Open Access 01.12.2015 | Original research

Inhomogeneous myocardial stress perfusion in SPECT studies predicts future allograft dysfunction in heart transplant recipients

verfasst von: Christian Wenning, Alexis Vrachimis, Angelo Dell´Aquila, Alvyda Penning, Jörg Stypmann, Michael Schäfers

Erschienen in: EJNMMI Research | Ausgabe 1/2015

Abstract

Background

Myocardial perfusion gated single photon emission computed tomography (SPECT) can be used for non-invasive detection of coronary artery stenosis and cardiac allograft vasculopathy (CAV), which is a crucial factor for the long-term survival of heart transplant (HTx) recipients. A frequently observed finding in myocardial perfusion imaging of patients after HTx is inhomogeneous myocardial perfusion. This finding is not associated with epicardial CAV, but its prognostic relevance is unclear so far. We therefore evaluated the prognosis of patients with homogeneous versus inhomogeneous myocardial stress perfusion.

Methods

One hundred four HTx patients (mean 3.6 ± 2.9 years after HTx) without significant stress-induced ischemia (summed stress score ≤3) in gated SPECT and without CAV were included. Myocardial stress perfusion was visually assessed as homogeneous, moderately, or severely inhomogeneous. The mean follow-up period after SPECT was 9.4 ± 3.1 years. End points were the diagnosis of CAV, major cardiac events (MACE) or death, and the development of allograft dysfunction (left ventricular ejection fraction, LVEF <45 %).

Results

Of all HTx patients, 24 % enrolled in this study (n = 25) presented with inhomogeneous myocardial perfusion. Compared to the patients with homogeneous perfusion, these patients were at higher risk for developing allograft dysfunction (multivariate hazard ratio, HR = 5.59). As to the development of CAV, the occurrence of MACE, or death, no statistical differences were observed between patients with homogenous and inhomogeneous perfusion. There was no correlation between myocardial perfusion pattern and prior cardiac allograft rejections.

Conclusions

Inhomogeneous myocardial stress perfusion in SPECT studies predicts a higher risk for future development of allograft dysfunction in HTx patients (LVEF <45 %) but is not associated with future CAV, MACE, or overall survival.
Hinweise
Christian Wenning and Alexis Vrachimis contributed equally to this work.

Competing interests

The authors declare that they have no competing interests.

Authors’ contributions

CW was responsible for the study design, data analysis, and creation of the manuscript. AV was responsible for data analysis and creation of the manuscript. ADA was responsible for patient data collection and analysis. AP was responsible for data collection and analysis. JS was responsible for patient data collection, study supervision, and critical review of the manuscript. MS was responsible for the study design, study supervision, and critical review of the manuscript. All authors read and approved the final manuscript.
Abkürzungen
ASNC
American Society of Nuclear Cardiology
BMI
body mass index
CAD
coronary artery disease
CAV
cardiac allograft vasculopathy
EDV
enddiastolic volume
ESV
endsystolic volume
HR
hazard ratio
HTx
heart transplantation
LVEF
left ventricular ejection fraction
MACE
major cardiac event
MPHR
maximum predicted heart rate
MPI
myocardial perfusion imaging
MBq
megabecquerel
OS
overall survival
PET
positron emission computed tomography
SDS
summed difference score
SPECT
single photon emission computed tomography
SRS
summed rest score
SSS
summed stress score
TTE
transthoracic echocardiogram

Background

Cardiac allograft vasculopathy (CAV) is a major complication associated with decreased long-term survival in heart transplant recipients [1, 2]. CAV is a primary immune-mediated process which differs from other vasculopathies such as coronary artery disease (CAD). The pathophysiological process in the vessel wall in CAV patients is characterized by a diffuse concentric intimal proliferation affecting both the epicardial and the endocardial arteries with no preferential localization [3, 4]. In the course of the disease progressive heart failure, arrhythmia and sudden cardiac death may occur [1]. Once severe CAV has developed, retransplantation is the only definitive treatment option [5]. Serial coronary angiography combined with intravascular ultrasound (IVUS) is the clinical standard for the detection of significant CAV [6]. However, non-invasive myocardial perfusion imaging (MPI) is increasingly gaining attention as an attractive alternative monitoring tool for clinically significant CAV, providing information on both the perfusion provided by the main epicardial vessels and the microcirculation [7]. Although the sensitivity of MPI for the detection of CAV is reported to be lower than for the detection of CAD [6], several clinical studies have identified perfusion deficits assessed by MPI as strong predictors for cardiac events in patients after heart transplantation (HTx) [79]. Recent results indicate that stress-induced ischemia and left ventricular dysfunction in HTx patients assessed by gated single photon emission computed tomography (SPECT) correlate with prognosis [10, 11].
Apart from the presence of ischemia or scarring, a frequent finding in MPI of heart transplant recipients is inhomogeneous myocardial perfusion in angiographically normal patients [12]. Previous studies showed that inhomogeneous myocardial perfusion is rare within the first year after transplantation but more frequently observed over time [13, 14]. In a mixed cohort also including patients with known CAV, the prevalence was up to 38 % [11]. Interestingly, the finding is not associated with the prevalence of CAV in angiography at the time of imaging [13, 15]. Even when performed with IVUS, coronary angiography did not detect any kind of CAV in patients presenting with inhomogeneous myocardial perfusion pattern [15]. Thus, perfusion inhomogeneity is assumed to reflect microvasculopathy which is not detectable by angiography [12, 15], although this hypothesis has not been proven so far. Despite these correlative findings, the prognostic relevance of inhomogeneneity in MPI of heart transplant recipients remains unclear. Therefore, the present study evaluates the prognostic impact of inhomogeneous myocardial perfusion in heart transplant recipients without CAV in coronary angiography.

Methods

Study population

One hundred sixty-one HTx recipients (137 males, 24 females, mean age at HTx 50.7 ± 12.2 years) undergoing orthotopic cardiac allograft transplantation between 1990 and 2004, who underwent myocardial perfusion gated SPECT followed by coronary angiography on a routine basis between 04/2000 and 01/2006 at the University Hospital Münster were identified. Patients with significant myocardial ischemia and/or scar (summed stress score (SSS) ≥4; n = 42), evidence of significant epicardial CAV in coronary angiography (> 50 % stenosis; n = 33), and/or left ventricular ejection fraction (LVEF) <45 % (n = 25) at the start of the study were excluded. A time interval of 4 weeks between coronary angiography and the SPECT study was tolerated. This resulted in a total population of 104 patients.
The institutional review board of the Medical Association of Westfalen-Lippe and the Faculty of Medicine, University of Münster approved this retrospective study. For the calculation of a threshold for LVEF data from an age-matched, site-specific control group of 80 patients with normal perfusion, a low pre-test likelihood of CAD and without prior cardiac interventions (50 men, 30 women, mean age 50.5 ± 9.6 years; p = not statistically significant versus HTx patients) was used. The threshold for normal LVEF was defined as the mean value ± two standard deviations.

Gated SPECT and image analysis

In all patients, gated SPECT was performed with 99mTc-tetrofosmin as the perfusion agent (MYOVIEW™, General Electric Company, Fairfield, CT, USA). Each vial was reconstituted with 99mTc-O4- according to the manufacturer’s instructions.
All investigations were performed by a sequential stress/rest study (1-day protocol). The stress test was performed according to international standards by physical exercise. The assessment of cardiac function was based on gated SPECT data obtained under resting conditions. For the stress study, a standard dose of about 250 MBq99mTc-tetrofosmin was injected at peak stress while about 750 MBq were administered under resting conditions. All patients received their standard prescribed medication only directly after the stress test, whereas they did not take their medication 12 h prior to the stress test.
Data acquisition started 30 to 60 min after intravenous tracer injection (ECAM, Siemens Gammasonics; 2 heads, 24 projections, 64 × 64 matrix, 180° orbit, 50 s per step, 8 ECG-gates, zoom factor = 1.45). Flood sources were used to obtain transmission data for attenuation correction. Data were reconstructed into static data sets with and without attenuation correction for perfusion analysis and, for the rest study, into ECG-gated data sets for functional analysis (filtered backprojection, butterworth filter, cutoff 0.6, order 5). Reconstructed images were resliced into short axis, horizontal long axis, and vertical long axis for clinical reading. Tracer uptake was semiquantitatively scored for ischemia/scarring from three representative short axis slices (apical, mid-ventricular and basal) and a long axis slice using the 17-segment model. Each of the 17 segments was scored by two independent and experienced observers blinded to the angiographic results according to the ASNC guideline for semiquantitative analysis [16]. Accordingly, summed rest score (SRS), SSS, and summed difference score (SDS) were calculated.
Left ventricular endsystolic and enddiastolic volumes (ESV, EDV) and LVEF were calculated from the ECG-gated SPECT data using a validated contour finding algorithm (ESM, elastic surface model) [17]. Left ventricular myocardium was segmented into 24 sectors, each 15° wide and containing 16 small segments arranged from the apex to the basis of each sector, resulting in 384 segments (Fig. 1). In each case, the three outer, most basal segments (n = 72) were excluded from analysis to exclude segments with physiologically decreased uptake in the membraneous septum. This resulted in a total of 312 small segments to analyze. On that basis, myocardial stress and rest perfusion was then graded into 3° of inhomogeneity (no/minimal, moderate, and severe) by two experienced observers, blinded to the results of the clinical follow-up as follows: segments showing a tracer uptake of less than 70 % of the maximum myocardial uptake were considered as pathological. Cases presenting with <10 % pathologic segments were graded as homogeneous, cases with 10–20 % pathological segments were graded as moderately inhomogeneous, and cases showing a decreased uptake in > 20 % of the segments were considered as severely inhomogeneous. Pathological segments did not need to be adjacent. Since no other reliable reference standard for the grading of myocardial perfusion inhomogeneity exists so far, visual grading performed by two independent observers was used as reference. The two observers experienced in nuclear cardiology and blinded towards the clinical data independently graded the degree of inhomogeneity. The kappa values for the intra- and interobserver agreement were 0.911 and 0.858, respectively. In single cases of disagreement between the observers, a consensus was found for final grading.

Coronary angiography

Coronary angiography was performed using the Judkins technique [18]. Angiograms were analyzed visually by a consensus of two experienced observers blinded to the patient’s medical history and to the SPECT results. As mentioned above, patients with angiographical findings of CAV [3] were excluded from the analysis.

Echocardiography

Routine transthoracic echocardiograms (TTE) were performed every 3 months from the time of SPECT imaging by experienced cardiac sonographers according to the guidelines of the American Society of Echocardiography (ASE) [19]. LVEF was assessed in every patient.

Follow-up

Assessment of the left ventricular function in the follow-up was performed by TTE every 3 months. Serial protocol coronary angiography was performed once a year to assess the presence of epicardial CAV.
End points were defined as: manifestation of CAV in coronary angiography, major cardiac event (MACE: coronary revascularization, myocardial infarction, cardiac death or re-transplantation), death from any cause, and the development of allograft dysfunction (LVEF <45 %) assessed by TTE.

Statistical analysis

Statistical analysis was performed using the SPSS software package (IBM SPSS Statistics for Mac, Version 22.0. Armonk, NY: IBM Corp.). Analysis of discrete variables was performed using the chi-squared test. Comparisons of continuous variables were performed either by a two-sided Student’s t test for unpaired samples or by one-way analysis of variance (ANOVA) with a Bonferroni correction applied where appropriate. Kaplan-Meier survival curves with log-rank tests were used for the analysis of the patient survival. Data for patients who were lost to follow-up were censored at the time of the last contact. Univariate and multivariate Cox proportional hazards models were used for estimation of hazard ratios (HR) and associated 95 % confidence intervals (CI). A p < 0.05 was considered as statistically significant.

Results

One hundred four patients were enrolled in the study (86 males, 18 females; mean age at MPI after HTx 52.9 ± 13.1 years, mean time after HTx 3.6 ± 2.9 years). Patients’ characteristics are shown in Table 1. The mean follow-up time was 9.4 ± 3.1 years after MPI (median, 10.0 years; range, 2.2–13.7 years).
Table 1
Patients’ characteristics
Variable
All (n = 104)
Homogeneous perfusion (n = 79)
Inhomogeneous perfusion (n = 25)
p value
Age at date of HTx (years)
49.4 ± 12.6
49.4 ± 12.6
49.4 ± 13.3
0.98
Gender (men/women)
86 (83 %)/18 (17 %)
65 (82 %)/14 (18 %)
21 (84 %)/4 (16 %)
0.46
BMI
25.8 ± 3.3
25.9 ± 3.5
25.3 ± 2.8
0.51
Reason for HTx
    
 CAD
50 (48 %)
37 (47 %)
13 (52 %)
0.68
 Dilated cardiomyopathy
44 (42 %)
35 (44 %)
9 (36 %)
0.07
 Others
10 (10 %)
7 (9 %)
3 (12 %)
0.14
 Systemic hypertension
88 (85 %)
65 (82 %)
23 (92 %)
0.78
 Diabetes mellitus
18 (17 %)
14 (18 %)
4 (16 %)
0.68
 Hypercholesterolemia
76 (73 %)
58 (73 %)
18 (72 %)
0.25
 Renal failure
71 (68 %)
51 (65 %)
20 (80 %)
0.22
 Malignancy
14 (13 %)
13 (16 %)
1 (4 %)
0.12
 Peripheral artery disease
12 (12 %)
10 (13 %)
2 (8 %)
0.55
 Beta blockers
26 (25 %)
19 (24 %)
7 (28 %)
0.55
 Calcium channel antagonists
88 (85 %)
72 (91 %)
16 (64 %)
0.04
 ACE inhibitors
27 (26 %)
19 (24 %)
8 (32 %)
0.39
 Statins
94 (90 %)
73 (92 %)
21 (84 %)
0.77
 Coronary interventions in the follow-up
15 (15 %)
13 (16 %)
2 (8 %)
0.06
 MACE (incl. interventions)
20 (19 %)
15 (19 %)
5 (20 %)
0.14
 Deaths in observation period
11 (11 %)
7 (9 %)
4 (16 %)
0.26
Values for age and BMI (body mass index) are expressed as mean ± standard deviation. All other data are absolute values

Inhomogeneity

The degree of inhomogeneity was more pronounced in the stress perfusion (Table 2). There were no cases with inhomogeneous perfusion more pronounced in the rest study than in the stress study. Therefore, only the degree of inhomogeneity of the stress perfusion was further considered. Myocardial perfusion pattern was graded as homogeneous in 76 % of the patients (n = 79), while inhomogeneous myocardial perfusion was present in 24 % of the patients (n = 25), from which 19 SPECT scans were classified as moderately inhomogeneous and 6 as severely inhomogeneous.
Table 2
Frequency of inhomogeneous myocardial stress and rest perfusion
  
Rest
Stress
Inhomogeneity
No
Moderate
Severe
No
79
0
0
Moderate
0
19
0
Severe
0
4
2
Total
79
23
2
Concerning the prevalence of inhomogeneous myocardial perfusion, there were no significant differences between men (n = 21) and women (n = 4; p = 0.69). The mean time after HTx at the time of imaging did not differ significantly between patients with homogeneous and inhomogeneous perfusion (3.7 ± 2.9 years versus 3.1 ± 3.0 years, p = 0.42).
In our cohort, the mean maximum predicted heart rate (MPHR) achieved was 82.5 ± 7.8 %. Of the patients, 77.9 % (n = 81) reached a MPHR ≥85 %. Otherwise, the exercise test was abandoned due to symptoms (angina pectoris or dyspnea).
Semiquantitative perfusion scores are presented in Table 3. There was no significant correlation between the distribution of SRS or SSS between patients with homogeneous or inhomogeneous myocardial perfusion (p = 0.324 and p = 0.095, respectively).
Table 3
Summed rest scores (SRS) and summed stress scores (SSS)
 
Inhomogeneity
Total
No
Yes
SRS
0
40
10
50
 
1
20
9
29
 
2
18
6
24
 
3
1
0
1
Total
 
79
25
104
SSS
0
31
8
39
1
21
6
27
2
22
8
30
3
5
3
8
Total
79
25
104
The presence of significant coronary artery stenosis was excluded in every patient. Of the 104 patients, 92 (88.5 %) had no detectable angiographic lesion, whereas 12 patients (11.5 %) presented with single vessel stenosis <50 %. Here, there were no statistical differences between the prevalence in the homogeneous and the inhomogeneous group.
Inhomogeneous myocardial perfusion did not correlate with the severity and frequency of previous cardiac allograft rejections (p = 0.71; not shown) and did not correlate with cardiac disease before transplantation (p = 0.88; not shown).

LV function and follow-up

At the time of gated SPECT, LVEF was predominantly preserved but significantly lower in patients with inhomogeneous perfusion than in patients with homogeneous perfusion (61.9 ± 9.2 versus 67.7 ± 7.5 %; p = 0.008) and ESV was higher (70 ± 24 versus 54 ± 18 ml; p = 0.002; Fig. 2a, b). EDV did not differ significantly (177 ± 37 versus 165 ± 30 ml; p = 0.11; Fig. 2c).
Although statistically not significant, data showed a tendency of LVEF worsening with the degree of inhomogeneity: 67 ± 8 % in patients with homogeneous perfusion, 63 ± 9 % in patients with moderately inhomogeneous perfusion, and 59 ± 10 % in patients with severely inhomogeneous perfusion (p = 1.0, p = 0.29, and p = 0.11).
In the follow-up, inhomogeneous myocardial perfusion was associated with a significantly more frequent decrease of LVEF <45 % (Fig. 3a). The univariate HR was 5.0 (95 % CI, 1.52–16.4; p < 0.01; Table 4). Particularly, the combined finding of inhomogeneous perfusion and LVEF ≤57 % (=threshold value calculated from control group data) in gated SPECT was associated with an increased risk for the development of allograft dysfunction (HR 3.5 [CI 1.74–6.98], p < 0.01; Fig. 3b).
Table 4
Univariate and multivariate analysis of potential risk factors with regards to LV dysfunction (first row) and MACE (second row)
 
Univariate analysis
Multivariate analysis
Variable
HR
95 % CI
p value
HR
95 % CI
p value
Perfusion inhomogeneity
No
Reference
Reference
Yes
5.0
1.52–16.4
0.008
5.59
1.69–18.5
0.005
3.79
0.53–26.91
0.183
   
ACR
≤grade 2R
Reference
Reference
≥grade 2R
0.18
0.04–0.81
0.025
0.16
0.34–0.73
0.018
0.27
0.03–2.57
0.253
   
Hypertension
No
Reference
 
Yes
0.39
0.12–1.29
0.123
   
0.54
0.06–5.17
0.537
   
PAD
No
Reference
 
Yes
1.82
0.39–8.44
0.439
   
2.2
0.44–11.07
0.338
   
Renal failure
No
Reference
 
Yes
2.96
0.64–13.57
0.164
   
1.74
0.180–16.87
0.632
   
Diabetes
No
Reference
 
Yes
1.15
0.31–4.23
0.837
   
0.61
0.14–2.61
0.51
   
In a multivariate analysis of several risk factors, only inhomogeneous myocardial perfusion was predictive for the development of allograft dysfunction (Table 4).
Previous cardiac allograft rejections ≥grade 2R (ISHLT 2004) were not predictive of the development of allograft dysfunction but in contrast associated with a preserved LV function (Table 4).
No association was found between inhomogeneous myocardial perfusion and the manifestation of epicardial CAV in coronary angiography in the follow-up (Fig. 4). Moreover, no significant differences were found between the groups with regard to the occurrence of MACE or death of any cause in the follow-up period (Fig. 5a, b).

Immunosuppression

Of the patients, 87.5 % (n = 91) initially received a cyclosporine-based immunosuppressive therapy, whereas 12.5 % of the patients received either everolimus (n = 1), sirolimus (n = 2), or tacrolimus (n = 10). In the follow-up, 36.5 % (n = 38) of the patients received a change in immunosuppression, whereas in 26 % (n = 27) of the cases, a change towards everolimus was performed. This change was more frequently performed in the group with initially inhomogeneous myocardial perfusion pattern (36 versus 23 %).

Discussion

In the follow-up of heart transplantation, inhomogeneous perfusion is a frequent finding in myocardial perfusion gated SPECT. However, its clinical significance is still uncertain. Only a few number of published reports have analyzed myocardial perfusion inhomogeneity in 201Thallium myocardial SPECT of heart transplant recipients so far [13, 15]. Here, the frequency and extent of perfusion inhomogeneity was reported to increase with time after HTx. However, this finding did not correlate with the presence of allograft vasculopathy as detected by coronary angiography and IVUS [15]. Thus, perfusion inhomogeneity in SPECT was assumed to be caused by small vessel alterations. Despite these first important findings, the few listed studies were either correlative or only covered a rather short follow-up time.
In this study, HTx patients had a median follow-up of ~10 years after a first myocardial perfusion gated SPECT in the course of heart transplantation. At the time of SPECT imaging, patients with inhomogeneous perfusion already had a preserved but significantly lower LVEF in comparison to patients presenting with homogeneous myocardial perfusion, with a non-significant trend of further deterioration of LVEF with a higher degree of inhomogeneity. In the follow-up, patients with inhomogeneous myocardial perfusion developed left ventricular allograft dysfunction more frequently than patients with homogeneous myocardial perfusion. Among these patients, particularly those showing perfusion inhomogeneity in combination with an already slightly restricted LVEF in gated SPECT were at a higher risk for the development of cardiac allograft dysfunction than patients with inhomogeneous perfusion but preserved LVEF. In a multivariate analysis including several risk factors, only inhomogeneous myocardial perfusion turned out as an independent predictor for the development of allograft dysfunction. Surprisingly, former acute allograft rejections were associated with a preserved LV function in the follow-up. This finding is confounding at first sight but may be explained by a possibly more aggressive immunosuppressive therapy in these individuals.
In non-transplanted patients, MPHR ≥ 85 % is targeted in a physical stress test. Although MPHR is not established in the (denervated) HTx population and therefore may only serve as an approximate parameter for cardiac stress in HTx patients, the targeted MPHR was virtually achieved in our cohort. Thus, the diagnostic accuracy of MPI should not be limited. In line with results from former studies, perfusion inhomogeneity did not correlate with the presence of epicardial CAV in coronary angiography. On the other hand, the degree inhomogeneity was more pronounced in the stress perfusion. Thus, the results of our study support the hypothesis of microvascular disease leading to inhomogeneous myocardial perfusion in HTx patients. Microvasculopathy is consecutively causing a diffuse and chronic ischemic cardiomyopathy manifested by progressive left ventricular dysfunction and most probably fibrosis [20]. Since no association between the SPECT perfusion pattern and the frequency or severity of prior allograft rejections could be observed, a diffuse myocardial damage due to former acute allograft rejections is unlikely to cause the observed perfusion inhomogeneity.
Inhomogeneous myocardial perfusion in SPECT can also be observed in non-transplanted patients with angiographically normal coronary arteries. Formerly often claimed as false positive, studies suggest that endothelial dysfunction might be the reason for the observed perfusion patterns in these patients [21]. IVUS measurements revealed that defects in myocardial perfusion scintigraphy correlate with occult atherosclerosis without the presence of significant epicardial coronary artery stenosis in angiography [22]. These results suggest that regionally impaired myocardial perfusion reserve due to microvascular dysfunction may cause relative hypoperfusion in myocardial perfusion gated SPECT. Using myocardial perfusion positron emission computed tomography (PET), quantitative perfusion abnormalities have been verified in patients with arterial hypertension or patients with dilated and hypertrophic cardiomyopathy without significant epicardial coronary artery stenosis in coronary angiography, respectively—findings which underline the importance of coronary microcirculation with regard to analysis of myocardial perfusion images [23]. Myocardial perfusion is also often impaired in diabetic patients [24], and accumulating evidence suggests that small vessel disease also plays a significant role in the development of cardiac dysfunction and the development of ‘diabetic cardiomyopathy’ [25]. That kind of cardiomyopathy is characterized by myocardial dysfunction in the absence of coronary artery disease [26]. Most probably, microvascular dysfunction is also responsible for alterations in heart function such as increased ventricular wall stiffness and reduced cardiac contractility [27]. Similar to the findings in these cardiomyopathies, HTx patients enrolled in our study were free of epicardial CAV or coronary artery disease although the pathophysiological processes leading to CAV basically differ from those causing diabetic microangiopathy. Nevertheless, microvasculopathy which is due to medial rather than endothelial disease or a combination of both [4] is most probably responsible for the more frequent development of cardiac allograft systolic dysfunction in HTx patients presenting with inhomogeneous perfusion in SPECT imaging. Although the inhomogeneous perfusion pattern was not associated with impaired survival of the patients in our follow-up period (≈10 years after SPECT), it has been shown that microvasculopathy is associated with a worse overall survival in the long-term follow-up (up to 15 years after HTx) [4]. Recently, McArdle et al. could demonstrate that quantitation of coronary flow reserve by dynamic PET has an additional prognostic value in HTx patients. They could show that patients with impaired coronary flow reserve were at higher risk for adverse events in a median follow-up of about 18 months [28]. Particularly, the analysis of coronary flow reserve in addition to the analysis of relative perfusion differences, which may miss microvascular disease, enhanced the prognostic power of myocardial perfusion imaging. In this context, further prospective studies using quantitative myocardial perfusion PET may shed light on the hypothesis of microvasculopathy causing inhomogeneity beyond the SPECT findings presented here.
Most importantly, HTx patients presenting with inhomogeneous myocardial perfusion are at an increased risk for the development of future allograft dysfunction. Therefore, the analysis of inhomogeneity of myocardial perfusion and the integration of this finding into the clinical report can aid the management of HTx patients in the follow-up of transplantation, although patients may not initially present with significant myocardial ischemia, epicardial CAV, or signs of heart failure. The presence of inhomogeneous perfusion could alert clinicians early to consider a more intensive monitoring of left ventricular function and potential additional treatments in order to prevent a further progression of microvasculopathy and the development of progressive allograft failure. Interestingly, despite this finding, there were no statistically significant differences between patients with homogeneous and inhomogeneous perfusion with regard to the occurrences of MACE or deaths. The overall survival is generally good in the cohort, independent from the extent of perfusion inhomogeneity. A possible explanation could be the more frequent change to everolimus in the inhomogeneous group which may have reduced event rates. Due to the clinical setting of the study, clinicians were aware of the imaging results. However, changes of immunosuppressive therapy were not made depending on the grade of inhomogeneity reported.

Limitations

A limitation is given by the mixed cohort and the retrospective design of the study—that is not every patient could be included from the date of HTx on, and the recruitment period was long. Thus, we do not know if patients presenting with inhomogeneous perfusion in the first SPECT studies available may have had presented with similar perfusion patterns already at earlier time points. On the other hand, the results should be comparable, since there is no difference in the mean time interval after HTx between the analyzed groups. Moreover, the presented results may be less applicable to women since the cohort was dominated by male individuals.
A methodological limitation may be the grading system for inhomogeneous myocardial perfusion pattern. The cutoff values used for grading of inhomogeneity were defined in comparison to visual impression of myocardial perfusion pattern. Although the intra- and interobserver agreement was very good, the grading system used is obviously user-dependent and subjective by nature. Nevertheless, we think that that kind of grading of myocardial perfusion inhomogeneity is reasonably feasible, apart from that there is a lack of custom-made software for quantitation of perfusion inhomogeneity so far. A formerly published score of inhomogeneity [15] was not deemed suitable for the analysis, since this method was based on 201Thallium SPECT images without attenuation correction, and the score excluded the whole inferior left ventricular wall.
Another limitation of the study is the lack of quantitative data like absolute blood flow and cardiac flow reserve which could confirm the hypothesis of microvascular dysfunction better than SPECT can do.

Conclusions

In summary, inhomogeneous myocardial stress perfusion in gated SPECT of HTx patients is associated with a poor prognosis concerning the development of allograft dysfunction, defined as LVEF <45 %. On the other hand, inhomogeneity was neither associated with the future development of epicardial CAV nor with the occurrence of MACE or with all cause mortality.

Acknowledgements

We thank Anne Kanzog, Christine Baetza, and Tim Kodalle for the excellent technical assistance and data collection.

Funding

This work was supported by the Deutsche Forschungsgemeinschaft (DFG), Sonderforschungsbereich 656, projects C11 and C06.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Competing interests

The authors declare that they have no competing interests.

Authors’ contributions

CW was responsible for the study design, data analysis, and creation of the manuscript. AV was responsible for data analysis and creation of the manuscript. ADA was responsible for patient data collection and analysis. AP was responsible for data collection and analysis. JS was responsible for patient data collection, study supervision, and critical review of the manuscript. MS was responsible for the study design, study supervision, and critical review of the manuscript. All authors read and approved the final manuscript.
Literatur
1.
Zurück zum Zitat von Scheidt W. Cardiac allograft vasculopathy—problem and model. Z Kardiol. 2000;89 Suppl 9:IX/2-5. von Scheidt W. Cardiac allograft vasculopathy—problem and model. Z Kardiol. 2000;89 Suppl 9:IX/2-5.
2.
Zurück zum Zitat Taylor DO, Stehlik J, Edwards LB, Aurora P, Christie JD, Dobbels F, et al. Registry of the International Society for Heart and Lung Transplantation: Twenty-sixth Official Adult Heart Transplant Report-2009. J Heart Lung Transplant. 2009;28:1007–22.CrossRefPubMed Taylor DO, Stehlik J, Edwards LB, Aurora P, Christie JD, Dobbels F, et al. Registry of the International Society for Heart and Lung Transplantation: Twenty-sixth Official Adult Heart Transplant Report-2009. J Heart Lung Transplant. 2009;28:1007–22.CrossRefPubMed
3.
Zurück zum Zitat Wellnhofer E, Stypmann J, Bara CL, Stadlbauer T, Heidt MC, Kreider-Stempfle HU, et al. Angiographic assessment of cardiac allograft vasculopathy: results of a Consensus Conference of the Task Force for Thoracic Organ Transplantation of the German Cardiac Society. Transpl Int. 2010;23:1094–104.CrossRefPubMed Wellnhofer E, Stypmann J, Bara CL, Stadlbauer T, Heidt MC, Kreider-Stempfle HU, et al. Angiographic assessment of cardiac allograft vasculopathy: results of a Consensus Conference of the Task Force for Thoracic Organ Transplantation of the German Cardiac Society. Transpl Int. 2010;23:1094–104.CrossRefPubMed
4.
Zurück zum Zitat Hiemann NE, Wellnhofer E, Knosalla C, Lehmkuhl HB, Stein J, Hetzer R, et al. Prognostic impact of microvasculopathy on survival after heart transplantation: evidence from 9713 endomyocardial biopsies. Circulation. 2007;116:1274–82.CrossRefPubMed Hiemann NE, Wellnhofer E, Knosalla C, Lehmkuhl HB, Stein J, Hetzer R, et al. Prognostic impact of microvasculopathy on survival after heart transplantation: evidence from 9713 endomyocardial biopsies. Circulation. 2007;116:1274–82.CrossRefPubMed
5.
Zurück zum Zitat Valantine H. Cardiac allograft vasculopathy after heart transplantation: risk factors and management. J Heart Lung Transplant. 2004;23:S187–93.CrossRefPubMed Valantine H. Cardiac allograft vasculopathy after heart transplantation: risk factors and management. J Heart Lung Transplant. 2004;23:S187–93.CrossRefPubMed
6.
Zurück zum Zitat Pollack A, Nazif T, Mancini D, Weisz G. Detection and imaging of cardiac allograft vasculopathy. JACC Cardiovasc Imaging. 2013;6:613–23.CrossRefPubMed Pollack A, Nazif T, Mancini D, Weisz G. Detection and imaging of cardiac allograft vasculopathy. JACC Cardiovasc Imaging. 2013;6:613–23.CrossRefPubMed
7.
Zurück zum Zitat Ciliberto GR, Ruffini L, Mangiavacchi M, Parolini M, Sara R, Massa D, et al. Resting echocardiography and quantitative dipyridamole technetium-99m sestamibi tomography in the identification of cardiac allograft vasculopathy and the prediction of long-term prognosis after heart transplantation. Eur Heart J. 2001;22:964–71.CrossRefPubMed Ciliberto GR, Ruffini L, Mangiavacchi M, Parolini M, Sara R, Massa D, et al. Resting echocardiography and quantitative dipyridamole technetium-99m sestamibi tomography in the identification of cardiac allograft vasculopathy and the prediction of long-term prognosis after heart transplantation. Eur Heart J. 2001;22:964–71.CrossRefPubMed
8.
Zurück zum Zitat Verhoeven PP, Lee FA, Ramahi TM, Franco KL, Mendes de Leon C, Amatruda J, et al. Prognostic value of noninvasive testing one year after orthotopic cardiac transplantation. J Am Coll Cardiol. 1996;28:183–9.CrossRefPubMed Verhoeven PP, Lee FA, Ramahi TM, Franco KL, Mendes de Leon C, Amatruda J, et al. Prognostic value of noninvasive testing one year after orthotopic cardiac transplantation. J Am Coll Cardiol. 1996;28:183–9.CrossRefPubMed
9.
Zurück zum Zitat Hacker M, Tausig A, Romuller B, Hoyer X, Klauss V, Stempfle U, et al. Dobutamine myocardial scintigraphy for the prediction of cardiac events after heart transplantation. Nucl Med Commun. 2005;26:607–12.CrossRefPubMed Hacker M, Tausig A, Romuller B, Hoyer X, Klauss V, Stempfle U, et al. Dobutamine myocardial scintigraphy for the prediction of cardiac events after heart transplantation. Nucl Med Commun. 2005;26:607–12.CrossRefPubMed
10.
Zurück zum Zitat Manrique A, Bernard M, Hitzel A, Bubenheim M, Tron C, Agostini D, et al. Diagnostic and prognostic value of myocardial perfusion gated SPECT in orthotopic heart transplant recipients. J Nucl Cardiol. 2010;17:197–206.CrossRefPubMed Manrique A, Bernard M, Hitzel A, Bubenheim M, Tron C, Agostini D, et al. Diagnostic and prognostic value of myocardial perfusion gated SPECT in orthotopic heart transplant recipients. J Nucl Cardiol. 2010;17:197–206.CrossRefPubMed
11.
Zurück zum Zitat Wenning C, Stypmann J, Papavassilis P, Sindermann J, Schober O, Hoffmeier A, et al. Left ventricular dilation and functional impairment assessed by gated SPECT are indicators of cardiac allograft vasculopathy in heart transplant recipients. J Heart Lung Transplant. 2012;31:719–28.CrossRefPubMed Wenning C, Stypmann J, Papavassilis P, Sindermann J, Schober O, Hoffmeier A, et al. Left ventricular dilation and functional impairment assessed by gated SPECT are indicators of cardiac allograft vasculopathy in heart transplant recipients. J Heart Lung Transplant. 2012;31:719–28.CrossRefPubMed
12.
Zurück zum Zitat Kerber S, Puschkas C, Jonas M, Janssen F, Heinemann-Vechtel O, Kosch M, et al. Can Tl-201 myocardial SPECT abnormalities in orthotopic heart recipients be explained by coronary vessel wall alterations assessed by intravascular ultrasound? Int J Cardiol. 1996;57:91–6.CrossRefPubMed Kerber S, Puschkas C, Jonas M, Janssen F, Heinemann-Vechtel O, Kosch M, et al. Can Tl-201 myocardial SPECT abnormalities in orthotopic heart recipients be explained by coronary vessel wall alterations assessed by intravascular ultrasound? Int J Cardiol. 1996;57:91–6.CrossRefPubMed
13.
Zurück zum Zitat Wu YW, Yen RF, Lee CM, Ho YL, Wang SS, Hsu RB, et al. Usefulness of progressive inhomogeneity of myocardial perfusion and chronotropic incompetence in detecting cardiac allograft vasculopathy: evaluation with dobutamine thallium-201 myocardial SPECT. Cardiology. 2005;104:156–61.CrossRefPubMed Wu YW, Yen RF, Lee CM, Ho YL, Wang SS, Hsu RB, et al. Usefulness of progressive inhomogeneity of myocardial perfusion and chronotropic incompetence in detecting cardiac allograft vasculopathy: evaluation with dobutamine thallium-201 myocardial SPECT. Cardiology. 2005;104:156–61.CrossRefPubMed
14.
Zurück zum Zitat Yen RF, Ho YL, Chou NK, Hsu RB, Huang PJ. Inhomogeneity of myocardial perfusion in heart transplant recipients: evaluation with dobutamine thallium-201 SPECT. Nucl Med Commun. 2001;22:1015–9.CrossRefPubMed Yen RF, Ho YL, Chou NK, Hsu RB, Huang PJ. Inhomogeneity of myocardial perfusion in heart transplant recipients: evaluation with dobutamine thallium-201 SPECT. Nucl Med Commun. 2001;22:1015–9.CrossRefPubMed
15.
Zurück zum Zitat Puskas C, Kosch M, Kerber S, Jonas M, Weyand M, Breithardt G, et al. Progressive heterogeneity of myocardial perfusion in heart transplant recipients detected by thallium-201 myocardial SPECT. J Nucl Med. 1997;38:760–5.PubMed Puskas C, Kosch M, Kerber S, Jonas M, Weyand M, Breithardt G, et al. Progressive heterogeneity of myocardial perfusion in heart transplant recipients detected by thallium-201 myocardial SPECT. J Nucl Med. 1997;38:760–5.PubMed
16.
Zurück zum Zitat Hansen CL, Goldstein RA, Akinboboye OO, Berman DS, Botvinick EH, Churchwell KB, et al. American Society of Nuclear Cardiology. Myocardial perfusion and function: single photon emission computed tomography. J Nucl Cardiol. 2007;14:e39–60.CrossRefPubMed Hansen CL, Goldstein RA, Akinboboye OO, Berman DS, Botvinick EH, Churchwell KB, et al. American Society of Nuclear Cardiology. Myocardial perfusion and function: single photon emission computed tomography. J Nucl Cardiol. 2007;14:e39–60.CrossRefPubMed
17.
Zurück zum Zitat Stegger L, Lipke CS, Kies P, Nowak B, Schober O, Buell U, et al. Quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPECT: validation of an elastic surface model approach in comparison to cardiac magnetic resonance imaging, 4D-MSPECT and QGS. Eur J Nucl Med Mol Imaging. 2007;34:900–9.CrossRefPubMed Stegger L, Lipke CS, Kies P, Nowak B, Schober O, Buell U, et al. Quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPECT: validation of an elastic surface model approach in comparison to cardiac magnetic resonance imaging, 4D-MSPECT and QGS. Eur J Nucl Med Mol Imaging. 2007;34:900–9.CrossRefPubMed
19.
Zurück zum Zitat American College of Cardiology Foundation Appropriate Use Criteria Task Force, American Society of Echocardiography, American Heart Association, American Society of Nuclear Cardiology, Heart Failure Society of America, Heart Rhythm Society, Society for Cardiovascular Angiography and Interventions, Society of Critical Care Medicine, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, Douglas PS, Garcia MJ, Haines DE, Lai WW, Manning WJ, et al. ACCF/ASE/AHA/ASNC/HFSA/HRS/SCAI/SCCM/SCCT/SCMR 2011 Appropriate Use Criteria for Echocardiography. A Report of the American College of Cardiology Foundation Appropriate Use Criteria Task Force, American Society of Echocardiography, American Heart Association, American Society of Nuclear Cardiology, Heart Failure Society of America, Heart Rhythm Society, Society for Cardiovascular Angiography and Interventions, Society of Critical Care Medicine, Society of Cardiovascular Computed Tomography, and Society for Cardiovascular Magnetic Resonance Endorsed by the American College of Chest Physicians. J Am Coll Cardiol. 2011;57:1126–66.CrossRef American College of Cardiology Foundation Appropriate Use Criteria Task Force, American Society of Echocardiography, American Heart Association, American Society of Nuclear Cardiology, Heart Failure Society of America, Heart Rhythm Society, Society for Cardiovascular Angiography and Interventions, Society of Critical Care Medicine, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, Douglas PS, Garcia MJ, Haines DE, Lai WW, Manning WJ, et al. ACCF/ASE/AHA/ASNC/HFSA/HRS/SCAI/SCCM/SCCT/SCMR 2011 Appropriate Use Criteria for Echocardiography. A Report of the American College of Cardiology Foundation Appropriate Use Criteria Task Force, American Society of Echocardiography, American Heart Association, American Society of Nuclear Cardiology, Heart Failure Society of America, Heart Rhythm Society, Society for Cardiovascular Angiography and Interventions, Society of Critical Care Medicine, Society of Cardiovascular Computed Tomography, and Society for Cardiovascular Magnetic Resonance Endorsed by the American College of Chest Physicians. J Am Coll Cardiol. 2011;57:1126–66.CrossRef
20.
Zurück zum Zitat Gramley F, Lorenzen J, Pezzella F, Kettering K, Himmrich E, Plumhans C, et al. Hypoxia and myocardial remodeling in human cardiac allografts: a time-course study. J Heart Lung Transplant. 2009;28:1119–26.CrossRefPubMed Gramley F, Lorenzen J, Pezzella F, Kettering K, Himmrich E, Plumhans C, et al. Hypoxia and myocardial remodeling in human cardiac allografts: a time-course study. J Heart Lung Transplant. 2009;28:1119–26.CrossRefPubMed
21.
Zurück zum Zitat Wieneke H, Zander C, Eising EG, Haude M, Bockisch A, Erbel R. Non-invasive characterization of cardiac microvascular disease by nuclear medicine using single-photon emission tomography. Herz. 1999;24:515–21.CrossRefPubMed Wieneke H, Zander C, Eising EG, Haude M, Bockisch A, Erbel R. Non-invasive characterization of cardiac microvascular disease by nuclear medicine using single-photon emission tomography. Herz. 1999;24:515–21.CrossRefPubMed
22.
Zurück zum Zitat Verna E, Ceriani L, Giovanella L, Binaghi G, Garancini S. “False-positive” myocardial perfusion scintigraphy findings in patients with angiographically normal coronary arteries: insights from intravascular sonography studies. J Nucl Med. 2000;41:1935–40.PubMed Verna E, Ceriani L, Giovanella L, Binaghi G, Garancini S. “False-positive” myocardial perfusion scintigraphy findings in patients with angiographically normal coronary arteries: insights from intravascular sonography studies. J Nucl Med. 2000;41:1935–40.PubMed
23.
Zurück zum Zitat Parodi O, Sambuceti G. The role of coronary microvascular dysfunction in the genesis of cardiovascular diseases. Q J Nucl Med. 1996;40:9–16.PubMed Parodi O, Sambuceti G. The role of coronary microvascular dysfunction in the genesis of cardiovascular diseases. Q J Nucl Med. 1996;40:9–16.PubMed
24.
Zurück zum Zitat Moir S, Hanekom L, Fang ZY, Haluska B, Wong C, Burgess M, et al. Relationship between myocardial perfusion and dysfunction in diabetic cardiomyopathy: a study of quantitative contrast echocardiography and strain rate imaging. Heart. 2006;92:1414–9.PubMedCentralCrossRefPubMed Moir S, Hanekom L, Fang ZY, Haluska B, Wong C, Burgess M, et al. Relationship between myocardial perfusion and dysfunction in diabetic cardiomyopathy: a study of quantitative contrast echocardiography and strain rate imaging. Heart. 2006;92:1414–9.PubMedCentralCrossRefPubMed
25.
Zurück zum Zitat Adameova A, Dhalla NS. Role of microangiopathy in diabetic cardiomyopathy. Heart Fail Rev. 2014;19:25–33.CrossRefPubMed Adameova A, Dhalla NS. Role of microangiopathy in diabetic cardiomyopathy. Heart Fail Rev. 2014;19:25–33.CrossRefPubMed
26.
Zurück zum Zitat Fang ZY, Prins JB, Marwick TH. Diabetic cardiomyopathy: evidence, mechanisms, and therapeutic implications. Endocr Rev. 2004;25:543–67.CrossRefPubMed Fang ZY, Prins JB, Marwick TH. Diabetic cardiomyopathy: evidence, mechanisms, and therapeutic implications. Endocr Rev. 2004;25:543–67.CrossRefPubMed
28.
Zurück zum Zitat Mc Ardle BA, Davies RA, Chen L, Small GR, Ruddy TD, Dwivedi G, et al. Prognostic value of rubidium-82 positron emission tomography in patients after heart transplant. Circ Cardiovasc Imaging. 2014;7:930–7.CrossRefPubMed Mc Ardle BA, Davies RA, Chen L, Small GR, Ruddy TD, Dwivedi G, et al. Prognostic value of rubidium-82 positron emission tomography in patients after heart transplant. Circ Cardiovasc Imaging. 2014;7:930–7.CrossRefPubMed
Metadaten
Titel
Inhomogeneous myocardial stress perfusion in SPECT studies predicts future allograft dysfunction in heart transplant recipients
verfasst von
Christian Wenning
Alexis Vrachimis
Angelo Dell´Aquila
Alvyda Penning
Jörg Stypmann
Michael Schäfers
Publikationsdatum
01.12.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
EJNMMI Research / Ausgabe 1/2015
Elektronische ISSN: 2191-219X
DOI
https://doi.org/10.1186/s13550-015-0129-8

Weitere Artikel der Ausgabe 1/2015

EJNMMI Research 1/2015 Zur Ausgabe