Rep. 2014;16(1):439.PubMedCrossRef Jain S, Malouf JF. Incremental value of 3-D transesophageal echocardiographic imaging of the mitral valve. Curr Cardiol Rep. 2014;16(1):439.PubMedCrossRef
68.
Zurück zum Zitat Lancellotti P, Moura L, Pierard LA, et al. European Association of Echocardiography recommendations for the assessment of valvular regurgitation. Part 2: mitral and tricuspid regurgitation (native valve disease). Eur J Echocardiogr. 2010;11:307–32.PubMedCrossRef Lancellotti P, Moura L, Pierard LA, et al. European Association of Echocardiography recommendations for the assessment of valvular regurgitation. Part 2: mitral and tricuspid regurgitation (native valve disease). Eur J Echocardiogr. 2010;11:307–32.PubMedCrossRef
69.
Zurück zum Zitat Biner S, Rafique A, Rafii G, Tolstrup K, Noorani O, Shiota T. Reproducibility of proximal isovelocity surface area, vena contracta and regurgitant jet area for assessment of mitral regurgitation severity. J Am Coll Cardiol Img. 2010;3:235–43.CrossRef Biner S, Rafique A, Rafii G, Tolstrup K, Noorani O, Shiota T. Reproducibility of proximal isovelocity surface area, vena contracta and regurgitant jet area for assessment of mitral regurgitation severity. J Am Coll Cardiol Img. 2010;3:235–43.CrossRef
70.
Zurück zum Zitat Kahlert P, Plicht B, Schenk IM, Janosi A, Erbel R, Buck T. Direct assessment of size and shape of non-circular vena contracta area in functional versus organic mitral regurgitation using real-time three-dimensional echocardiography. J Am Soc Echocardiogr. 2008;21(8):912–21.PubMedCrossRef Kahlert P, Plicht B, Schenk IM, Janosi A, Erbel R, Buck T. Direct assessment of size and shape of non-circular vena contracta area in functional versus organic mitral regurgitation using real-time three-dimensional echocardiography. J Am Soc Echocardiogr. 2008;21(8):912–21.PubMedCrossRef
71.
Zurück zum Zitat de Agustín JA, Marcos-Alberca P, Fernandez-Golfin C, Gonçalves A, Feltes G, Nuñez-Gil IJ, et al. Direct measurement of proximal isovelocity surface area by single-beat three-dimensional color Doppler echocardiography in mitral regurgitation: a validation study. J Am Soc Echocardiogr. 2012;25(8):815–23.PubMedCrossRef de Agustín JA, Marcos-Alberca P, Fernandez-Golfin C, Gonçalves A, Feltes G, Nuñez-Gil IJ, et al. Direct measurement of proximal isovelocity surface area by single-beat three-dimensional color Doppler echocardiography in mitral regurgitation: a validation study. J Am Soc Echocardiogr. 2012;25(8):815–23.PubMedCrossRef
72.
Zurück zum Zitat Faletra FF, Pedrazzini G, Pasotti E, Petrova I, Drasutiene A, Dequarti MC, et al. Role of real-time three dimensional transoesophageal echocardiography as guidance imaging modality during catheter based edge-to-edge mitral valve repair. Heart. 2013;99(16):1204–15.PubMedCrossRef Faletra FF, Pedrazzini G, Pasotti E, Petrova I, Drasutiene A, Dequarti MC, et al. Role of real-time three dimensional transoesophageal echocardiography as guidance imaging modality during catheter based edge-to-edge mitral valve repair. Heart. 2013;99(16):1204–15.PubMedCrossRef
73.
Zurück zum Zitat Biner S, Perk G, Kar S, Rafique AM, Slater J, Shiota T, et al. Utility of combined two-dimensional and three-dimensional transesophageal imaging for catheter-based mitral valve clip repair of mitral regurgitation. J Am Soc Echocardiogr. 2011;24(6):611–7.PubMedCrossRef Biner S, Perk G, Kar S, Rafique AM, Slater J, Shiota T, et al. Utility of combined two-dimensional and three-dimensional transesophageal imaging for catheter-based mitral valve clip repair of mitral regurgitation. J Am Soc Echocardiogr. 2011;24(6):611–7.PubMedCrossRef
74.
Zurück zum Zitat Carpentier A, Chauvaud S, Fabiani JN, Deloche A, Relland J, Lessana A, et al. Reconstructive surgery of mitral valve incompetence: ten-year appraisal. J Thorac Cardiovasc Surg. 1980;79:338–48.PubMed Carpentier A, Chauvaud S, Fabiani JN, Deloche A, Relland J, Lessana A, et al. Reconstructive surgery of mitral valve incompetence: ten-year appraisal. J Thorac Cardiovasc Surg. 1980;79:338–48.PubMed
75.
Zurück zum Zitat Paranskaya L, D’Ancona G, Bozdag-Turan I, Akin I, Kische S, Turan GR, et al. Percutaneous mitral valve repair with the MitraClip system: perioperative and 1-year follow-up results using standard or multiple clipping strategy. Catheter Cardiovasc Interv. 2013;81(7):1224–31.PubMedCrossRef Paranskaya L, D’Ancona G, Bozdag-Turan I, Akin I, Kische S, Turan GR, et al. Percutaneous mitral valve repair with the MitraClip system: perioperative and 1-year follow-up results using standard or multiple clipping strategy. Catheter Cardiovasc Interv. 2013;81(7):1224–31.PubMedCrossRef
76.
Zurück zum Zitat Altiok E, Hamada S, Brehmer K, et al. Analysis of procedural effects of percutaneous edge-to-edge mitral valve repair by 2D and 3D echocardiography. Circ Cardiovasc Imaging. 2012;5:748–55.PubMedCrossRef Altiok E, Hamada S, Brehmer K, et al. Analysis of procedural effects of percutaneous edge-to-edge mitral valve repair by 2D and 3D echocardiography. Circ Cardiovasc Imaging. 2012;5:748–55.PubMedCrossRef
77.
Zurück zum Zitat Zamorano JL, Badano LP, Bruce C, et al. EAE/ASE recommendations for the use of echocardiography in new transcatheter interventions for valvular heart disease. Eur J Echocardiogr. 2011;12:557–84.PubMedCrossRef Zamorano JL, Badano LP, Bruce C, et al. EAE/ASE recommendations for the use of echocardiography in new transcatheter interventions for valvular heart disease. Eur J Echocardiogr. 2011;12:557–84.PubMedCrossRef
78.
Zurück zum Zitat Ciobanu A, Bennett S, Azam M, Clark A, Vinereanu D. Incremental value of three-dimensional transoesophageal echocardiography for guiding double percutaneous MitraClip ® implantation in a ‘no option’ patient. Eur J Echocardiogr. 2011;12(2):E11.PubMedCrossRef Ciobanu A, Bennett S, Azam M, Clark A, Vinereanu D. Incremental value of three-dimensional transoesophageal echocardiography for guiding double percutaneous MitraClip ® implantation in a ‘no option’ patient. Eur J Echocardiogr. 2011;12(2):E11.PubMedCrossRef
79.
Zurück zum Zitat Lin BA, Forouhar AS, Pahlevan NM, Anastassiou CA, Grayburn PA, Thomas JD, et al. Color Doppler jet area overestimates regurgitant volume when multiple jets are present. J Am Soc Echocardiogr. 2010;23(9):993–1000.PubMedCrossRef Lin BA, Forouhar AS, Pahlevan NM, Anastassiou CA, Grayburn PA, Thomas JD, et al. Color Doppler jet area overestimates regurgitant volume when multiple jets are present. J Am Soc Echocardiogr. 2010;23(9):993–1000.PubMedCrossRef
80.
Zurück zum Zitat Blumlein S, Bouchard A, Schiller NB, Dae M, Byrd 3rd BF, Ports T, et al. Quantitation of mitral regurgitation by Doppler echocardiography. Circulation. 1986;74(2):306–14.PubMedCrossRef Blumlein S, Bouchard A, Schiller NB, Dae M, Byrd 3rd BF, Ports T, et al. Quantitation of mitral regurgitation by Doppler echocardiography. Circulation. 1986;74(2):306–14.PubMedCrossRef
81.
Zurück zum Zitat Buck T, Thiele KE. Basic principles and practical application. In: Buck T, Monaghan MJ, Franke A, editors. Three-dimensional echocardiography. 2nd ed. Heidelberg: Springer; 2015. Buck T, Thiele KE. Basic principles and practical application. In: Buck T, Monaghan MJ, Franke A, editors. Three-dimensional echocardiography. 2nd ed. Heidelberg: Springer; 2015.
82.
Zurück zum Zitat Faletra FF, Ramamurthi A, Dequarti MC, Leo LA, Moccetti T, Pandian N. Artifacts in three-dimensional transoesophageal echocardiography. J Am Soc Echocardiogr. 2014;27(5):453–62.PubMedCrossRef Faletra FF, Ramamurthi A, Dequarti MC, Leo LA, Moccetti T, Pandian N. Artifacts in three-dimensional transoesophageal echocardiography. J Am Soc Echocardiogr. 2014;27(5):453–62.PubMedCrossRef
83.
Zurück zum Zitat Gafoor S, Schulz P, Heuer L, Matic P, Franke J, Bertog S, et al. Use of EchoNavigator, a novel echocardiography-fluoroscopy overlay system, for transeptal puncture and left atrial appendage occlusion. J Interv Cardiol. 2015;28:215–7.PubMedCrossRef Gafoor S, Schulz P, Heuer L, Matic P, Franke J, Bertog S, et al. Use of EchoNavigator, a novel echocardiography-fluoroscopy overlay system, for transeptal puncture and left atrial appendage occlusion. J Interv Cardiol. 2015;28:215–7.PubMedCrossRef
84.
Zurück zum Zitat Sündermann SH, Biaggi P, Grünenfelder J, Gessat M, Felix C, Bettex D, et al. Safety and feasibility of novel technology fusing echocardiography and fluoroscopy images during MitraClip interventions. EuroIntervention. 2014;9(10):1210–6.PubMedCrossRef Sündermann SH, Biaggi P, Grünenfelder J, Gessat M, Felix C, Bettex D, et al. Safety and feasibility of novel technology fusing echocardiography and fluoroscopy images during MitraClip interventions. EuroIntervention. 2014;9(10):1210–6.PubMedCrossRef
85.
Zurück zum Zitat Ionescu A, Fraser AG, Butchart EG. Prevalence and clinical significance of incidental paraprosthetic valvular regurgitation: a prospective study using transoesophageal echocardiography. Heart. 2003;89:1316–21.PubMedCentralPubMedCrossRef Ionescu A, Fraser AG, Butchart EG. Prevalence and clinical significance of incidental paraprosthetic valvular regurgitation: a prospective study using transoesophageal echocardiography. Heart. 2003;89:1316–21.PubMedCentralPubMedCrossRef
86.
Zurück zum Zitat Defterios S, Giannopoulos G, Raisakis K, Kaoukis K, Kossyvakis C. Intracardiac echocardiography imaging of periprosthetic valvular regurgitation. Eur J Echocardiogr. 2010;11:E20.CrossRef Defterios S, Giannopoulos G, Raisakis K, Kaoukis K, Kossyvakis C. Intracardiac echocardiography imaging of periprosthetic valvular regurgitation. Eur J Echocardiogr. 2010;11:E20.CrossRef
87.
Zurück zum Zitat Taramasso M, Maisano F, Latib A, Denti P, Guidotti A, Sticchi A, et al. Conventional surgery and transcatheter closure via surgical transapical approach for paravalvular leak repair in high-risk patients: results from a single-centre experience. Eur Heart J Cardiovasc Imaging. 2014;15(10):1161–7.PubMedCrossRef Taramasso M, Maisano F, Latib A, Denti P, Guidotti A, Sticchi A, et al. Conventional surgery and transcatheter closure via surgical transapical approach for paravalvular leak repair in high-risk patients: results from a single-centre experience. Eur Heart J Cardiovasc Imaging. 2014;15(10):1161–7.PubMedCrossRef
88.
Zurück zum Zitat Nietlispach F, Johnson M, Moss RR, Wijesinghe N, Gurvitch R, Tay ELW, et al. Transcatheter closure of paravalvular defects using a purpose-specific occluder. J Am Coll Cardiol Intv. 2010;3:759–65.CrossRef Nietlispach F, Johnson M, Moss RR, Wijesinghe N, Gurvitch R, Tay ELW, et al. Transcatheter closure of paravalvular defects using a purpose-specific occluder. J Am Coll Cardiol Intv. 2010;3:759–65.CrossRef
89.••
Zurück zum Zitat Kliger C, Eiros R, Isasti G, et al. Review of surgical prosthetic paravalvular leaks: diagnosis and catheter-based closure. Eur Heart J. 2013;34:638–49. A technical approach to management of paravalvular leak closure with special description of imaging techniques and its use in these interventions.PubMedCrossRef Kliger C, Eiros R, Isasti G, et al. Review of surgical prosthetic paravalvular leaks: diagnosis and catheter-based closure. Eur Heart J. 2013;34:638–49. A technical approach to management of paravalvular leak closure with special description of imaging techniques and its use in these interventions.PubMedCrossRef
90.
Zurück zum Zitat Garcia-Fernandez MA, Cortes M, Garcia-Robles JA, Gomez de Diego JJ, Perez-David E, Garcia E. Utility of real-time three-dimensional transesophageal echocardiography in evaluating the success of percutaneous transcatheter closure of mitral paravalvular leaks. J Am Soc Echocardiogr. 2010;23:26–32.PubMedCrossRef Garcia-Fernandez MA, Cortes M, Garcia-Robles JA, Gomez de Diego JJ, Perez-David E, Garcia E. Utility of real-time three-dimensional transesophageal echocardiography in evaluating the success of percutaneous transcatheter closure of mitral paravalvular leaks. J Am Soc Echocardiogr. 2010;23:26–32.PubMedCrossRef
91.
Zurück zum Zitat Lázaro C, Hinojar R, Zamorano JL. Cardiac imaging in prosthetic paravalvular leaks. Cardiovasc Diagn Ther. 2014;4(4):307–13.PubMedCentralPubMed Lázaro C, Hinojar R, Zamorano JL. Cardiac imaging in prosthetic paravalvular leaks. Cardiovasc Diagn Ther. 2014;4(4):307–13.PubMedCentralPubMed
92.
Zurück zum Zitat Lesser JR, Han BK, Newell M, Schwartz RS, Pedersen W, Sorajja P. Use of cardiac CT angiography to assist in the diagnosis and treatment of aortic prosthetic paravalvular leak: a practical guide. J Cardiovasc Comput Tomogr. 2014;S1934-5925(14):00296–2. Lesser JR, Han BK, Newell M, Schwartz RS, Pedersen W, Sorajja P. Use of cardiac CT angiography to assist in the diagnosis and treatment of aortic prosthetic paravalvular leak: a practical guide. J Cardiovasc Comput Tomogr. 2014;S1934-5925(14):00296–2.
93.••
Zurück zum Zitat Pibarot P, Hahn RT, Weissman NJ, Monaghan MJ. Assessment of paravalvular regurgitation following TAVR: a proposal of unifying grading scheme. J Am Coll Cardiol Img. 2015;8(3):340–60. Recent expert consensus which proposed a new scheme to grade paravalvular regurgitation after TAVI describing the method and reasons to support the proposed grading scheme.CrossRef Pibarot P, Hahn RT, Weissman NJ, Monaghan MJ. Assessment of paravalvular regurgitation following TAVR: a proposal of unifying grading scheme. J Am Coll Cardiol Img. 2015;8(3):340–60. Recent expert consensus which proposed a new scheme to grade paravalvular regurgitation after TAVI describing the method and reasons to support the proposed grading scheme.CrossRef
94.
Zurück zum Zitat Kim MS, Casserly IP, Garcia JA, et al. Percutaneous transcatheter closure of prosthetic mitral paravalvular leaks: are we there yet? J Am Coll Cardiol Intv. 2009;2:81–90.CrossRef Kim MS, Casserly IP, Garcia JA, et al. Percutaneous transcatheter closure of prosthetic mitral paravalvular leaks: are we there yet? J Am Coll Cardiol Intv. 2009;2:81–90.CrossRef
95.
Zurück zum Zitat Becerra JM, Almeria C, de Isla LP, Zamorano J. Usefulness of 3D transoesophageal echocardiography for guiding wires and closure devices in mitral perivalvular leaks. Eur J Echocardiogr. 2009;10:979–81.PubMedCrossRef Becerra JM, Almeria C, de Isla LP, Zamorano J. Usefulness of 3D transoesophageal echocardiography for guiding wires and closure devices in mitral perivalvular leaks. Eur J Echocardiogr. 2009;10:979–81.PubMedCrossRef
96.
Zurück zum Zitat Biner S, Kar S, Siegel RJ, Rafique A, Shiota T. Value of color Doppler three-dimensional transesophageal echocardiography in the percutaneous closure of mitral prosthesis paravalvular leak. Am J Cardiol. 2010;105(7):984–9.PubMedCrossRef Biner S, Kar S, Siegel RJ, Rafique A, Shiota T. Value of color Doppler three-dimensional transesophageal echocardiography in the percutaneous closure of mitral prosthesis paravalvular leak. Am J Cardiol. 2010;105(7):984–9.PubMedCrossRef
97.
Zurück zum Zitat De Cicco G, Russo C, Moreo A, Beghi C, Fucci C, Gerometta P, et al. Mitral valve periprosthetic leakage: anatomical observations in 135 patients from a multicentre study. Eur J Cardiothorac Surg. 2006;30(6):887–91.PubMedCrossRef De Cicco G, Russo C, Moreo A, Beghi C, Fucci C, Gerometta P, et al. Mitral valve periprosthetic leakage: anatomical observations in 135 patients from a multicentre study. Eur J Cardiothorac Surg. 2006;30(6):887–91.PubMedCrossRef
98.
Zurück zum Zitat Franco E, Almería C, de Agustín JA, Arreo Del Val V, de Diego JJ G, García Fernández MA, et al. Three-dimensional color Doppler transesophageal echocardiography for mitral paravalvular leak quantification and evaluation of percutaneous closure success. J Am Soc Echocardiogr. 2014;27(11):1153–63.PubMedCrossRef Franco E, Almería C, de Agustín JA, Arreo Del Val V, de Diego JJ G, García Fernández MA, et al. Three-dimensional color Doppler transesophageal echocardiography for mitral paravalvular leak quantification and evaluation of percutaneous closure success. J Am Soc Echocardiogr. 2014;27(11):1153–63.PubMedCrossRef
99.
Zurück zum Zitat Ribeiro HB, Le Ven F, Larose E, Dahou A, Nombela-Franco L, Urena M, et al. Cardiac magnetic resonance versus transthoracic echocardiography for the assessment and quantification of aortic regurgitation in patients undergoing transcatheter aortic valve implantation. Heart. 2014;100(24):1924–32.PubMedCrossRef Ribeiro HB, Le Ven F, Larose E, Dahou A, Nombela-Franco L, Urena M, et al. Cardiac magnetic resonance versus transthoracic echocardiography for the assessment and quantification of aortic regurgitation in patients undergoing transcatheter aortic valve implantation. Heart. 2014;100(24):1924–32.PubMedCrossRef
100.
Zurück zum Zitat Orwat S, Diller GP, Kaleschke G, Kerckhoff G, Kempny A, Radke RM, et al. Aortic regurgitation severity after transcatheter aortic valve implantation is underestimated by echocardiography compared with MRI. Heart. 2014;100(24):1933–8.PubMedCrossRef Orwat S, Diller GP, Kaleschke G, Kerckhoff G, Kempny A, Radke RM, et al. Aortic regurgitation severity after transcatheter aortic valve implantation is underestimated by echocardiography compared with MRI. Heart. 2014;100(24):1933–8.PubMedCrossRef
101.
Zurück zum Zitat Kumar R, Jelnin V, Kliger C, et al. Percutaneous paravalvular leak closure. Cardiol Clin. 2013;31:431–40.PubMedCrossRef Kumar R, Jelnin V, Kliger C, et al. Percutaneous paravalvular leak closure. Cardiol Clin. 2013;31:431–40.PubMedCrossRef
102.
Zurück zum Zitat Altiok E, Frick M, Meyer CG, Al Ateah G, Napp A, Kirschfink A, et al. Comparison of two- and three-dimensional transthoracic echocardiography to cardiac magnetic resonance imaging for assessment of paravalvular regurgitation after transcatheter aortic valve implantation. Am J Cardiol. 2014;113(11):1859–66.PubMedCrossRef Altiok E, Frick M, Meyer CG, Al Ateah G, Napp A, Kirschfink A, et al. Comparison of two- and three-dimensional transthoracic echocardiography to cardiac magnetic resonance imaging for assessment of paravalvular regurgitation after transcatheter aortic valve implantation. Am J Cardiol. 2014;113(11):1859–66.PubMedCrossRef
103.
Zurück zum Zitat Thavendiranathan P, Liu S, Datta S, Walls M, Nitinunu A, Van Houten T, et al. Automated quantification of mitral inflow and aortic outflow stroke volumes by three-dimensional real-time volume color-flow Doppler transthoracic echocardiography: comparison with pulsed-wave Doppler and cardiac magnetic resonance imaging. J Am Soc Echocardiogr. 2012;25(1):56–65.PubMedCrossRef Thavendiranathan P, Liu S, Datta S, Walls M, Nitinunu A, Van Houten T, et al. Automated quantification of mitral inflow and aortic outflow stroke volumes by three-dimensional real-time volume color-flow Doppler transthoracic echocardiography: comparison with pulsed-wave Doppler and cardiac magnetic resonance imaging. J Am Soc Echocardiogr. 2012;25(1):56–65.PubMedCrossRef
104.
Zurück zum Zitat Cawley PJ, Hamilton-Craig C, Owens DS, Krieger EV, Strugnell WE, Mitsumori L, et al. Prospective comparison of valve regurgitation quantitation by cardiac magnetic resonance imaging and transthoracic echocardiography. Circ Cardiovasc Imaging. 2013;6(1):48–57.PubMedCrossRef Cawley PJ, Hamilton-Craig C, Owens DS, Krieger EV, Strugnell WE, Mitsumori L, et al. Prospective comparison of valve regurgitation quantitation by cardiac magnetic resonance imaging and transthoracic echocardiography. Circ Cardiovasc Imaging. 2013;6(1):48–57.PubMedCrossRef
105.
Zurück zum Zitat Merten C, Beurich HW, Zachow D, Mostafa AE, Geist V, Toelg R, et al. Aortic regurgitation and left ventricular remodeling after transcatheter aortic valve implantation: a serial cardiac magnetic resonance imaging study. Circ Cardiovasc Interv. 2013;6(4):476–83.PubMedCrossRef Merten C, Beurich HW, Zachow D, Mostafa AE, Geist V, Toelg R, et al. Aortic regurgitation and left ventricular remodeling after transcatheter aortic valve implantation: a serial cardiac magnetic resonance imaging study. Circ Cardiovasc Interv. 2013;6(4):476–83.PubMedCrossRef
106.
Zurück zum Zitat Bartel T, Müller S. Intraprocedural guidance: which imaging technique ranks highest and which one is complementary for closing paravalvular leaks? Cardiovasc Diagn Ther. 2014;4(4):277–8.PubMedCentralPubMed Bartel T, Müller S. Intraprocedural guidance: which imaging technique ranks highest and which one is complementary for closing paravalvular leaks? Cardiovasc Diagn Ther. 2014;4(4):277–8.PubMedCentralPubMed
107.
Zurück zum Zitat Bartel T, Müller S, Biviano A, Hahn RT. Why is intracardiac echocardiography helpful? Benefits, costs, and how to learn. Eur Heart J. 2014;35(2):69–76.PubMedCentralPubMedCrossRef Bartel T, Müller S, Biviano A, Hahn RT. Why is intracardiac echocardiography helpful? Benefits, costs, and how to learn. Eur Heart J. 2014;35(2):69–76.PubMedCentralPubMedCrossRef
108.
Zurück zum Zitat Rodríguez Muñoz D, Lázaro Rivera C, Zamorano Gómez JL. Guidance of treatment of perivalvular prosthetic leaks. Curr Cardiol Rep. 2014;16(1):430.PubMedCrossRef Rodríguez Muñoz D, Lázaro Rivera C, Zamorano Gómez JL. Guidance of treatment of perivalvular prosthetic leaks. Curr Cardiol Rep. 2014;16(1):430.PubMedCrossRef
Metadaten
Titel
Imaging During Percutaneous Valvular Heart DiseaseInterventions: Is More Better or Less?
verfasst von
Alejandra Carbonell San Román
José Luis Zamorano Gómez
Publikationsdatum
01.11.2015
Verlag
Springer US
Erschienen in
Current Cardiovascular Imaging Reports / Ausgabe 11/2015
Print ISSN: 1941-9066
Elektronische ISSN: 1941-9074
DOI
https://doi.org/10.1007/s12410-015-9359-4

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

Niedriger diastolischer Blutdruck erhöht Risiko für schwere kardiovaskuläre Komplikationen

25.04.2024 Hypotonie Nachrichten

Wenn unter einer medikamentösen Hochdrucktherapie der diastolische Blutdruck in den Keller geht, steigt das Risiko für schwere kardiovaskuläre Ereignisse: Darauf deutet eine Sekundäranalyse der SPRINT-Studie hin.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Adipositas-Medikament auch gegen Schlafapnoe wirksam

24.04.2024 Adipositas Nachrichten

Der als Antidiabetikum sowie zum Gewichtsmanagement zugelassene Wirkstoff Tirzepatid hat in Studien bei adipösen Patienten auch schlafbezogene Atmungsstörungen deutlich reduziert, informiert der Hersteller in einer Vorab-Meldung zum Studienausgang.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.