Skip to main content
Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy 7/2010

01.07.2010 | Knee

Can Patellar Tendon Angle reveal sagittal kinematics in total knee arthroplasty?

verfasst von: R. Stagni, S. Fantozzi, F. Catani, A. Leardini

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 7/2010

Einloggen, um Zugang zu erhalten

Abstract

The Patellar Tendon Angle is strongly correlated with both patello-femoral and tibio-femoral joint kinematics. Thus, the Patellar Tendon Angle might be regarded as a concise indicator of the antero-posterior translation of the femur with respect to the tibia. Twelve subjects, who had undergone total knee arthroplasty, were investigated by video-fluoroscopy during step-up/down. The kinematics at the replaced knee was reconstructed by means of 3D fluoroscopy. The Patellar Tendon Angle and the knee-flexion angle were measured on sagittal fluoroscopic images with software designed for the purpose. The slope of the linear trend of the Patellar Tendon Angle versus knee-flexion angle relationship correlated significantly with the mean (p = 0.001), most anterior (p = 0.001), and most posterior (p = 0.016) position reached by the femur over the tibia. The Patellar Tendon Angle versus knee-flexion angle relationship provides relevant information about the anterior or posterior positioning of the femur over the tibia, but it cannot be interpreted as quantification of the actual antero-posterior translation of the femur over the tibia.
Literatur
1.
Zurück zum Zitat Argenson JN, Komistek RD, Aubaniac JM, Dennis DA, Northcut EJ, Anderson DT, Agostini S (2002) In vivo determination of knee kinematics for subjects implanted with a unicompartmental arthroplasty. J Arthroplasty 17:1049–1054CrossRefPubMed Argenson JN, Komistek RD, Aubaniac JM, Dennis DA, Northcut EJ, Anderson DT, Agostini S (2002) In vivo determination of knee kinematics for subjects implanted with a unicompartmental arthroplasty. J Arthroplasty 17:1049–1054CrossRefPubMed
2.
Zurück zum Zitat Argenson JN, Scuderi GR, Komistek RD, Scott WN, Kelly MA, Aubaniac JM (2005) In vivo kinematic evaluation and design considerations related to high flexion in total knee arthroplasty. J Biomech 38:277–284CrossRefPubMed Argenson JN, Scuderi GR, Komistek RD, Scott WN, Kelly MA, Aubaniac JM (2005) In vivo kinematic evaluation and design considerations related to high flexion in total knee arthroplasty. J Biomech 38:277–284CrossRefPubMed
3.
Zurück zum Zitat Baltzopoulos V (1995) Muscular and tibiofemoral joint forces during isokinetic concentric knee extension. Clin Biomech (Bristol Avon) 10:208–214CrossRef Baltzopoulos V (1995) Muscular and tibiofemoral joint forces during isokinetic concentric knee extension. Clin Biomech (Bristol Avon) 10:208–214CrossRef
4.
Zurück zum Zitat Banks SA, Hodge WA (2004) Implant design affects knee arthroplasty kinematics during stair-stepping. Clin Orthop Relat Res 426:187–193CrossRefPubMed Banks SA, Hodge WA (2004) Implant design affects knee arthroplasty kinematics during stair-stepping. Clin Orthop Relat Res 426:187–193CrossRefPubMed
5.
Zurück zum Zitat Banks SA, Hodge WA (1996) Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy. IEEE Trans Biomed Eng 43:638–649CrossRefPubMed Banks SA, Hodge WA (1996) Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy. IEEE Trans Biomed Eng 43:638–649CrossRefPubMed
6.
Zurück zum Zitat Banks SA, Markovich GD, Hodge WA (1997) In vivo kinematics of cruciate-retaining and -substituting knee arthroplasties. J Arthroplasty 12:297–304CrossRefPubMed Banks SA, Markovich GD, Hodge WA (1997) In vivo kinematics of cruciate-retaining and -substituting knee arthroplasties. J Arthroplasty 12:297–304CrossRefPubMed
7.
Zurück zum Zitat Banks SA, Markovich GD, Hodge WA (1997) The mechanics of knee replacements during gait. In vivo fluoroscopic analysis of two designs. Am J Knee Surg 10:261–267PubMed Banks SA, Markovich GD, Hodge WA (1997) The mechanics of knee replacements during gait. In vivo fluoroscopic analysis of two designs. Am J Knee Surg 10:261–267PubMed
8.
Zurück zum Zitat Brage ME, Bennett CR, Whitehurst JB, Getty PJ, Toledano A (1997) Observer reliability in ankle radiographic measurements. Foot Ankle Int 18:324–329PubMed Brage ME, Bennett CR, Whitehurst JB, Getty PJ, Toledano A (1997) Observer reliability in ankle radiographic measurements. Foot Ankle Int 18:324–329PubMed
9.
Zurück zum Zitat Canny J (1986) A computational approach to edge detection. IEEE Trans Pattern Anal Mach Intell 8:679–698CrossRef Canny J (1986) A computational approach to edge detection. IEEE Trans Pattern Anal Mach Intell 8:679–698CrossRef
10.
Zurück zum Zitat Catani F, Fantozzi S, Ensini A, Leardini A, Moschella D, Giannini S (2006) Influence of tibial component posterior slope on in vivo knee kinematics in fixed-bearing total knee arthroplasty. J Orthop Res 24:581–587CrossRefPubMed Catani F, Fantozzi S, Ensini A, Leardini A, Moschella D, Giannini S (2006) Influence of tibial component posterior slope on in vivo knee kinematics in fixed-bearing total knee arthroplasty. J Orthop Res 24:581–587CrossRefPubMed
11.
Zurück zum Zitat DeFrate LE, Nha KW, Papannagari R, Moses JM, Gill TJ, Li G (2007) The biomechanical function of the patellar tendon during in vivo weight-bearing flexion. J Biomech 40:1716–1722CrossRefPubMed DeFrate LE, Nha KW, Papannagari R, Moses JM, Gill TJ, Li G (2007) The biomechanical function of the patellar tendon during in vivo weight-bearing flexion. J Biomech 40:1716–1722CrossRefPubMed
12.
Zurück zum Zitat Dennis DA, Komistek RD, Nadaud MC, Mahfouz M (2006) Evaluation of off-loading braces for treatment of unicompartmental knee arthrosis. J Arthroplasty 21:2–8CrossRefPubMed Dennis DA, Komistek RD, Nadaud MC, Mahfouz M (2006) Evaluation of off-loading braces for treatment of unicompartmental knee arthrosis. J Arthroplasty 21:2–8CrossRefPubMed
13.
Zurück zum Zitat Dennis DA, Komistek RD, Stiehl JB, Walker SA, Dennis KN (1998) Range of motion after total knee arthroplasty: the effect of implant design and weight-bearing conditions. J Arthroplasty 13:748–752CrossRefPubMed Dennis DA, Komistek RD, Stiehl JB, Walker SA, Dennis KN (1998) Range of motion after total knee arthroplasty: the effect of implant design and weight-bearing conditions. J Arthroplasty 13:748–752CrossRefPubMed
14.
Zurück zum Zitat Fantozzi S, Benedetti MG, Leardini A, Banks SA, Cappello A, Assirelli D, Catani F (2003) Fluoroscopic and gait analysis of the functional performance in stair ascent of two total knee replacement designs. Gait Posture 17:225–234PubMed Fantozzi S, Benedetti MG, Leardini A, Banks SA, Cappello A, Assirelli D, Catani F (2003) Fluoroscopic and gait analysis of the functional performance in stair ascent of two total knee replacement designs. Gait Posture 17:225–234PubMed
15.
Zurück zum Zitat Fantozzi S, Catani F, Ensini A, Leardini A, Giannini S (2006) Femoral rollback of cruciate-retaining and posterior-stabilized total knee replacements: in vivo fluoroscopic analysis during activities of daily living. J Orthop Res 24:2222–2229CrossRefPubMed Fantozzi S, Catani F, Ensini A, Leardini A, Giannini S (2006) Femoral rollback of cruciate-retaining and posterior-stabilized total knee replacements: in vivo fluoroscopic analysis during activities of daily living. J Orthop Res 24:2222–2229CrossRefPubMed
16.
Zurück zum Zitat Fantozzi S, Leardini A, Banks SA, Marcacci M, Giannini S, Catani F (2004) Dynamic in vivo tibio-femoral and bearing motions in mobile bearing knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 12:144–151CrossRefPubMed Fantozzi S, Leardini A, Banks SA, Marcacci M, Giannini S, Catani F (2004) Dynamic in vivo tibio-femoral and bearing motions in mobile bearing knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 12:144–151CrossRefPubMed
17.
Zurück zum Zitat Gill HS, O’Connor JJ (1996) Biarticulating two-dimensional computer model of the human patellofemoral joint. Clin Biomech (Bristol Avon) 11:81–89CrossRef Gill HS, O’Connor JJ (1996) Biarticulating two-dimensional computer model of the human patellofemoral joint. Clin Biomech (Bristol Avon) 11:81–89CrossRef
18.
Zurück zum Zitat Lee SY, Matsui N, Kurosaka M, Komistek RD, Mahfouz M, Dennis DA, Yoshiya S (2005) A posterior-stabilized total knee arthroplasty shows condylar lift-off during deep knee bends. Clin Orthop Relat Res 435:181–184CrossRefPubMed Lee SY, Matsui N, Kurosaka M, Komistek RD, Mahfouz M, Dennis DA, Yoshiya S (2005) A posterior-stabilized total knee arthroplasty shows condylar lift-off during deep knee bends. Clin Orthop Relat Res 435:181–184CrossRefPubMed
19.
Zurück zum Zitat Miller RK, Goodfellow JW, Murray DW, O’Connor JJ (1998) In vitro measurement of patellofemoral force after three types of knee replacement. J Bone Joint Surg Br 80:900–906CrossRefPubMed Miller RK, Goodfellow JW, Murray DW, O’Connor JJ (1998) In vitro measurement of patellofemoral force after three types of knee replacement. J Bone Joint Surg Br 80:900–906CrossRefPubMed
20.
Zurück zum Zitat Nisell R, Nemeth G, Ohlsen H (1986) Joint forces in extension of the knee. Analysis of a mechanical model. Acta Orthop Scand 57:41–46CrossRefPubMed Nisell R, Nemeth G, Ohlsen H (1986) Joint forces in extension of the knee. Analysis of a mechanical model. Acta Orthop Scand 57:41–46CrossRefPubMed
21.
Zurück zum Zitat Pandit H, Ward T, Hollinghurst D, Beard DJ, Gill HS, Thomas NP, Murray DW (2005) Influence of surface geometry and the cam-post mechanism on the kinematics of total knee replacement. J Bone Joint Surg Br 87:940–945CrossRefPubMed Pandit H, Ward T, Hollinghurst D, Beard DJ, Gill HS, Thomas NP, Murray DW (2005) Influence of surface geometry and the cam-post mechanism on the kinematics of total knee replacement. J Bone Joint Surg Br 87:940–945CrossRefPubMed
22.
Zurück zum Zitat Price AJ, Rees JL, Beard DJ, Gill RH, Dodd CA, Murray DM (2004) Sagittal plane kinematics of a mobile-bearing unicompartmental knee arthroplasty at 10 years: a comparative in vivo fluoroscopic analysis. J Arthroplasty 19:590–597CrossRefPubMed Price AJ, Rees JL, Beard DJ, Gill RH, Dodd CA, Murray DM (2004) Sagittal plane kinematics of a mobile-bearing unicompartmental knee arthroplasty at 10 years: a comparative in vivo fluoroscopic analysis. J Arthroplasty 19:590–597CrossRefPubMed
23.
Zurück zum Zitat Rees JL, Beard DJ, Price AJ, Gill HS, McLardy-Smith P, Dodd CA, Murray DW (2005) Real in vivo kinematic differences between mobile-bearing and fixed-bearing total knee arthroplasties. Clin Orthop Relat Res 432:204–209CrossRefPubMed Rees JL, Beard DJ, Price AJ, Gill HS, McLardy-Smith P, Dodd CA, Murray DW (2005) Real in vivo kinematic differences between mobile-bearing and fixed-bearing total knee arthroplasties. Clin Orthop Relat Res 432:204–209CrossRefPubMed
24.
Zurück zum Zitat Stagni R, Leardini A, Catani F, Cappello A (2004) A new semi-automated measurement technique based on X-ray pictures for ankle morphometry. J Biomech 37:1113–1118CrossRefPubMed Stagni R, Leardini A, Catani F, Cappello A (2004) A new semi-automated measurement technique based on X-ray pictures for ankle morphometry. J Biomech 37:1113–1118CrossRefPubMed
25.
Zurück zum Zitat Stiehl JB, Dennis DA, Komistek RD, Keblish PA (2000) In vivo kinematic comparison of posterior cruciate ligament retention or sacrifice with a mobile bearing total knee arthroplasty. Am J Knee Surg 13:13–18PubMed Stiehl JB, Dennis DA, Komistek RD, Keblish PA (2000) In vivo kinematic comparison of posterior cruciate ligament retention or sacrifice with a mobile bearing total knee arthroplasty. Am J Knee Surg 13:13–18PubMed
26.
Zurück zum Zitat Stiehl JB, Dennis DA, Komistek RD, Keblish PA (1997) In vivo kinematic analysis of a mobile bearing total knee prosthesis. Clin Orthop Relat Res 345:60–66CrossRefPubMed Stiehl JB, Dennis DA, Komistek RD, Keblish PA (1997) In vivo kinematic analysis of a mobile bearing total knee prosthesis. Clin Orthop Relat Res 345:60–66CrossRefPubMed
27.
Zurück zum Zitat Stiehl JB, Komistek RD, Dennis DA, Paxson RD, Hoff WA (1995) Fluoroscopic analysis of kinematics after posterior-cruciate-retaining knee arthroplasty. J Bone Joint Surg Br 77:884–889PubMed Stiehl JB, Komistek RD, Dennis DA, Paxson RD, Hoff WA (1995) Fluoroscopic analysis of kinematics after posterior-cruciate-retaining knee arthroplasty. J Bone Joint Surg Br 77:884–889PubMed
28.
Zurück zum Zitat van Eijden TM, de Boer W, Weijs WA (1985) The orientation of the distal part of the quadriceps femoris muscle as a function of the knee flexion-extension angle. J Biomech 18:803–809CrossRefPubMed van Eijden TM, de Boer W, Weijs WA (1985) The orientation of the distal part of the quadriceps femoris muscle as a function of the knee flexion-extension angle. J Biomech 18:803–809CrossRefPubMed
29.
Zurück zum Zitat Zuffi S, Leardini A, Catani F, Fantozzi S, Cappello A (1999) A model-based method for the reconstruction of total knee replacement kinematics. IEEE Trans Med Imaging 18:981–991CrossRefPubMed Zuffi S, Leardini A, Catani F, Fantozzi S, Cappello A (1999) A model-based method for the reconstruction of total knee replacement kinematics. IEEE Trans Med Imaging 18:981–991CrossRefPubMed
Metadaten
Titel
Can Patellar Tendon Angle reveal sagittal kinematics in total knee arthroplasty?
verfasst von
R. Stagni
S. Fantozzi
F. Catani
A. Leardini
Publikationsdatum
01.07.2010
Verlag
Springer-Verlag
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 7/2010
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-010-1075-7

Weitere Artikel der Ausgabe 7/2010

Knee Surgery, Sports Traumatology, Arthroscopy 7/2010 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.