Technique for intraoperative determination of femoral rotation with a lateral femur nail (LFN, Synthes, Oberdorf, Switzerland)

verfasst von: Dominik Hoigné, Robert Hauck, Reto Babst

Erschienen in: Archives of Orthopaedic and Trauma Surgery | Ausgabe 12/2011

Einloggen, um Zugang zu erhalten

Abstract

Endomedullary femur nails with a head–neck implant offer an up to now unused point of reference for the determination of rotation during osteosynthesis. The lateral femur nail (LFN) or the long Proximal Femur Nail (long PFNA), for example, have recon screws or a blade placed at a 10° angle to the distal locking screw in the transversal plane. If the head–neck implant is inserted properly, the rotation of the femur can be measured with the C-arm taking the hole of the distal locking screw and the posterior condylar tangential line as reference lines. If the posterior condylar tangential line is parallel to the axes of the hole of the distal locking screw, then the rotation or anteversion of the femur is equal to the angle between the head–neck implant and the distal locking screw which is 10° with LFN or long PFNA. Differing rotation angles can be made visible by rotating the C-arm from the axial projection of the distal locking screw up to the posterior condylar tangential line. Three exemplary cases are presented. The recommended method was effective. The rotation of the femur can be measured intraoperatively with this technique and many revisions can be avoided.
Literatur
1.
Zurück zum Zitat Braten M, Terjesen T, Rossvoll I (1993) Torsional deformity after intramedullary nailing of femoral shaft fractures. Measurement of anteversion angles in 110 patients. J Bone Jt Surg 75:799–803 Braten M, Terjesen T, Rossvoll I (1993) Torsional deformity after intramedullary nailing of femoral shaft fractures. Measurement of anteversion angles in 110 patients. J Bone Jt Surg 75:799–803
2.
Zurück zum Zitat Buddenbrock B, Wissing H, Mller RD, John V (1997) Radiological determination of femoral rotation deformity—computerized tomography, optimized measurement accuracy and exposure dosage. Zeitschrift für Orthopädie und ihre Grenzgebiete 135:9–16PubMedCrossRef Buddenbrock B, Wissing H, Mller RD, John V (1997) Radiological determination of femoral rotation deformity—computerized tomography, optimized measurement accuracy and exposure dosage. Zeitschrift für Orthopädie und ihre Grenzgebiete 135:9–16PubMedCrossRef
3.
Zurück zum Zitat Dunn DM (1952) Anteversion of the neck of the femur; a method of measurement. J Bone Jt Surg B 34:181–186 Dunn DM (1952) Anteversion of the neck of the femur; a method of measurement. J Bone Jt Surg B 34:181–186
4.
Zurück zum Zitat Jaarsma RL, Pakvis DFM, Verdonschot N, Biert J, van Kampen A (2004) A rotational malalignment after intramedullary nailing of femoral fractures. J Orthop Trauma 18:403–409PubMedCrossRef Jaarsma RL, Pakvis DFM, Verdonschot N, Biert J, van Kampen A (2004) A rotational malalignment after intramedullary nailing of femoral fractures. J Orthop Trauma 18:403–409PubMedCrossRef
5.
Zurück zum Zitat Jend HH (1986) Computed tomographic determination of the anteversion angle. Premises and possibilities. RöFo 144:447–452PubMed Jend HH (1986) Computed tomographic determination of the anteversion angle. Premises and possibilities. RöFo 144:447–452PubMed
6.
Zurück zum Zitat Jerosch J, Finken N, Filler T, Peuker E, Rahgozar M, Lahmer A, Witzel U (1999) Robotics-assisted implantation of femoral components in hip endoprosthetics-an experimental study. Zeitschrift für Orthopädie und ihre Grenzgebiete 137:Oa7–O12PubMed Jerosch J, Finken N, Filler T, Peuker E, Rahgozar M, Lahmer A, Witzel U (1999) Robotics-assisted implantation of femoral components in hip endoprosthetics-an experimental study. Zeitschrift für Orthopädie und ihre Grenzgebiete 137:Oa7–O12PubMed
7.
Zurück zum Zitat Jiang X, Li X, Wang M, Gu X, Zhang B, Sun L, Zhang L, Liu Y, Liu D, Rong G (2002) Measurement of fracture malrotation after interlocking intramedullary nailing of femoral shaft fracture. zhong hua wai ke za zhi 40:55–58 Jiang X, Li X, Wang M, Gu X, Zhang B, Sun L, Zhang L, Liu Y, Liu D, Rong G (2002) Measurement of fracture malrotation after interlocking intramedullary nailing of femoral shaft fracture. zhong hua wai ke za zhi 40:55–58
8.
Zurück zum Zitat Kingsley PC, Olmsted KL (1948) A study to determine the angle of anteversion of the neck of the femur. J Bone Jt Surg A 30:745–751 Kingsley PC, Olmsted KL (1948) A study to determine the angle of anteversion of the neck of the femur. J Bone Jt Surg A 30:745–751
9.
Zurück zum Zitat Krettek C, Gler S, Schandelmaier P, Tscherne H (1996) Intramedullary nailing of open fractures. Der Orthopäde 25:223–233PubMed Krettek C, Gler S, Schandelmaier P, Tscherne H (1996) Intramedullary nailing of open fractures. Der Orthopäde 25:223–233PubMed
10.
Zurück zum Zitat Starker M, Hanusek S, Rittmeister M, Thoma W (1998) Validation of computerized tomography antetorsion angle measurement of the femur. Zeitschrift für Orthopädie und ihre Grenzgebiete 136(5):420–427PubMedCrossRef Starker M, Hanusek S, Rittmeister M, Thoma W (1998) Validation of computerized tomography antetorsion angle measurement of the femur. Zeitschrift für Orthopädie und ihre Grenzgebiete 136(5):420–427PubMedCrossRef
11.
Zurück zum Zitat Strecker W, Suger G, Kinzl L (1996) Local complications of intramedullary nailing. Der Orthopäde 25:274–291PubMed Strecker W, Suger G, Kinzl L (1996) Local complications of intramedullary nailing. Der Orthopäde 25:274–291PubMed
12.
Zurück zum Zitat Sugano N, Noble PC, Kamaric E (1998) A comparison of alternative methods of measuring femoral anteversion. J Comput Assist Tomogr 22(4):610–614PubMedCrossRef Sugano N, Noble PC, Kamaric E (1998) A comparison of alternative methods of measuring femoral anteversion. J Comput Assist Tomogr 22(4):610–614PubMedCrossRef
13.
Zurück zum Zitat Tönnis D, Heinecke A (1999) Acetabular and femoral anteversion: relationship with osteoarthritis of the hip. J Bone Jt Surg 81:1747–1770 Tönnis D, Heinecke A (1999) Acetabular and femoral anteversion: relationship with osteoarthritis of the hip. J Bone Jt Surg 81:1747–1770
14.
Zurück zum Zitat Winquist RA, Hansen ST, Clawson DK (1984) Closed intramedullary nailing of femoral fractures. A report of five hundred and twenty cases. J Bone Jt Surg 66:529–539 Winquist RA, Hansen ST, Clawson DK (1984) Closed intramedullary nailing of femoral fractures. A report of five hundred and twenty cases. J Bone Jt Surg 66:529–539
Metadaten
Titel
Technique for intraoperative determination of femoral rotation with a lateral femur nail (LFN, Synthes, Oberdorf, Switzerland)
verfasst von
Dominik Hoigné
Robert Hauck
Reto Babst
Publikationsdatum
01.12.2011
Verlag
Springer-Verlag
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 12/2011
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-011-1361-y

Weitere Artikel der Ausgabe 12/2011

Archives of Orthopaedic and Trauma Surgery 12/2011 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

TEP mit Roboterhilfe führt nicht zu größerer Zufriedenheit

15.05.2024 Knie-TEP Nachrichten

Der Einsatz von Operationsrobotern für den Einbau von Totalendoprothesen des Kniegelenks hat die Präzision der Eingriffe erhöht. Für die postoperative Zufriedenheit der Patienten scheint das aber unerheblich zu sein, wie eine Studie zeigt.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.