Skip to main content
Erschienen in: Osteoporosis International 5/2003

01.06.2003 | Original Article

A technical and clinical evaluation of digital X-ray radiogrammetry

verfasst von: K. A. Ward, J. Cotton, J. E. Adams

Erschienen in: Osteoporosis International | Ausgabe 5/2003

Einloggen, um Zugang zu erhalten

Abstract.

Skeletal assessment by morphometry at peripheral sites (e.g. metacarpal index), although simple to perform and widely available, was limited by poor precision and technical aspects of radiogrammetry. Digital X-ray radiogrammetry (DXR) uses the principles of this long-established method but applies more sophisticated methodology to overcome these problems. The aims of this study were to (a) investigate the effects of radiographic technique on bone mineral density (BMD) measurement by DXR, (b) compare DXR to dual-energy X-ray absorptiometry (DXA) and single-energy X-ray absorptiometry (SXA) and (c) determine the applicability of DXR in identifying individuals who most appropriately might be referred for axial DXA. Different radiographers performing the radiograph do not adversely affect precision. Precision, unstandardised (CV%) and standardised (sCV%), is good with both double (DF)- and single (SF)-sided emulsion radiographic film, but better with SF (CV% 0.92 vs 1.12 DF; SCV% 1.76 vs 2.93 DF). Repeat analysis precision was determined on SF (CV% 0.24, sCV% 0.55). A significant (p<0.001), systematic difference was found between BMD measured from DF and SF (mean difference 0.017 g/cm2). The overall percentage difference between the methods was 2.98% (range 0.18–5.78%). Correlations between DXR BMD and DXA were moderately good (r=0.56–0.77, p<0.001); with SXA of the forearm they were excellent (r=0.91, p<0.001). The sensitivity and specificity of DXR for detecting women with osteopaenia or osteoporosis (DXA T-score less than −1; World Health Organisation) was determined at the spine [area under curve (AUC)=0.82, standard error (SE)=0.04], femoral neck (AUC=0.84, SE=0.04) and total hip (AUC=0.84, SE=0.04). Based on femoral neck BMD for detection of osteopaenia, a DXR T-score threshold of −1.05 would be appropriate for detection of patients who might benefit most from axial DXA measurements. The DXR is quick and simple to use, having potential for application in a variety of settings as analysis can be performed in a central unit, with radiographs taken in sites over a wide geographical area. Retrospective analysis may also be performed, e.g. on radiographs taken to monitor rheumatoid arthritis. The technique may also provide a simple, widely available and relatively inexpensive method to assess patients at risk of osteopaenia or osteoporosis, and who most appropriately could be referred for axial DXA. This may be particularly relevant in those who suffer low-trauma fractures and attend accident and emergency or fracture clinics, where investigation for osteoporosis is often overlooked.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Barnett E, Nordin B (1960) The radiological diagnosis of osteoporosis. Clin Radiol 11:166–174 Barnett E, Nordin B (1960) The radiological diagnosis of osteoporosis. Clin Radiol 11:166–174
2.
Zurück zum Zitat Meema H (1962) The occurrence of cortical bone atrophy in old age and osteoporosis. J Can Assoc Radiol 13:27–32 Meema H (1962) The occurrence of cortical bone atrophy in old age and osteoporosis. J Can Assoc Radiol 13:27–32
3.
Zurück zum Zitat Meema H, Meema S (1963) Measurable roentgenologic changes in some peripheral bones in senile osteoporosis. J Am Geriatr Soc 11:1170–1182 Meema H, Meema S (1963) Measurable roentgenologic changes in some peripheral bones in senile osteoporosis. J Am Geriatr Soc 11:1170–1182
4.
Zurück zum Zitat Garn S, Poznanski A, Nagy J (1971) Bone measurement in the differential diagnosis of osteopenia and osteoporosis. Radiology 100:509–518 Garn S, Poznanski A, Nagy J (1971) Bone measurement in the differential diagnosis of osteopenia and osteoporosis. Radiology 100:509–518
5.
Zurück zum Zitat Exton-Smith A, Millard P, Payne P, Wheeler E (1969) Method of measuring quantity of bone. Lancet 2:1153–1157 Exton-Smith A, Millard P, Payne P, Wheeler E (1969) Method of measuring quantity of bone. Lancet 2:1153–1157
6.
Zurück zum Zitat Ashby R, Ward K, Mughal M, Adams J (2002) Age related changes in metacarpal morphometry and areal bone mineral density in children assessed by digital X-ray radiogrammetry (DXR). J Bone Miner Res 17:S297 Ashby R, Ward K, Mughal M, Adams J (2002) Age related changes in metacarpal morphometry and areal bone mineral density in children assessed by digital X-ray radiogrammetry (DXR). J Bone Miner Res 17:S297
7.
Zurück zum Zitat Adams P, Davies G,Sweetnam P (1969) Observer error and measurements of the metacarpal. Br J Radiol 42:192–197 Adams P, Davies G,Sweetnam P (1969) Observer error and measurements of the metacarpal. Br J Radiol 42:192–197
8.
Zurück zum Zitat Tovey F Radiographic morphometry and photodensitometry. In: Metabolic bone disease Tovey F Radiographic morphometry and photodensitometry. In: Metabolic bone disease
9.
Zurück zum Zitat Dequeker J (1976) Quantitative radiology: radiogrammetry of cortical bone. Br J Radiol 49:912–920 Dequeker J (1976) Quantitative radiology: radiogrammetry of cortical bone. Br J Radiol 49:912–920
10.
Zurück zum Zitat Saville PD, Heaney RP, Recker RR (1976) Radiogrammetry at four bone sites in normal middle-aged women: their relation to each other, to calcium metabolism and to other biological variables. Clin Orthop Relat Res 307–315 Saville PD, Heaney RP, Recker RR (1976) Radiogrammetry at four bone sites in normal middle-aged women: their relation to each other, to calcium metabolism and to other biological variables. Clin Orthop Relat Res 307–315
11.
Zurück zum Zitat Cootes T, Hill A, Taylor C, Haslam J (1994) The use of active shape models for locating structures in medical images. Image Vision Comput 6:276–285 Cootes T, Hill A, Taylor C, Haslam J (1994) The use of active shape models for locating structures in medical images. Image Vision Comput 6:276–285
12.
Zurück zum Zitat Cootes T, Taylor C, Cooper D, Graham J (1995) Active shape models: their training and application. Comput Vision Image Understanding 1:38–59 Cootes T, Taylor C, Cooper D, Graham J (1995) Active shape models: their training and application. Comput Vision Image Understanding 1:38–59
13.
Zurück zum Zitat Derisquebourg T, Dubois P, Devogelaer J et al. (1994) Automated computerized radiogrammetry of the second metacarpal and its correlation with absorptiometry of the forearm and spine. Calcif Tiss Int 54:461–465 Derisquebourg T, Dubois P, Devogelaer J et al. (1994) Automated computerized radiogrammetry of the second metacarpal and its correlation with absorptiometry of the forearm and spine. Calcif Tiss Int 54:461–465
14.
Zurück zum Zitat Kalla A, Meyers O, Parkyn N, Kotze T (1989) Osteoporosis screening-radiogrammetry revisited. Br J Rheumatol 28:511–517 Kalla A, Meyers O, Parkyn N, Kotze T (1989) Osteoporosis screening-radiogrammetry revisited. Br J Rheumatol 28:511–517
15.
Zurück zum Zitat Jorgensen J, Andersen P, Rosholm A, Bjarnason N (2000) Digital X-ray radiogrammetry: a new appendicular bone densitometric method with high precision. Clin Physiol 20:330–335 Jorgensen J, Andersen P, Rosholm A, Bjarnason N (2000) Digital X-ray radiogrammetry: a new appendicular bone densitometric method with high precision. Clin Physiol 20:330–335
16.
Zurück zum Zitat Hyldstrup L, Jorgensen J, Sorenson T, Baeksgaard L (2001) Response of cortical bone to antiresorptive treatment. Calcif Tiss Int 68:135–139 Hyldstrup L, Jorgensen J, Sorenson T, Baeksgaard L (2001) Response of cortical bone to antiresorptive treatment. Calcif Tiss Int 68:135–139
17.
Zurück zum Zitat European Communities/ European Foundation for Osteoporosis (1998) Building strong bones and preventing fractures. Summary report on osteoporosis in the European Community-Action for Prevention, Germany, pp 3–12 European Communities/ European Foundation for Osteoporosis (1998) Building strong bones and preventing fractures. Summary report on osteoporosis in the European Community-Action for Prevention, Germany, pp 3–12
18.
Zurück zum Zitat National Osteoporosis Society (2001) Position statement on the use of peripheral X-ray absorptiometry in the management of osteoporosis, pp 1–15 National Osteoporosis Society (2001) Position statement on the use of peripheral X-ray absorptiometry in the management of osteoporosis, pp 1–15
19.
Zurück zum Zitat Miller PD, Njeh CF, Jankowski LG, Lenchik L (2002) What are the standards by which bone mass measurement at peripheral skeletal sites should be used in the diagnosis of osteoporosis? J Clin Densitom 5 (Suppl): S39–S45 Miller PD, Njeh CF, Jankowski LG, Lenchik L (2002) What are the standards by which bone mass measurement at peripheral skeletal sites should be used in the diagnosis of osteoporosis? J Clin Densitom 5 (Suppl): S39–S45
20.
Zurück zum Zitat World Health Organization (1994) Assessment of fracture risk and its implication to screening for postmenopausal osteoporosis, WHO, Geneva World Health Organization (1994) Assessment of fracture risk and its implication to screening for postmenopausal osteoporosis, WHO, Geneva
21.
Zurück zum Zitat Okkalides D, Fotakis M (1994) Patient effective dose resulting from radiographic examinations. Br J Radiol 67:564–672 Okkalides D, Fotakis M (1994) Patient effective dose resulting from radiographic examinations. Br J Radiol 67:564–672
22.
Zurück zum Zitat Black D, Palermo L, Sorenson J et al. (2001) A normative reference database study for Pronosco X-posure System. J Clin Densitom 4:5–12 Black D, Palermo L, Sorenson J et al. (2001) A normative reference database study for Pronosco X-posure System. J Clin Densitom 4:5–12
23.
Zurück zum Zitat Pacheco E, Harrison E, Ward K, Lunt M, Adams J (2002) Detection of osteoporosis by dual energy X-ray absorptiometry (DXA) of the calcaneus: Is the WHO criterion applicable? Calcif Tiss Int 70:475–482 Pacheco E, Harrison E, Ward K, Lunt M, Adams J (2002) Detection of osteoporosis by dual energy X-ray absorptiometry (DXA) of the calcaneus: Is the WHO criterion applicable? Calcif Tiss Int 70:475–482
24.
Zurück zum Zitat Gluer C, Blake G, Lu Y et al. (1995) Accurate assessment of precision errors: how to measure the reproducibility of bone densitometry techniques. Osteoporos Int 5:262–270 Gluer C, Blake G, Lu Y et al. (1995) Accurate assessment of precision errors: how to measure the reproducibility of bone densitometry techniques. Osteoporos Int 5:262–270
25.
Zurück zum Zitat Miller C, Herd R, Ramalingam T, Fogelman I, Blake G (1993) Ultrasonic velocity measurements through the calcaneus: Which velocity should be measured? Osteoporos Int 3:31–35 Miller C, Herd R, Ramalingam T, Fogelman I, Blake G (1993) Ultrasonic velocity measurements through the calcaneus: Which velocity should be measured? Osteoporos Int 3:31–35
26.
Zurück zum Zitat Bland J, Altman D (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 307–310 Bland J, Altman D (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 307–310
27.
Zurück zum Zitat Altman D (1999) Practical statistics for medical research. Chapman and Hall/CRC, London Altman D (1999) Practical statistics for medical research. Chapman and Hall/CRC, London
28.
Zurück zum Zitat Rosholm A (2002) X-posure system. Manchester Rosholm A (2002) X-posure system. Manchester
29.
Zurück zum Zitat Faulkner R, Stetten E von, Miller P (1999) Discordance in patient classification using T-scores. J Clin Densitom 2:343–350 Faulkner R, Stetten E von, Miller P (1999) Discordance in patient classification using T-scores. J Clin Densitom 2:343–350
30.
Zurück zum Zitat Kanis JA, Gluer C (2000) An update in the diagnosis and assessment of osteoporosis with densitometry. Osteoporos Int 11:192–202 Kanis JA, Gluer C (2000) An update in the diagnosis and assessment of osteoporosis with densitometry. Osteoporos Int 11:192–202
31.
Zurück zum Zitat Miller P (2000) Controversies in bone mineral density diagnostic classification. Calcif Tiss Int 66:317–319 Miller P (2000) Controversies in bone mineral density diagnostic classification. Calcif Tiss Int 66:317–319
32.
Zurück zum Zitat Bouxsein M, Palermo L, Yeung C, Black D (2002) Digital X-ray radiogrammetry predicts hip, wrist and vertebral fracture risk in elderly women: a prospective analysis from the study of osteoporotic fractures. Osteoporos Int 13:358–365 Bouxsein M, Palermo L, Yeung C, Black D (2002) Digital X-ray radiogrammetry predicts hip, wrist and vertebral fracture risk in elderly women: a prospective analysis from the study of osteoporotic fractures. Osteoporos Int 13:358–365
33.
Zurück zum Zitat Vasireddy S, Haigh C, Reaney L et al. (2002) Digital X-ray radiogrammetry indices, particularly MCI, can predict vertebral fracture risk in osteoporotic women. J Bone Miner Res 17:S186 Vasireddy S, Haigh C, Reaney L et al. (2002) Digital X-ray radiogrammetry indices, particularly MCI, can predict vertebral fracture risk in osteoporotic women. J Bone Miner Res 17:S186
34.
Zurück zum Zitat Haigh C, Reaney L, Adams J et al. (2002) Digital X-ray radiogrammetry indices are sensitive to clodronate treatment in women with osteoporosis. J Bone Miner Res 17:S231 Haigh C, Reaney L, Adams J et al. (2002) Digital X-ray radiogrammetry indices are sensitive to clodronate treatment in women with osteoporosis. J Bone Miner Res 17:S231
Metadaten
Titel
A technical and clinical evaluation of digital X-ray radiogrammetry
verfasst von
K. A. Ward
J. Cotton
J. E. Adams
Publikationsdatum
01.06.2003
Verlag
Springer-Verlag
Erschienen in
Osteoporosis International / Ausgabe 5/2003
Print ISSN: 0937-941X
Elektronische ISSN: 1433-2965
DOI
https://doi.org/10.1007/s00198-003-1386-3

Weitere Artikel der Ausgabe 5/2003

Osteoporosis International 5/2003 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

TEP mit Roboterhilfe führt nicht zu größerer Zufriedenheit

15.05.2024 Knie-TEP Nachrichten

Der Einsatz von Operationsrobotern für den Einbau von Totalendoprothesen des Kniegelenks hat die Präzision der Eingriffe erhöht. Für die postoperative Zufriedenheit der Patienten scheint das aber unerheblich zu sein, wie eine Studie zeigt.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.