Skip to main content
Erschienen in: Journal of Nuclear Cardiology 3/2010

01.06.2010 | Original Article

Interassay reproducibility of myocardial perfusion gated SPECT in patients with atrial fibrillation

verfasst von: Santiago Aguadé-Bruix, MD, Guillermo Romero-Farina, MD, PhD, FESC, Gemma Cuberas-Borros, PhD, Marta Milà-Lopez, MD, Virginia Pubul-Núñez, MD, Rosa Siurana-Escuer, MD, PhD, David García-Dorado, MD, PhD, FESC, Jaume Candell-Riera, MD, PhD, FESC

Erschienen in: Journal of Nuclear Cardiology | Ausgabe 3/2010

Einloggen, um Zugang zu erhalten

Abstract

Aim

The aim of this study was to assess interassay reproducibility of myocardial perfusion gated-SPECT for calculation of end-diastolic volume (EDV), end-systolic volume (ESV), and left ventricular ejection fraction (LVEF) in patients with atrial fibrillation (AF).

Methods

One hundred and fifteen consecutive patients with AF from three participating hospitals (mean age 68.9 years, 39 women) were included in the study. All patients underwent two image gated acquisitions at rest with a 30 minute interval between them. Quantitative data were obtained using the QGS and ECT software algorithms.

Results

Heart rate was similar in both studies: 74.94 ± 15.2 vs 73.03 ± 15.57. QGS yielded an LVEF of 54.4%/53.8%, an EDV of 100 mL/101.5 mL, and an ESV of 51 mL/52.3 mL; and ECT showed an LVEF of 63.6%/62.9%, an EDV of 125.8 mL/127.4 mL and ESV of 54.1 mL/56.3 mL. Correlation between the two acquisitions was high (>0.948) for both methods for LVEF, EDV and ESV. Regression and Bland-Altman graphics showed a good agreement between all parameters. Interassay variation coefficients for each method (QGS/ECT) were 5.29% vs 4.83% for LVEF, 4.94% vs 5.17% for EDV, and 9.94% vs 12.78% for ESV.

Conclusions

Interassay reproducibility of LVEF and EDV with gated-SPECT in patients with AF is good, whereas for ESV it is suboptimal, particularly when ESV is small.
Literatur
1.
Zurück zum Zitat Castell-Conesa J, Aguadé-Bruix S, García-Burillo A, González JM, Canela T, Oller G, et al. Reproducibilidad de la gated SPECT de perfusión miocárdica en la valoración de la función ventricular y su comparación con la ventriculografía isotópica. Rev Esp Cardiol 2004;57:931-8.CrossRefPubMed Castell-Conesa J, Aguadé-Bruix S, García-Burillo A, González JM, Canela T, Oller G, et al. Reproducibilidad de la gated SPECT de perfusión miocárdica en la valoración de la función ventricular y su comparación con la ventriculografía isotópica. Rev Esp Cardiol 2004;57:931-8.CrossRefPubMed
2.
Zurück zum Zitat Schaefer WM, Lipke CSA, Standke D, Kühl HP, Nowak B, Kaiser HJ, et al. Quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPECT: MRI validation and comparison of the Emory Cardiac Tool Box with QGS and 4D-MSPECT. J Nucl Med 2005;46:1256-63.PubMed Schaefer WM, Lipke CSA, Standke D, Kühl HP, Nowak B, Kaiser HJ, et al. Quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPECT: MRI validation and comparison of the Emory Cardiac Tool Box with QGS and 4D-MSPECT. J Nucl Med 2005;46:1256-63.PubMed
3.
Zurück zum Zitat Iskandrian AE, Germano G, VanDecker W, Ogilby JD, Wolf N, Mintz R, et al. Validation of left ventricular volume measurements by gated SPECT 99mTc-labeled sestamibi imaging. J Nucl Cardiol 1998;5:574-8.CrossRefPubMed Iskandrian AE, Germano G, VanDecker W, Ogilby JD, Wolf N, Mintz R, et al. Validation of left ventricular volume measurements by gated SPECT 99mTc-labeled sestamibi imaging. J Nucl Cardiol 1998;5:574-8.CrossRefPubMed
4.
Zurück zum Zitat Nichols K, Yao SS, Kamran M, Faber TL, Cooke CD, DePuey EG. Clinical impact of arrhythmias on gated SPECT cardiac myocardial perfusion and function assessment. J Nucl Cardiol 2001;8:19-30.CrossRefPubMed Nichols K, Yao SS, Kamran M, Faber TL, Cooke CD, DePuey EG. Clinical impact of arrhythmias on gated SPECT cardiac myocardial perfusion and function assessment. J Nucl Cardiol 2001;8:19-30.CrossRefPubMed
5.
Zurück zum Zitat Strauss HW, Zaret BL, Hurley PJ, Natarajan TK, Pitt B. A scintiphotographic method for measuring left ventricular ejection fraction in man without cardiac catheterization. Am J Cardiol 1971;28:575-80.CrossRefPubMed Strauss HW, Zaret BL, Hurley PJ, Natarajan TK, Pitt B. A scintiphotographic method for measuring left ventricular ejection fraction in man without cardiac catheterization. Am J Cardiol 1971;28:575-80.CrossRefPubMed
6.
Zurück zum Zitat Fleiss JL. The design and analysis of clinical experiments. New York: Wiley; 1986. Fleiss JL. The design and analysis of clinical experiments. New York: Wiley; 1986.
7.
Zurück zum Zitat Williams KA. A historical perspective on measurement of ventricular function with scintigraphic techniques: Part II—Ventricular function with gated techniques for blood pool and perfusion imaging. J Nucl Cardiol 2005;12:208-15.CrossRefPubMed Williams KA. A historical perspective on measurement of ventricular function with scintigraphic techniques: Part II—Ventricular function with gated techniques for blood pool and perfusion imaging. J Nucl Cardiol 2005;12:208-15.CrossRefPubMed
8.
Zurück zum Zitat Ibrahim DY, DiFilippo FP, Steed JE, Cerqueira MD. Optimal SPECT processing and display: Making bad studies look good to get the right answer. J Nucl Cardiol 2006;13:855-66.CrossRefPubMed Ibrahim DY, DiFilippo FP, Steed JE, Cerqueira MD. Optimal SPECT processing and display: Making bad studies look good to get the right answer. J Nucl Cardiol 2006;13:855-66.CrossRefPubMed
9.
Zurück zum Zitat van Aswegen A, Alderson PO, Nickoloff EL, Housholder DF, Wagner HN Jr. Temporal resolution requirements for left ventricular time-activity curves. Radiology 1980;135:165-70.PubMed van Aswegen A, Alderson PO, Nickoloff EL, Housholder DF, Wagner HN Jr. Temporal resolution requirements for left ventricular time-activity curves. Radiology 1980;135:165-70.PubMed
10.
Zurück zum Zitat Cullom SJ, Case JA, Bateman TM. Electrocardiographically gated myocardial perfusion SPECT Technical principles and quality control considerations. J Nucl Cardiol 1998;5:418-25.CrossRefPubMed Cullom SJ, Case JA, Bateman TM. Electrocardiographically gated myocardial perfusion SPECT Technical principles and quality control considerations. J Nucl Cardiol 1998;5:418-25.CrossRefPubMed
11.
Zurück zum Zitat Bacharach SL, Green MV, Bonow RO, Findley SL, Ostrow HG, Johnston GS. Measurement of ventricular function by ECG gating during atrial fibrillation. J Nucl Med 1981;22:226-31.PubMed Bacharach SL, Green MV, Bonow RO, Findley SL, Ostrow HG, Johnston GS. Measurement of ventricular function by ECG gating during atrial fibrillation. J Nucl Med 1981;22:226-31.PubMed
12.
Zurück zum Zitat Small AD, Motherwell DW, Fletcher AM, McCurrach G, Rankin A, Martin W. Assessing ventricular function in patients with atrial fibrillation [abstract]. Nucl Med Commun 2007;28:A2.CrossRef Small AD, Motherwell DW, Fletcher AM, McCurrach G, Rankin A, Martin W. Assessing ventricular function in patients with atrial fibrillation [abstract]. Nucl Med Commun 2007;28:A2.CrossRef
13.
Zurück zum Zitat Small AD, Motherwell DW, Fletcher AM, McCurrach G, Rankin A, Martin W. Can we accurately assess ventricular function in patients with atrial fibrillation [abstract]. J Nucl Cardiol 2007;14:S42.CrossRef Small AD, Motherwell DW, Fletcher AM, McCurrach G, Rankin A, Martin W. Can we accurately assess ventricular function in patients with atrial fibrillation [abstract]. J Nucl Cardiol 2007;14:S42.CrossRef
14.
Zurück zum Zitat Wallis JW, Juni JE, Wu L. Gated cardiac blood pool studies in atrial fibrillation, role of cycle length windowing. Eur J Nucl Med 1991;18:23-7.CrossRefPubMed Wallis JW, Juni JE, Wu L. Gated cardiac blood pool studies in atrial fibrillation, role of cycle length windowing. Eur J Nucl Med 1991;18:23-7.CrossRefPubMed
15.
Zurück zum Zitat Brash HM, Wraith PK, Hannan WJ, Dewhurst NG, Muir AL. The influence of ectopic heart beats in gated ventricular blood-pool studies. J NucI Med 1980;21:391-3. Brash HM, Wraith PK, Hannan WJ, Dewhurst NG, Muir AL. The influence of ectopic heart beats in gated ventricular blood-pool studies. J NucI Med 1980;21:391-3.
16.
Zurück zum Zitat Hoffmann R, von Bardeleben S, ten Cate F, Borges AC, Kasprzak J, Firschke C, et al. Assessment of systolic left ventricular function: A multi-center comparison of cineventriculography, cardiac magnetic resonance imaging, unenhanced and contrast echocardiography. Eur Heart J 2005;26:607-16.CrossRefPubMed Hoffmann R, von Bardeleben S, ten Cate F, Borges AC, Kasprzak J, Firschke C, et al. Assessment of systolic left ventricular function: A multi-center comparison of cineventriculography, cardiac magnetic resonance imaging, unenhanced and contrast echocardiography. Eur Heart J 2005;26:607-16.CrossRefPubMed
18.
Zurück zum Zitat Nichols K, Dorbala S, DePuey EG, Yao SS, Sharma A, Rozanski A. Influence of arrhythmias on gated SPECT myocardial perfusion and function quantification. J Nucl Med 1999;40:924-34.PubMed Nichols K, Dorbala S, DePuey EG, Yao SS, Sharma A, Rozanski A. Influence of arrhythmias on gated SPECT myocardial perfusion and function quantification. J Nucl Med 1999;40:924-34.PubMed
19.
Zurück zum Zitat Hansen CL, Goldstein RA, Akinboboye OO, Berman DS, Botvinick EH, Churchwell KB, et al. American Society of Nuclear Cardiology. Myocardial perfusion and function: Single photon emission computed tomography. J Nucl Cardiol 2007;14:e39-60.CrossRefPubMed Hansen CL, Goldstein RA, Akinboboye OO, Berman DS, Botvinick EH, Churchwell KB, et al. American Society of Nuclear Cardiology. Myocardial perfusion and function: Single photon emission computed tomography. J Nucl Cardiol 2007;14:e39-60.CrossRefPubMed
20.
Zurück zum Zitat Vallejo E, Chaya H, Plancarte G, Victoria D, Bialostozky D. Variability of serial same-day left ventricular ejection fraction using quantitative gated SPECT. J Nucl Cardiol 2002;9:377-84.CrossRefPubMed Vallejo E, Chaya H, Plancarte G, Victoria D, Bialostozky D. Variability of serial same-day left ventricular ejection fraction using quantitative gated SPECT. J Nucl Cardiol 2002;9:377-84.CrossRefPubMed
21.
Zurück zum Zitat Hambye AS, Vervaet A, Dobbeleir A. Variability of left ventricular ejection fraction and volumes with quantitative gated SPECT: Influence of algorithm, pixel size and reconstruction parameters in small and normal-sized hearts. Eur J Nucl Med Mol Imaging 2004;31:1606-13.CrossRefPubMed Hambye AS, Vervaet A, Dobbeleir A. Variability of left ventricular ejection fraction and volumes with quantitative gated SPECT: Influence of algorithm, pixel size and reconstruction parameters in small and normal-sized hearts. Eur J Nucl Med Mol Imaging 2004;31:1606-13.CrossRefPubMed
Metadaten
Titel
Interassay reproducibility of myocardial perfusion gated SPECT in patients with atrial fibrillation
verfasst von
Santiago Aguadé-Bruix, MD
Guillermo Romero-Farina, MD, PhD, FESC
Gemma Cuberas-Borros, PhD
Marta Milà-Lopez, MD
Virginia Pubul-Núñez, MD
Rosa Siurana-Escuer, MD, PhD
David García-Dorado, MD, PhD, FESC
Jaume Candell-Riera, MD, PhD, FESC
Publikationsdatum
01.06.2010
Verlag
Springer-Verlag
Erschienen in
Journal of Nuclear Cardiology / Ausgabe 3/2010
Print ISSN: 1071-3581
Elektronische ISSN: 1532-6551
DOI
https://doi.org/10.1007/s12350-009-9186-6

Weitere Artikel der Ausgabe 3/2010

Journal of Nuclear Cardiology 3/2010 Zur Ausgabe

Letter to the Editor

Letter to the Editor

Das Risiko für Vorhofflimmern in der Bevölkerung steigt

02.05.2024 Vorhofflimmern Nachrichten

Das Risiko, im Lauf des Lebens an Vorhofflimmern zu erkranken, ist in den vergangenen 20 Jahren gestiegen: Laut dänischen Zahlen wird es drei von zehn Personen treffen. Das hat Folgen weit über die Schlaganfallgefährdung hinaus.

VHF-Ablation nützt wohl nur bei reduzierter Auswurfleistung

02.05.2024 Ablationstherapie Nachrichten

Ob die Katheterablation von Vorhofflimmern bei Patienten mit Herzinsuffizienz die Komplikationsraten senkt, scheint davon abzuhängen, ob die Auswurfleistung erhalten ist oder nicht. Das legen die Ergebnisse einer Metaanalyse nahe.

Weniger Extremitätenischämien mit dualer Plättchenhemmung

02.05.2024 Thrombozytenaggregationshemmer Nachrichten

Eine Behandlung mit Ticagrelor zusätzlich zu ASS kann das Risiko für Revaskularisierungen und Amputationen von Extremitäten bei Diabetikern mit stabiler KHK deutlich reduzieren, vor allem für solche mit PAVK. Dafür spricht eine Auswertung der Interventionsstudie THEMIS.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärzte und Psychotherapeuten.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.