Skip to main content
Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy 3/2021

30.04.2020 | KNEE

Intra- and postoperative assessment of femoral component rotation in total knee arthroplasty: an EKA knee expert group clinical review

verfasst von: Paweł Skowronek, Markus Arnold, Christian Starke, Agnieszka Bartyzel, Lukas B. Moser, Michael T. Hirschmann, European Knee Associates (EKA)

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 3/2021

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Malrotation of the femoral component after primary total knee arthroplasty (TKA) is one of the most important problems leading to painful TKA requiring revision surgery.

Methods

A comprehensive systematic review of the literature was performed to present current evidence on how to optimally place the femoral component in TKA. Several landmarks and techniques for intraoperative determination of femoral component placement and examination of their reliability were analyzed.

Results

2806 articles were identified and 21 met the inclusion criteria. As there is no unquestioned gold standard, numerous approaches are possible which come along with specific advantages and disadvantages. In addition, imaging modalities and measurements regarding postoperative femoral component rotation were also investigated. Femoral component rotation measurements on three-dimensional (3D) reconstructed computerised tomography (CT) images displayed intraclass correlation coefficients (ICC) above 0.85, significantly better than those performed in radiographics or two-dimensional (2D) CT images. Thus, 3D CT images to accurately evaluate the femoral prosthetic component rotation are recommended, especially in unsatisfied patients after TKA.

Conclusion

The EKA Femoral Rotation Focus Group has not identified a single best reference method to determine femoral component rotation, but surgeons mostly prefer the measured resection technique using at least two landmarks for cross-checking the rotation.

Level of evidence

III.
Literatur
1.
Zurück zum Zitat Aglietti P, Sensi L, Cuomo P, Ciardullo A (2008) Rotational position of femoral and tibial components in TKA using the femoral transepicondylar axis. Clin Orthop Relat Res 466:2751–2755PubMedPubMedCentral Aglietti P, Sensi L, Cuomo P, Ciardullo A (2008) Rotational position of femoral and tibial components in TKA using the femoral transepicondylar axis. Clin Orthop Relat Res 466:2751–2755PubMedPubMedCentral
2.
Zurück zum Zitat Arima J, Whiteside LA, McCarthy DS, White SE (1995) Femoral rotational alignment, based on the anteroposterior axis, in total knee arthroplasty in a valgus knee. A technical note. J Bone Joint Surg Am 77:1331–1334PubMed Arima J, Whiteside LA, McCarthy DS, White SE (1995) Femoral rotational alignment, based on the anteroposterior axis, in total knee arthroplasty in a valgus knee. A technical note. J Bone Joint Surg Am 77:1331–1334PubMed
3.
Zurück zum Zitat Awengen R, Rasch H, Amsler F, Hirschmann MT (2016) Symptomatic versus asymptomatic knees after bilateral total knee arthroplasty: what is the difference in SPECT/CT? Eur J Nucl Med Mol Imaging 43:762–772PubMed Awengen R, Rasch H, Amsler F, Hirschmann MT (2016) Symptomatic versus asymptomatic knees after bilateral total knee arthroplasty: what is the difference in SPECT/CT? Eur J Nucl Med Mol Imaging 43:762–772PubMed
4.
Zurück zum Zitat Babazadeh S, Dowsey MM, Stoney JD, Choong PFM (2014) Gap balancing sacrifices joint-line maintenance to improve gap symmetry: a randomized controlled trial comparing gap balancing and measured resection. J Arthroplasty 29:950–954PubMed Babazadeh S, Dowsey MM, Stoney JD, Choong PFM (2014) Gap balancing sacrifices joint-line maintenance to improve gap symmetry: a randomized controlled trial comparing gap balancing and measured resection. J Arthroplasty 29:950–954PubMed
5.
Zurück zum Zitat Babazadeh S, Dowsey MM, Vasimalla MG, Stoney JD, Choong PFM (2018) Gap balancing sacrifices joint-line maintenance to improve gap symmetry: 5-year follow-up of a randomized controlled trial. J Arthroplasty 33:75–78PubMed Babazadeh S, Dowsey MM, Vasimalla MG, Stoney JD, Choong PFM (2018) Gap balancing sacrifices joint-line maintenance to improve gap symmetry: 5-year follow-up of a randomized controlled trial. J Arthroplasty 33:75–78PubMed
6.
Zurück zum Zitat Bäthis H, Perlick L, Tingart M, Lüring C, Zurakowski D, Grifka J (2004) Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique. J Bone Joint Surg Br 86:682–687PubMed Bäthis H, Perlick L, Tingart M, Lüring C, Zurakowski D, Grifka J (2004) Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique. J Bone Joint Surg Br 86:682–687PubMed
7.
Zurück zum Zitat Becker R, Malzdorf M, Stärke C, Randolf P, Lohmann C (2012) No difference between tibia-first and femur-first techniques in TKA using computer-assisted surgery. Knee Surg Sports Traumatol Arthrosc 20:2011–2016PubMed Becker R, Malzdorf M, Stärke C, Randolf P, Lohmann C (2012) No difference between tibia-first and femur-first techniques in TKA using computer-assisted surgery. Knee Surg Sports Traumatol Arthrosc 20:2011–2016PubMed
8.
Zurück zum Zitat Berger RA, Rubash HE, Seel MJ, Thompson WH, Crossett LS (1993) Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. Clin Orthop Relat Res 286:40–47 Berger RA, Rubash HE, Seel MJ, Thompson WH, Crossett LS (1993) Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. Clin Orthop Relat Res 286:40–47
9.
Zurück zum Zitat Chao TW, Geraghty L, Dimitriou P, Talbot S (2017) Averaging rotational landmarks during total knee arthroplasty reduces component malrotation caused by femoral asymmetry. J Orthop Surg 12 12(1):74 Chao TW, Geraghty L, Dimitriou P, Talbot S (2017) Averaging rotational landmarks during total knee arthroplasty reduces component malrotation caused by femoral asymmetry. J Orthop Surg 12 12(1):74
10.
Zurück zum Zitat Churchill J, Khlopas A, Sultan A, Harwin S, Mont M (2018) Gap-balancing versus measured resection technique in total knee arthroplasty: a comparison study. J Knee Surg 31:13–16PubMed Churchill J, Khlopas A, Sultan A, Harwin S, Mont M (2018) Gap-balancing versus measured resection technique in total knee arthroplasty: a comparison study. J Knee Surg 31:13–16PubMed
11.
Zurück zum Zitat Cidambi KR, Robertson N, Borges C, Nassif NA, Barnett SL (2018) Intraoperative comparison of measured resection and gap balancing using a force sensor: a prospective, randomized controlled trial. J Arthroplasty 33:S126–S130PubMed Cidambi KR, Robertson N, Borges C, Nassif NA, Barnett SL (2018) Intraoperative comparison of measured resection and gap balancing using a force sensor: a prospective, randomized controlled trial. J Arthroplasty 33:S126–S130PubMed
12.
Zurück zum Zitat Clement ND, Makaram N, Bell J, Tiemessen CH, Mehdi SA, Livingston SJ (2017) Columbus ® computer navigated total knee arthroplasty: gap balancing versus measured resection. Knee 24:1442–1447PubMed Clement ND, Makaram N, Bell J, Tiemessen CH, Mehdi SA, Livingston SJ (2017) Columbus ® computer navigated total knee arthroplasty: gap balancing versus measured resection. Knee 24:1442–1447PubMed
13.
Zurück zum Zitat Cui WQ, Won YY, Baek MH, Kim KK, Cho JH (2006) Variations of the ‘grand-piano sign’ during total knee replacement: a computer-stimulation study. J Bone Joint Surg Br 88(11):1441–1447PubMed Cui WQ, Won YY, Baek MH, Kim KK, Cho JH (2006) Variations of the ‘grand-piano sign’ during total knee replacement: a computer-stimulation study. J Bone Joint Surg Br 88(11):1441–1447PubMed
14.
Zurück zum Zitat Eckhoff DG, Piatt BE, Gnadinger CA, Blaschke RC (1995) Assessing rotational alignment in total knee arthroplasty. Clin Orthop Relat Res 318:176–181 Eckhoff DG, Piatt BE, Gnadinger CA, Blaschke RC (1995) Assessing rotational alignment in total knee arthroplasty. Clin Orthop Relat Res 318:176–181
15.
Zurück zum Zitat Ewald FC (1989) The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res 248:9–12 Ewald FC (1989) The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res 248:9–12
16.
Zurück zum Zitat Griffin FM, Insall JN, Scuderi GR (1998) The posterior condylar angle in osteoarthritic knees. J Arthroplasty 13:812–815PubMed Griffin FM, Insall JN, Scuderi GR (1998) The posterior condylar angle in osteoarthritic knees. J Arthroplasty 13:812–815PubMed
17.
Zurück zum Zitat Hernández-Vaquero D, Noriega-Fernandez A, Perez-Coto I, Sandoval García MA, Sierra-Pereira AA, Roncero-Gonzalez S, Fernandez-Carreira JM (2016) Computed tomography is not necessary to assess rotation of the femoral component in navigation-assisted total knee replacement. J Int Med Res 44:1314–1322PubMedPubMedCentral Hernández-Vaquero D, Noriega-Fernandez A, Perez-Coto I, Sandoval García MA, Sierra-Pereira AA, Roncero-Gonzalez S, Fernandez-Carreira JM (2016) Computed tomography is not necessary to assess rotation of the femoral component in navigation-assisted total knee replacement. J Int Med Res 44:1314–1322PubMedPubMedCentral
18.
Zurück zum Zitat Hirschmann MT, Amsler F, Rasch H (2015) Clinical value of SPECT/CT in the painful total knee arthroplasty (TKA): a prospective study in a consecutive series of 100 TKA. Eur J Nucl Med Mol Imaging 42:1869–1882PubMed Hirschmann MT, Amsler F, Rasch H (2015) Clinical value of SPECT/CT in the painful total knee arthroplasty (TKA): a prospective study in a consecutive series of 100 TKA. Eur J Nucl Med Mol Imaging 42:1869–1882PubMed
19.
Zurück zum Zitat Hirschmann MT, Iranpour F, Konala P, Kerner A, Rasch H, Cobb JP, Friederich NF (2010) A novel standardized algorithm for evaluating patients with painful total knee arthroplasty using combined single photon emission tomography and conventional computerized tomography. Knee Surg Sports Traumatol Arthrosc 18:939–944PubMed Hirschmann MT, Iranpour F, Konala P, Kerner A, Rasch H, Cobb JP, Friederich NF (2010) A novel standardized algorithm for evaluating patients with painful total knee arthroplasty using combined single photon emission tomography and conventional computerized tomography. Knee Surg Sports Traumatol Arthrosc 18:939–944PubMed
20.
Zurück zum Zitat Hirschmann MT, Konala P, Amsler F, Iranpour F, Friederich NF, Cobb JP (2011) The position and orientation of total knee replacement components: a comparison of conventional radiographs, transverse 2D-CT slices and 3D-CT reconstruction. J Bone Joint Surg Br 93:629–633PubMed Hirschmann MT, Konala P, Amsler F, Iranpour F, Friederich NF, Cobb JP (2011) The position and orientation of total knee replacement components: a comparison of conventional radiographs, transverse 2D-CT slices and 3D-CT reconstruction. J Bone Joint Surg Br 93:629–633PubMed
21.
Zurück zum Zitat Hirschmann MT, Konala P, Iranpour F, Kerner A, Rasch H, Friederich NF (2011) Clinical value of SPECT/CT for evaluation of patients with painful knees after total knee arthroplasty—a new dimension of diagnostics? BMC Musculoskelet Disord 12:36PubMedPubMedCentral Hirschmann MT, Konala P, Iranpour F, Kerner A, Rasch H, Friederich NF (2011) Clinical value of SPECT/CT for evaluation of patients with painful knees after total knee arthroplasty—a new dimension of diagnostics? BMC Musculoskelet Disord 12:36PubMedPubMedCentral
23.
Zurück zum Zitat Hommel H, Abdel MP, Perka C (2017) Kinematic femoral alignment with gap balancing and patient-specific instrumentation in total knee arthroplasty: a randomized clinical trial. Eur J Orthop Surg Traumatol 27:683–688PubMed Hommel H, Abdel MP, Perka C (2017) Kinematic femoral alignment with gap balancing and patient-specific instrumentation in total knee arthroplasty: a randomized clinical trial. Eur J Orthop Surg Traumatol 27:683–688PubMed
24.
Zurück zum Zitat Hommel H, Kunze D, Hommel P, Fennema P (2017) Small improvements in postoperative outcome with gap balancing technique compared with measured resection in total knee arthroplasty. Open Orthop J 11:1236–1244PubMedPubMedCentral Hommel H, Kunze D, Hommel P, Fennema P (2017) Small improvements in postoperative outcome with gap balancing technique compared with measured resection in total knee arthroplasty. Open Orthop J 11:1236–1244PubMedPubMedCentral
25.
Zurück zum Zitat Jenny JY, Boeri C (2004) Low reproducibility of the intra-operative measurement of the transepicondylar axis during total knee replacement. Acta Orthop Scand 75:74–77PubMed Jenny JY, Boeri C (2004) Low reproducibility of the intra-operative measurement of the transepicondylar axis during total knee replacement. Acta Orthop Scand 75:74–77PubMed
26.
Zurück zum Zitat Jerosch J, Peuker E, Philipps B, Filler T (2002) Interindividual reproducibility in perioperative rotational alignment of femoral components in knee prosthetic surgery using the transepicondylar axis. Knee Surg Sports Traumatol Arthrosc 10:194–197PubMed Jerosch J, Peuker E, Philipps B, Filler T (2002) Interindividual reproducibility in perioperative rotational alignment of femoral components in knee prosthetic surgery using the transepicondylar axis. Knee Surg Sports Traumatol Arthrosc 10:194–197PubMed
27.
Zurück zum Zitat Kanekasu K, Kondo M, Kadoya Y (2005) Axial radiography of the distal femur to assess rotational alignment in total knee arthroplasty. Clin Orthop Relat Res 434:193–197 Kanekasu K, Kondo M, Kadoya Y (2005) Axial radiography of the distal femur to assess rotational alignment in total knee arthroplasty. Clin Orthop Relat Res 434:193–197
28.
Zurück zum Zitat Katz MA, Beck TD, Silber JS, Seldes RM, Lotke PA (2001) Determining femoral rotational alignment in total knee arthroplasty. J Arthroplasty 16:301–305PubMed Katz MA, Beck TD, Silber JS, Seldes RM, Lotke PA (2001) Determining femoral rotational alignment in total knee arthroplasty. J Arthroplasty 16:301–305PubMed
29.
Zurück zum Zitat Kim C-W, Lee C-R, Gwak H-C, Kim J-H, Kwon Y-U, Kim D-Y (2019) The Effects of surgical technique in total knee arthroplasty for varus osteoarthritic knee on the rotational alignment of femoral component: gap balancing technique versus measured resection technique. J Knee Surg 33(2):144–151PubMed Kim C-W, Lee C-R, Gwak H-C, Kim J-H, Kwon Y-U, Kim D-Y (2019) The Effects of surgical technique in total knee arthroplasty for varus osteoarthritic knee on the rotational alignment of femoral component: gap balancing technique versus measured resection technique. J Knee Surg 33(2):144–151PubMed
30.
Zurück zum Zitat Konigsberg B, Hess R, Hartman C, Smith L, Garvin KL (2014) Inter- and intraobserver reliability of two-dimensional CT scan for total knee arthroplasty component malrotation. Clin Orthop Relat Res 472:212–217PubMed Konigsberg B, Hess R, Hartman C, Smith L, Garvin KL (2014) Inter- and intraobserver reliability of two-dimensional CT scan for total knee arthroplasty component malrotation. Clin Orthop Relat Res 472:212–217PubMed
31.
Zurück zum Zitat Lee D-H, Park J-H, Song D-I, Padhy D, Jeong W-K, Han S-B (2010) Accuracy of soft tissue balancing in TKA: comparison between navigation-assisted gap balancing and conventional measured resection. Knee Surg Sports Traumatol Arthrosc 18:381–387PubMed Lee D-H, Park J-H, Song D-I, Padhy D, Jeong W-K, Han S-B (2010) Accuracy of soft tissue balancing in TKA: comparison between navigation-assisted gap balancing and conventional measured resection. Knee Surg Sports Traumatol Arthrosc 18:381–387PubMed
32.
Zurück zum Zitat Lee HJ, Lee JS, Jung HJ, Song KS, Yang JJ, Park CW (2011) Comparison of joint line position changes after primary bilateral total knee arthroplasty performed using the navigation-assisted measured gap resection or gap balancing techniques. Knee Surg Sports Traumatol Arthrosc 19:2027–2032PubMed Lee HJ, Lee JS, Jung HJ, Song KS, Yang JJ, Park CW (2011) Comparison of joint line position changes after primary bilateral total knee arthroplasty performed using the navigation-assisted measured gap resection or gap balancing techniques. Knee Surg Sports Traumatol Arthrosc 19:2027–2032PubMed
33.
Zurück zum Zitat Lee JK, Lee S, Chun SH, Kim KT, Lee MC (2017) Rotational alignment of femoral component with different methods in total knee arthroplasty: a randomized, controlled trial. BMC Musculoskelet Disord 18:217PubMedPubMedCentral Lee JK, Lee S, Chun SH, Kim KT, Lee MC (2017) Rotational alignment of femoral component with different methods in total knee arthroplasty: a randomized, controlled trial. BMC Musculoskelet Disord 18:217PubMedPubMedCentral
34.
Zurück zum Zitat Mantas JP, Bloebaum RD, Skedros JG, Hofmann AA (1992) Implications of reference axes used for rotational alignment of the femoral component in primary and revision knee arthroplasty. J Arthroplasty 7:531–535PubMed Mantas JP, Bloebaum RD, Skedros JG, Hofmann AA (1992) Implications of reference axes used for rotational alignment of the femoral component in primary and revision knee arthroplasty. J Arthroplasty 7:531–535PubMed
35.
Zurück zum Zitat Matsumoto T, Muratsu H, Kawakami Y, Takayama K, Ishida K, Matsushita T, Akisue T, Nishida K, Kuroda R, Kurosaka M (2014) Soft-tissue balancing in total knee arthroplasty: cruciate-retaining versus posterior-stabilised, and measured-resection versus gap technique. Int Orthop 38:531–537PubMed Matsumoto T, Muratsu H, Kawakami Y, Takayama K, Ishida K, Matsushita T, Akisue T, Nishida K, Kuroda R, Kurosaka M (2014) Soft-tissue balancing in total knee arthroplasty: cruciate-retaining versus posterior-stabilised, and measured-resection versus gap technique. Int Orthop 38:531–537PubMed
36.
Zurück zum Zitat McDougall CJ, Gallie P, Whitehouse SL (2016) Preoperative assessment of femoral rotation and its relationship with coronal alignment: a magnetic resonance imaging study. J Orthop 13:290–293PubMedPubMedCentral McDougall CJ, Gallie P, Whitehouse SL (2016) Preoperative assessment of femoral rotation and its relationship with coronal alignment: a magnetic resonance imaging study. J Orthop 13:290–293PubMedPubMedCentral
37.
Zurück zum Zitat Middleton FR, Palmer SH (2007) How accurate is Whiteside’s line as a reference axis in total knee arthroplasty? Knee 14:204–207PubMed Middleton FR, Palmer SH (2007) How accurate is Whiteside’s line as a reference axis in total knee arthroplasty? Knee 14:204–207PubMed
38.
Zurück zum Zitat Moyad TF, Hughes RE, Urquart A (2011) “Grand piano sign”, a marker for proper femoral component rotation during total knee arthroplasty. Am J Orthop 40:348–352PubMed Moyad TF, Hughes RE, Urquart A (2011) “Grand piano sign”, a marker for proper femoral component rotation during total knee arthroplasty. Am J Orthop 40:348–352PubMed
39.
Zurück zum Zitat Murakami AM, Hash TW, Hepinstall MS, Lyman S, Nestor BJ, Potter HG (2012) MRI evaluation of rotational alignment and synovitis in patients with pain after total knee replacement. J Bone Joint Surg Br 94:1209–1215PubMed Murakami AM, Hash TW, Hepinstall MS, Lyman S, Nestor BJ, Potter HG (2012) MRI evaluation of rotational alignment and synovitis in patients with pain after total knee replacement. J Bone Joint Surg Br 94:1209–1215PubMed
40.
Zurück zum Zitat Nagamine R, Miura H, Inoue Y, Urabe K, Matsuda S, Okamoto Y, Nishizawa M, Iwamoto Y (1998) Reliability of the anteroposterior axis and the posterior condylar axis for determining rotational alignment of the femoral component in total knee arthroplasty. J Orthop Sci 3:194–198PubMed Nagamine R, Miura H, Inoue Y, Urabe K, Matsuda S, Okamoto Y, Nishizawa M, Iwamoto Y (1998) Reliability of the anteroposterior axis and the posterior condylar axis for determining rotational alignment of the femoral component in total knee arthroplasty. J Orthop Sci 3:194–198PubMed
41.
Zurück zum Zitat Nikolaides AP, El K, Papavasiliou KA, Sayegh FE, Tsitouridis L, Kapetanos GA (2014) Measured resection versus gap balancing technique for femoral rotational alignment: a prospective study. J Orthop Surg 22:158–162 Nikolaides AP, El K, Papavasiliou KA, Sayegh FE, Tsitouridis L, Kapetanos GA (2014) Measured resection versus gap balancing technique for femoral rotational alignment: a prospective study. J Orthop Surg 22:158–162
42.
Zurück zum Zitat Ohmori T, Kabata T, Kajino Y, Taga T, Inoue D, Yamamoto T, Takagi T, Yoshitani J, Ueno T, Tsuchiya H (2018) Usefulness of the “grand-piano sign” for determining femoral rotational alignment in total knee arthroplasty. Knee 25:15–24PubMed Ohmori T, Kabata T, Kajino Y, Taga T, Inoue D, Yamamoto T, Takagi T, Yoshitani J, Ueno T, Tsuchiya H (2018) Usefulness of the “grand-piano sign” for determining femoral rotational alignment in total knee arthroplasty. Knee 25:15–24PubMed
43.
Zurück zum Zitat Pang HN, Yeo SJ, Chong HC, Chin PL, Ong J, Lo NN (2011) Computer-assisted gap balancing technique improves outcome in total knee arthroplasty, compared with conventional measured resection technique. Knee Surg Sports Traumatol Arthrosc 19:1496–1503PubMed Pang HN, Yeo SJ, Chong HC, Chin PL, Ong J, Lo NN (2011) Computer-assisted gap balancing technique improves outcome in total knee arthroplasty, compared with conventional measured resection technique. Knee Surg Sports Traumatol Arthrosc 19:1496–1503PubMed
44.
Zurück zum Zitat Paternostre F, Schwab P-E, Thienpont E (2014) The combined Whiteside’s and posterior condylar line as a reliable reference to describe axial distal femoral anatomy in patient-specific instrument planning. Knee Surg Sports Traumatol Arthrosc 22:3054–3059PubMed Paternostre F, Schwab P-E, Thienpont E (2014) The combined Whiteside’s and posterior condylar line as a reliable reference to describe axial distal femoral anatomy in patient-specific instrument planning. Knee Surg Sports Traumatol Arthrosc 22:3054–3059PubMed
45.
Zurück zum Zitat Rasch H, Falkowski AL, Forrer F, Henckel J, Hirschmann MT (2013) 4D-SPECT/CT in orthopaedics: a new method of combined quantitative volumetric 3D analysis of SPECT/CT tracer uptake and component position measurements in patients after total knee arthroplasty. Skeletal Radiol 42:1215–1223PubMed Rasch H, Falkowski AL, Forrer F, Henckel J, Hirschmann MT (2013) 4D-SPECT/CT in orthopaedics: a new method of combined quantitative volumetric 3D analysis of SPECT/CT tracer uptake and component position measurements in patients after total knee arthroplasty. Skeletal Radiol 42:1215–1223PubMed
46.
Zurück zum Zitat Sabbioni G, Rani N, Del Piccolo N, Ben Ayad R, Carubbi C, Tigani D (2011) Gap balancing versus measured resection technique using a mobile-bearing prosthesis in computer-assisted surgery. Musculoskelet Surg 95:25–30PubMed Sabbioni G, Rani N, Del Piccolo N, Ben Ayad R, Carubbi C, Tigani D (2011) Gap balancing versus measured resection technique using a mobile-bearing prosthesis in computer-assisted surgery. Musculoskelet Surg 95:25–30PubMed
47.
Zurück zum Zitat Schiapparelli F-F, Amsler F, Hirschmann MT (2018) Medial parapatellar approach leads to internal rotation of tibial component in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 26:1564–1570PubMed Schiapparelli F-F, Amsler F, Hirschmann MT (2018) Medial parapatellar approach leads to internal rotation of tibial component in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 26:1564–1570PubMed
48.
Zurück zum Zitat Singh VK, Varkey R, Trehan R, Kamat Y, Raghavan R, Adhikari A (2012) Functional outcome after computer-assisted total knee arthroplasty using measured resection versus gap balancing techniques: a randomised controlled study. J Orthop Surg 20:344–347 Singh VK, Varkey R, Trehan R, Kamat Y, Raghavan R, Adhikari A (2012) Functional outcome after computer-assisted total knee arthroplasty using measured resection versus gap balancing techniques: a randomised controlled study. J Orthop Surg 20:344–347
49.
Zurück zum Zitat Slevin O, Hirschmann A, Schiapparelli FF, Amsler F, Huegli RW, Hirschmann MT (2017) Neutral alignment leads to higher knee society scores after total knee arthroplasty in preoperatively non-varus patients: a prospective clinical study using 3D-CT. Knee Surg Sports Traumatol Arthrosc 26:1602–1609PubMed Slevin O, Hirschmann A, Schiapparelli FF, Amsler F, Huegli RW, Hirschmann MT (2017) Neutral alignment leads to higher knee society scores after total knee arthroplasty in preoperatively non-varus patients: a prospective clinical study using 3D-CT. Knee Surg Sports Traumatol Arthrosc 26:1602–1609PubMed
50.
Zurück zum Zitat Slevin O, Schmid FA, Schiapparelli F-F, Rasch H, Amsler F, Hirschmann MT (2017) Coronal femoral TKA position significantly influences in vivo patellar loading in unresurfaced patellae after primary total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 25:3605–3610PubMed Slevin O, Schmid FA, Schiapparelli F-F, Rasch H, Amsler F, Hirschmann MT (2017) Coronal femoral TKA position significantly influences in vivo patellar loading in unresurfaced patellae after primary total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 25:3605–3610PubMed
51.
Zurück zum Zitat Stephens BF, Hakki S, Saleh KJ, Mihalko WM (2014) Clinical alignment variations in total knee arthroplasty with different navigation methods. Knee 21:971–974PubMed Stephens BF, Hakki S, Saleh KJ, Mihalko WM (2014) Clinical alignment variations in total knee arthroplasty with different navigation methods. Knee 21:971–974PubMed
52.
Zurück zum Zitat Stoeckl B, Nogler M, Krismer M, Beimel C, de la Barrera J-LM, Kessler O (2006) Reliability of the transepicondylar axis as an anatomical landmark in total knee arthroplasty. J Arthroplasty 21:878–882PubMed Stoeckl B, Nogler M, Krismer M, Beimel C, de la Barrera J-LM, Kessler O (2006) Reliability of the transepicondylar axis as an anatomical landmark in total knee arthroplasty. J Arthroplasty 21:878–882PubMed
53.
Zurück zum Zitat Talbot S, Dimitriou P, Mullen M, Bartlett J (2015) Referencing the sulcus line of the trochlear groove and removing intraoperative parallax errors improve femoral component rotation in total knee arthroplasty. Knee Surge Sports Traumatol Arthrosc 25:2743–2750 Talbot S, Dimitriou P, Mullen M, Bartlett J (2015) Referencing the sulcus line of the trochlear groove and removing intraoperative parallax errors improve femoral component rotation in total knee arthroplasty. Knee Surge Sports Traumatol Arthrosc 25:2743–2750
54.
Zurück zum Zitat Tanavalee A, Yuktanandana P, Ngarmukos C (2001) Surgical epicondylar axis vs anatomical epicondylar axis for rotational alignment of the femoral component in total knee arthroplasty. J Med Assoc Thai 84(Suppl 1):S401–408PubMed Tanavalee A, Yuktanandana P, Ngarmukos C (2001) Surgical epicondylar axis vs anatomical epicondylar axis for rotational alignment of the femoral component in total knee arthroplasty. J Med Assoc Thai 84(Suppl 1):S401–408PubMed
55.
Zurück zum Zitat Teeter MG, Perry KI, Yuan X, Howard JL, Lanting BA (2017) Contact kinematic differences between gap balanced vs measured resection techniques for single radius posterior-stabilized total knee arthroplasty. J Arthroplasty 32:1834–1838PubMed Teeter MG, Perry KI, Yuan X, Howard JL, Lanting BA (2017) Contact kinematic differences between gap balanced vs measured resection techniques for single radius posterior-stabilized total knee arthroplasty. J Arthroplasty 32:1834–1838PubMed
56.
Zurück zum Zitat Tigani D, Sabbioni G, Ben Ayad R, Filanti M, Rani N, Del Piccolo N (2010) Comparison between two computer-assisted total knee arthroplasty: gap-balancing versus measured resection technique. Knee Surg Sports Traumatol Arthrosc 18:1304–1310PubMed Tigani D, Sabbioni G, Ben Ayad R, Filanti M, Rani N, Del Piccolo N (2010) Comparison between two computer-assisted total knee arthroplasty: gap-balancing versus measured resection technique. Knee Surg Sports Traumatol Arthrosc 18:1304–1310PubMed
57.
Zurück zum Zitat Victor J, Van Doninck D, Labey L, Innocenti B, Parizel PM, Bellemans J (2009) How precise can bony landmarks be determined on a CT scan of the knee? Knee 16:358–365PubMed Victor J, Van Doninck D, Labey L, Innocenti B, Parizel PM, Bellemans J (2009) How precise can bony landmarks be determined on a CT scan of the knee? Knee 16:358–365PubMed
58.
Zurück zum Zitat Viel T, Casin C, Ducellier F, Steiger V, Bigorre N, Bizot P (2013) Is radiographic measurement of distal femoral torsion reliable? Orthop Traumatol Surg Res 99:517–522PubMed Viel T, Casin C, Ducellier F, Steiger V, Bigorre N, Bizot P (2013) Is radiographic measurement of distal femoral torsion reliable? Orthop Traumatol Surg Res 99:517–522PubMed
59.
Zurück zum Zitat Whiteside LA, Arima J (1995) The anteroposterior axis for femoral rotational alignment in valgus total knee arthroplasty. Clin Orthop Relat Res 321:168–172 Whiteside LA, Arima J (1995) The anteroposterior axis for femoral rotational alignment in valgus total knee arthroplasty. Clin Orthop Relat Res 321:168–172
60.
Zurück zum Zitat Yau WP, Leung A, Liu KG, Yan CH, Wong LS, Chiu KY (2008) Errors in the identification of the transepicondylar and anteroposterior axes of the distal femur in total knee replacement using minimally-invasive and conventional approaches: a cadaver study. J Bone Joint Surg Br 90:520–526PubMed Yau WP, Leung A, Liu KG, Yan CH, Wong LS, Chiu KY (2008) Errors in the identification of the transepicondylar and anteroposterior axes of the distal femur in total knee replacement using minimally-invasive and conventional approaches: a cadaver study. J Bone Joint Surg Br 90:520–526PubMed
Metadaten
Titel
Intra- and postoperative assessment of femoral component rotation in total knee arthroplasty: an EKA knee expert group clinical review
verfasst von
Paweł Skowronek
Markus Arnold
Christian Starke
Agnieszka Bartyzel
Lukas B. Moser
Michael T. Hirschmann
European Knee Associates (EKA)
Publikationsdatum
30.04.2020
Verlag
Springer Berlin Heidelberg
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 3/2021
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-020-06006-4

Weitere Artikel der Ausgabe 3/2021

Knee Surgery, Sports Traumatology, Arthroscopy 3/2021 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.