Skip to main content
Erschienen in: Pediatric Radiology 2/2005

01.02.2005 | Original Article

In vivo MRI measurement of blood oxygen saturation in children with congenital heart disease

verfasst von: Lynne E. Nield, Xiu-Ling L. Qi, Emanuela R. Valsangiacomo, Christopher K. Macgowan, Graham A. Wright, Lisa K. Hornberger, Shi-Joon Yoo

Erschienen in: Pediatric Radiology | Ausgabe 2/2005

Einloggen, um Zugang zu erhalten

Abstract

Objective: The purpose of this prospective study was to measure in vivo blood oxygen saturation (%O2) by MRI in children with congenital heart disease (CHD) using population-based values for T2O (T2 signal decay of fully oxygenated blood) and K (a parameter representing the deoxyhemoglobin effect) and compare the %O2 with direct cardiac catheterization measurements. Background: MRI can determine %O2 using in vivo measurement of signal decay (T2) and an in vitro calibration curve relating T2 and %O2, based on the equation: 1/T2=1/T2O+K(1−%O2/100)2. Recent studies have correlated the T2/%O2 in children with CHD with the adult calibration statistics. Methods: A total of ten children (five male, five female) with single ventricle CHD (median age 4.8 months, range 2 months to 4.4 years) undergoing cardiac catheterization were included in the study. The blood T2 measurements for each patient were performed in a 1.5 T GE CV scanner. The %O2 was then calculated based on the equation using values of T2O determined from individual hematocrits, and a population average value of K derived for children. The %O2 values were compared with direct %O2 measurements from cardiac catheterization. Results: The %O2 values by MRI were strongly correlated with direct cardiac catheterization measurements (R=0.825; P<0.001). Conclusion: The study indicates that the noninvasive measurement of %O2 by MRI can accurately measure oxygen saturation in children with complex CHD.
Literatur
1.
Zurück zum Zitat Vitiello R, McCrindle BW, Nykanen D, et al (1998) Complications associated with pediatric cardiac catheterization. J Am Coll Cardiol 32:1433–1440CrossRefPubMed Vitiello R, McCrindle BW, Nykanen D, et al (1998) Complications associated with pediatric cardiac catheterization. J Am Coll Cardiol 32:1433–1440CrossRefPubMed
2.
Zurück zum Zitat Wright GA, Hu BS, Macovski A (1991) Estimating oxygen saturation of blood in vivo with MR imaging at 1.5 T. J Magn Reson Imaging 1:275–283PubMed Wright GA, Hu BS, Macovski A (1991) Estimating oxygen saturation of blood in vivo with MR imaging at 1.5 T. J Magn Reson Imaging 1:275–283PubMed
3.
Zurück zum Zitat Li D, Waight DJ, Wang Y (1998) In vivo correlation between blood T2* and oxygen saturation. J Magn Reson Imaging 8:1236–1239PubMed Li D, Waight DJ, Wang Y (1998) In vivo correlation between blood T2* and oxygen saturation. J Magn Reson Imaging 8:1236–1239PubMed
4.
Zurück zum Zitat Li D, Wang Y, Waight DJ (1998) Blood oxygen saturation assessment in vivo using T2* estimation. Magn Reson Med 39:685–690PubMed Li D, Wang Y, Waight DJ (1998) Blood oxygen saturation assessment in vivo using T2* estimation. Magn Reson Med 39:685–690PubMed
5.
Zurück zum Zitat Thulborn KR, Radda GK (1981) Correlation of oxygen consumption with energy metabolism by in vivo NMR. J Cereb Blood Flow Metab 1:S82–S83 Thulborn KR, Radda GK (1981) Correlation of oxygen consumption with energy metabolism by in vivo NMR. J Cereb Blood Flow Metab 1:S82–S83
6.
Zurück zum Zitat Thulborn KR, Waterton JC, Mathews PM, et al (1982) Oxygenation dependence of the transverse relaxation time of water protons in whole blood at high field. Biochim Biophys Acta 714:265–270CrossRefPubMed Thulborn KR, Waterton JC, Mathews PM, et al (1982) Oxygenation dependence of the transverse relaxation time of water protons in whole blood at high field. Biochim Biophys Acta 714:265–270CrossRefPubMed
7.
Zurück zum Zitat Nield LE, Qi X, Yoo S-J, et al (2002) MRI-based blood oxygen saturation measurements in infants and children with congenital heart disease. Pediatr Radiol 32:518–522CrossRefPubMed Nield LE, Qi X, Yoo S-J, et al (2002) MRI-based blood oxygen saturation measurements in infants and children with congenital heart disease. Pediatr Radiol 32:518–522CrossRefPubMed
8.
Zurück zum Zitat Foltz WD, Merchant N, Downar E, et al (1999) Coronary venous oximetry using MRI. Magn Reson Med 42:837–848CrossRefPubMed Foltz WD, Merchant N, Downar E, et al (1999) Coronary venous oximetry using MRI. Magn Reson Med 42:837–848CrossRefPubMed
9.
Zurück zum Zitat Sachs T, Meyer CH, Irrarrazabal P, et al (1995) The diminishing variance algorithm for real-time reduction of motion artifacts in MRI. Magn Reson Med 34:412–422PubMed Sachs T, Meyer CH, Irrarrazabal P, et al (1995) The diminishing variance algorithm for real-time reduction of motion artifacts in MRI. Magn Reson Med 34:412–422PubMed
10.
Zurück zum Zitat Lin L (1989) A concordance correlation coefficient to evaluate reproducibility. Biometrics 45:255–268PubMed Lin L (1989) A concordance correlation coefficient to evaluate reproducibility. Biometrics 45:255–268PubMed
11.
Zurück zum Zitat Geva T, Vick GW III, Wendt RE, et al (1994) Role of spin echo and cine magnetic resonance imaging in presurgical planning of heterotaxy syndrome. Comparison with echocardiography and catheterization. Circulation 90:348–356PubMed Geva T, Vick GW III, Wendt RE, et al (1994) Role of spin echo and cine magnetic resonance imaging in presurgical planning of heterotaxy syndrome. Comparison with echocardiography and catheterization. Circulation 90:348–356PubMed
12.
Zurück zum Zitat Pederson EM, Stenbog EV, Frund T, et al (2002) Flow during exercise in the total cavopulmonary connection measured by magnetic resonance velocity mapping. Heart 87:554–558PubMed Pederson EM, Stenbog EV, Frund T, et al (2002) Flow during exercise in the total cavopulmonary connection measured by magnetic resonance velocity mapping. Heart 87:554–558PubMed
13.
Zurück zum Zitat Fogel MA, Hubbard A, Weinberg PM (2001) A simplified approach for assessment of intracardiac baffles and extracardiac conduits in congenital heart surgery with two- and three-dimensional magnetic resonance imaging. Am Heart J 142:1028–1036CrossRefPubMed Fogel MA, Hubbard A, Weinberg PM (2001) A simplified approach for assessment of intracardiac baffles and extracardiac conduits in congenital heart surgery with two- and three-dimensional magnetic resonance imaging. Am Heart J 142:1028–1036CrossRefPubMed
14.
Zurück zum Zitat Yoo SJ, Kim YM, Choe YH (1999) Magnetic resonance imaging of complex congenital heart disease. Int J Cardiovasc Imaging 15:151–160CrossRef Yoo SJ, Kim YM, Choe YH (1999) Magnetic resonance imaging of complex congenital heart disease. Int J Cardiovasc Imaging 15:151–160CrossRef
15.
Zurück zum Zitat Be’eri E, Maier SE, Landzberg MJ, et al (1998) In vivo evaluation of Fontan pathway flow dynamics by multidimensional phase-velocity magnetic resonance imaging. Circulation 98:2873–2882PubMed Be’eri E, Maier SE, Landzberg MJ, et al (1998) In vivo evaluation of Fontan pathway flow dynamics by multidimensional phase-velocity magnetic resonance imaging. Circulation 98:2873–2882PubMed
16.
Zurück zum Zitat Stainsby JA, Wright GA (1998) Partial volume effects on vascular T2 measurements. Magn Reson Med 40:494–499PubMed Stainsby JA, Wright GA (1998) Partial volume effects on vascular T2 measurements. Magn Reson Med 40:494–499PubMed
Metadaten
Titel
In vivo MRI measurement of blood oxygen saturation in children with congenital heart disease
verfasst von
Lynne E. Nield
Xiu-Ling L. Qi
Emanuela R. Valsangiacomo
Christopher K. Macgowan
Graham A. Wright
Lisa K. Hornberger
Shi-Joon Yoo
Publikationsdatum
01.02.2005
Erschienen in
Pediatric Radiology / Ausgabe 2/2005
Print ISSN: 0301-0449
Elektronische ISSN: 1432-1998
DOI
https://doi.org/10.1007/s00247-004-1305-6

Weitere Artikel der Ausgabe 2/2005

Pediatric Radiology 2/2005 Zur Ausgabe

Pediatric Radiology CME Activity

CME questions - February 2005

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.