Skip to main content
Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy 3/2013

01.03.2013 | Knee

No allergic reaction after TKA in a chrome-cobalt-nickel-sensitive patient: case report and review of the literature

verfasst von: Emmanuel Thienpont, Yorick Berger

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 3/2013

Einloggen, um Zugang zu erhalten

Abstract

Hypersensitivity to metallic implants remains relatively unpredictable and poorly understood. Although 20–25 % of total joint arthroplasty patients develop metal sensitivity, only a few highly susceptible persons (<1 %) exhibit symptoms. We present a case report of a fifty-two-year-old woman with a preoperatively documented metal allergy who underwent bilateral total knee arthroplasty using a titanium-niobium-coated implant on one side and a chrome-cobalt implant on the other side because of a logistics problem. At 2-year follow-up, no clinical symptoms of allergy or loosening of the implant were observed. Level of evidence IV.
Literatur
1.
Zurück zum Zitat Anand A, McGlynn F, Jiranek W (2009) Metal hypersensitivity: can it mimic infection? J Arthroplasty 24(826):e25–e28PubMed Anand A, McGlynn F, Jiranek W (2009) Metal hypersensitivity: can it mimic infection? J Arthroplasty 24(826):e25–e28PubMed
2.
Zurück zum Zitat Basketter DA, Briatico-Vangosa G, Kaestner W, Lally C, Bontinck WJ (1993) Nickel, cobalt and chromium in consumer products: a role in allergic contact dermatitis? Contact Dermat 28:15–25CrossRef Basketter DA, Briatico-Vangosa G, Kaestner W, Lally C, Bontinck WJ (1993) Nickel, cobalt and chromium in consumer products: a role in allergic contact dermatitis? Contact Dermat 28:15–25CrossRef
3.
Zurück zum Zitat Basko-Plluska JL, Thyssen JP, Schalock PC (2011) Cutaneous and systemic hypersensitivity reactions to metallic implants. Dermatitis 22:65–79PubMed Basko-Plluska JL, Thyssen JP, Schalock PC (2011) Cutaneous and systemic hypersensitivity reactions to metallic implants. Dermatitis 22:65–79PubMed
4.
Zurück zum Zitat Beecker J, Gordon J, Pratt M (2009) An interesting case of joint prosthesis allergy. Dermatitis 20:4–9 Beecker J, Gordon J, Pratt M (2009) An interesting case of joint prosthesis allergy. Dermatitis 20:4–9
5.
Zurück zum Zitat Bergschmidt P, Bader R, Mittelmeier W (2012) Metal hypersensitivity in total knee arthroplasty: revision surgery using a ceramic femoral component: a case report. Knee 19:144–147PubMedCrossRef Bergschmidt P, Bader R, Mittelmeier W (2012) Metal hypersensitivity in total knee arthroplasty: revision surgery using a ceramic femoral component: a case report. Knee 19:144–147PubMedCrossRef
6.
Zurück zum Zitat Caicedo MS, Desai R, McAllister K, Reddy A, Jacobs JJ, Hallab NJ (2009) Soluble and particulate Co-Cr-Mo alloy implant metals activate the inflammasone danger signaling pathway in human macrophages: a novel mechanism for implant debris reactivity. J Orthop Res 27:847–854PubMedCrossRef Caicedo MS, Desai R, McAllister K, Reddy A, Jacobs JJ, Hallab NJ (2009) Soluble and particulate Co-Cr-Mo alloy implant metals activate the inflammasone danger signaling pathway in human macrophages: a novel mechanism for implant debris reactivity. J Orthop Res 27:847–854PubMedCrossRef
7.
Zurück zum Zitat Cousen PJ, Gawkrodger DJ (2012) Metal allergy and second-generation metal-on-metal arthroplasties. Contact Dermat 66:55–62CrossRef Cousen PJ, Gawkrodger DJ (2012) Metal allergy and second-generation metal-on-metal arthroplasties. Contact Dermat 66:55–62CrossRef
8.
Zurück zum Zitat Frigerio E, Pigatto PD, Guzzi G, Altomare G (2011) Metal sensitivity in patients with orthopedic implants: a prospective study. Contact Dermat 64:273–279CrossRef Frigerio E, Pigatto PD, Guzzi G, Altomare G (2011) Metal sensitivity in patients with orthopedic implants: a prospective study. Contact Dermat 64:273–279CrossRef
9.
Zurück zum Zitat Gao X, Rx He, Yan SG, Wu LD (2011) Dermatitis associated with chromium following total knee arthroplasty. J Arthroplasty 26(665):e13–e16PubMed Gao X, Rx He, Yan SG, Wu LD (2011) Dermatitis associated with chromium following total knee arthroplasty. J Arthroplasty 26(665):e13–e16PubMed
10.
Zurück zum Zitat Granchi D, Cenni E, Tigani D, Trisolino G, Baldini N, Giunti A (2008) Sensitivity to implant materials in patients with total knee arthroplasties. Biomaterials 29:1494–1500PubMedCrossRef Granchi D, Cenni E, Tigani D, Trisolino G, Baldini N, Giunti A (2008) Sensitivity to implant materials in patients with total knee arthroplasties. Biomaterials 29:1494–1500PubMedCrossRef
11.
Zurück zum Zitat Hallab N, Merritt K, Jacobs JJ (2001) Metal sensitivity in patients with orthopaedic implants. J Bone Joint Surg Am 83:428–436PubMedCrossRef Hallab N, Merritt K, Jacobs JJ (2001) Metal sensitivity in patients with orthopaedic implants. J Bone Joint Surg Am 83:428–436PubMedCrossRef
12.
Zurück zum Zitat Hallab NJ, Caicedo M, Epstein R, McAllister K, Jacobs JJ (2010) In vitro reactivity to implant metals demonstrates a person-dependant association with both T-cell and B-cell activation. J Biomed Mat Res 92(2):667–682 Hallab NJ, Caicedo M, Epstein R, McAllister K, Jacobs JJ (2010) In vitro reactivity to implant metals demonstrates a person-dependant association with both T-cell and B-cell activation. J Biomed Mat Res 92(2):667–682
13.
Zurück zum Zitat Handa S, Dogra S, Prasad R (2003) Metal sensitivity in a patient with a total knee replacement. Contact Dermat 49:259–260CrossRef Handa S, Dogra S, Prasad R (2003) Metal sensitivity in a patient with a total knee replacement. Contact Dermat 49:259–260CrossRef
14.
Zurück zum Zitat Harloff T, Hönle W, Holzwarth U, Bader R, Thomas P, Schuh A (2010) Titanium allergy or not? “Impurity” of titanium implants. Materials 2:306–310 Harloff T, Hönle W, Holzwarth U, Bader R, Thomas P, Schuh A (2010) Titanium allergy or not? “Impurity” of titanium implants. Materials 2:306–310
15.
Zurück zum Zitat Jacobs JJ, Hallab NJ (2006) Loosening and osteolysis associated with metal-on-metal bearings: a local effect of metal hypersensitivity? J Bone Joint Surg Am 88:1171–1172PubMedCrossRef Jacobs JJ, Hallab NJ (2006) Loosening and osteolysis associated with metal-on-metal bearings: a local effect of metal hypersensitivity? J Bone Joint Surg Am 88:1171–1172PubMedCrossRef
16.
Zurück zum Zitat Merritt K, Rodrigo JJ (1996) Immune response to synthetic materials. Sensitization of patients receiving orthopaedic implants. Clin Orthop Relat Res 326:71–79PubMedCrossRef Merritt K, Rodrigo JJ (1996) Immune response to synthetic materials. Sensitization of patients receiving orthopaedic implants. Clin Orthop Relat Res 326:71–79PubMedCrossRef
17.
Zurück zum Zitat Niki Y, Matsumoto H, Otani T, Yatabe T, Kondo M, Yoshimine F, Toyama Y (2005) Screening for symptomatic metal sensitivity: a prospective study of 92 patients undergoing total knee arthroplasty. Biomaterials 26:1019–1026PubMedCrossRef Niki Y, Matsumoto H, Otani T, Yatabe T, Kondo M, Yoshimine F, Toyama Y (2005) Screening for symptomatic metal sensitivity: a prospective study of 92 patients undergoing total knee arthroplasty. Biomaterials 26:1019–1026PubMedCrossRef
18.
Zurück zum Zitat Perumal V, Alkire M, Swank ML (2010) Unusual presentation of cobalt hypersensitivity in a patient with a metal on metal arthroplasty. Am J Ortoped 39:e39–e41 Perumal V, Alkire M, Swank ML (2010) Unusual presentation of cobalt hypersensitivity in a patient with a metal on metal arthroplasty. Am J Ortoped 39:e39–e41
19.
Zurück zum Zitat Schalock PC, Menné T, Johansen JD, Taylor JS, Malbach HI, Lidén C, Bruze M, Thyssen JP (2012) Hypersensitivity reactions to metallic implants-diagnostic algorithm and suggested patch test series for clinical use. Contact Dermat 66:4–19CrossRef Schalock PC, Menné T, Johansen JD, Taylor JS, Malbach HI, Lidén C, Bruze M, Thyssen JP (2012) Hypersensitivity reactions to metallic implants-diagnostic algorithm and suggested patch test series for clinical use. Contact Dermat 66:4–19CrossRef
20.
Zurück zum Zitat Summer B, Paul C, Mazoochian F, Rau C, Thomsen M, Banke I, Gollwitzer H, Dietrich KA, Mayer-Wagner S, Ruzicka T, Thomas P (2010) Nickel (Ni) allergic patients with complications to Ni containing joint replacement show preferential IL-17 type reactivity to Ni. Contact Dermat 63:15–22CrossRef Summer B, Paul C, Mazoochian F, Rau C, Thomsen M, Banke I, Gollwitzer H, Dietrich KA, Mayer-Wagner S, Ruzicka T, Thomas P (2010) Nickel (Ni) allergic patients with complications to Ni containing joint replacement show preferential IL-17 type reactivity to Ni. Contact Dermat 63:15–22CrossRef
21.
Zurück zum Zitat Thomas P, Thomas M, Summer B, Dietrich K, Zauzig M, Steinhauser E, Krenn V, Arnholdt H, Flaig M (2011) Impaired wound-healing, local eczema, and chronic inflammation following titanium osteosynthesis in a nickel and cobalt-allergic patient. A case report and review of the literature. J Bone Joint Surg Am 93:e61 Thomas P, Thomas M, Summer B, Dietrich K, Zauzig M, Steinhauser E, Krenn V, Arnholdt H, Flaig M (2011) Impaired wound-healing, local eczema, and chronic inflammation following titanium osteosynthesis in a nickel and cobalt-allergic patient. A case report and review of the literature. J Bone Joint Surg Am 93:e61
22.
Zurück zum Zitat Thomsen M, Rozak M, Thomas P (2011) Pain in a chromium-allergic patient with total knee arthroplasty: disappearance of symptoms after revision with a special surface-coated TKA- A case report. Acta Orthop 82:386–388PubMedCrossRef Thomsen M, Rozak M, Thomas P (2011) Pain in a chromium-allergic patient with total knee arthroplasty: disappearance of symptoms after revision with a special surface-coated TKA- A case report. Acta Orthop 82:386–388PubMedCrossRef
23.
Zurück zum Zitat Thyssen JP, Jakobsen SS, Engkilde K, Johansen JD, Soballe K, Menne T (2009) The association between metal allergy, total hip arthroplasty, and revision. Acta Orthop 80:646–652PubMedCrossRef Thyssen JP, Jakobsen SS, Engkilde K, Johansen JD, Soballe K, Menne T (2009) The association between metal allergy, total hip arthroplasty, and revision. Acta Orthop 80:646–652PubMedCrossRef
24.
Zurück zum Zitat Thyssen JP, Menné T, Schalock PC, Taylor JS, Maibach HI (2011) Pragmatic approach to the clinical work-up of patients with putative allergic disease to metallic orthopaedic implants before and after surgery. Br J Dermatol 164:473–478PubMed Thyssen JP, Menné T, Schalock PC, Taylor JS, Maibach HI (2011) Pragmatic approach to the clinical work-up of patients with putative allergic disease to metallic orthopaedic implants before and after surgery. Br J Dermatol 164:473–478PubMed
25.
Zurück zum Zitat Verma SB, Mody B, Gawkrodger DJ (2006) Dermatitis on the knee following knee replacement: a minority of cases show contact allergy to chromate, cobalt or nickel but a causal association is unproven. Contact Dermat 54:228–229CrossRef Verma SB, Mody B, Gawkrodger DJ (2006) Dermatitis on the knee following knee replacement: a minority of cases show contact allergy to chromate, cobalt or nickel but a causal association is unproven. Contact Dermat 54:228–229CrossRef
Metadaten
Titel
No allergic reaction after TKA in a chrome-cobalt-nickel-sensitive patient: case report and review of the literature
verfasst von
Emmanuel Thienpont
Yorick Berger
Publikationsdatum
01.03.2013
Verlag
Springer-Verlag
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 3/2013
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-012-2000-z

Weitere Artikel der Ausgabe 3/2013

Knee Surgery, Sports Traumatology, Arthroscopy 3/2013 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie