Skip to main content
Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy 10/2010

01.10.2010 | Knee

Functional outcome after computer-assisted versus conventional total knee arthroplasty: a randomized controlled study

verfasst von: Jörg Lützner, Klaus-Peter Günther, Stephan Kirschner

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 10/2010

Einloggen, um Zugang zu erhalten

Abstract

Despite the frequent use of computer-assisted total knee arthroplasty (TKA) and better radiological results for coronal alignment reported in many studies, there is still no evidence of improved clinical outcomes when compared to conventional TKA. We compared alignment after navigated TKA and conventional TKA in 80 randomized patients. Seventy three patients were available for physical and radiological examination at 20 month after surgery. Both groups showed similar Knee Society Score results, with medians of 89 points (navigated 49–95 points, conventional 48–95 points, n.s.) in the Knee Score and 70 points (navigated 45–100 points, conventional 40–100 points, n.s.) in the Function Score. The median improvement in the Knee Society Knee Score was 45 points (−3 to 88 points) in the navigated group and 35 points (−13 to 62 points) in the conventional group (P = 0.03), and the Knee Society Function Score improvement was 15 points (−10 to 50 points) in the navigated group versus 10 points (−10 to 50 points) in the conventional group (n.s.). The current health state at follow-up using the EuroQuol questionnaire was similar in both groups, with medians of 67 points in the navigated group and 65 points in the conventional group. This investigation did show slightly greater functional improvement at short-term follow-up in the navigated TKA group. Longer follow-up will be required to assess the possible benefit of computer-assisted navigation.
Literatur
1.
Zurück zum Zitat Bauwens K, Matthes G, Wich M, Gebhard F, Hanson B, Ekkernkamp A, Stengel D (2007) Navigated total knee replacement. A meta-analysis. J Bone Joint Surg Am 89A:261–269CrossRef Bauwens K, Matthes G, Wich M, Gebhard F, Hanson B, Ekkernkamp A, Stengel D (2007) Navigated total knee replacement. A meta-analysis. J Bone Joint Surg Am 89A:261–269CrossRef
2.
Zurück zum Zitat Berend ME, Ritter MA, Meding JB, Faris PM, Keating EM, Redelman R, Faris GW, Davis KE (2004) Tibial component failure mechanisms in total knee arthroplasty. Clin Orthop Relat Res 428:26–34CrossRefPubMed Berend ME, Ritter MA, Meding JB, Faris PM, Keating EM, Redelman R, Faris GW, Davis KE (2004) Tibial component failure mechanisms in total knee arthroplasty. Clin Orthop Relat Res 428:26–34CrossRefPubMed
3.
Zurück zum Zitat Cerha O, Kirschner S, Gunther KP, Lützner J (2009) Cost analysis for navigation in knee endoprosthetics. Orthopäde 38:1235–1240CrossRefPubMed Cerha O, Kirschner S, Gunther KP, Lützner J (2009) Cost analysis for navigation in knee endoprosthetics. Orthopäde 38:1235–1240CrossRefPubMed
4.
Zurück zum Zitat Dattani R, Patnaik S, Kantak A, Tselentakis G (2009) Navigation knee replacement. Int Orthop 33:7–10CrossRefPubMed Dattani R, Patnaik S, Kantak A, Tselentakis G (2009) Navigation knee replacement. Int Orthop 33:7–10CrossRefPubMed
5.
Zurück zum Zitat DesJardins JD, Banks SA, Benson LC, Pace T, LaBerge M (2007) A direct comparison of patient and force-controlled simulator total knee replacement kinematics. J Biomech 40:3458–3466CrossRefPubMed DesJardins JD, Banks SA, Benson LC, Pace T, LaBerge M (2007) A direct comparison of patient and force-controlled simulator total knee replacement kinematics. J Biomech 40:3458–3466CrossRefPubMed
6.
Zurück zum Zitat Ewald FC (1989) The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res 248:9–12PubMed Ewald FC (1989) The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res 248:9–12PubMed
7.
Zurück zum Zitat Hakki S, Coleman S, Saleh K, Bilotta VJ, Hakki A (2009) Navigational predictors in determining the necessity for collateral ligament release in total knee replacement. J Bone Joint Surg Br 91B:1178–1182 Hakki S, Coleman S, Saleh K, Bilotta VJ, Hakki A (2009) Navigational predictors in determining the necessity for collateral ligament release in total knee replacement. J Bone Joint Surg Br 91B:1178–1182
9.
Zurück zum Zitat Insall JN, Dorr LD, Scott RD, Scott WN (1989) Rationale of the Knee Society clinical rating system. Clin Orthop Relat Res 248:13–14PubMed Insall JN, Dorr LD, Scott RD, Scott WN (1989) Rationale of the Knee Society clinical rating system. Clin Orthop Relat Res 248:13–14PubMed
10.
Zurück zum Zitat Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73B:709–714 Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73B:709–714
11.
Zurück zum Zitat Kamat YD, Aurakzai KM, Adhikari AR, Matthews D, Kalairajah Y, Field RE (2009) Does computer navigation in total knee arthroplasty improve patient outcome at midterm follow-up? Int Orthop 33:1567–1570CrossRefPubMed Kamat YD, Aurakzai KM, Adhikari AR, Matthews D, Kalairajah Y, Field RE (2009) Does computer navigation in total knee arthroplasty improve patient outcome at midterm follow-up? Int Orthop 33:1567–1570CrossRefPubMed
12.
Zurück zum Zitat Kim YH, Kim JS, Choi Y, Kwon OR (2009) Computer-assisted surgical navigation does not improve the alignment and orientation of the components in total knee arthroplasty. J Bone Joint Surg Am 91A:14–19CrossRef Kim YH, Kim JS, Choi Y, Kwon OR (2009) Computer-assisted surgical navigation does not improve the alignment and orientation of the components in total knee arthroplasty. J Bone Joint Surg Am 91A:14–19CrossRef
13.
Zurück zum Zitat Krackow KA, Pepe CL, Galloway EJ (1990) A mathematical analysis of the effect of flexion and rotation on apparent varus/valgus alignment at the knee. Orthopedics 13:861–868PubMed Krackow KA, Pepe CL, Galloway EJ (1990) A mathematical analysis of the effect of flexion and rotation on apparent varus/valgus alignment at the knee. Orthopedics 13:861–868PubMed
14.
Zurück zum Zitat Lee DH, Park JH, Song DI, Padhy D, Jeong WK, Han SB Accuracy of soft tissue balancing in TKA: comparison between navigation-assisted gap balancing and conventional measured resection. Knee Surg Sports Traumatol Arthrosc (Epub ahead of print). doi:10.1007/s00167-009-0983-x Lee DH, Park JH, Song DI, Padhy D, Jeong WK, Han SB Accuracy of soft tissue balancing in TKA: comparison between navigation-assisted gap balancing and conventional measured resection. Knee Surg Sports Traumatol Arthrosc (Epub ahead of print). doi:10.​1007/​s00167-009-0983-x
15.
Zurück zum Zitat Lotke PA, Ecker ML (1977) Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg Am 59:77–79PubMed Lotke PA, Ecker ML (1977) Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg Am 59:77–79PubMed
16.
Zurück zum Zitat Lützner J, Krummenauer F, Wolf C, Günther K-P, Kirschner S (2008) Computer-assisted and conventional total knee arthroplasty—a prospective, randomized study with radiographic and CT evaluations. J Bone Joint Surg Br 90B:1039–1044 Lützner J, Krummenauer F, Wolf C, Günther K-P, Kirschner S (2008) Computer-assisted and conventional total knee arthroplasty—a prospective, randomized study with radiographic and CT evaluations. J Bone Joint Surg Br 90B:1039–1044
17.
Zurück zum Zitat Molfetta L, Caldo D (2008) Computer navigation versus conventional implantation for varus knee total arthroplasty: a case-control study at 5 years follow-up. Knee 15:75–79CrossRefPubMed Molfetta L, Caldo D (2008) Computer navigation versus conventional implantation for varus knee total arthroplasty: a case-control study at 5 years follow-up. Knee 15:75–79CrossRefPubMed
18.
Zurück zum Zitat IH N (2004) NIH Consensus Statement on total knee replacement. J Bone and Joint Surg Am 86A:1328–1335 IH N (2004) NIH Consensus Statement on total knee replacement. J Bone and Joint Surg Am 86A:1328–1335
19.
Zurück zum Zitat Novak EJ, Silverstein MD, Bozic KJ (2007) The cost-effectiveness of computer-assisted navigation in total knee arthroplasty. J Bone Joint Surg Am 89A:2389–2397CrossRef Novak EJ, Silverstein MD, Bozic KJ (2007) The cost-effectiveness of computer-assisted navigation in total knee arthroplasty. J Bone Joint Surg Am 89A:2389–2397CrossRef
20.
Zurück zum Zitat Oberst M, Bertsch C, Wurstlin S, Holz U (2003) CT analysis of leg alignment after conventional vs. navigated knee prosthesis implantation. Initial results of a controlled, prospective and randomized study. Unfallchirurg 106:941–948PubMed Oberst M, Bertsch C, Wurstlin S, Holz U (2003) CT analysis of leg alignment after conventional vs. navigated knee prosthesis implantation. Initial results of a controlled, prospective and randomized study. Unfallchirurg 106:941–948PubMed
21.
Zurück zum Zitat Oppe M, Rabin R, de Charro F (2008) EQ-5D User Guide. www euroqol org Oppe M, Rabin R, de Charro F (2008) EQ-5D User Guide. www euroqol org
22.
Zurück zum Zitat Rasanen P, Paavolainen P, Sintonen H, Koivisto AM, Blom M, Ryynanen OP, Roine RP (2007) Effectiveness of hip or knee replacement surgery in terms of quality-adjusted life years and costs. Acta Orthop 78:108–115CrossRefPubMed Rasanen P, Paavolainen P, Sintonen H, Koivisto AM, Blom M, Ryynanen OP, Roine RP (2007) Effectiveness of hip or knee replacement surgery in terms of quality-adjusted life years and costs. Acta Orthop 78:108–115CrossRefPubMed
23.
Zurück zum Zitat Rhoads DD, Noble PC, Reuben JD, Tullos HS (1993) The effect of femoral component position on the kinematics of total knee arthroplasty. Clin Orthop Relat Res 286:122–129PubMed Rhoads DD, Noble PC, Reuben JD, Tullos HS (1993) The effect of femoral component position on the kinematics of total knee arthroplasty. Clin Orthop Relat Res 286:122–129PubMed
24.
Zurück zum Zitat Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop Relat Res 299:153–156PubMed Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop Relat Res 299:153–156PubMed
25.
Zurück zum Zitat Slover JD, Tosteson AN, Bozic KJ, Rubash HE, Malchau H (2008) Impact of hospital volume on the economic value of computer navigation for total knee replacement. J Bone Joint Surg Am 90A:1492–1500CrossRef Slover JD, Tosteson AN, Bozic KJ, Rubash HE, Malchau H (2008) Impact of hospital volume on the economic value of computer navigation for total knee replacement. J Bone Joint Surg Am 90A:1492–1500CrossRef
26.
Zurück zum Zitat Spencer JM, Chauhan SK, Sloan K, Taylor A, Beaver RJ (2007) Computer navigation versus conventional total knee replacement: no difference in functional results at two years. J Bone Joint Surg Br 89:477–480CrossRefPubMed Spencer JM, Chauhan SK, Sloan K, Taylor A, Beaver RJ (2007) Computer navigation versus conventional total knee replacement: no difference in functional results at two years. J Bone Joint Surg Br 89:477–480CrossRefPubMed
27.
Zurück zum Zitat Yaffe MA, Koo SS, Stulberg SD (2008) Radiographic and navigation measurements of TKA limb alignment do not correlate. Clin Orthop Relat Res 466:2736–2744CrossRefPubMed Yaffe MA, Koo SS, Stulberg SD (2008) Radiographic and navigation measurements of TKA limb alignment do not correlate. Clin Orthop Relat Res 466:2736–2744CrossRefPubMed
Metadaten
Titel
Functional outcome after computer-assisted versus conventional total knee arthroplasty: a randomized controlled study
verfasst von
Jörg Lützner
Klaus-Peter Günther
Stephan Kirschner
Publikationsdatum
01.10.2010
Verlag
Springer-Verlag
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 10/2010
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-010-1153-x

Weitere Artikel der Ausgabe 10/2010

Knee Surgery, Sports Traumatology, Arthroscopy 10/2010 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.