Skip to main content
Erschienen in: Annals of Nuclear Medicine 8/2022

22.06.2022 | Original Article

Inferences of SPECT renal dynamic imaging injection quality based on lung and abdominal aorta imaging features

verfasst von: Jicheng Li, Lele Huang, Yongjun Luo, Kai Zhang, Jianyin Wang, Jianzhong Feng, Jiangyan Liu

Erschienen in: Annals of Nuclear Medicine | Ausgabe 8/2022

Einloggen, um Zugang zu erhalten

Abstract

Objective

To analyze the characteristics of blood flow perfusion images at different injection levels to establish an evaluation standard for renal dynamic imaging injection quality and reduce misdiagnosis.

Methods

Data from 140 single-photon emission computed tomography renal dynamic imaging, collected in our hospital, were retrospectively analyzed. The scans were divided into four groups according to the injection quality: total leakage of the imaging agent (group A), partial leakage (group B), poor bolus injection quality (group C), and good bolus injection quality (group D). The time of appearance and regression of the pulmonary blood perfusion phase, the peak time in the abdominal aorta, and the ratio between peak count and actual drug injection count were analyzed. The renal dynamic imaging was repeated in low-quality examinations, and the comparison between the two exams provided the misdiagnosis rate caused by inadequate injections.

Results

The images of the lungs and abdominal aorta in group A were blurred and indistinguishable; thus, these exams were unreliable. Both appearance and fading time of the bilateral lung shadows were significantly different between groups B, C, and D (p = 0.002 and p = 0.003, respectively). The peak time and peak counting ratio in the abdominal aorta were also significantly different between these groups (p = 0.002 and p < 0.001, respectively). The misdiagnosis rates of renal dynamic imaging in groups A, B, and C due to the different injection levels were significantly different at 94.29%, 77.14%, and 18.29%, respectively.

Conclusions

The times of appearance and regression of the lung shadows and the peak time and peak count ratio in the abdominal aorta in the dynamic renal imaging perfusion phase can help assess the imaging agent injection quality and identify the need for a repeated examination. Improving the imaging agent injection quality can effectively reduce the renal function misdiagnosis rate.
Literatur
3.
Zurück zum Zitat Chan A, Ying L, Jianhua G, et al. SPECT renal dynamic imaging method and its influencing factors. China Equip. 2019;16:160–4. Chan A, Ying L, Jianhua G, et al. SPECT renal dynamic imaging method and its influencing factors. China Equip. 2019;16:160–4.
4.
Zurück zum Zitat Xie P, Li DX, Huang JM, et al. Measurement of glomerular filtration rate by renal dynamic imaging. China Imaging Technol. 2017;28:371–3. Xie P, Li DX, Huang JM, et al. Measurement of glomerular filtration rate by renal dynamic imaging. China Imaging Technol. 2017;28:371–3.
5.
Zurück zum Zitat Yao SH, Jiang BC, Yang XM, et al. Comparison of “bolus” quality of three injection methods in renal dynamic imaging. Hainan Sci. 2018;19:2946–7. Yao SH, Jiang BC, Yang XM, et al. Comparison of “bolus” quality of three injection methods in renal dynamic imaging. Hainan Sci. 2018;19:2946–7.
6.
Zurück zum Zitat Chinese Medical Association. Clinical technical Code of Practice Nuclear Medicine. Beijing: People’s Military Medical Press; 2004, 157, 160, 161 Chinese Medical Association. Clinical technical Code of Practice Nuclear Medicine. Beijing: People’s Military Medical Press; 2004, 157, 160, 161
7.
Zurück zum Zitat Tian R, Zhou Y. Evolution and status of concept and staging criteria of chronic kidney disease. Int J Transplant Blood Purif. 2018;16:1–4. Tian R, Zhou Y. Evolution and status of concept and staging criteria of chronic kidney disease. Int J Transplant Blood Purif. 2018;16:1–4.
8.
Zurück zum Zitat Lu SQ, Lu YQ, Fu W. Research progress of application of radionuclide renal dynamic imaging bolus injection method. Int J Radiat Med Nucl Med. 2020;44:667–71. Lu SQ, Lu YQ, Fu W. Research progress of application of radionuclide renal dynamic imaging bolus injection method. Int J Radiat Med Nucl Med. 2020;44:667–71.
10.
Zurück zum Zitat Qi W, Jianjun X, Lulu Y, Nini W. Influence of shot injection quality on GFR measurement of living kidney transplant donors by Gates method. Labeled Immunoassays Clin Med. 2021;28:1141–5. Qi W, Jianjun X, Lulu Y, Nini W. Influence of shot injection quality on GFR measurement of living kidney transplant donors by Gates method. Labeled Immunoassays Clin Med. 2021;28:1141–5.
Metadaten
Titel
Inferences of SPECT renal dynamic imaging injection quality based on lung and abdominal aorta imaging features
verfasst von
Jicheng Li
Lele Huang
Yongjun Luo
Kai Zhang
Jianyin Wang
Jianzhong Feng
Jiangyan Liu
Publikationsdatum
22.06.2022
Verlag
Springer Nature Singapore
Erschienen in
Annals of Nuclear Medicine / Ausgabe 8/2022
Print ISSN: 0914-7187
Elektronische ISSN: 1864-6433
DOI
https://doi.org/10.1007/s12149-022-01750-8

Weitere Artikel der Ausgabe 8/2022

Annals of Nuclear Medicine 8/2022 Zur Ausgabe