Skip to main content
Erschienen in: Journal of Orthopaedics and Traumatology 1/2013

Open Access 01.03.2013 | Original Article

Lumbar spine MRI in upright position for diagnosing acute and chronic low back pain: statistical analysis of morphological changes

verfasst von: Umberto Tarantino, Ezio Fanucci, Riccardo Iundusi, Monica Celi, Simone Altobelli, Elena Gasbarra, Giovanni Simonetti, Guglielmo Manenti

Erschienen in: Journal of Orthopaedics and Traumatology | Ausgabe 1/2013

download
DOWNLOAD
print
DRUCKEN
insite
SUCHEN

Abstract

Background

Patients with low back pain frequently demonstrate recumbent magnetic resonance imaging (MRI) alterations not always related to homogeneous clinical symptoms. The purpose of this study was to evaluate and quantify the statistical significance of variations of some anatomical parameters of the lumbosacral spine and reveal occult disc pathologies from recumbent to upright position in patients with acute and chronic low back pain.

Materials and methods

Fifty-seven patients complaining of low back pain (27 women, 30 men) underwent dynamic lumbosacral MRI with a 0.25-T tilting system (G-scan Esaote). We settled five parameters for which variations have been evaluated: lumbosacral angle, lordosis angle, L3–L4 intersomatic disc height, L3–L4 interspinous processes distance, and widest anteroposterior dural sac diameter. Images were obtained in both recumbent and upright positions.

Results

Statistically significant differences [one-way analysis of variance (ANOVA), p = 0.0043] were found between each pair of values of parameters sampled in recumbent and upright positions. In 70 % of patients, on visual qualitative analysis only, an increment of disc protrusions and/or spondylolisthesis was found in the upright position; in three cases, in the upright position only, an interarticular pseudocyst was found.

Conclusions

Dynamic MRI with an open-configuration, low-field tilting MRI system is a feasible and promising tool to study degenerative pathology of the spine. Moreover, in cases of low back pain with negative MRI in the recumbent position or in patients with pain in the upright position only, tilting MRI permits visualization of occult spine and disc pathologies in patients with acute or chronic low back pain.

Introduction

The lumbosacral spine is a complex biomechanical system that can adapt to various stresses to which it is subjected: the physiological load and various mechanical stresses produced by posture, daily activities, and traumatic events can accelerate its aging process. Degenerative disease of the lumbosacral spine is therefore one of the most common causes of disability. In this instance, degenerative disease is actually a generic term encompassing a wide range of different disease processes ranging from herniated discs to the pathology of yellow ligaments [1, 2]. Low back pain is an extremely frequent disease that most people experience at some point in their lives; estimates of the 1-year incidence of a first-ever episode of low back pain range between 6.3 % and 15.4 %, whereas estimates of the 1-year incidence of any episode of low back pain range between 1.5 % and 36 % [3]. The imaging techniques using traditional magnetic resonance imaging (MRI) have the major limitation of studying the spine in a position of relative functional rest, as images are acquired with the patient in the supine position while the pain exacerbates in the upright position. False negatives in MRI of the spine performed in the supine position are often due to patient position, with knees and hips bent and spinal variation with increasing breadth of the foramen and vertebral canal. Pathological conditions underlying clinical symptoms, often prompted by standing or sitting, are therefore not seen [4, 5]. This can result in negative findings, even in the presence of symptoms, or an underestimation of pathological specimens. Regardless, the final result is distorted.
Until a few years ago, X-ray was the only practicable imaging modality for the spine in the upright position. This examination is valid and useful for evaluating spinal curvatures, but it shows its limitations when the assessment should be directed to disc structures or when it is necessary to obtain measurements free from problems due to overlapping of anatomical images. A first attempt to evaluate the spine under the loading condition was done with the axial load technique, which is to simulate physiological loading of the spine in the orthostatic position. Although results were certainly interesting, the technique has not achieved a general consensus. Studies with axial load, even if they allow better assessment in relation to the higher signal-to-noise ratio (SNR) afforded by the high-field equipment, do not allow evaluation of the influence that physiological load—represented by the weight of the head and body and by muscle activation—has on the lumbar spine, simulating a load with caudate–cranial direction [68].
The technological advancement of open equipment with low- and medium-intensity magnetic field, greater gradient homogeneity, and faster sequences resulted in a significant improvement in SNR in spatial and contrast resolution and therefore image quality. Some MRI equipment is capable of obtaining images of the spine in orthostatic position, which should better evidence pathological conditions that are sometimes “invisible” in the supine position. These devices, all characterized by being open, also have the advantage of eliminating the patient’s feeling of claustrophobia, which sometimes limits diagnostic evaluation of the spine [912].
Some publications In the literature involve studying the lumbar spine using MRI equipment with the patient in the upright position, many with medium resistive magnetic field (0.6 T); often, however, observation of physiological and pathological changes detected is not accompanied by a full statistical analysis, which in a certain way, verify the findings observed [1316]. The purpose of this paper is to provide a statistical evaluation of the variations observed in physiological and pathological parameters of the lumbosacral spine in patients with acute and chronic low back pain studied with new low-field MRI equipment in supine and upright positions.

Materials and methods

Inclusion criterion was lumbar back pain experienced in standing position. Exclusion criteria were previous spine surgery at any level and/or referred inability to maintain standing position for the scheduled examination time. Fifty-seven patients [27 women (47 %) and 30 men (53 %); mean age 48 (±15) years (women 51 years, men 46 years)], each with a history of low back pain, were studied. Based on the time of painful symptom onset, patients were divided into two groups: acute (within 90 days) and chronic (>90 days) of onset. Among women, ten of 27 (37 %) showed acute onset and 17 of 27 (63 %) chronic onset; among men 11 of 30 (37 %) had acute pain and 19 of 30 (63 %) chronic pain. Fifty percent of patients reported symptoms in the supine position, whereas they all reported pain in the standing position: 34 patients (60 %) had never undergone any diagnostic procedure or had a negative MRI in the supine position; 23 (40 %) had a positive diagnosis for spinal disorder with other diagnostic tools (X-rays, MRI, CT). All patients underwent lumbosacral spine MRI in supine and upright positions, and all gave informed consent prior to being included in the study; local ethics committee authorization was not required because of the standard of care. This investigation was performed in accordance with the ethical standards of the 1964 Declaration of Helsinky as revised in 2000.
The machine used is a permanent magnet of 0.25 T (Esaote G-SCAN), which allows spinal imaging in both supine and upright positions using a tilting system that can rotate from 0° to 90° without the need for patient repositioning. The study was carried out at a table angle of 82° in the upright position, as described in the literature [1], biomechanically reproducing an orthostatic position without incurring patient stability problems, as can be verified by tilting the table to a 90° angle.
With the patient in the supine decubitus, survey sequences were acquired. Sequences were as follows: fast spin echo (FSE) sagittal T2-weighted (TR 3,460 ms, TE 120 ms, 224 × 208 matrix, FOV 320 × 320 mm, mean of three samples; 12.slices 4-mm thick with 0.5-mm gap, acquisition time 5 min 39 s); SE sagittal T1-weighted (TR 580 ms, TE 22 ms, matrix 224 × 208, FOV 300 × 300 mm, mean of two samples; 12 slices 4 mm thick with 0.5 mm gap, acquisition time 4 min 54 s); FSE T2-weighted in the oblique axial plane over intersomatic spaces L3–L4, L4–L5, and L5–S1 (TR 3,880 ms, TE 120 ms, 192 × 192 matrix, FOV 260 × 260 mm, average over three samples, 12 slices 4-mm thick with 0.5-mm gap, acquisition time 6 min 20s ). Then the complex subject-magnet was rotated vertically to 82°. Sequences obtained in this configuration are as follows: sagittal FSE T2-weighted (TR 3,460 ms, TE 120 ms, 240 × 240 matrix, FOV 320 × 320 mm, mean of three samples, 12 slices 4.0-mm thick, 0.5-mm gap, acquisition time 5 min 39 s); FSE T2-weighted in the oblique axial plane over intersomatic spaces L3–L4, L4–L5, and L5–S1 (TR 3,880 ms, TE 120 ms, matrix 192 × 192, FOV 260 × 260 mm, mean of three samples, 12 slices 4-mm thick with 0.5 mm gap, acquisition time 6 min 20 s). It was not possible to follow the same order of sequence acquisitions for all patients. In cases of severe low back pain, we preferred to acquire the first sequences in the upright position to minimize any motion artefacts related to the position, and followed by the supine position, which itself is a less challenging position for these patients.

Image analysis

To evaluate and quantify anatomical and pathological changes identified in the study performed in both supine and standing positions, the following parameters were taken into account:
1.
Lumbosacral angle: This was defined as the anterior open-angle intercepted by two tangent lines of the anterior walls of L5 and S1 (Fig. 1a, b). The normal range for this angle is 120–180°. An increased angle corresponds to vertical tilting of the sacrum, which biomechanically produces an increased load on the anterior column and accelerates the degenerative processes of the L5–S1 disc. On the contrary, a decreased lumbosacral angle is associated with sacrum horizontalization, which consequently creates an amplified load on the posterior elements (facet joints).
 
2.
Lordosis angle: This was defined as the superior open-angle intercepted between the two perpendicular lines to the tangent of the superior endplate of L1 and the inferior endplate of L5 (Fig. 1a, b). This angle has a normal value of about 50°.
 
3.
Disc height: This is measured at the point of maximum distance between the inferior and superior endplates of L3 and L4, respectively (Fig. 2a, b).
 
4.
Interspinous distance between L3 and L4 (Fig. 3a, b).
 
5.
Maximum anteroposterior diameter of the dural sac (Fig. 3a, b).
 
Morphovolumetric differences in disc protrusions, herniations, and spondylolisthesis with the patient in the supine and standing positions have not been quantified in terms of statistical variations in this paper; they are the focus of a further investigations.

Statistical analysis

Data collected from measurements taken in supine and standing positions are reported as mean and relative standard deviation (SD); therefore, comparison tests were performed with parametric statistics [t test, one-way analysis of variance (ANOVA)]. In this analysis ANOVA is the most useful test because it allows evaluation of the effect due to gender (male–female) with normalized age variables.

Results

The study was performed on 53 of the 57 patients recruited; four individuals presented with acute symptoms, and study in upright position was saddled with motion artifacts. For the measured parameters, detected findings are described below:
Under physiological conditions, in the transition from supine to upright position, there was a decrease in the lumbosacral angle and an increase of lordosis angle. In supine position, lumbosacral angle had a mean value of 136.7° (women 137.4° ± 8.3°; men 136.0° ± 8.8°) and in standing position 131.7° (women 132.4° ± 8.6°; men 131.1° ± 9.1°) (ANOVA, p = 0.00089); No statistically significant difference between sexes were found (Figs. 1a, b, 4a).
In the supine position, lordosis angle had a mean value of 35.5° (women 35.4° ± 11.8°; men 35.5° ± 10°) and in upright position 41.6° (women 41.8° ± 12.3°; men 41.5° ± 9.1°) (ANOVA, p = 0.00097). No statistically significant difference between sexes was found (Figs. 1a, b, 4b). As previously described, intervertebral disc thickness was reduced from supine to standing position, with a mean of 12.9 mm (women 11.7 ± 2 mm; men 14.0 ± 1.8 mm) and 11.2 (women 10.0 ± 2.3 mm; men 12.1 ± 1.6 mm), respectively (ANOVA, p = 0.000083). There was a statistically significant difference between sexes (Figs. 2a, b, 5).
The distance between the spinous processes at L3–L4 presented significant differences: mean 14.6 mm (women 13.8 ± 3.5 mm; men 15.2 ± 2.9 mm) and 12.8 mm (women 12.2 ± 3.7 mm; men 13.5 ± 3.3 mm), respectively, in supine and standing positions (ANOVA, p = 0.0073). There was a significant difference between sexes in interspinous distance, with men greater than women (ANOVA, p = 0.0039) (Figs. 3a, b, 6).
Anteroposterior diameter of the dural sac in supine position was a mean of 13.1 mm (women 13.0 ± 1.3 mm; men 13.2 ± 1.9 mm) and 14.5 mm in upright position (women 14.3 ± 1.5 mm; men 14.7 ± 2.3 mm) (ANOVA, p = 0.00068), without significant differences between sexes (Figs. 3a, b, 7).
Pathological changes were found in all patients. The most common findings were disc protrusions (44), disc herniations (12), facet-joint pathologies (10), spondylolisthesis (4), spinal canal stenosis (1), and pseudocysts of the joint capsules (3). Upright MRI showed a significant volumetric increase of disc protrusions than standard MRI. Moreover, upright MRI demonstrated disc protrusions in 11 patients with negative findings in supine position (Fig. 8a, b). In one case, a pseudocyst of the facet joint leading to a compressive effect on the nerve root was found in the standing position only (Fig. 9a–d).
Four cases of spondylolisthesis, observed in supine position, illustrated aggravation in upright position during the same study (Fig. 10a, b).

Discussion

The evaluations of physiological and biomechanical elements showed that for each considered parameter, there are significant and meaningful differences depending on supine or upright position and sometimes even on gender; careful analysis of an MRI should therefore be performed according to these data when interpreting subsequent pathological findings. Reduced lumbosacral and increased lordosis angle depend on activation of postural effects of body weight mediated by abdominal and paraspinal muscles. In standing position, the lumbosacral angle decreases in relation to verticality of the spine, which is necessary to support the increase in weight, whereas the increase in lordosis angle reflects compensation by muscle contracture. The reduction of intervertebral disc height was highly significant (p = 0.000083), undoubtedly due to body weight and muscle activation [11, 14, 17]. In particular, the reduction of disc height affects the posterior portion, whereas anteriorly, there was a slight increase, with major changes at L2–L3 and L3–L4 [18].
Observed variations in the lordosis and lumbosacral angle values confirm the already known physiological changes produced by the transition from supine to orthostatic position. From a biomechanical point of view, reduced intervertebral disc thickness is closely related: the disk is the fulcrum of a lever in which the resistance is represented by facet joints, and muscles are the power. These aspects emphasize the high sensitivity of the method in evaluating changes in physiopathological discs. These aspects confirms the high sensitivity in assessing the lumbar spine under load conditions, thereby putting some stress on the importance of upright MRI in all those cases where the supine MRI assessment is negative.
Another parameter with a high statistical significance with regard to variations was the anteroposterior diameter of the dural sac. This aspect was previously assessed [11, 19], but in terms of spinal canal area and a reduction of 5.2 % of the dural sac, which was evident in the transition from the supine to the upright position, relating to two variables: change in position of disc and yellow ligaments. These factors undoubtedly influenced canal measurements. Width reduction of the canal was also closely related to the possible redundancy, in the upright position, of the meninges and yellow ligaments acting as primary factors in the reduction of canal amplitude in normal patients [11, 20]. The measurement is of considerable importance in the presence of suspected stenosis not detectable in the supine position, with the necessary considerations resulting from the therapeutic point of view.
The last investigated parameter, interspinous distance, showed a significant change in the passage from supine to upright position in both acute and chronic patients with instability. In the supine position, we could only identify indirect radiological signs of instability (degenerative disc, facet joints, ligament disease) and a few misalignments [21]. MRI in the standing position can detect changes in intersegmental motion and correlate it with symptoms. Instability can be considered part of the physiological degeneration of the lumbar spine and is divided into three phases: Initially, there is a change in movement of the complex consisting of the disc, some adjacent ligaments, and facet joints; signs of degeneration are minimal [21]. At this stage, there is movement dysfunction that may still not be appreciated in the upright MRI. In the next stage, the so-called instability phase, signs of degeneration are more appreciable, resulting in hypermobility of some spinal segments in comparison with supine MRI. In this phase, the excessive movement can lead to a higher degree of stenosis of the foramen and recesses, which may correlate with increased symptomatology. The disc below the affected level can show signs of degeneration and increased movement [22]. Progression of the degenerative phase leads to the appearance of osteophytes, with resultant restabilization and reduction in movement (step 3); this phase of restabilization is difficult to interpret without the aid of a dynamic study of the spine [23, 24]. In the beginning, degenerative or isthmic spondylolisthesis may appear stable without significant change in angular rotation or horizontal translation. As the degree of degeneration increases, it can be increasingly appreciated [22].
Limitations of this study are mainly due to two factors: in the upright position, patients with acute low back pain may find it difficult to maintain the immobility necessary for the duration of the imaging acquisition with a duration of at least 4 min for each sequence. A second and equally important negative factor is the difficulty sometimes encountered in evaluating the most lateral areas of the spine, such as foramen and lateral recesses.
In conclusion, supine MRI remains the technique of choice for detecting degenerative disc disease associated with acute and chronic low back pain. However, in about one of three cases, conventional MRI performed in the supine position is unable to answer the clinical question [2]; in these cases, or if it is necessary to assess more accurately the degree of spinal instability, particularly if surgical therapy is scheduled, the upright MRI performed dedicated equipment can be a complementary investigation to traditional MRI survey.

Conflict of interest

None.

Open Access

This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 2.0 International License (https://​creativecommons.​org/​licenses/​by/​2.​0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Literatur
1.
Zurück zum Zitat Gallucci M, Limbucci N, Paonessa A, Splendiani A (2007) Degenerative disease of the spine. Neuroimaging Clin of N Am 17:87–103CrossRef Gallucci M, Limbucci N, Paonessa A, Splendiani A (2007) Degenerative disease of the spine. Neuroimaging Clin of N Am 17:87–103CrossRef
2.
Zurück zum Zitat Splendiani A, Di Fabio MV, Barile A, Masciocchi C (2008) Tecnica di studio RM del rachide lombare sotto carico. In: Leone A, Martino F (eds) Imaging del rachide. Il vecchio e il nuovo. Springer, Italy, pp 123–134CrossRef Splendiani A, Di Fabio MV, Barile A, Masciocchi C (2008) Tecnica di studio RM del rachide lombare sotto carico. In: Leone A, Martino F (eds) Imaging del rachide. Il vecchio e il nuovo. Springer, Italy, pp 123–134CrossRef
3.
Zurück zum Zitat Hoy D, Brooks P, Blyth F, Buchbinder R (2010) The epidemiology of low back pain. Best Pract Res Clin Rheumatol 24:769–781PubMedCrossRef Hoy D, Brooks P, Blyth F, Buchbinder R (2010) The epidemiology of low back pain. Best Pract Res Clin Rheumatol 24:769–781PubMedCrossRef
4.
Zurück zum Zitat Claus A, Hides J, Moseley GL, Hodges P (2008) Sitting versus standing: does the intradiscal pressure cause disc degeneration or low back pain? J Electromyogr Kinesiol 18:550–558PubMedCrossRef Claus A, Hides J, Moseley GL, Hodges P (2008) Sitting versus standing: does the intradiscal pressure cause disc degeneration or low back pain? J Electromyogr Kinesiol 18:550–558PubMedCrossRef
5.
Zurück zum Zitat Parent EC, Videman T, Battié MC (2006) The effect of lumbar flexion and extension on disc contour abnormality measured quantitatively on magnetic resonance imaging. Spine (Phila Pa 1976) 31:2836–2842CrossRef Parent EC, Videman T, Battié MC (2006) The effect of lumbar flexion and extension on disc contour abnormality measured quantitatively on magnetic resonance imaging. Spine (Phila Pa 1976) 31:2836–2842CrossRef
6.
Zurück zum Zitat Vitzthum HE, König A, Seifert V (2000) Dynamic examination of the lumbar spine by using vertical, open magnetic resonance imaging. J Neurosurg 93:58–64PubMed Vitzthum HE, König A, Seifert V (2000) Dynamic examination of the lumbar spine by using vertical, open magnetic resonance imaging. J Neurosurg 93:58–64PubMed
7.
Zurück zum Zitat Manenti G, Liccardo G, Sergiacomi G, Ferrante L, D’Andrea G, Konda D, Fraioli B, Schillaci O, Simonetti G, Masala S (2003) Axial loading MRI of the lumbar spine. In Vivo 17:413–420PubMed Manenti G, Liccardo G, Sergiacomi G, Ferrante L, D’Andrea G, Konda D, Fraioli B, Schillaci O, Simonetti G, Masala S (2003) Axial loading MRI of the lumbar spine. In Vivo 17:413–420PubMed
8.
Zurück zum Zitat Weishaupt D, Schmid MR, Zanetti M, Boos N, Romanowski B, Kissling RO, Dvorak J, Hodler J (2000) Positional MR imaging of the lumbar spine: does it demonstrate nerve root compromise not visible at conventional MR imaging? Radiology 215:247–253PubMedCrossRef Weishaupt D, Schmid MR, Zanetti M, Boos N, Romanowski B, Kissling RO, Dvorak J, Hodler J (2000) Positional MR imaging of the lumbar spine: does it demonstrate nerve root compromise not visible at conventional MR imaging? Radiology 215:247–253PubMedCrossRef
9.
Zurück zum Zitat Madsen R, Jensen TS, Pope M, Sørensen JS, Bendix T (2008) The effect of body position and axial load on spinal canal morphology: an MRI study of central spinal stenosis. Spine (Phila Pa 1976) 33:61–67CrossRef Madsen R, Jensen TS, Pope M, Sørensen JS, Bendix T (2008) The effect of body position and axial load on spinal canal morphology: an MRI study of central spinal stenosis. Spine (Phila Pa 1976) 33:61–67CrossRef
10.
Zurück zum Zitat Danielson B, Willén J (2001) Axially loaded magnetic resonance image of the lumbar spine in asymptomatic individuals. Spine (Phila Pa 1976) 26:2601–2606CrossRef Danielson B, Willén J (2001) Axially loaded magnetic resonance image of the lumbar spine in asymptomatic individuals. Spine (Phila Pa 1976) 26:2601–2606CrossRef
11.
Zurück zum Zitat Schmid MR, Stucki G, Duewell S, Wildermuth S, Romanowski B, Hodler J (1999) Changes in cross-sectional measurements of the spinal canal and intervertebral foramina as a function of body position: in vivo studies on an open-configuration MR system. Ajr Am J Roentgenol 172:1095–1102PubMedCrossRef Schmid MR, Stucki G, Duewell S, Wildermuth S, Romanowski B, Hodler J (1999) Changes in cross-sectional measurements of the spinal canal and intervertebral foramina as a function of body position: in vivo studies on an open-configuration MR system. Ajr Am J Roentgenol 172:1095–1102PubMedCrossRef
12.
Zurück zum Zitat Vitaz TW, Shields CB, Raque GH, Hushek SG, Moser R, Hoerter N, Moriarty TM (2004) Dynamic weight-bearing cervical magnetic resonance imaging: technical review and preliminary results. South Med J 97:456–461PubMedCrossRef Vitaz TW, Shields CB, Raque GH, Hushek SG, Moser R, Hoerter N, Moriarty TM (2004) Dynamic weight-bearing cervical magnetic resonance imaging: technical review and preliminary results. South Med J 97:456–461PubMedCrossRef
13.
Zurück zum Zitat Zamani AA, Moriarty T, Hsu L, Winalski CS, Schaffer JL, Isbister H, Schenck JF, Rohling KW, Jolesz F (1998) Functional MRI of the lumbar spine in erect position in a superconducting open-configuration MR system: preliminary results. J Magn Reson Imaging 8:1329–1333PubMedCrossRef Zamani AA, Moriarty T, Hsu L, Winalski CS, Schaffer JL, Isbister H, Schenck JF, Rohling KW, Jolesz F (1998) Functional MRI of the lumbar spine in erect position in a superconducting open-configuration MR system: preliminary results. J Magn Reson Imaging 8:1329–1333PubMedCrossRef
14.
Zurück zum Zitat Jinkins JR, Dworkin JS, Damadian RV (2005) Upright, weight-bearing, dynamic-kinetic MRI of the spine: initial results. Eur Radiol 15:1815–1825PubMedCrossRef Jinkins JR, Dworkin JS, Damadian RV (2005) Upright, weight-bearing, dynamic-kinetic MRI of the spine: initial results. Eur Radiol 15:1815–1825PubMedCrossRef
15.
Zurück zum Zitat Jinkins JR, Dworkin J (2003) Proceedings of the State-of-the-art symposium on diagnostic and interventional radiology of the spine, Antwerp, September 7, 2002 (Part two). Upright, weight-bearing, dynamic-kinetic MRI of the spine: pMRI/kMRI. JBR-BTR 86:286–293PubMed Jinkins JR, Dworkin J (2003) Proceedings of the State-of-the-art symposium on diagnostic and interventional radiology of the spine, Antwerp, September 7, 2002 (Part two). Upright, weight-bearing, dynamic-kinetic MRI of the spine: pMRI/kMRI. JBR-BTR 86:286–293PubMed
16.
Zurück zum Zitat Jinkins JR (2004) Acquired degenerative changes of the intervertebral segments at and suprajacent to the lumbosacral junction. A radioanatomic analysis of the nondiscal structures of the spinal column and perispinal soft tissues. Eur J Radiol 50:134–158PubMedCrossRef Jinkins JR (2004) Acquired degenerative changes of the intervertebral segments at and suprajacent to the lumbosacral junction. A radioanatomic analysis of the nondiscal structures of the spinal column and perispinal soft tissues. Eur J Radiol 50:134–158PubMedCrossRef
17.
Zurück zum Zitat Ferreiro Perez A, Garcia Isidro M, Ayerbe E, Castedo J, Jinkins JR (2007) Evaluation of intervertebral disc herniation and hypermobile intersegmental instability in symptomatic adult patients undergoing recumbent and upright MRI of the cervical or lumbosacral spines. Eur J Radiol 62:444–448PubMedCrossRef Ferreiro Perez A, Garcia Isidro M, Ayerbe E, Castedo J, Jinkins JR (2007) Evaluation of intervertebral disc herniation and hypermobile intersegmental instability in symptomatic adult patients undergoing recumbent and upright MRI of the cervical or lumbosacral spines. Eur J Radiol 62:444–448PubMedCrossRef
18.
Zurück zum Zitat Lee SU, Hargens AR, Fredericson M, Lang PK (2003) Lumbar spine disc heights and curvature: upright posture versus supine compression harness. Aviat Space Environ Med 74:512–516PubMed Lee SU, Hargens AR, Fredericson M, Lang PK (2003) Lumbar spine disc heights and curvature: upright posture versus supine compression harness. Aviat Space Environ Med 74:512–516PubMed
19.
Zurück zum Zitat Hirasawa Y, Bashir WA, Smith FW, Magnusson ML, Pope MH, Takahashi K (2007) Postural changes of the dural sac in the lumbar spines of asymptomatic individuals using positional stand-up magnetic resonance imaging. Spine (Phila Pa 1976) 32:36–40CrossRef Hirasawa Y, Bashir WA, Smith FW, Magnusson ML, Pope MH, Takahashi K (2007) Postural changes of the dural sac in the lumbar spines of asymptomatic individuals using positional stand-up magnetic resonance imaging. Spine (Phila Pa 1976) 32:36–40CrossRef
20.
Zurück zum Zitat Hiwatashi A, Danielson B, Moritani T, Bakos RS, Rodenhause TG, Pilcher WH, Westesson PL (2004) Axial loading during MR imaging can influence treatment decision for symptomatic spinal stenosis. AJNR Am J Neuroradiol 25:170–174PubMed Hiwatashi A, Danielson B, Moritani T, Bakos RS, Rodenhause TG, Pilcher WH, Westesson PL (2004) Axial loading during MR imaging can influence treatment decision for symptomatic spinal stenosis. AJNR Am J Neuroradiol 25:170–174PubMed
21.
Zurück zum Zitat Nizard RS, Wybier M, Laredo JD (2001) Radiologic assessment of lumbar intervertebral instability and degenerative spondylolisthesis. Radiol Clin North Am 39:55–71PubMedCrossRef Nizard RS, Wybier M, Laredo JD (2001) Radiologic assessment of lumbar intervertebral instability and degenerative spondylolisthesis. Radiol Clin North Am 39:55–71PubMedCrossRef
22.
Zurück zum Zitat Karadimas EJ, Siddiqui M, Smith FW, Wardlaw D (2006) Positional MRI changes in supine versus sitting postures in patients with degenerative lumbar spine. J Spinal Disord Tech 19:495–500PubMedCrossRef Karadimas EJ, Siddiqui M, Smith FW, Wardlaw D (2006) Positional MRI changes in supine versus sitting postures in patients with degenerative lumbar spine. J Spinal Disord Tech 19:495–500PubMedCrossRef
23.
Zurück zum Zitat Jayakumar P, Nnadi C, Saifuddin A, Macsweeney E, Casey A (2006) Dynamic degenerative lumbar spondylolisthesis: diagnosis with axial loaded magnetic resonance imaging. Spine (Phila Pa 1976) 31:E298–E301CrossRef Jayakumar P, Nnadi C, Saifuddin A, Macsweeney E, Casey A (2006) Dynamic degenerative lumbar spondylolisthesis: diagnosis with axial loaded magnetic resonance imaging. Spine (Phila Pa 1976) 31:E298–E301CrossRef
24.
Zurück zum Zitat Friberg O (1987) Lumbar instability: a dynamic approach by traction-compression radiography. Spine 12:119–129PubMedCrossRef Friberg O (1987) Lumbar instability: a dynamic approach by traction-compression radiography. Spine 12:119–129PubMedCrossRef
Metadaten
Titel
Lumbar spine MRI in upright position for diagnosing acute and chronic low back pain: statistical analysis of morphological changes
verfasst von
Umberto Tarantino
Ezio Fanucci
Riccardo Iundusi
Monica Celi
Simone Altobelli
Elena Gasbarra
Giovanni Simonetti
Guglielmo Manenti
Publikationsdatum
01.03.2013
Verlag
Springer International Publishing
Erschienen in
Journal of Orthopaedics and Traumatology / Ausgabe 1/2013
Print ISSN: 1590-9921
Elektronische ISSN: 1590-9999
DOI
https://doi.org/10.1007/s10195-012-0213-z

Weitere Artikel der Ausgabe 1/2013

Journal of Orthopaedics and Traumatology 1/2013 Zur Ausgabe

Acknowledgement to Referees

2012 Scientific Referees

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

TEP mit Roboterhilfe führt nicht zu größerer Zufriedenheit

15.05.2024 Knie-TEP Nachrichten

Der Einsatz von Operationsrobotern für den Einbau von Totalendoprothesen des Kniegelenks hat die Präzision der Eingriffe erhöht. Für die postoperative Zufriedenheit der Patienten scheint das aber unerheblich zu sein, wie eine Studie zeigt.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.