Erschienen in: International Journal of Computer Assisted Radiology and Surgery 6/2016

01.06.2016 | Original Article

Spectral analysis of the tremor motion for needle detection in curvilinear ultrasound via spatiotemporal linear sampling

verfasst von: Parmida Beigi, Robert Rohling, Septimiu E. Salcudean, Gary C. Ng

Erschienen in: International Journal of Computer Assisted Radiology and Surgery | Ausgabe 6/2016

Einloggen, um Zugang zu erhalten

Abstract

Purpose

This paper presents a new approach to detect a standard handheld needle in ultrasound-guided interventions.

Methods

Our proposal is to use natural hand tremor, which causes minute displacement of the needle, to detect the needle in ultrasound B-mode images. Subtle displacements arising from tremor motion have a periodic pattern which is usually imperceptible to the naked eye in the B-mode image. We use these displacement measurements in a spatiotemporal framework to detect linear structures with periodic pattern among a sequence of frames. The needle trajectory is estimated as a linear path in the image having maximum spectral correlation with the time trace of displacement due to tremor. A coarse estimation process is followed by a fine estimation step, where the motion pattern is analyzed along spatiotemporal linear paths with various angles originating from the estimated puncture site, within the trajectory channel. Spectral coherency is derived for each sample path versus the reference path, and the needle trajectory is identified as the mean of the sample paths with the maximum coherence within the tremor frequency range.

Results

To evaluate the detection accuracy, we tested the method in vivo on porcine tissue, where the needle was inserted into the biceps femoris muscle. To understand whether tremor itself affects needle position, the maximum angular change due to tremor was calculated: mean, standard deviation (SD) and root-mean-square (RMS) measurement of \(0.43^\circ , 0.23^\circ \) and \(0.48^\circ \). The accuracy of the needle trajectory was calculated by comparing to an expert manual segmentation, averaged over the captured data and presented in mean, SD and RMS error of \(2.83^\circ , 1.64^\circ \) and \(3.23^\circ \), respectively.

Conclusion

Results demonstrate that natural tremor motion creates minute coherent motion along the needle, which could be used to localize the needle trajectory within the acceptable accuracy. This method is suitable for standard needles used clinically.
Literatur
1.
Zurück zum Zitat Adebar TK, Fletcher AE, Okamura AM (2014) 3D ultrasound-guided robotic needle steering in biological tissue. IEEE Trans Biomed Eng 61(12):2899–2910CrossRefPubMed Adebar TK, Fletcher AE, Okamura AM (2014) 3D ultrasound-guided robotic needle steering in biological tissue. IEEE Trans Biomed Eng 61(12):2899–2910CrossRefPubMed
2.
Zurück zum Zitat Beigi P, Salcudean T, Rohling RN, Lessoway VA, Ng GC (2015) Needle detection in ultrasound using the spectral properties of the displacement field: a feasibility study. In: SPIE Medical Imaging Beigi P, Salcudean T, Rohling RN, Lessoway VA, Ng GC (2015) Needle detection in ultrasound using the spectral properties of the displacement field: a feasibility study. In: SPIE Medical Imaging
3.
Zurück zum Zitat Beigi P, Salcudean T, Rohling RN, Lessoway VA, Ng GC (2015) Needle trajectory and tip localization in 3D ultrasound using a moving stylus. Ultrasound Med Biol 41(7):2057–2070CrossRefPubMed Beigi P, Salcudean T, Rohling RN, Lessoway VA, Ng GC (2015) Needle trajectory and tip localization in 3D ultrasound using a moving stylus. Ultrasound Med Biol 41(7):2057–2070CrossRefPubMed
4.
Zurück zum Zitat Boctor EM, Choti MA, Burdette EC, Webster RJ (2008) Three-dimensional ultrasound-guided robotic needle placement: an experimental evaluation. Int J Med Robot Comput Assist Surg 4(2):180–91CrossRef Boctor EM, Choti MA, Burdette EC, Webster RJ (2008) Three-dimensional ultrasound-guided robotic needle placement: an experimental evaluation. Int J Med Robot Comput Assist Surg 4(2):180–91CrossRef
5.
Zurück zum Zitat Cheung S, Rohling R (2004) Enhancement of needle visibility in ultrasound-guided percutaneous procedures. Ultrasound Med Biol 30(5):617–624CrossRefPubMed Cheung S, Rohling R (2004) Enhancement of needle visibility in ultrasound-guided percutaneous procedures. Ultrasound Med Biol 30(5):617–624CrossRefPubMed
6.
Zurück zum Zitat Chin KJ, Perlas A, Chan VWS, Brull R (2008) Needle visualization in ultrasound-guided regional anesthesia: challenges and solutions. Reg Anesth Pain Med 33(6):532–544PubMed Chin KJ, Perlas A, Chan VWS, Brull R (2008) Needle visualization in ultrasound-guided regional anesthesia: challenges and solutions. Reg Anesth Pain Med 33(6):532–544PubMed
7.
Zurück zum Zitat Draper KJ, Blake CC, Gowman L, Downey DB, Fenster A (2000) An algorithm for automatic needle localization in ultrasound-guided breast biopsies. Med Phys 27(8):1971–1979CrossRefPubMed Draper KJ, Blake CC, Gowman L, Downey DB, Fenster A (2000) An algorithm for automatic needle localization in ultrasound-guided breast biopsies. Med Phys 27(8):1971–1979CrossRefPubMed
8.
Zurück zum Zitat Harmat A, Rohling RN, Salcudean SE (2006) Needle tip localization using stylet vibration. Ultrasound Med Biol 32(9):1339–1348CrossRefPubMed Harmat A, Rohling RN, Salcudean SE (2006) Needle tip localization using stylet vibration. Ultrasound Med Biol 32(9):1339–1348CrossRefPubMed
9.
Zurück zum Zitat Hatt CR, Ng G, Parthasarathy V (2015) Enhanced needle localization in ultrasound using beam steering and learning-based segmentation. Comput Med Imaging Graph 41:46–54 Hatt CR, Ng G, Parthasarathy V (2015) Enhanced needle localization in ultrasound using beam steering and learning-based segmentation. Comput Med Imaging Graph 41:46–54
10.
Zurück zum Zitat Hebard S, Hocking G (2011) Echogenic technology can improve needle visibility during ultrasound-guided regional anesthesia. Reg Anesth Pain Med 36(2):185–189CrossRefPubMed Hebard S, Hocking G (2011) Echogenic technology can improve needle visibility during ultrasound-guided regional anesthesia. Reg Anesth Pain Med 36(2):185–189CrossRefPubMed
11.
Zurück zum Zitat Horn B, Schunck B (1981) Determining optical flow. Artif Intell 17:185–203CrossRef Horn B, Schunck B (1981) Determining optical flow. Artif Intell 17:185–203CrossRef
12.
Zurück zum Zitat Lucas B, Kanade T (1981) An iterative image registration technique with an application to stereo vision. In: 7th International joint conference on artificial intelligence 81, 674–679 Lucas B, Kanade T (1981) An iterative image registration technique with an application to stereo vision. In: 7th International joint conference on artificial intelligence 81, 674–679
13.
Zurück zum Zitat Matalon TA, Silver B (1990) US guidance of interventional procedures. Radiology 174(1):43–47CrossRefPubMed Matalon TA, Silver B (1990) US guidance of interventional procedures. Radiology 174(1):43–47CrossRefPubMed
14.
Zurück zum Zitat Rosenfeld A (1970) A nonlinear edge detection technique. Proc IEEE lett 58(5):814–816CrossRef Rosenfeld A (1970) A nonlinear edge detection technique. Proc IEEE lett 58(5):814–816CrossRef
15.
Zurück zum Zitat Stiles RN (1976) Frequency and displacement amplitude relations for normal hand tremor. J Appl Physiol 40(1):44–54PubMed Stiles RN (1976) Frequency and displacement amplitude relations for normal hand tremor. J Appl Physiol 40(1):44–54PubMed
16.
Zurück zum Zitat Sviggum HP, Ahn K, Dilger JA, Smith HM (2013) Needle echogenicity in sonographically guided regional anesthesia: blinded comparison of 4 enhanced needles and validation of visual criteria for evaluation. J Ultrasound Med 32(1):143–148PubMed Sviggum HP, Ahn K, Dilger JA, Smith HM (2013) Needle echogenicity in sonographically guided regional anesthesia: blinded comparison of 4 enhanced needles and validation of visual criteria for evaluation. J Ultrasound Med 32(1):143–148PubMed
17.
Zurück zum Zitat Tikhonov AN (1963) On the solution of ill-posed problems and the method of regularization. Doklady Akademii Nauk SSSR 151:501–504 Tikhonov AN (1963) On the solution of ill-posed problems and the method of regularization. Doklady Akademii Nauk SSSR 151:501–504
18.
Zurück zum Zitat Uhercik M, Kybic J, Cachard C, Liebgott H (2009) Line filtering for detection of microtools in 3d ultrasound data. In: IEEE international ultrasonics symposium, pp. 594–597 Uhercik M, Kybic J, Cachard C, Liebgott H (2009) Line filtering for detection of microtools in 3d ultrasound data. In: IEEE international ultrasonics symposium, pp. 594–597
19.
Zurück zum Zitat White LB, Boashash B (1990) Cross spectral analysis of non-stationary processes. IEEE Trans Inf Theory 36(4):830–835CrossRef White LB, Boashash B (1990) Cross spectral analysis of non-stationary processes. IEEE Trans Inf Theory 36(4):830–835CrossRef
20.
Zurück zum Zitat Wu Q, Yuchi M, Ding M (2014) Phase grouping-based needle segmentation in 3D trans-rectal ultrasound-guided prostate trans-perineal therapy. Ultrasound Med Biol 40(4):804–816CrossRef Wu Q, Yuchi M, Ding M (2014) Phase grouping-based needle segmentation in 3D trans-rectal ultrasound-guided prostate trans-perineal therapy. Ultrasound Med Biol 40(4):804–816CrossRef
Metadaten
Titel
Spectral analysis of the tremor motion for needle detection in curvilinear ultrasound via spatiotemporal linear sampling
verfasst von
Parmida Beigi
Robert Rohling
Septimiu E. Salcudean
Gary C. Ng
Publikationsdatum
01.06.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
International Journal of Computer Assisted Radiology and Surgery / Ausgabe 6/2016
Print ISSN: 1861-6410
Elektronische ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-016-1402-7

Weitere Artikel der Ausgabe 6/2016

International Journal of Computer Assisted Radiology and Surgery 6/2016 Zur Ausgabe

Mammakarzinom: Brustdichte beeinflusst rezidivfreies Überleben

26.05.2024 Mammakarzinom Nachrichten

Frauen, die zum Zeitpunkt der Brustkrebsdiagnose eine hohe mammografische Brustdichte aufweisen, haben ein erhöhtes Risiko für ein baldiges Rezidiv, legen neue Daten nahe.

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.