Skip to main content
Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy 9/2006

01.09.2006 | Knee

Intraarticular migration of a broken biodegradable interference screw after anterior cruciate ligament reconstruction

verfasst von: M. H. Baums, B. A. Zelle, W. Schultz, T. Ernstberger, H.-M. Klinger

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 9/2006

Einloggen, um Zugang zu erhalten

Abstract

Poly-l-lactic acid biodegradable screws have been used effectively for graft fixation in anterior cruciate ligament (ACL) reconstruction. The overall complication rate associated with the use of this implant is low, although some authors reported complications, such as osteolysis and aseptic effusion of the knee joint. We report a case of a 29-year-old female patient with a failure of a biodegradable interference screw at 22 months after ACL reconstruction using bone–patellar tendon–bone graft. In this illustrated case, the screw broke and migrated into the knee joint. In addition, we performed a detailed review of the medical literature from 1990–2005 to identify possible causes of biodegradable screw failures. We identified six published cases of bioabsorbable interference screw failure with migration into the knee joint. Several authors have reported small diameter of the screw, poor bone quality, bone resorption, and screw divergence as potential causes for intraarticular migration of metallic interference screws. With regard to bioscrews, no specific risk factors for screw breakage and intraarticular migration have been reported. ACL reconstruction with the use of bioabsorbable interference screws for fixation is considered to be reliable. However, we need to be aware of potential problems associated with the use of this implant. Early recognition of bioscrew failure may prevent associated morbidities, such as subsequent cartilage damage.
Literatur
1.
Zurück zum Zitat Barber FA (1999) Tripled semitendinosus-cancellous bone anterior cruciate ligament reconstruction with bioscrew fixation. Arthroscopy 15:360–367PubMedCrossRef Barber FA (1999) Tripled semitendinosus-cancellous bone anterior cruciate ligament reconstruction with bioscrew fixation. Arthroscopy 15:360–367PubMedCrossRef
2.
Zurück zum Zitat Barber FA, Elrod BF, McGuire DA, Paulos LE (2000) Fixation of patellar tendon autografts. Biomaterials 21:2623–2629CrossRefPubMed Barber FA, Elrod BF, McGuire DA, Paulos LE (2000) Fixation of patellar tendon autografts. Biomaterials 21:2623–2629CrossRefPubMed
3.
Zurück zum Zitat Barrett GR, Papendick L, Miller C (1995) Endobutton endoscopic fixation technique in anterior cruciate ligament reconstruction. Arthroscopy 11:340–343PubMedCrossRef Barrett GR, Papendick L, Miller C (1995) Endobutton endoscopic fixation technique in anterior cruciate ligament reconstruction. Arthroscopy 11:340–343PubMedCrossRef
4.
Zurück zum Zitat Benedetto KP, Fellinger M, Lim TE, Passler JM, Schoen JL, Willems WJ (2000) A new bioabsorbable interference screw: preliminary results of a prospective, multicenter, randomized clinical trial. Arthroscopy 16:41–48PubMedCrossRef Benedetto KP, Fellinger M, Lim TE, Passler JM, Schoen JL, Willems WJ (2000) A new bioabsorbable interference screw: preliminary results of a prospective, multicenter, randomized clinical trial. Arthroscopy 16:41–48PubMedCrossRef
5.
Zurück zum Zitat Bottoni C, DeBerardino T, Fester E, Mitchell D, Penrod BJ (2000) An intra-articular bioabsorbable interference screw mimicking an acute meniscal tear 8 months after an anterior cruciate ligament reconstruction. Arthroscopy 16:395–398PubMedCrossRef Bottoni C, DeBerardino T, Fester E, Mitchell D, Penrod BJ (2000) An intra-articular bioabsorbable interference screw mimicking an acute meniscal tear 8 months after an anterior cruciate ligament reconstruction. Arthroscopy 16:395–398PubMedCrossRef
6.
Zurück zum Zitat Bush-Joseph CA, Bach BR Jr (1998) Migration of femoral interference screw after anterior cruciate ligament reconstruction. Am J Knee Surg 11:32–34PubMed Bush-Joseph CA, Bach BR Jr (1998) Migration of femoral interference screw after anterior cruciate ligament reconstruction. Am J Knee Surg 11:32–34PubMed
7.
Zurück zum Zitat Cerullo G, Puddu G (1993) Arthroscopic placement of the interference screw for anterior cruciate ligament reconstruction. Arthroscopy 9:712–713PubMedCrossRef Cerullo G, Puddu G (1993) Arthroscopic placement of the interference screw for anterior cruciate ligament reconstruction. Arthroscopy 9:712–713PubMedCrossRef
8.
Zurück zum Zitat Doerr AL Jr, Cohn BT, Ruoff MJ, McInerny VK (1990) A complication of interference screw fixation in anterior cruciate ligament reconstruction. Orthop Rev 19:997–1000PubMed Doerr AL Jr, Cohn BT, Ruoff MJ, McInerny VK (1990) A complication of interference screw fixation in anterior cruciate ligament reconstruction. Orthop Rev 19:997–1000PubMed
9.
Zurück zum Zitat Karlakki SL, Downes ME (2003) Intra-articular migration of femoral interference screw: open or arthroscopic removal. Arthroscopy 19:19ECrossRef Karlakki SL, Downes ME (2003) Intra-articular migration of femoral interference screw: open or arthroscopic removal. Arthroscopy 19:19ECrossRef
10.
Zurück zum Zitat Kohn D, Rose C (1994) Primary stability of interference screw fixation. Influence of screw diameter and insertion torque. Am J Sports Med 22:334–338PubMedCrossRef Kohn D, Rose C (1994) Primary stability of interference screw fixation. Influence of screw diameter and insertion torque. Am J Sports Med 22:334–338PubMedCrossRef
11.
Zurück zum Zitat Lembeck B, Wülker N (2005) Severe cartilage damage by broken poly-l-lactic acid (PLLA) interference screw after ACL reconstruction. Knee Surg Sports Traumatol Arthrosc 13:283–286CrossRefPubMed Lembeck B, Wülker N (2005) Severe cartilage damage by broken poly-l-lactic acid (PLLA) interference screw after ACL reconstruction. Knee Surg Sports Traumatol Arthrosc 13:283–286CrossRefPubMed
12.
Zurück zum Zitat Lu HH, Cooper JA Jr, Manuel S, Freeman JW, Attawia MA, Ko FK, Laurencin CT (2005) Anterior cruciate ligament regeneration using braided biodegradable scaffolds: in vitro optimization studies. Biomaterials 26:4805–4816CrossRefPubMed Lu HH, Cooper JA Jr, Manuel S, Freeman JW, Attawia MA, Ko FK, Laurencin CT (2005) Anterior cruciate ligament regeneration using braided biodegradable scaffolds: in vitro optimization studies. Biomaterials 26:4805–4816CrossRefPubMed
13.
Zurück zum Zitat MacDonald P, Arneja S (2003) Biodegradable screw presents as a loose intra-articular body after anterior cruciate ligament reconstruction. Arthroscopy 19: E22–E24PubMedCrossRef MacDonald P, Arneja S (2003) Biodegradable screw presents as a loose intra-articular body after anterior cruciate ligament reconstruction. Arthroscopy 19: E22–E24PubMedCrossRef
14.
Zurück zum Zitat Marti C, Imhoff AB, Bahrs C, Romero J (1997) Metallic versus bioabsorbable interference screw for fixation of bone–patellar tendon–bone autograft in arthroscopic anterior cruciate ligament reconstruction. A preliminary report. Knee Surg Sports Traumatol Arthrosc 5:217–221CrossRefPubMed Marti C, Imhoff AB, Bahrs C, Romero J (1997) Metallic versus bioabsorbable interference screw for fixation of bone–patellar tendon–bone autograft in arthroscopic anterior cruciate ligament reconstruction. A preliminary report. Knee Surg Sports Traumatol Arthrosc 5:217–221CrossRefPubMed
15.
Zurück zum Zitat Martinek V, Friederich NF (1999) Tibial and pretibial cyst formation after anterior cruciate ligament reconstruction with bioabsorbable interference screw fixation. Arthroscopy 15:317–320PubMedCrossRef Martinek V, Friederich NF (1999) Tibial and pretibial cyst formation after anterior cruciate ligament reconstruction with bioabsorbable interference screw fixation. Arthroscopy 15:317–320PubMedCrossRef
16.
Zurück zum Zitat Morgan CD, Gehrmann RM, Jayo MJ, Johnson CS (2002) Histologic findings with a bioabsorbable anterior cruciate ligament interference screw explant after 2.5 years in vivo. Arthroscopy 18:E47PubMedCrossRef Morgan CD, Gehrmann RM, Jayo MJ, Johnson CS (2002) Histologic findings with a bioabsorbable anterior cruciate ligament interference screw explant after 2.5 years in vivo. Arthroscopy 18:E47PubMedCrossRef
17.
Zurück zum Zitat Rodeo SA, Arnoczky SP, Torzilli PA, Hidaka C, Warren RF (1993) Tendon-healing in a bone tunnel. A biomechanical and histological study in dog. J Bone Joint Surg Am 75-A:1795–1803 Rodeo SA, Arnoczky SP, Torzilli PA, Hidaka C, Warren RF (1993) Tendon-healing in a bone tunnel. A biomechanical and histological study in dog. J Bone Joint Surg Am 75-A:1795–1803
18.
Zurück zum Zitat Shafer BL, Simonian PT (2002) Broken poly-l-lactic acid interference screw after ligament reconstruction. Arthroscopy 18:E35PubMedCrossRef Shafer BL, Simonian PT (2002) Broken poly-l-lactic acid interference screw after ligament reconstruction. Arthroscopy 18:E35PubMedCrossRef
19.
Zurück zum Zitat Sidhu DS, Wroble RR (1997) Intraarticular migration of a femoral interference fit screw. A complication of anterior cruciate ligament reconstruction. Am J Sports Med 25:268–271PubMedCrossRef Sidhu DS, Wroble RR (1997) Intraarticular migration of a femoral interference fit screw. A complication of anterior cruciate ligament reconstruction. Am J Sports Med 25:268–271PubMedCrossRef
20.
Zurück zum Zitat Stähelin AC, Weiler A, Rüfenacht H, Hoffmann R, Geissmann A, Feinstein R. (1997) Clinical degradation and biocompatibility of different bioabsorbable interference screws: a report of six cases. Arthroscopy 13:238–244PubMedCrossRef Stähelin AC, Weiler A, Rüfenacht H, Hoffmann R, Geissmann A, Feinstein R. (1997) Clinical degradation and biocompatibility of different bioabsorbable interference screws: a report of six cases. Arthroscopy 13:238–244PubMedCrossRef
21.
Zurück zum Zitat Stähelin AC, Südkamp NP, Weiler A (2001) Anatomic double-bundle posterior cruciate ligament reconstruction using hamstring tendons. Arthroscopy 17:88–97PubMedCrossRef Stähelin AC, Südkamp NP, Weiler A (2001) Anatomic double-bundle posterior cruciate ligament reconstruction using hamstring tendons. Arthroscopy 17:88–97PubMedCrossRef
22.
Zurück zum Zitat Werner A, Wild A, Ilg A, Krauspe R (2002) Secondary intra-articular dislocation of a broken bioabsorbable interference screw after anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc 10:30–32CrossRefPubMed Werner A, Wild A, Ilg A, Krauspe R (2002) Secondary intra-articular dislocation of a broken bioabsorbable interference screw after anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc 10:30–32CrossRefPubMed
Metadaten
Titel
Intraarticular migration of a broken biodegradable interference screw after anterior cruciate ligament reconstruction
verfasst von
M. H. Baums
B. A. Zelle
W. Schultz
T. Ernstberger
H.-M. Klinger
Publikationsdatum
01.09.2006
Verlag
Springer-Verlag
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 9/2006
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-006-0049-2

Weitere Artikel der Ausgabe 9/2006

Knee Surgery, Sports Traumatology, Arthroscopy 9/2006 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders gilt das offenbar für weibliche Kranke, wie eine Studie zeigt.

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.