Abstract

Between 2004 and 2009, 60 patients with proximal tibial fractures were included in this prospective study. All fractures were treated with the polyaxial locked-plate fixation system (DePuy, Warsaw, IN, USA). Clinical and radiographic data, including fracture pattern, changes in alignment, local and systemic complications, hardware failure and fracture union were analysed. The mean follow-up was 14 (12–36) months. According to the Orthopaedic Trauma Association (OTA) classification, there were five 41-A, 28 41-B and 27 41-C fractures. Fractures were treated percutaneously in 30% of cases. Double-plating was used in 11 cases. All but three fractures progressed to union at a mean of 3.2 (2.5–5) months. There was no evidence of varus collapse as a result of polyaxial screw failure. No plate fractured, and no screw cut out was noted. There was one case of lateral joint collapse (>10°) in a patient with open bicondylar plateau fracture. The mean Knee Society Score at the time of final follow-up was 91 points, and the mean functional score was 89 points. The polyaxial locking-plate system provided stable fixation of extra-articular and intra-articular proximal tibial fractures and good functional outcomes with a low complication rate.
Literatur
1.
Zurück zum Zitat Bono CM, Levine RG, Rao JP, Behrens FF (2001) "Nonarticular proximal tibia fractures: treatment options and decision making". J Am Acad Orthop Surg 9:176–186PubMed Bono CM, Levine RG, Rao JP, Behrens FF (2001) "Nonarticular proximal tibia fractures: treatment options and decision making". J Am Acad Orthop Surg 9:176–186PubMed
2.
Zurück zum Zitat Pogliacomi F, Verdano MA, Frattini M, Costantino C, Vaienti E, Soncini G (2005) "Combined arthroscopic and radioscopic management of tibial plateau fractures: report of 18 clinical cases". Acta Biomed 76:107–114PubMed Pogliacomi F, Verdano MA, Frattini M, Costantino C, Vaienti E, Soncini G (2005) "Combined arthroscopic and radioscopic management of tibial plateau fractures: report of 18 clinical cases". Acta Biomed 76:107–114PubMed
3.
Zurück zum Zitat Mallik AR, Covall DJ, Whitelaw GP (1992) "Internal versus external fixation of bicondylar tibial plateau fractures". Orthop Rev 21:1433–1436PubMed Mallik AR, Covall DJ, Whitelaw GP (1992) "Internal versus external fixation of bicondylar tibial plateau fractures". Orthop Rev 21:1433–1436PubMed
4.
Zurück zum Zitat Schutz M, Sudkamp NP (2003) "Revolution in plate osteosynthesis: new internal fixator systems". J Orthop Sci 8:252–258PubMedCrossRef Schutz M, Sudkamp NP (2003) "Revolution in plate osteosynthesis: new internal fixator systems". J Orthop Sci 8:252–258PubMedCrossRef
5.
Zurück zum Zitat Baumgaertel F, Buhl M, Rahn BA (1998) "Fracture healing in biological plate osteosynthesis". Injury 29(Suppl 3):C3–C6PubMedCrossRef Baumgaertel F, Buhl M, Rahn BA (1998) "Fracture healing in biological plate osteosynthesis". Injury 29(Suppl 3):C3–C6PubMedCrossRef
6.
Zurück zum Zitat Haidukewych G, Sems SA, Huebner D, Horwitz D, Levy B (2007) "Results of polyaxial locked-plate fixation of periarticular fractures of the knee". J Bone Joint Surg Am 89:614–620PubMedCrossRef Haidukewych G, Sems SA, Huebner D, Horwitz D, Levy B (2007) "Results of polyaxial locked-plate fixation of periarticular fractures of the knee". J Bone Joint Surg Am 89:614–620PubMedCrossRef
7.
Zurück zum Zitat Gustilo RB, Anderson JT (1976) "Prevention of infection in the treatment of one thousand and twenty-five open fractures of long bones: retrospective and prospective analyses". J Bone Joint Surg Am 58:453–458PubMed Gustilo RB, Anderson JT (1976) "Prevention of infection in the treatment of one thousand and twenty-five open fractures of long bones: retrospective and prospective analyses". J Bone Joint Surg Am 58:453–458PubMed
8.
Zurück zum Zitat Yu B, Han K, Ma H, Zhang C, Su J, Zhao J, Li J, Bai Y, Tang H (2009) "Treatment of tibial plateau fractures with high strength injectable calcium sulphate". Int Orthop 33:1127–1133PubMedCrossRef Yu B, Han K, Ma H, Zhang C, Su J, Zhao J, Li J, Bai Y, Tang H (2009) "Treatment of tibial plateau fractures with high strength injectable calcium sulphate". Int Orthop 33:1127–1133PubMedCrossRef
9.
Zurück zum Zitat Stevens DG, Beharry R, McKee MD, Waddell JP, Schemitsch EH (2001) "The long-term functional outcome of operatively treated tibial plateau fractures". J Orthop Trauma 15:312–320PubMedCrossRef Stevens DG, Beharry R, McKee MD, Waddell JP, Schemitsch EH (2001) "The long-term functional outcome of operatively treated tibial plateau fractures". J Orthop Trauma 15:312–320PubMedCrossRef
10.
Zurück zum Zitat P. F. Lachiewicz and T. Funcik, (1990) "Factors influencing the results of open reduction and internal fixation of tibial plateau fractures" Clin Orthop Relat Res: 210-215. P. F. Lachiewicz and T. Funcik, (1990) "Factors influencing the results of open reduction and internal fixation of tibial plateau fractures" Clin Orthop Relat Res: 210-215.
11.
Zurück zum Zitat Greiwe RM, Archdeacon MT (2007) "Locking plate technology: current concepts". J Knee Surg 20:50–55PubMed Greiwe RM, Archdeacon MT (2007) "Locking plate technology: current concepts". J Knee Surg 20:50–55PubMed
12.
Zurück zum Zitat Fulkerson E, Egol KA, Kubiak EN, Liporace F, Kummer FJ, Koval KJ (2006) "Fixation of diaphyseal fractures with a segmental defect: a biomechanical comparison of locked and conventional plating techniques". J Trauma 60:830–835PubMedCrossRef Fulkerson E, Egol KA, Kubiak EN, Liporace F, Kummer FJ, Koval KJ (2006) "Fixation of diaphyseal fractures with a segmental defect: a biomechanical comparison of locked and conventional plating techniques". J Trauma 60:830–835PubMedCrossRef
13.
Zurück zum Zitat Smith WR, Ziran BH, Anglen JO, Stahel PF (2007) "Locking plates: tips and tricks". J Bone Joint Surg Am 89:2298–2307PubMedCrossRef Smith WR, Ziran BH, Anglen JO, Stahel PF (2007) "Locking plates: tips and tricks". J Bone Joint Surg Am 89:2298–2307PubMedCrossRef
14.
Zurück zum Zitat Singh S, Patel PR, Joshi AK, Naik RN, Nagaraj C, Kumar S (2009) "Biological approach to treatment of intra-articular proximal tibial fractures with double osteosynthesis". Int Orthop 33:271–274PubMedCrossRef Singh S, Patel PR, Joshi AK, Naik RN, Nagaraj C, Kumar S (2009) "Biological approach to treatment of intra-articular proximal tibial fractures with double osteosynthesis". Int Orthop 33:271–274PubMedCrossRef
15.
Zurück zum Zitat Phisitkul P, McKinley TO, Nepola JV, Marsh JL (2007) "Complications of locking plate fixation in complex proximal tibia injuries". J Orthop Trauma 21:83–91PubMedCrossRef Phisitkul P, McKinley TO, Nepola JV, Marsh JL (2007) "Complications of locking plate fixation in complex proximal tibia injuries". J Orthop Trauma 21:83–91PubMedCrossRef
16.
Zurück zum Zitat Gosling T, Schandelmaier P, Muller M, Hankemeier S, Wagner M, Krettek C (2005) "Single lateral locked screw plating of bicondylar tibial plateau fractures". Clin Orthop Relat Res 439:207–214PubMedCrossRef Gosling T, Schandelmaier P, Muller M, Hankemeier S, Wagner M, Krettek C (2005) "Single lateral locked screw plating of bicondylar tibial plateau fractures". Clin Orthop Relat Res 439:207–214PubMedCrossRef
17.
Zurück zum Zitat Jiang R, Luo CF, Wang MC, Yang TY, Zeng BF (2008) "A comparative study of Less Invasive Stabilization System (LISS) fixation and two-incision double plating for the treatment of bicondylar tibial plateau fractures". Knee 15:139–143PubMedCrossRef Jiang R, Luo CF, Wang MC, Yang TY, Zeng BF (2008) "A comparative study of Less Invasive Stabilization System (LISS) fixation and two-incision double plating for the treatment of bicondylar tibial plateau fractures". Knee 15:139–143PubMedCrossRef
18.
Zurück zum Zitat Stannard JP, Wilson TC, Volgas DA, Alonso JE (2004) "The less invasive stabilization system in the treatment of complex fractures of the tibial plateau: short-term results". J Orthop Trauma 18:552–558PubMedCrossRef Stannard JP, Wilson TC, Volgas DA, Alonso JE (2004) "The less invasive stabilization system in the treatment of complex fractures of the tibial plateau: short-term results". J Orthop Trauma 18:552–558PubMedCrossRef
19.
Zurück zum Zitat Egol KA, Su E, Tejwani NC, Sims SH, Kummer FJ, Koval KJ (2004) "Treatment of complex tibial plateau fractures using the less invasive stabilization system plate: clinical experience and a laboratory comparison with double plating". J Trauma 57:340–346PubMedCrossRef Egol KA, Su E, Tejwani NC, Sims SH, Kummer FJ, Koval KJ (2004) "Treatment of complex tibial plateau fractures using the less invasive stabilization system plate: clinical experience and a laboratory comparison with double plating". J Trauma 57:340–346PubMedCrossRef
20.
Zurück zum Zitat Ratcliff JR, Werner FW, Green JK, Harley BJ (2007) "Medial buttress versus lateral locked plating in a cadaver medial tibial plateau fracture model". J Orthop Trauma 21:444–448PubMedCrossRef Ratcliff JR, Werner FW, Green JK, Harley BJ (2007) "Medial buttress versus lateral locked plating in a cadaver medial tibial plateau fracture model". J Orthop Trauma 21:444–448PubMedCrossRef
21.
Zurück zum Zitat Bansal MR, Bhagat SB, Shukla DD (2009) "Bovine cancellous xenograft in the treatment of tibial plateau fractures in elderly patients". Int Orthop 33:779–784PubMedCrossRef Bansal MR, Bhagat SB, Shukla DD (2009) "Bovine cancellous xenograft in the treatment of tibial plateau fractures in elderly patients". Int Orthop 33:779–784PubMedCrossRef
22.
Zurück zum Zitat Muggler E, Huber D, Burri C (1975) "[Results of surgical treatment of 225 tibial-head fractures]". Chirurg 46:348–352PubMed Muggler E, Huber D, Burri C (1975) "[Results of surgical treatment of 225 tibial-head fractures]". Chirurg 46:348–352PubMed
23.
Zurück zum Zitat Boldin C, Fankhauser F, Hofer HP, Szyszkowitz R (2006) "Three-year results of proximal tibia fractures treated with the LISS". Clin Orthop Relat Res 445:222–229PubMed Boldin C, Fankhauser F, Hofer HP, Szyszkowitz R (2006) "Three-year results of proximal tibia fractures treated with the LISS". Clin Orthop Relat Res 445:222–229PubMed
24.
Zurück zum Zitat Benirschke SK, Agnew SG, Mayo KA, Santoro VM, Henley MB (1992) "Immediate internal fixation of open, complex tibial plateau fractures: treatment by a standard protocol". J Orthop Trauma 6:78–86PubMed Benirschke SK, Agnew SG, Mayo KA, Santoro VM, Henley MB (1992) "Immediate internal fixation of open, complex tibial plateau fractures: treatment by a standard protocol". J Orthop Trauma 6:78–86PubMed
25.
Zurück zum Zitat Manidakis N, Dosani A, Dimitriou R, Stengel D, Matthews S, Giannoudis P (2010) "Tibial plateau fractures: functional outcome and incidence of osteoarthritis in 125 cases". Int Orthop 34:565–570PubMedCrossRef Manidakis N, Dosani A, Dimitriou R, Stengel D, Matthews S, Giannoudis P (2010) "Tibial plateau fractures: functional outcome and incidence of osteoarthritis in 125 cases". Int Orthop 34:565–570PubMedCrossRef
Metadaten
Titel
Proximal tibial fractures: early experience using polyaxial locking-plate technology
verfasst von
Vassilios S. Nikolaou
Hiang Boon Tan
George Haidukewych
Nikolaos Kanakaris
Peter V. Giannoudis
Publikationsdatum
01.08.2011
Verlag
Springer-Verlag
Erschienen in
International Orthopaedics / Ausgabe 8/2011
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-010-1153-y

Weitere Artikel der Ausgabe 8/2011

International Orthopaedics 8/2011 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

TEP mit Roboterhilfe führt nicht zu größerer Zufriedenheit

15.05.2024 Knie-TEP Nachrichten

Der Einsatz von Operationsrobotern für den Einbau von Totalendoprothesen des Kniegelenks hat die Präzision der Eingriffe erhöht. Für die postoperative Zufriedenheit der Patienten scheint das aber unerheblich zu sein, wie eine Studie zeigt.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.