Objectives

The reproducibility of electronic color-measuring devices used in dentistry refers to the consistency of measurements of a single device and also that between identical devices. This in vitro study evaluated the short-term interdevice agreement of eight equivalent dental measurement devices.

Methods

The short-term repeatability of eight identical VITA Easyshade Advance color measurement devices was evaluated. Each device was used to quantify the Commission Internationale de l’Eclairage (CIE) L*a*b* color coordinates of ceramic disks, designed in accordance with guidelines set by the VITA Toothguide 3D-Master shade tab organization. Statistical analysis involved calculating the intraclass correlation coefficients (ICCs) and color differences (ΔE*) for corresponding measurements taken by the devices. In addition, the mean color difference from the mean (MCDM) was calculated for each color.

Results

All devices showed high ICCs for the color coordinates (L = 0.996, a = 0.993, b = 0.999). The ΔE* by shade ranged from 0.62 to 1.67. The MCDM by color-measuring device ranged from 0.11 to 0.23.

Conclusion

This in vitro study showed that the color-measuring devices used were suitable for determining shade with high repeatability.

Clinical relevance

The high interdevice agreement of the VITA Easyshade Advance means that dental professionals can use this device independently, without compromising the consistency and quality of color measurements.
Literatur
4.
Zurück zum Zitat Sproull RC (2001) Color matching in dentistry. Part I. The three-dimensional nature of color. 1973. J Prosthet Dent 86(5):453–457CrossRefPubMed Sproull RC (2001) Color matching in dentistry. Part I. The three-dimensional nature of color. 1973. J Prosthet Dent 86(5):453–457CrossRefPubMed
5.
Zurück zum Zitat Sproull RC (2001) Color matching in dentistry. Part II. Practical applications of the organization of color. 1973. J Prosthet Dent 86(5):458–464CrossRefPubMed Sproull RC (2001) Color matching in dentistry. Part II. Practical applications of the organization of color. 1973. J Prosthet Dent 86(5):458–464CrossRefPubMed
6.
Zurück zum Zitat Sproull RC (1974) Color matching in dentistry. 3. Color control. J Prosthet Dent 31(2):146–154CrossRefPubMed Sproull RC (1974) Color matching in dentistry. 3. Color control. J Prosthet Dent 31(2):146–154CrossRefPubMed
7.
Zurück zum Zitat Della Bona A, Barrett AA, Rosa V, Pinzetta C (2009) Visual and instrumental agreement in dental shade selection: three distinct observer populations and shade matching protocols. Dent Mater: Off Publ Acad Dent Mater 25(2):276–281. doi:10.1016/j.dental.2008.09.006 CrossRef Della Bona A, Barrett AA, Rosa V, Pinzetta C (2009) Visual and instrumental agreement in dental shade selection: three distinct observer populations and shade matching protocols. Dent Mater: Off Publ Acad Dent Mater 25(2):276–281. doi:10.​1016/​j.​dental.​2008.​09.​006 CrossRef
9.
Zurück zum Zitat Bhat V, Prasad DK, Sood S, Bhat A (2011) Role of colors in prosthodontics: application of color science in restorative dentistry. Ind J Dent Res: Off Publ Ind Soc Dent Res 22(6):804–809. doi:10.4103/0970-9290.94675 CrossRef Bhat V, Prasad DK, Sood S, Bhat A (2011) Role of colors in prosthodontics: application of color science in restorative dentistry. Ind J Dent Res: Off Publ Ind Soc Dent Res 22(6):804–809. doi:10.​4103/​0970-9290.​94675 CrossRef
11.
Zurück zum Zitat Llena C, Lozano E, Amengual J, Forner L (2011) Reliability of two color selection devices in matching and measuring tooth color. J Contemp Dent Pract 12(1):19–23CrossRefPubMed Llena C, Lozano E, Amengual J, Forner L (2011) Reliability of two color selection devices in matching and measuring tooth color. J Contemp Dent Pract 12(1):19–23CrossRefPubMed
13.
Zurück zum Zitat Finch K, Jarad FD, Adeyemi AA, Al-Shamaa S (2011) An audit of shade reproduction of fixed metal ceramic prostheses. Eur J Prosthodont Restor Dent 19(3):94–98PubMed Finch K, Jarad FD, Adeyemi AA, Al-Shamaa S (2011) An audit of shade reproduction of fixed metal ceramic prostheses. Eur J Prosthodont Restor Dent 19(3):94–98PubMed
16.
Zurück zum Zitat Ishikawa-Nagai S, Yoshida A, Da Silva JD, Miller L (2010) Spectrophotometric analysis of tooth color reproduction on anterior all-ceramic crowns: part 1: analysis and interpretation of tooth color. J Esthet Restor Dent: Off Publ Am Acad Esthet Dent 22(1):42–52. doi:10.1111/j.1708-8240.2009.00311.x CrossRef Ishikawa-Nagai S, Yoshida A, Da Silva JD, Miller L (2010) Spectrophotometric analysis of tooth color reproduction on anterior all-ceramic crowns: part 1: analysis and interpretation of tooth color. J Esthet Restor Dent: Off Publ Am Acad Esthet Dent 22(1):42–52. doi:10.​1111/​j.​1708-8240.​2009.​00311.​x CrossRef
18.
Zurück zum Zitat Paravina RD (2002) Evaluation of a newly developed visual shade-matching apparatus. Int J Prosthodontics 15(6):528–534 Paravina RD (2002) Evaluation of a newly developed visual shade-matching apparatus. Int J Prosthodontics 15(6):528–534
19.
Zurück zum Zitat Billmeyer FW Jr, Webber AC (1953) Three-dimensional color models constructed on the CIE and Munsell systems. J Opt Soc Am 43(2):69–70CrossRefPubMed Billmeyer FW Jr, Webber AC (1953) Three-dimensional color models constructed on the CIE and Munsell systems. J Opt Soc Am 43(2):69–70CrossRefPubMed
21.
Zurück zum Zitat Billmeyer FW, Jr., Campbell ED, Marcus RT (1975) Comparative performance of color-measuring instruments: second report; authors’ reply to comments. Applied optics 14 (2). doi:10.1364/AO.14.0265_1 Billmeyer FW, Jr., Campbell ED, Marcus RT (1975) Comparative performance of color-measuring instruments: second report; authors’ reply to comments. Applied optics 14 (2). doi:10.​1364/​AO.​14.​0265_​1
23.
Zurück zum Zitat Vichi A, Fazi G, Carrabba M, Corciolani G, Louca C, Ferrari M (2012) Spectrophotometric evaluation of color match of three different porcelain systems for all-ceramic zirconia-based restorations. Am J Dent 25(4):191–194PubMed Vichi A, Fazi G, Carrabba M, Corciolani G, Louca C, Ferrari M (2012) Spectrophotometric evaluation of color match of three different porcelain systems for all-ceramic zirconia-based restorations. Am J Dent 25(4):191–194PubMed
24.
Zurück zum Zitat Yoshida A, Miller L, Da Silva JD, Ishikawa-Nagai S (2010) Spectrophotometric analysis of tooth color reproduction on anterior all-ceramic crowns: part 2: color reproduction and its transfer from in vitro to in vivo. J Esthetic Restor Dent: Off Publ Am Acad Esthetic Dent 22(1):53–63. doi:10.1111/j.1708-8240.2009.00312.x CrossRef Yoshida A, Miller L, Da Silva JD, Ishikawa-Nagai S (2010) Spectrophotometric analysis of tooth color reproduction on anterior all-ceramic crowns: part 2: color reproduction and its transfer from in vitro to in vivo. J Esthetic Restor Dent: Off Publ Am Acad Esthetic Dent 22(1):53–63. doi:10.​1111/​j.​1708-8240.​2009.​00312.​x CrossRef
25.
Zurück zum Zitat Chen L, Tan JG, Zhou JF, Yang X, Du Y, Wang FP (2010) Reliability and accuracy of Crystaleye spectrophotometric system. Chin J Dental Res: Off J Sci Sec Chin Stomatol Assoc 13(2):139–145 Chen L, Tan JG, Zhou JF, Yang X, Du Y, Wang FP (2010) Reliability and accuracy of Crystaleye spectrophotometric system. Chin J Dental Res: Off J Sci Sec Chin Stomatol Assoc 13(2):139–145
26.
Zurück zum Zitat Johnston WM, Kao EC (1989) Assessment of appearance match by visual observation and clinical colorimetry. J Dent Res 68(5):819–822CrossRefPubMed Johnston WM, Kao EC (1989) Assessment of appearance match by visual observation and clinical colorimetry. J Dent Res 68(5):819–822CrossRefPubMed
27.
Zurück zum Zitat Berns RS. Billmeyer and Saltzman’s principles of color technology: John Wiley & Sons, INC.; 2000, 95-102 Berns RS. Billmeyer and Saltzman’s principles of color technology: John Wiley & Sons, INC.; 2000, 95-102
30.
Zurück zum Zitat Corcodel N, Zenthofer A, Setz J, Rammelsberg P, Hassel AJ (2011) Estimating costs for shade matching and shade corrections of fixed partial dentures for dental technicians in Germany: a pilot investigation. Acta Odontol Scand 69(5):319–320. doi:10.3109/00016357.2011.568964 CrossRefPubMed Corcodel N, Zenthofer A, Setz J, Rammelsberg P, Hassel AJ (2011) Estimating costs for shade matching and shade corrections of fixed partial dentures for dental technicians in Germany: a pilot investigation. Acta Odontol Scand 69(5):319–320. doi:10.​3109/​00016357.​2011.​568964 CrossRefPubMed
34.
Zurück zum Zitat Lehmann KM, Devigus A, Igiel C, Weyhrauch M, Schmidtmann I, Wentaschek S, Scheller H (2012) Are dental color measuring devices CIE compliant? Eur J Esthetic Dent: Off J Eur Acad Esthetic Dent 7(3):324–333 Lehmann KM, Devigus A, Igiel C, Weyhrauch M, Schmidtmann I, Wentaschek S, Scheller H (2012) Are dental color measuring devices CIE compliant? Eur J Esthetic Dent: Off J Eur Acad Esthetic Dent 7(3):324–333
36.
Zurück zum Zitat Douglas RD (1997) Precision of in vivo colorimetric assessments of teeth. J Prosthet Dent 77(5):464–470CrossRefPubMed Douglas RD (1997) Precision of in vivo colorimetric assessments of teeth. J Prosthet Dent 77(5):464–470CrossRefPubMed
37.
Zurück zum Zitat Lagouvardos PE, Fougia AG, Diamantopoulou SA, Polyzois GL (2009) Repeatability and interdevice reliability of two portable color selection devices in matching and measuring tooth color. J Prosthet Dent 101(1):40–45. doi:10.1016/S0022-3913(08)60289-9 CrossRefPubMed Lagouvardos PE, Fougia AG, Diamantopoulou SA, Polyzois GL (2009) Repeatability and interdevice reliability of two portable color selection devices in matching and measuring tooth color. J Prosthet Dent 101(1):40–45. doi:10.​1016/​S0022-3913(08)60289-9 CrossRefPubMed
Metadaten
Titel
Interdevice agreement of eight equivalent dental color measurement devices
verfasst von
M. Weyhrauch
C. Igiel
A. M. Pabst
S. Wentaschek
H. Scheller
K. M. Lehmann
Publikationsdatum
01.12.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
Clinical Oral Investigations / Ausgabe 9/2015
Print ISSN: 1432-6981
Elektronische ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-015-1456-x

Weitere Artikel der Ausgabe 9/2015

Clinical Oral Investigations 9/2015 Zur Ausgabe

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Update Zahnmedizin

Bestellen Sie unseren kostenlosen Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.