Skip to main content
Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy 3/2009

01.03.2009 | Knee

Two year follow-up comparing computer assisted versus freehand TKR on joint stability, muscular function and patients satisfaction

verfasst von: C. Lüring, F. Oczipka, L. Perlick, M. Tingart, J. Grifka, H. Bäthis

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 3/2009

Einloggen, um Zugang zu erhalten

Abstract

Computer assisted (CAS) knee surgery has been established in clinical routine. There is still no study that investigates clinical outcome. Fifty patients who received a primary total knee replacement 2 years before were investigated. These patients were divided into two groups of matched-pairs; group A was operated in the freehand technique and group B with support of a computer system. We compared Womac score, Knee Society score, range of motion, leg alignment, knee stability and isokinetic muscle strength. We found similar results for WOMAC, Knee Society score and isokinetic muscle force. Stability and range of motion revealed slightly better values for the CAS group. A statistically significant difference could only be demonstrated for postoperative leg alignment. Two years after freehand versus computer assisted TKR we found slightly better values for range of motion and ligamentous stability. Only postoperative leg alignment was statistically better in the CAS group.
Literatur
1.
Zurück zum Zitat Bachmeier C, March L, Cross M, Lapsley H, Tribe K, Courtenay K (2001) A comparison of outcomes in osteoarthritis patients undergoing THR and TKR. Osteoarthritis Cartilage 9:137–146PubMedCrossRef Bachmeier C, March L, Cross M, Lapsley H, Tribe K, Courtenay K (2001) A comparison of outcomes in osteoarthritis patients undergoing THR and TKR. Osteoarthritis Cartilage 9:137–146PubMedCrossRef
2.
Zurück zum Zitat Bäthis H, Perlick L, Tingart M, Luring C, Zurakowski D, Grifka J (2004) Alignment in total knee arthroplasty: a comparison of computer-assisted implantation with the conventional technique. J Bone Joint Surg Br 86:682–687PubMedCrossRef Bäthis H, Perlick L, Tingart M, Luring C, Zurakowski D, Grifka J (2004) Alignment in total knee arthroplasty: a comparison of computer-assisted implantation with the conventional technique. J Bone Joint Surg Br 86:682–687PubMedCrossRef
3.
Zurück zum Zitat Bauwens K, Matthes G, Wich M, Gebhard F, Hanson B, Ekkernkamp A, Stengel D (2007) Navigated total knee replacement. A meta-analysis. J Bone Joint Surg Am 89:261–269PubMedCrossRef Bauwens K, Matthes G, Wich M, Gebhard F, Hanson B, Ekkernkamp A, Stengel D (2007) Navigated total knee replacement. A meta-analysis. J Bone Joint Surg Am 89:261–269PubMedCrossRef
4.
Zurück zum Zitat Bellamy N, Buchanan WW, Goldsmith CH, Campbell J, Stitt LW (1988) Validation studyof WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee. J Rheumatol 15:1833–1840PubMed Bellamy N, Buchanan WW, Goldsmith CH, Campbell J, Stitt LW (1988) Validation studyof WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee. J Rheumatol 15:1833–1840PubMed
5.
Zurück zum Zitat Bellamy N, Campbell J, Stevens J, Pilch L, Stewart C, Mahmood Z (1997) Validation study of a computerized version of the western Ontario and McMaster Universities VA 3.0 Osteoarthritis index. J Rheumatol 24:2413–2415PubMed Bellamy N, Campbell J, Stevens J, Pilch L, Stewart C, Mahmood Z (1997) Validation study of a computerized version of the western Ontario and McMaster Universities VA 3.0 Osteoarthritis index. J Rheumatol 24:2413–2415PubMed
6.
Zurück zum Zitat Bolognesi M, Hofmann A (2005) Computer navigation versus standard instrumentation for TKA: a single-surgeon experience. Clin Orthop Relat Res 440:162–169PubMedCrossRef Bolognesi M, Hofmann A (2005) Computer navigation versus standard instrumentation for TKA: a single-surgeon experience. Clin Orthop Relat Res 440:162–169PubMedCrossRef
7.
Zurück zum Zitat Chen FS, Scher DM, Clancy RM, Ayesha V-Y, DiCesare PE (1999) In vitro and in vivo activation of polymorphonuclear leukocytes in response to particulate debris. J Biomed Mater Res 48:904–912PubMedCrossRef Chen FS, Scher DM, Clancy RM, Ayesha V-Y, DiCesare PE (1999) In vitro and in vivo activation of polymorphonuclear leukocytes in response to particulate debris. J Biomed Mater Res 48:904–912PubMedCrossRef
8.
Zurück zum Zitat Delp SL, Stulberg SD, Davies B, Picard F, Leitner F (1998) Computer assisted knee replacement. Clin Orthop 355:49–56 Delp SL, Stulberg SD, Davies B, Picard F, Leitner F (1998) Computer assisted knee replacement. Clin Orthop 355:49–56
9.
Zurück zum Zitat Font-Rodriguez DE, Scuderi GR, Insall JN (1997) Survivorship of cemented total knee arthroplasty. Clin Orthop 345:79–86PubMed Font-Rodriguez DE, Scuderi GR, Insall JN (1997) Survivorship of cemented total knee arthroplasty. Clin Orthop 345:79–86PubMed
10.
Zurück zum Zitat Glant TT, Jacobs JJ (1994) Response of three murine macrophage populations to particulate debris: bone resorption in organ cultures. J Orthop Res 12:720–731PubMedCrossRef Glant TT, Jacobs JJ (1994) Response of three murine macrophage populations to particulate debris: bone resorption in organ cultures. J Orthop Res 12:720–731PubMedCrossRef
11.
Zurück zum Zitat Haaker RG, Stockheim M, Kamp M, Proff G, Breitenfelder J, Ottersbach A (2005) Computer-assisted navigation increases precision of component placement in total knee arthroplasty. Clin Orthop Relat Res 433:152–159PubMedCrossRef Haaker RG, Stockheim M, Kamp M, Proff G, Breitenfelder J, Ottersbach A (2005) Computer-assisted navigation increases precision of component placement in total knee arthroplasty. Clin Orthop Relat Res 433:152–159PubMedCrossRef
12.
Zurück zum Zitat Insall JN, Dorr LD, Scott R, Scott WN (1989) Rationale of the knee society clinical rating system. Clin Orthop 248:13–14PubMed Insall JN, Dorr LD, Scott R, Scott WN (1989) Rationale of the knee society clinical rating system. Clin Orthop 248:13–14PubMed
13.
Zurück zum Zitat Jacobs JJ, Gilbert JL, Urban RM (1998) Corrosion of metal orthopaedic implants. J Bone Joint Surg Am 80:268–282PubMed Jacobs JJ, Gilbert JL, Urban RM (1998) Corrosion of metal orthopaedic implants. J Bone Joint Surg Am 80:268–282PubMed
14.
Zurück zum Zitat Jenny JY, Clemens U, Kohler S, Kiefer H, Konermann W, Miehlke RK (2005) Consistency of implantation of a total knee arthroplasty with a non-image-based navigation system: a case-control study of 235 cases compared with 235 conventionally implanted prostheses. J Arthroplasty 20:832–889PubMedCrossRef Jenny JY, Clemens U, Kohler S, Kiefer H, Konermann W, Miehlke RK (2005) Consistency of implantation of a total knee arthroplasty with a non-image-based navigation system: a case-control study of 235 cases compared with 235 conventionally implanted prostheses. J Arthroplasty 20:832–889PubMedCrossRef
15.
Zurück zum Zitat Kubo T, Sawada K, Hirakawa K, Shimizu C, Takamatsu T, Hirasawa Y (1999) Histiocyte reaction in rabbit femurs to UHMWPE, metal and ceramic particles in different sizes. J Biomed Mater Res 45:363–369PubMedCrossRef Kubo T, Sawada K, Hirakawa K, Shimizu C, Takamatsu T, Hirasawa Y (1999) Histiocyte reaction in rabbit femurs to UHMWPE, metal and ceramic particles in different sizes. J Biomed Mater Res 45:363–369PubMedCrossRef
16.
Zurück zum Zitat Laskin RS (2003) Instrumentation pitfalls: you just can’t go on autopilot! J Arthroplasty 18:18–22PubMedCrossRef Laskin RS (2003) Instrumentation pitfalls: you just can’t go on autopilot! J Arthroplasty 18:18–22PubMedCrossRef
17.
Zurück zum Zitat Lüring C, Bathis H, Oczipka F, Trepte H, Lufen H, Perlick L, Grifka J (2006) Two-year follow-up on joint stability and muscular function comparing Rotating vs fixed bearing TKR. Knee Surg Sports Traumatol Arthrosc 14:605–611PubMedCrossRef Lüring C, Bathis H, Oczipka F, Trepte H, Lufen H, Perlick L, Grifka J (2006) Two-year follow-up on joint stability and muscular function comparing Rotating vs fixed bearing TKR. Knee Surg Sports Traumatol Arthrosc 14:605–611PubMedCrossRef
18.
Zurück zum Zitat Lützner J, Krummenauer F, Wolf C, Günther KP, Kirschner S (2008) Computer-assisted and conventional total knee replacement: a comparative, prospective, randomised study with radiological and CT evaluation. J Bone Joint Surg Br 90:1039–1044PubMedCrossRef Lützner J, Krummenauer F, Wolf C, Günther KP, Kirschner S (2008) Computer-assisted and conventional total knee replacement: a comparative, prospective, randomised study with radiological and CT evaluation. J Bone Joint Surg Br 90:1039–1044PubMedCrossRef
19.
Zurück zum Zitat Mahaluxmivala J, Bankes MJ, Nicolai P, Aldam CJH, Allen PW (2001) The effect of surgeon experience on component positioning in 673 press fit condylar posterior cruciate-sacrificing total knee arthroplasties. J Arthroplasty 16:635–640PubMedCrossRef Mahaluxmivala J, Bankes MJ, Nicolai P, Aldam CJH, Allen PW (2001) The effect of surgeon experience on component positioning in 673 press fit condylar posterior cruciate-sacrificing total knee arthroplasties. J Arthroplasty 16:635–640PubMedCrossRef
20.
Zurück zum Zitat Martin A, von Strempel A (2006) Two year outcomes of computed tomography-based and computed tomography free navigation for total knee arthroplasties. Clin Orthop Relat Res 449:275–282PubMed Martin A, von Strempel A (2006) Two year outcomes of computed tomography-based and computed tomography free navigation for total knee arthroplasties. Clin Orthop Relat Res 449:275–282PubMed
21.
Zurück zum Zitat Novotny J, Gonzalez MH, Amirouche FM, Li YC (2001) Geometric analysis of potential error in using femoral intramedullary guides in total knee arthroplasty. J Arthroplasty 16:641–647PubMedCrossRef Novotny J, Gonzalez MH, Amirouche FM, Li YC (2001) Geometric analysis of potential error in using femoral intramedullary guides in total knee arthroplasty. J Arthroplasty 16:641–647PubMedCrossRef
22.
Zurück zum Zitat Petersen TL, Engh GA (1988) Radiographic assessment of knee alignment after total knee arthroplasty. J Arthroplasty 3:67–72PubMedCrossRef Petersen TL, Engh GA (1988) Radiographic assessment of knee alignment after total knee arthroplasty. J Arthroplasty 3:67–72PubMedCrossRef
23.
Zurück zum Zitat Reed SC, Gollish J (1997) The accuracy of femoral intramedullary guides in total knee arthroplasty. J Arthroplasty 12:677–682PubMedCrossRef Reed SC, Gollish J (1997) The accuracy of femoral intramedullary guides in total knee arthroplasty. J Arthroplasty 12:677–682PubMedCrossRef
24.
Zurück zum Zitat Rodriguez JA, Bhende H, Ranawatt CS (2001) Total condylar knee replacement: a 20-year followup study. Clin Orthop 288:10–17 Rodriguez JA, Bhende H, Ranawatt CS (2001) Total condylar knee replacement: a 20-year followup study. Clin Orthop 288:10–17
25.
Zurück zum Zitat Sparmann M, Wolke B, Czupalla H, Banzer D, Zink A (2003) Positioning of total knee arthroplasty with and without navigation support. A prospective, randomised study. J Bone Joint Surg Br 85:830–835PubMed Sparmann M, Wolke B, Czupalla H, Banzer D, Zink A (2003) Positioning of total knee arthroplasty with and without navigation support. A prospective, randomised study. J Bone Joint Surg Br 85:830–835PubMed
26.
Zurück zum Zitat Stähelin T, Kessler O, Pfirrmann C, Jacob HAC, Romero J (2003) Fluoroscopically assisted stress radiography for varus-valgus stability in flexion after total knee arthroplasty. J Arthroplasty 18:513–515PubMedCrossRef Stähelin T, Kessler O, Pfirrmann C, Jacob HAC, Romero J (2003) Fluoroscopically assisted stress radiography for varus-valgus stability in flexion after total knee arthroplasty. J Arthroplasty 18:513–515PubMedCrossRef
27.
Zurück zum Zitat Tingart M, Lüring C, Bäthis H, Beckmann J, Grifka J, Perlick L (2008) Computer-assisted total knee arthroplasty versus the conventional technique: how precise is navigation in clinical routine? Knee Surg Sports Traumatol Arthrosc 16:44–50PubMedCrossRef Tingart M, Lüring C, Bäthis H, Beckmann J, Grifka J, Perlick L (2008) Computer-assisted total knee arthroplasty versus the conventional technique: how precise is navigation in clinical routine? Knee Surg Sports Traumatol Arthrosc 16:44–50PubMedCrossRef
28.
Zurück zum Zitat Woolson ST, Northrop GD (2004) Mobile versus fixed-bearing total knee arthroplasty. A clinical and radiologic study. J Arthroplasty 19:135–140PubMedCrossRef Woolson ST, Northrop GD (2004) Mobile versus fixed-bearing total knee arthroplasty. A clinical and radiologic study. J Arthroplasty 19:135–140PubMedCrossRef
Metadaten
Titel
Two year follow-up comparing computer assisted versus freehand TKR on joint stability, muscular function and patients satisfaction
verfasst von
C. Lüring
F. Oczipka
L. Perlick
M. Tingart
J. Grifka
H. Bäthis
Publikationsdatum
01.03.2009
Verlag
Springer-Verlag
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 3/2009
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-008-0644-5

Weitere Artikel der Ausgabe 3/2009

Knee Surgery, Sports Traumatology, Arthroscopy 3/2009 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.