Comparison of 16-frame and 8-frame gated SPET imaging for determination of left ventricular volumes and ejection fraction

verfasst von: Sachin M. Navare, Frans J. T. Wackers, Yi-Hwa Liu

Erschienen in: European Journal of Nuclear Medicine and Molecular Imaging | Ausgabe 10/2003

Einloggen, um Zugang zu erhalten

Abstract

Electrocardiographic (ECG) gated single-photon emission tomography (SPET) allows for simultaneous assessment of myocardial perfusion and left ventricular (LV) function. Presently 8-frame per cardiac cycle ECG gating of SPET images is standard. The aim of this study was to compare the effect of 8-frame and 16-frame gated SPET on measurements of LV volumes and to evaluate the effects of the presence of myocardial perfusion defects and of radiotracer dose administered on the calculation of LV volumes. A total of 86 patients underwent technetium-99m SPET myocardial perfusion imaging using 16-frame per cardiac cycle acquisition. Eight-frame gated SPET images were generated by summation of contiguous frames. Left ventricular end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) were calculated from the 16-frame and 8-frame data sets. The patients were divided into groups according to the administered dose of the radiotracer and the size of the perfusion defect. Results. Sixteen frame per cardiac cycle acquisition resulted in significantly larger EDV (122±72 ml vs 115±68 ml, P<0.0001), smaller ESV (64±58.6 ml vs 67.6±59.5 ml, P<0.0001), and higher LVEF (55.3%±18% vs 49%±17.4%, P<0.0001) as compared to 8-frame SPET imaging. This effect was seen regardless of whether a high or a low dose was administered and whether or not significant perfusion defects were present. This study shows that EDV, ESV and LVEF determined by 16-frame gated SPET are significantly different from those determined by 8-frame gated SPET. The radiotracer dose and perfusion defects do not affect estimation of LV parameters by 16-frame gated SPET.
Literatur
1.
Zurück zum Zitat Germano G, Kiat H, Kavanagh PB, et al. Automatic quantification of ejection fraction from gated myocardial perfusion SPECT. J Nucl Med 1995; 36:2138–2147.PubMed Germano G, Kiat H, Kavanagh PB, et al. Automatic quantification of ejection fraction from gated myocardial perfusion SPECT. J Nucl Med 1995; 36:2138–2147.PubMed
2.
Zurück zum Zitat DePuey EG, Nichols K, Dobrinsky C. Left ventricular ejection fraction assessed from gated technetium-99m sestamibi SPECT. J Nucl Med 1993; 34:1871–1876.PubMed DePuey EG, Nichols K, Dobrinsky C. Left ventricular ejection fraction assessed from gated technetium-99m sestamibi SPECT. J Nucl Med 1993; 34:1871–1876.PubMed
3.
Zurück zum Zitat Williams KA, Taillon LA. Left ventricular function in patients with coronary artery disease assessed by gated tomographic myocardial perfusion images: comparison with assessment by contrast ventriculography and first-pass radionuclide angiography. J Am Coll Cardiol 1996; 27:173–181.CrossRefPubMed Williams KA, Taillon LA. Left ventricular function in patients with coronary artery disease assessed by gated tomographic myocardial perfusion images: comparison with assessment by contrast ventriculography and first-pass radionuclide angiography. J Am Coll Cardiol 1996; 27:173–181.CrossRefPubMed
4.
Zurück zum Zitat Mannting F, Morgan-Mannting MG. Gated SPECT with technetium-99m-sestamibi for assessment of myocardial perfusion abnormalities. J Nucl Med 1993; 34:601–608.PubMed Mannting F, Morgan-Mannting MG. Gated SPECT with technetium-99m-sestamibi for assessment of myocardial perfusion abnormalities. J Nucl Med 1993; 34:601–608.PubMed
5.
Zurück zum Zitat Smith WH, Kastner RJ, Calnon DA, Segalla D, Beller GA, Watson DD. Quantitative gated single photon emission computed tomography imaging: a count based method for display and measurement of regional and global ventricular systolic function. J Nucl Cardiol 1997; 4:451–463.PubMed Smith WH, Kastner RJ, Calnon DA, Segalla D, Beller GA, Watson DD. Quantitative gated single photon emission computed tomography imaging: a count based method for display and measurement of regional and global ventricular systolic function. J Nucl Cardiol 1997; 4:451–463.PubMed
6.
Zurück zum Zitat Calnon DA, Kastner RJ, Smith WH, Segalla D, Beller GA, Watson DD. Validation of a new count based gated single photon emission computed tomography method for quantifying left ventricular systolic function: comparison with equilibrium radionuclide angiography. J Nucl Cardiol 1997; 4:464–471.PubMed Calnon DA, Kastner RJ, Smith WH, Segalla D, Beller GA, Watson DD. Validation of a new count based gated single photon emission computed tomography method for quantifying left ventricular systolic function: comparison with equilibrium radionuclide angiography. J Nucl Cardiol 1997; 4:464–471.PubMed
7.
Zurück zum Zitat Faber TL, Cooke CD, Folks RD, et al. Left ventricular function and perfusion from gated SPECT perfusion images: an integrated method. J Nucl Med 1999; 40:650–659.PubMed Faber TL, Cooke CD, Folks RD, et al. Left ventricular function and perfusion from gated SPECT perfusion images: an integrated method. J Nucl Med 1999; 40:650–659.PubMed
8.
Zurück zum Zitat Ziffer J, Cooke CD, Folks RD, LaPidus A, Alzaraki N, Garcia EV. Quantitative myocardial thickening assessed with sestamibi: clinical evaluation of a count based method [abstract]. J Nucl Med 1991; 32 (Suppl):1006. Ziffer J, Cooke CD, Folks RD, LaPidus A, Alzaraki N, Garcia EV. Quantitative myocardial thickening assessed with sestamibi: clinical evaluation of a count based method [abstract]. J Nucl Med 1991; 32 (Suppl):1006.
9.
Zurück zum Zitat Cooke CD, Garcia EV, Cullom SJ, et al. Determining the accuracy of calculating systolic wall thickening using a fast Fourier transform approximation: a simulation study based on canine and patient data. J Nucl Med 1994; 35:1185–1192.PubMed Cooke CD, Garcia EV, Cullom SJ, et al. Determining the accuracy of calculating systolic wall thickening using a fast Fourier transform approximation: a simulation study based on canine and patient data. J Nucl Med 1994; 35:1185–1192.PubMed
10.
Zurück zum Zitat DePuey EG, Rozanski A. Using gated technetium 99m sestamibi SPECT to characterize fixed myocardial defects as infarct or artifact. J Nucl Med 1995; 36:952–955.PubMed DePuey EG, Rozanski A. Using gated technetium 99m sestamibi SPECT to characterize fixed myocardial defects as infarct or artifact. J Nucl Med 1995; 36:952–955.PubMed
11.
Zurück zum Zitat Mochizuki T, Murase K, Tanaka H, Kondoh T, Hamamoto K, Tauxe WN. Assessment of left ventricular volume using ECG-gated SPECT with technetium-99m-MIBI and technetium-99m-tetrofosmin. J Nucl Med 1997; 38:53–57.PubMed Mochizuki T, Murase K, Tanaka H, Kondoh T, Hamamoto K, Tauxe WN. Assessment of left ventricular volume using ECG-gated SPECT with technetium-99m-MIBI and technetium-99m-tetrofosmin. J Nucl Med 1997; 38:53–57.PubMed
12.
Zurück zum Zitat Vaduganathan P, He ZX, Vick GW III, Mahmarian JJ, Verani MS. Evaluation of left ventricular wall motion, volumes and ejection fraction by gated myocardial tomography with technetium 99m-labelled tetrofosmin: a comparison with cine magnetic resonance imaging. J Nucl Cardiol 1999; 6:3–10.PubMed Vaduganathan P, He ZX, Vick GW III, Mahmarian JJ, Verani MS. Evaluation of left ventricular wall motion, volumes and ejection fraction by gated myocardial tomography with technetium 99m-labelled tetrofosmin: a comparison with cine magnetic resonance imaging. J Nucl Cardiol 1999; 6:3–10.PubMed
13.
Zurück zum Zitat Atsma DE, Kayser HWM, Croon C, et al. Good correlation between left ventricular ejection fraction, end systolic and end diastolic volume measured by gated SPECT as compared to magnetic resonance imaging [abstract]. J Am Coll Cardiol 1999; 33 (Suppl):436A. Atsma DE, Kayser HWM, Croon C, et al. Good correlation between left ventricular ejection fraction, end systolic and end diastolic volume measured by gated SPECT as compared to magnetic resonance imaging [abstract]. J Am Coll Cardiol 1999; 33 (Suppl):436A.
14.
Zurück zum Zitat Iskandrian AE, Germano G, VanDecker W, et al. Validation of left ventricular volume measurements by gated SPECT99mTc-labeled sestamibi imaging. J Nucl Med 1998; 5:574–578. Iskandrian AE, Germano G, VanDecker W, et al. Validation of left ventricular volume measurements by gated SPECT99mTc-labeled sestamibi imaging. J Nucl Med 1998; 5:574–578.
15.
Zurück zum Zitat Germano G, VanDecker W, Mintz R, et al. Validation of left ventricular volumes automatically measured with gated myocardial perfusion SPECT [abstract]. J Am Coll Cardiol 1998; 31 (Suppl):43A. Germano G, VanDecker W, Mintz R, et al. Validation of left ventricular volumes automatically measured with gated myocardial perfusion SPECT [abstract]. J Am Coll Cardiol 1998; 31 (Suppl):43A.
16.
Zurück zum Zitat Yoshiko J, Hasegawa S, Yamaguchi H, et al. Left ventricular volumes and ejection fraction calculated from quantitative electrocardiographic-gated99mTc-Tetrofosmin myocardial SPECT. J Nucl Med 1999; 40:1693–1698. Yoshiko J, Hasegawa S, Yamaguchi H, et al. Left ventricular volumes and ejection fraction calculated from quantitative electrocardiographic-gated99mTc-Tetrofosmin myocardial SPECT. J Nucl Med 1999; 40:1693–1698.
17.
Zurück zum Zitat Mathew D, Zabrodina Y, Mannting F. Volumetric and functional analysis of left ventricle by gated SPECT: a comparison with echocardiographic measurements [abstract]. J Am Coll Cardiol 1998; 31 (Suppl):44A. Mathew D, Zabrodina Y, Mannting F. Volumetric and functional analysis of left ventricle by gated SPECT: a comparison with echocardiographic measurements [abstract]. J Am Coll Cardiol 1998; 31 (Suppl):44A.
18.
Zurück zum Zitat Nichols K, Tamis J, DePeuy EG, Meires J, Malhotra S, Rozanski A. Relationship of gated SPECT ventricular function parameters to angiographic measurements. J Nucl Cardiol 1998; 5:295–303.PubMed Nichols K, Tamis J, DePeuy EG, Meires J, Malhotra S, Rozanski A. Relationship of gated SPECT ventricular function parameters to angiographic measurements. J Nucl Cardiol 1998; 5:295–303.PubMed
19.
Zurück zum Zitat Kumita S, Cho K, Nakajo H, et al. Assessment of left ventricular diastolic function with electrocardiography-gated myocardial perfusion SPECT: comparison with multigated equilibrium radionuclide angiography. J Nucl Cardiol 2001; 8:568–574. Kumita S, Cho K, Nakajo H, et al. Assessment of left ventricular diastolic function with electrocardiography-gated myocardial perfusion SPECT: comparison with multigated equilibrium radionuclide angiography. J Nucl Cardiol 2001; 8:568–574.
20.
Zurück zum Zitat Liu YH, Sinusas AJ, DeMan P, Zaret BL, Wackers FJT. Quantification of SPECT myocardial perfusion images: methodology and validation of the Yale-CQ method. J Nucl Cardiol 1999; 6:190–204.PubMed Liu YH, Sinusas AJ, DeMan P, Zaret BL, Wackers FJT. Quantification of SPECT myocardial perfusion images: methodology and validation of the Yale-CQ method. J Nucl Cardiol 1999; 6:190–204.PubMed
21.
Zurück zum Zitat Liu YH. A new approach of quantification of left ventricular volume for gated SPECT imaging: preliminary validation using a Phantom [abstract]. J Nucl Cardiol 2001; 8:S61. Liu YH. A new approach of quantification of left ventricular volume for gated SPECT imaging: preliminary validation using a Phantom [abstract]. J Nucl Cardiol 2001; 8:S61.
22.
Zurück zum Zitat Liu YH, Harrell CR, Tsatkin V, et al. Evaluation of a new quantification method for gated SPECT imaging: comparison with the quantitative gated SPECT (QGS) method in patients [abstract]. J Nucl Cardiol 2001; 8:S65. Liu YH, Harrell CR, Tsatkin V, et al. Evaluation of a new quantification method for gated SPECT imaging: comparison with the quantitative gated SPECT (QGS) method in patients [abstract]. J Nucl Cardiol 2001; 8:S65.
23.
Zurück zum Zitat Lam PT, Wackers FJT, Liu YH. Validation of a new method for quantification of left ventricular function from ECG-gated SPECT [abstract]. J Nucl Med 2001; 42:93P. Lam PT, Wackers FJT, Liu YH. Validation of a new method for quantification of left ventricular function from ECG-gated SPECT [abstract]. J Nucl Med 2001; 42:93P.
24.
Zurück zum Zitat Hwang WS, Fernando GP, Natale D,et al. Comparison and validation of 3 gated SPECT programs for volume determination using ventricular casts of excised canine hearts [abstract]. J Nucl Med 2001; 42:46P. Hwang WS, Fernando GP, Natale D,et al. Comparison and validation of 3 gated SPECT programs for volume determination using ventricular casts of excised canine hearts [abstract]. J Nucl Med 2001; 42:46P.
25.
Zurück zum Zitat Tou JT, Gonzalez RC. Pattern recognition principles. Reading, Mass.: Addison-Wesley, 1974. Tou JT, Gonzalez RC. Pattern recognition principles. Reading, Mass.: Addison-Wesley, 1974.
26.
Zurück zum Zitat Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; i:307–310. Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; i:307–310.
27.
Zurück zum Zitat Vallejo E, Dione DP, Bruni WL, et al. Reproducibility and accuracy of gated SPECT for determination of left ventricular volumes and ejection fraction: experimental validation using MRI. J Nucl Med 2000; 41:874–882.PubMed Vallejo E, Dione DP, Bruni WL, et al. Reproducibility and accuracy of gated SPECT for determination of left ventricular volumes and ejection fraction: experimental validation using MRI. J Nucl Med 2000; 41:874–882.PubMed
28.
Zurück zum Zitat Everaert H, Bossuyt A, Franken PR. Left ventricular ejection fraction and volumes from gated single photon emission tomographic myocardial perfusion images: comparison between two algorithms working in three-dimensional space. J Nucl Cardiol 1997; 4:472–476.PubMed Everaert H, Bossuyt A, Franken PR. Left ventricular ejection fraction and volumes from gated single photon emission tomographic myocardial perfusion images: comparison between two algorithms working in three-dimensional space. J Nucl Cardiol 1997; 4:472–476.PubMed
29.
Zurück zum Zitat Chua T, Yin LC, Thiang TH, Choo TB, Ping DZ, Leng LY. Accuracy of the automated assessment of left ventricular function with gated perfusion SPECT in the presence of perfusion defects and left ventricular dysfunction: correlation with equilibrium radionuclide ventriculography and echocardiography. J Nucl Cardiol 2000; 7:301–311.PubMed Chua T, Yin LC, Thiang TH, Choo TB, Ping DZ, Leng LY. Accuracy of the automated assessment of left ventricular function with gated perfusion SPECT in the presence of perfusion defects and left ventricular dysfunction: correlation with equilibrium radionuclide ventriculography and echocardiography. J Nucl Cardiol 2000; 7:301–311.PubMed
30.
Zurück zum Zitat Manrique A, Faraggi A, Vera P, Vilain D, Lebtahi R, Cribier A, Le Guludec D.201Tl and 99mTc-MIBI gated SPECT in patients with large perfusion defects and left ventricular dysfunction: comparison with equilibrium radionuclide angiography. J Nucl Med 1999; 40:805–809. Manrique A, Faraggi A, Vera P, Vilain D, Lebtahi R, Cribier A, Le Guludec D.201Tl and 99mTc-MIBI gated SPECT in patients with large perfusion defects and left ventricular dysfunction: comparison with equilibrium radionuclide angiography. J Nucl Med 1999; 40:805–809.
31.
Zurück zum Zitat White HD, Norris RM, Brown MA, Brandt PW, Whitlock RM, Wild CJ. Left ventricular end-systolic volume as the major determinant of survival after recovery from myocardial infarction. Circulation 1987; 76:44–51.PubMed White HD, Norris RM, Brown MA, Brandt PW, Whitlock RM, Wild CJ. Left ventricular end-systolic volume as the major determinant of survival after recovery from myocardial infarction. Circulation 1987; 76:44–51.PubMed
32.
Zurück zum Zitat Hamer AW, Takayama M, Abraham KA, et al. End-systolic volume and long term survival after coronary artery bypass graft surgery in patients with impaired left ventricular function. Circulation 1994; 90:2899–2904.PubMed Hamer AW, Takayama M, Abraham KA, et al. End-systolic volume and long term survival after coronary artery bypass graft surgery in patients with impaired left ventricular function. Circulation 1994; 90:2899–2904.PubMed
33.
Zurück zum Zitat Sharir T, Germano G, Kavanagh PB, et al. Incremental prognostic value of post-stress left ventricular ejection fraction and volume by gated myocardial perfusion single photon emission computed tomography. Circulation 1999; 100:1035–1042.PubMed Sharir T, Germano G, Kavanagh PB, et al. Incremental prognostic value of post-stress left ventricular ejection fraction and volume by gated myocardial perfusion single photon emission computed tomography. Circulation 1999; 100:1035–1042.PubMed
Metadaten
Titel
Comparison of 16-frame and 8-frame gated SPET imaging for determination of left ventricular volumes and ejection fraction
verfasst von
Sachin M. Navare
Frans J. T. Wackers
Yi-Hwa Liu
Publikationsdatum
01.10.2003
Verlag
Springer-Verlag
Erschienen in
European Journal of Nuclear Medicine and Molecular Imaging / Ausgabe 10/2003
Print ISSN: 1619-7070
Elektronische ISSN: 1619-7089
DOI
https://doi.org/10.1007/s00259-003-1231-0

Weitere Artikel der Ausgabe 10/2003

European Journal of Nuclear Medicine and Molecular Imaging 10/2003 Zur Ausgabe