Comparison of femoral fixation methods for anterior cruciate ligament reconstruction with patellar tendon graft: a mechanical analysis in porcine knees

verfasst von: Giuseppe Milano, Pier Damiano Mulas, Fabio Ziranu, Laura Deriu, Carlo Fabbriciani

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 6/2007

Einloggen, um Zugang zu erhalten

Abstract

The aim of the present study was to evaluate the structural properties of femur–patellar tendon graft complex in anterior cruciate ligament (ACL) reconstruction using different femoral fixation devices. Type of study is biomechanical testing. An ACL reconstruction was performed on 40 cadaver porcine knees, using patellar tendon (PT) graft. Specimens were divided into four groups according to the femoral fixation: interference absorbable screw (Group A), metallic setscrew (Group B), absorbable pins (Group C), and a combination of metallic setscrew and pin (Group D). Other ten knees were used as controls. On each sample, a cyclic loading test, then a load-to-failure test were performed. Elongation after 1,000 loading cycles, ultimate failure load, yield load, stiffness, deformation at the yield point, and mode of failure were recorded. Kruskal–Wallis test and Tukey test were used to compare the differences between groups. The lowest mean elongation after 1,000 load cycles was observed for Group B (1.7 ± 1.4 mm) and D (1.2 ± 0.3 mm). Ultimate failure load of Group D (1,021.8 ± 199.4 N) was comparable with that of normal ACL (1,091.2 ± 193.3 N) and PT graft (1,140.6 ± 285.7 N). All other groups were lower than the controls. For mean stiffness, all the groups, excepting for Group D (172.8 ± 40.4 N/mm), were significantly lower than PT control group (216 ± 78.4 N/mm). Mode of failure was graft pullout for Groups A and B, distal pin breakage for Group C, and midsubstance graft rupture in 80% of the cases for Group D. Only combined compression and suspension fixation did not show significantly different structural properties in comparison with normal ACL and PT graft. Furthermore, it showed no risk of graft pullout or hardware breakdown in comparison with other fixation devices.
Literatur
1.
Zurück zum Zitat Brown CH Jr, Hecker AT, Hipp JA et al (1993) The biomechanics of interference screw fixation of patellar tendon anterior cruciate ligament grafts. Am J Sports Med 21:880–886PubMed Brown CH Jr, Hecker AT, Hipp JA et al (1993) The biomechanics of interference screw fixation of patellar tendon anterior cruciate ligament grafts. Am J Sports Med 21:880–886PubMed
2.
Zurück zum Zitat Brown G, Pena F, Grontvedt T et al (1996) Fixation strength of interference screw fixation in bovine, young human, and elderly human cadaver knees: influence of insertion torque, tunnel-bone block gap, and interference. Knee Surg Sports Traumatol Arthrosc 3:238–244PubMedCrossRef Brown G, Pena F, Grontvedt T et al (1996) Fixation strength of interference screw fixation in bovine, young human, and elderly human cadaver knees: influence of insertion torque, tunnel-bone block gap, and interference. Knee Surg Sports Traumatol Arthrosc 3:238–244PubMedCrossRef
3.
Zurück zum Zitat Butler JC, Branch TP, Hutton WC (1994) Optimal graft fixation. The effect of gap size and screw size on bone plug fixation in ACL reconstruction. Arthroscopy 10:524–529PubMedCrossRef Butler JC, Branch TP, Hutton WC (1994) Optimal graft fixation. The effect of gap size and screw size on bone plug fixation in ACL reconstruction. Arthroscopy 10:524–529PubMedCrossRef
4.
Zurück zum Zitat Caborn DN, Urban WP Jr, Johnson DL et al (1997) Biomechanical comparison between BioScrew and titanium alloy interference screws for bone–patellar tendon–bone graft fixation in anterior cruciate ligament reconstruction. Arthroscopy 13:229–232PubMedCrossRef Caborn DN, Urban WP Jr, Johnson DL et al (1997) Biomechanical comparison between BioScrew and titanium alloy interference screws for bone–patellar tendon–bone graft fixation in anterior cruciate ligament reconstruction. Arthroscopy 13:229–232PubMedCrossRef
5.
Zurück zum Zitat Camillieri G, McFarland EG, Jasper LE, Belkoff SM, Kim TK, Rauh PB, Mariani PP (2004) A biomechanical evaluation of transcondylar femoral fixation of anterior cruciate ligament grafts. Am J Sports Med 32:950–955PubMedCrossRef Camillieri G, McFarland EG, Jasper LE, Belkoff SM, Kim TK, Rauh PB, Mariani PP (2004) A biomechanical evaluation of transcondylar femoral fixation of anterior cruciate ligament grafts. Am J Sports Med 32:950–955PubMedCrossRef
6.
Zurück zum Zitat Chang HC, Nyland J, Nawab A, Burden R, Caborn DN (2005) Biomechanical comparison of the bioabsorbable RetroScrew system, BioScrew XtraLok with stress equalization tensioner, and 35 mm delta screws for tibialis anterior graft-tibial tunnel fixation in porcine tibiae. Am J Sports Med 33:1057–1064PubMedCrossRef Chang HC, Nyland J, Nawab A, Burden R, Caborn DN (2005) Biomechanical comparison of the bioabsorbable RetroScrew system, BioScrew XtraLok with stress equalization tensioner, and 35 mm delta screws for tibialis anterior graft-tibial tunnel fixation in porcine tibiae. Am J Sports Med 33:1057–1064PubMedCrossRef
7.
Zurück zum Zitat Cooper DE, Deng XH, Burstein AL (1993) The strength of the central third patellar tendon graft. A biomechanical study. Am J Sports Med 21:818–824PubMed Cooper DE, Deng XH, Burstein AL (1993) The strength of the central third patellar tendon graft. A biomechanical study. Am J Sports Med 21:818–824PubMed
8.
Zurück zum Zitat Graf B, Uhr F (1988) Complications of intra-articular cruciate reconstruction. Clin Sports Med 7:835–848PubMed Graf B, Uhr F (1988) Complications of intra-articular cruciate reconstruction. Clin Sports Med 7:835–848PubMed
9.
Zurück zum Zitat Hackl W, Fink C, Benedetto KP, Hoser C (2000) Transplant fixation by anterior cruciate ligament reconstruction. Metal vs. bioabsorbable polyglyconate interference screw. A prospective randomized study of 40 patients. Unfallchirurg 103:468–474PubMedCrossRef Hackl W, Fink C, Benedetto KP, Hoser C (2000) Transplant fixation by anterior cruciate ligament reconstruction. Metal vs. bioabsorbable polyglyconate interference screw. A prospective randomized study of 40 patients. Unfallchirurg 103:468–474PubMedCrossRef
10.
Zurück zum Zitat Hammond GW, Armstrong KL, McGarry MH, Lee TQ (2006) Hybrid fixation improves structural properties of a free tendon anterior cruciate ligament reconstruction. Arthroscopy 22:781–786PubMedCrossRef Hammond GW, Armstrong KL, McGarry MH, Lee TQ (2006) Hybrid fixation improves structural properties of a free tendon anterior cruciate ligament reconstruction. Arthroscopy 22:781–786PubMedCrossRef
11.
Zurück zum Zitat Johnson LL, Van Dyk GE (1996) Metal and biodegradable interference screws: comparison of failure strength. Arthroscopy 12:452–456PubMedCrossRef Johnson LL, Van Dyk GE (1996) Metal and biodegradable interference screws: comparison of failure strength. Arthroscopy 12:452–456PubMedCrossRef
12.
Zurück zum Zitat Jomha NM Raso VJ, Leung P (1993) Effect of varying angles on the pullout strength of interference screw fixation. Arthroscopy 9:580–583CrossRef Jomha NM Raso VJ, Leung P (1993) Effect of varying angles on the pullout strength of interference screw fixation. Arthroscopy 9:580–583CrossRef
13.
Zurück zum Zitat Kaeding C, Farr J, Kavanaugh T, Pedroza A (2005) A prospective randomized comparison of bioabsorbable and titanium anterior cruciate ligament interference screws. Arthroscopy 21:147–151PubMedCrossRef Kaeding C, Farr J, Kavanaugh T, Pedroza A (2005) A prospective randomized comparison of bioabsorbable and titanium anterior cruciate ligament interference screws. Arthroscopy 21:147–151PubMedCrossRef
14.
Zurück zum Zitat Kohn D, Rose C (1994) Primary stability of interference screw fixation: influence of screw diameter and insertion torque. Am J Sports Med 22:334–338PubMed Kohn D, Rose C (1994) Primary stability of interference screw fixation: influence of screw diameter and insertion torque. Am J Sports Med 22:334–338PubMed
15.
Zurück zum Zitat Kotani A, Ishii Y (2001) Reconstruction of the anterior cruciate ligament using poly-l-lactide interference screws or titanium screws: a comparative study. Knee 8:311–315PubMedCrossRef Kotani A, Ishii Y (2001) Reconstruction of the anterior cruciate ligament using poly-l-lactide interference screws or titanium screws: a comparative study. Knee 8:311–315PubMedCrossRef
16.
Zurück zum Zitat Kousa P, Jarvinen TL, Kannus P et al (2001) Initial fixation strength of bioabsorbable and titanium interference screws in anterior cruciate ligament reconstruction. Biomechanical evaluation by single cycle and cyclic loading. Am J Sports Med 29:420–425PubMed Kousa P, Jarvinen TL, Kannus P et al (2001) Initial fixation strength of bioabsorbable and titanium interference screws in anterior cruciate ligament reconstruction. Biomechanical evaluation by single cycle and cyclic loading. Am J Sports Med 29:420–425PubMed
17.
Zurück zum Zitat Mariani PP, Camillieri G, Margheritini F (2001) Transcondylar screw fixation in anterior cruciate ligament reconstruction. Arthroscopy 17:717–723PubMedCrossRef Mariani PP, Camillieri G, Margheritini F (2001) Transcondylar screw fixation in anterior cruciate ligament reconstruction. Arthroscopy 17:717–723PubMedCrossRef
18.
Zurück zum Zitat Matthews LS, Soffer SR (1989) Pitfalls in the use of interference screws for anterior cruciate ligament reconstruction: brief report. Arthroscopy 5:225–226PubMedCrossRef Matthews LS, Soffer SR (1989) Pitfalls in the use of interference screws for anterior cruciate ligament reconstruction: brief report. Arthroscopy 5:225–226PubMedCrossRef
19.
Zurück zum Zitat Milano G, Mulas PD, Ziranu F, Piras S, Manunta A, Fabbriciani C (2006) Comparison between different femoral fixation devices for ACL reconstruction with doubled hamstring tendon graft: a biomechanical analysis. Arthroscopy 22:660–668PubMedCrossRef Milano G, Mulas PD, Ziranu F, Piras S, Manunta A, Fabbriciani C (2006) Comparison between different femoral fixation devices for ACL reconstruction with doubled hamstring tendon graft: a biomechanical analysis. Arthroscopy 22:660–668PubMedCrossRef
20.
Zurück zum Zitat Nakano H, Yasuda K, Tohyama H, Yamanaka M, Wada T, Kaneda K (2000) Interference screw fixation of doubled flexor tendon graft in anterior cruciate ligament reconstruction—biomechanical evaluation with cyclic elongation. Clin Biomech 15:188–195CrossRef Nakano H, Yasuda K, Tohyama H, Yamanaka M, Wada T, Kaneda K (2000) Interference screw fixation of doubled flexor tendon graft in anterior cruciate ligament reconstruction—biomechanical evaluation with cyclic elongation. Clin Biomech 15:188–195CrossRef
21.
Zurück zum Zitat Nurmi JT, Jarvinen TL, Kannus P, Sievanen H, Toukosalo J, Jarvinen M (2002) Compaction versus extraction drilling for fixation of the hamstring tendon graft in anterior cruciate ligament reconstruction. Am J Sports Med 30:167–173PubMed Nurmi JT, Jarvinen TL, Kannus P, Sievanen H, Toukosalo J, Jarvinen M (2002) Compaction versus extraction drilling for fixation of the hamstring tendon graft in anterior cruciate ligament reconstruction. Am J Sports Med 30:167–173PubMed
22.
Zurück zum Zitat Pena F Grontvedt T, Brown GA et al (1996) Comparison of failure strength between metallic and absorbable interference screws. Influence of insertion torque, tunnel-bone block gap, bone mineral density, and interference. Am J Sports Med 24:329–334 Pena F Grontvedt T, Brown GA et al (1996) Comparison of failure strength between metallic and absorbable interference screws. Influence of insertion torque, tunnel-bone block gap, bone mineral density, and interference. Am J Sports Med 24:329–334
23.
Zurück zum Zitat Pierz K, Baltz M, Fulkerson J (1995) The effect of Kurosaka screw divergence on the holding strength of bone–tendon–bone grafts. Am J Sports Med 23:332–335PubMed Pierz K, Baltz M, Fulkerson J (1995) The effect of Kurosaka screw divergence on the holding strength of bone–tendon–bone grafts. Am J Sports Med 23:332–335PubMed
24.
Zurück zum Zitat Pujol N, David T, Bauer T, Hardy P (2006) Transverse femoral fixation in anterior cruciate ligament (ACL) reconstruction with hamstrings grafts: an anatomic study about the relationships between the transcondylar device and the posterolateral structures of the knee. Knee Surg Sports Traumatol Arthrosc 14:724–729PubMedCrossRef Pujol N, David T, Bauer T, Hardy P (2006) Transverse femoral fixation in anterior cruciate ligament (ACL) reconstruction with hamstrings grafts: an anatomic study about the relationships between the transcondylar device and the posterolateral structures of the knee. Knee Surg Sports Traumatol Arthrosc 14:724–729PubMedCrossRef
25.
Zurück zum Zitat Rupp S, Krauss PW. Fritsch EW (1997) Fixation strength of a biodegradable intenerence screw and a press-fit technique in anterior cruciate ligament reconstruction with a BPTB graft. Arthroscopy 13:61–65PubMedCrossRef Rupp S, Krauss PW. Fritsch EW (1997) Fixation strength of a biodegradable intenerence screw and a press-fit technique in anterior cruciate ligament reconstruction with a BPTB graft. Arthroscopy 13:61–65PubMedCrossRef
26.
Zurück zum Zitat Safran MR, Harner CD (1996) Technical considerations of revision anterior cruciate surgery. Clin Orthop 325:50–65PubMedCrossRef Safran MR, Harner CD (1996) Technical considerations of revision anterior cruciate surgery. Clin Orthop 325:50–65PubMedCrossRef
27.
Zurück zum Zitat Seil R, Rupp S, Krauss PW et al (1998) Comparison of initial fixation strength between biodegradable and metallic interference screws and a press-fit fixation technique in a porcine model. Am J Sports Med 26:815–819PubMed Seil R, Rupp S, Krauss PW et al (1998) Comparison of initial fixation strength between biodegradable and metallic interference screws and a press-fit fixation technique in a porcine model. Am J Sports Med 26:815–819PubMed
28.
Zurück zum Zitat Shafer BL, Simonian PT (2002) Broken poly-l-lactic acid interference screw after ligament reconstruction. Arthroscopy 18:E35PubMedCrossRef Shafer BL, Simonian PT (2002) Broken poly-l-lactic acid interference screw after ligament reconstruction. Arthroscopy 18:E35PubMedCrossRef
29.
Zurück zum Zitat Shapiro JD, Cohn BT, Jackson DW et al (1992) The biomechanical effects of geometric configuration of bone–tendon–bone autografts in anterior cruciate ligament reconstruction. Arthroscopy 8:453–458PubMedCrossRef Shapiro JD, Cohn BT, Jackson DW et al (1992) The biomechanical effects of geometric configuration of bone–tendon–bone autografts in anterior cruciate ligament reconstruction. Arthroscopy 8:453–458PubMedCrossRef
30.
Zurück zum Zitat Shapiro JD, Jackson DW, Aberman HM et al (1995) Comparison of pull-out strength for seven- and nine-millimeter diameter interference screw size as used in anterior cruciate ligament reconstruction. Arthroscopy 11:596–599PubMedCrossRef Shapiro JD, Jackson DW, Aberman HM et al (1995) Comparison of pull-out strength for seven- and nine-millimeter diameter interference screw size as used in anterior cruciate ligament reconstruction. Arthroscopy 11:596–599PubMedCrossRef
31.
Zurück zum Zitat Sidhu DS, Wroble RR (1997) Intraarticular migration of a femoral interference fit screw. A complication of anterior cruciate ligament reconstruction. Am J Sports Med 25:268–271PubMed Sidhu DS, Wroble RR (1997) Intraarticular migration of a femoral interference fit screw. A complication of anterior cruciate ligament reconstruction. Am J Sports Med 25:268–271PubMed
32.
Zurück zum Zitat Weiler A, Windhagen HJ, Raschke MJ et al (1998) Biodegradable interference screw fixation exhibits pull-out force and stiffness similar to titanium screws. Am J Sports Med 26:119–128PubMedCrossRef Weiler A, Windhagen HJ, Raschke MJ et al (1998) Biodegradable interference screw fixation exhibits pull-out force and stiffness similar to titanium screws. Am J Sports Med 26:119–128PubMedCrossRef
33.
Zurück zum Zitat Weimann A, Zantop T, Rummler M et al (2003) Primary stability of bone–patellar tendon–bone graft fixation with biodegradable pins. Arthroscopy 19:1097–1102PubMedCrossRef Weimann A, Zantop T, Rummler M et al (2003) Primary stability of bone–patellar tendon–bone graft fixation with biodegradable pins. Arthroscopy 19:1097–1102PubMedCrossRef
34.
Zurück zum Zitat Woo SL-Y, Hollis JM, Adams DJ et al (1991) Tensile properties of the human femur–anterior cruciate ligament-tibia complex. The effects of specimen age and orientation. Am J Sports Med 19:217–225PubMed Woo SL-Y, Hollis JM, Adams DJ et al (1991) Tensile properties of the human femur–anterior cruciate ligament-tibia complex. The effects of specimen age and orientation. Am J Sports Med 19:217–225PubMed
35.
Zurück zum Zitat Zantop T, Ruemmler M, Welbers B, Langer M, Weimann A, Petersen W (2005) Cyclic loading comparison between biodegradable interference screw fixation and biodegradable double cross pin fixation of human bone–patellar tendon–bone grafts. Arthroscopy 21:934–941PubMedCrossRef Zantop T, Ruemmler M, Welbers B, Langer M, Weimann A, Petersen W (2005) Cyclic loading comparison between biodegradable interference screw fixation and biodegradable double cross pin fixation of human bone–patellar tendon–bone grafts. Arthroscopy 21:934–941PubMedCrossRef
Metadaten
Titel
Comparison of femoral fixation methods for anterior cruciate ligament reconstruction with patellar tendon graft: a mechanical analysis in porcine knees
verfasst von
Giuseppe Milano
Pier Damiano Mulas
Fabio Ziranu
Laura Deriu
Carlo Fabbriciani
Publikationsdatum
01.06.2007
Verlag
Springer-Verlag
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 6/2007
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-006-0269-5

Weitere Artikel der Ausgabe 6/2007

Knee Surgery, Sports Traumatology, Arthroscopy 6/2007 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.