Skip to main content
Erschienen in: Journal of Interventional Cardiac Electrophysiology 3/2014

01.12.2014

Influence of QRS duration on outcome of death or appropriate defibrillator therapy by strategy of left ventricular lead placement in cardiac resynchronization therapy recipients

verfasst von: Samir Saba, Josef Marek, Mian Bilal Alam, Evan Adelstein, David Schwartzman, Sandeep Jain, John Gorcsan

Erschienen in: Journal of Interventional Cardiac Electrophysiology | Ausgabe 3/2014

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Echocardiography-guided (EG) lead placement at the site of latest left ventricular (LV) mechanical activation improves outcome in patients receiving a cardiac resynchronization therapy (CRT) defibrillator (D). The purpose of this study is to examine whether a strategy of EG LV lead placement equally improves outcome in CRT recipients with wide (≥150 ms) versus intermediate (120–149 ms) QRS duration.

Methods

Patients treated with a CRT-D in the Speckle Tracking Assisted Resynchronization Therapy for Electrode Region (STARTER) prospective, randomized trial (108 EG strategy and 75 routine strategy) were followed to the endpoint of death or first appropriate CRT-D therapy. Of the patients enrolled in STARTER, 115 had QRS ≥ 150 ms and 68 had 120 < QRS ≤ 149 ms.

Results

Over a mean follow-up period of 3.7 ± 2.1 years, 62 (33 %) patients died and 40 (22 %) received appropriate CRT-D therapy. Compared to patients with QRS ≥ 150 ms, patients with intermediate QRS had meaningfully worse survival free from ICD therapy (HR = 1.48, p = 0.056). CRT-D therapy-free survival was significantly worse in patients with intermediate QRS duration randomized to the routine LV lead placement strategy, compared to patients with intermediate QRS duration randomized to the EG LV lead placement strategy or patients with wide QRS duration regardless of LV implantation strategy (HR = 2.08, 95 % confidence interval = 1.21–3.56, P = 0.008). This finding was independent in type of cardiomyopathy.

Conclusion

A strategy of EG LV lead placement improves survival free from defibrillator therapy in patients with QRS between 120–149 ms to levels comparable to those of patients with QRS ≥ 150 ms.
Literatur
1.
Zurück zum Zitat Abraham, W. T., Fisher, W. G., Smith, A. L., Delurgio, D. B., Leon, A. R., Loh, E., et al. (2002). Cardiac resynchronization in chronic heart failure. The New England Journal of Medicine, 346, 1845–1853.PubMedCrossRef Abraham, W. T., Fisher, W. G., Smith, A. L., Delurgio, D. B., Leon, A. R., Loh, E., et al. (2002). Cardiac resynchronization in chronic heart failure. The New England Journal of Medicine, 346, 1845–1853.PubMedCrossRef
2.
Zurück zum Zitat Bristow, M. R., Saxon, L. A., Boehmer, J., Krueger, S., Kass, D. A., De Marco, T., et al. (2004). Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure. The New England Journal of Medicine, 350, 2140–2150.PubMedCrossRef Bristow, M. R., Saxon, L. A., Boehmer, J., Krueger, S., Kass, D. A., De Marco, T., et al. (2004). Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure. The New England Journal of Medicine, 350, 2140–2150.PubMedCrossRef
3.
Zurück zum Zitat Cleland, J. G., Daubert, J. C., Erdmann, E., Freemantle, N., Gras, D., Kappenberger, L., et al. (2005). The effect of cardiac resynchronization on morbidity and mortality in heart failure. The New England Journal of Medicine, 352, 1539–1549.PubMedCrossRef Cleland, J. G., Daubert, J. C., Erdmann, E., Freemantle, N., Gras, D., Kappenberger, L., et al. (2005). The effect of cardiac resynchronization on morbidity and mortality in heart failure. The New England Journal of Medicine, 352, 1539–1549.PubMedCrossRef
4.
Zurück zum Zitat Moss, A. J., Hall, W. J., Cannom, D. S., Klein, H., Brown, M. W., Daubert, J. P., et al. (2009). Cardiac-resynchronization therapy for the prevention of heart-failure events. The New England Journal of Medicine, 361, 1329–1338.PubMedCrossRef Moss, A. J., Hall, W. J., Cannom, D. S., Klein, H., Brown, M. W., Daubert, J. P., et al. (2009). Cardiac-resynchronization therapy for the prevention of heart-failure events. The New England Journal of Medicine, 361, 1329–1338.PubMedCrossRef
5.
Zurück zum Zitat Saba, S., Marek, J., Schwartzman, D., Jain, S., Adelstein, E., White, P., et al. (2013). Echocardiography-guided left ventricular lead placement for cardiac resynchronization therapy: results of the Speckle Tracking Assisted Resynchronization Therapy for Electrode Region trial. Circulation. Heart Failure, 6, 427–434.PubMedCrossRef Saba, S., Marek, J., Schwartzman, D., Jain, S., Adelstein, E., White, P., et al. (2013). Echocardiography-guided left ventricular lead placement for cardiac resynchronization therapy: results of the Speckle Tracking Assisted Resynchronization Therapy for Electrode Region trial. Circulation. Heart Failure, 6, 427–434.PubMedCrossRef
6.
Zurück zum Zitat Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A., 3rd, Freedman, R. A., Gettes, L. S., et al. (2013). American College of Cardiology Foundation; American Heart Association Task Force on Practice Guidelines; Heart Rhythm Society. 2012 ACCF/AHA/HRS focused update incorporated into the ACCF/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines and the Heart Rhythm Society. Journal of the American College of Cardiology, 61, e6–e75.PubMedCrossRef Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A., 3rd, Freedman, R. A., Gettes, L. S., et al. (2013). American College of Cardiology Foundation; American Heart Association Task Force on Practice Guidelines; Heart Rhythm Society. 2012 ACCF/AHA/HRS focused update incorporated into the ACCF/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines and the Heart Rhythm Society. Journal of the American College of Cardiology, 61, e6–e75.PubMedCrossRef
7.
Zurück zum Zitat Marek, J. J., Saba, S., Onishi, T., Ryo, K., Schwartzman, D., Adelstein, E. C., et al. (2014). Usefulness of Echocardiographically Guided Left Ventricular Lead Placement for Cardiac Resynchronization Therapy in Patients With Intermediate QRS Width and Non-Left Bundle Branch Block Morphology. The American Journal of Cardiology, 113, 107–116.PubMedCrossRef Marek, J. J., Saba, S., Onishi, T., Ryo, K., Schwartzman, D., Adelstein, E. C., et al. (2014). Usefulness of Echocardiographically Guided Left Ventricular Lead Placement for Cardiac Resynchronization Therapy in Patients With Intermediate QRS Width and Non-Left Bundle Branch Block Morphology. The American Journal of Cardiology, 113, 107–116.PubMedCrossRef
8.
Zurück zum Zitat Lang, R. M., Bierig, M., Devereux, R. B., Flachskampf, F. A., Foster, E., Pellikka, P. A., et al. (2005). Recommendations for chamber quantification: a report from the american society of echocardiography’s guidelines and standards committee and the chamber quantification writing group, developed in conjunction with the european association of echocardiography, a branch of the european society of cardiology. Journal of the American Society of Echocardiography: Official Publication of the American Society of Echocardiography, 18, 1440–1463.CrossRef Lang, R. M., Bierig, M., Devereux, R. B., Flachskampf, F. A., Foster, E., Pellikka, P. A., et al. (2005). Recommendations for chamber quantification: a report from the american society of echocardiography’s guidelines and standards committee and the chamber quantification writing group, developed in conjunction with the european association of echocardiography, a branch of the european society of cardiology. Journal of the American Society of Echocardiography: Official Publication of the American Society of Echocardiography, 18, 1440–1463.CrossRef
9.
Zurück zum Zitat Suffoletto, M. S., Dohi, K., Cannesson, M., Saba, S., & Gorcsan, J., 3rd. (2006). Novel speckle-tracking radial strain from routine black-and-white echocardiographic images to quantify dyssynchrony and predict response to cardiac resynchronization therapy. Circulation, 113, 960–968.PubMedCrossRef Suffoletto, M. S., Dohi, K., Cannesson, M., Saba, S., & Gorcsan, J., 3rd. (2006). Novel speckle-tracking radial strain from routine black-and-white echocardiographic images to quantify dyssynchrony and predict response to cardiac resynchronization therapy. Circulation, 113, 960–968.PubMedCrossRef
10.
Zurück zum Zitat Gorcsan, J., 3rd, Oyenuga, O., Habib, P. J., Tanaka, H., Adelstein, E. C., Hara, H., et al. (2010). Relationship of echocardiographic dyssynchrony to long-term survival after cardiac resynchronization therapy. Circulation, 122, 1910–1918.PubMedCentralPubMedCrossRef Gorcsan, J., 3rd, Oyenuga, O., Habib, P. J., Tanaka, H., Adelstein, E. C., Hara, H., et al. (2010). Relationship of echocardiographic dyssynchrony to long-term survival after cardiac resynchronization therapy. Circulation, 122, 1910–1918.PubMedCentralPubMedCrossRef
11.
Zurück zum Zitat Hara, H., Oyenuga, O. A., Tanaka, H., Adelstein, E. C., Onishi, T., McNamara, D. M., et al. (2012). The relationship of QRS morphology and mechanical dyssynchrony to long-term outcome following cardiac resynchronization therapy. European Heart Journal, 33, 2680–2691.PubMedCentralPubMedCrossRef Hara, H., Oyenuga, O. A., Tanaka, H., Adelstein, E. C., Onishi, T., McNamara, D. M., et al. (2012). The relationship of QRS morphology and mechanical dyssynchrony to long-term outcome following cardiac resynchronization therapy. European Heart Journal, 33, 2680–2691.PubMedCentralPubMedCrossRef
Metadaten
Titel
Influence of QRS duration on outcome of death or appropriate defibrillator therapy by strategy of left ventricular lead placement in cardiac resynchronization therapy recipients
verfasst von
Samir Saba
Josef Marek
Mian Bilal Alam
Evan Adelstein
David Schwartzman
Sandeep Jain
John Gorcsan
Publikationsdatum
01.12.2014
Verlag
Springer US
Erschienen in
Journal of Interventional Cardiac Electrophysiology / Ausgabe 3/2014
Print ISSN: 1383-875X
Elektronische ISSN: 1572-8595
DOI
https://doi.org/10.1007/s10840-014-9953-4

Weitere Artikel der Ausgabe 3/2014

Journal of Interventional Cardiac Electrophysiology 3/2014 Zur Ausgabe

Update Kardiologie