Skip to main content
Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy 12/2013

01.12.2013 | Knee

Single-radius, multidirectional total knee replacement

verfasst von: Jean-Yves Jenny, Rolf Miehlke, Dominique Saragaglia, Robert Geyer, Numa Mercier, Jean-Yves Schoenahl, Birger Thiel

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 12/2013

Einloggen, um Zugang zu erhalten

Abstract

Purpose

The present study was designed to evaluate the mid-term (5- to 8-year) survival rate of a new total knee replacement (TKR) with a single-radius femoral component and a multidirectional, highly congruent tibial component, in comparison with an historical group (TKR with multi-radius design and fixed bearing).

Methods

Four hundred and thirty patients were included, of which 369 patients (86 %) completed the 5-year follow-up with Knee Society Score evaluation and radiograph examination (study group = 387, control group = 83).

Results

There was a significant improvement for all analysed items between pre-operative status and late follow-up. Mean knee score was 93 ± 9 points in the study group and 88 ± 16 points in the control group (p < 0.001). Mean flexion angle was not different (118 ± 11 vs. 114 ± 13 degrees). Mean functional score was 87 ± 16 points in the study group and 71 ± 24 points in the control group (p < 0.001). Survival rate at 5-year follow-up was 98.8 % (vs. 98.0 %) for mechanical revisions only, and 96.4 % (vs. 98.1 %) for all revisions.

Conclusions

The new TKR allowed obtaining significantly better results than the fixed-bearing TKR. These results are in line with the best series published in the current literature, but there was no evidence of any superiority of this TKR against already published standards.

Level of evidence

Case series with comparison group, Level III.
Literatur
1.
Zurück zum Zitat Aglietti P, Baldini A, Buzzi R, Lup D, De Luca L (2005) Comparison of mobile-bearing and fixed-bearing total knee arthroplasty: a prospective randomized study. J Arthroplasty 20:145–153PubMedCrossRef Aglietti P, Baldini A, Buzzi R, Lup D, De Luca L (2005) Comparison of mobile-bearing and fixed-bearing total knee arthroplasty: a prospective randomized study. J Arthroplasty 20:145–153PubMedCrossRef
2.
Zurück zum Zitat Ahlback S (1968) Osteoarthrosis of the knee. A radiographic investigation. Acta Radiol Diagn (Suppl 277):1–72 Ahlback S (1968) Osteoarthrosis of the knee. A radiographic investigation. Acta Radiol Diagn (Suppl 277):1–72
3.
Zurück zum Zitat Baldini A, Anderson JA, Zampetti P, Pavlov H, Sculco TP (2006) A new patellofemoral scoring system for total knee arthroplasty. Clin Orthop Relat Res 452:150–154PubMedCrossRef Baldini A, Anderson JA, Zampetti P, Pavlov H, Sculco TP (2006) A new patellofemoral scoring system for total knee arthroplasty. Clin Orthop Relat Res 452:150–154PubMedCrossRef
4.
Zurück zum Zitat Borrione F, Bonnevialle P, Mabit C, Guingand O, Bertin D, Bonnomet F, Denis C, Gagna G (2011) Scorpio single radius total knee arthroplasty. A minimal five-year follow-up multicentric study. Int Orthop 35:1777–1782PubMedCrossRef Borrione F, Bonnevialle P, Mabit C, Guingand O, Bertin D, Bonnomet F, Denis C, Gagna G (2011) Scorpio single radius total knee arthroplasty. A minimal five-year follow-up multicentric study. Int Orthop 35:1777–1782PubMedCrossRef
5.
Zurück zum Zitat Bozic KJ, Kurtz SM, Lau E, Ong K, Chiu V, Vail TP, Rubash HE, Berry DJ (2011) The epidemiology of revision total knee arthroplasty in the United States. Clin Orthop Relat Res 468:45–51CrossRef Bozic KJ, Kurtz SM, Lau E, Ong K, Chiu V, Vail TP, Rubash HE, Berry DJ (2011) The epidemiology of revision total knee arthroplasty in the United States. Clin Orthop Relat Res 468:45–51CrossRef
6.
Zurück zum Zitat Buechel FF Sr, Buechel FF Jr, Pappas MJ, Dalessio J (2002) Twenty-year evaluation of the New Jersey LCS rotating platform knee replacement. J Knee Surg 15:84–89PubMed Buechel FF Sr, Buechel FF Jr, Pappas MJ, Dalessio J (2002) Twenty-year evaluation of the New Jersey LCS rotating platform knee replacement. J Knee Surg 15:84–89PubMed
7.
Zurück zum Zitat Carothers JT, Kim RH, Dennis DA, Southworth C (2010) Mobile-bearing total knee arthroplasty. A meta-analysis. J Arthroplasty 26:537–542PubMedCrossRef Carothers JT, Kim RH, Dennis DA, Southworth C (2010) Mobile-bearing total knee arthroplasty. A meta-analysis. J Arthroplasty 26:537–542PubMedCrossRef
8.
Zurück zum Zitat Chang CW, Lai KA, Yang CY, Lan SM (2011) Early mechanical complications of a multidirectional mobile-bearing total knee replacement. J Bone Joint Surg Br 93:479–483PubMed Chang CW, Lai KA, Yang CY, Lan SM (2011) Early mechanical complications of a multidirectional mobile-bearing total knee replacement. J Bone Joint Surg Br 93:479–483PubMed
9.
Zurück zum Zitat Chiu KY, Ng TP, Tang WM, Yau WP (2002) Review article: knee flexion after total knee arthroplasty. J Orthop Surg (Hong Kong) 10:194–202 Chiu KY, Ng TP, Tang WM, Yau WP (2002) Review article: knee flexion after total knee arthroplasty. J Orthop Surg (Hong Kong) 10:194–202
10.
Zurück zum Zitat Chouteau J, Lerat JL, Testa R, Moyen B, Fessy MH, Banks SA (2009) Mobile-bearing insert translational and rotational kinematics in a PCL-retaining total knee arthroplasty. Orthop Traumatol Surg Res 95:254–259PubMedCrossRef Chouteau J, Lerat JL, Testa R, Moyen B, Fessy MH, Banks SA (2009) Mobile-bearing insert translational and rotational kinematics in a PCL-retaining total knee arthroplasty. Orthop Traumatol Surg Res 95:254–259PubMedCrossRef
11.
Zurück zum Zitat Colwell CW Jr, Chen PC, D’Lima D (2011) Extensor malalignment arising from femoral component malrotation in knee arthroplasty: effect of rotating-bearing. Clin Biomech 26:52–57CrossRef Colwell CW Jr, Chen PC, D’Lima D (2011) Extensor malalignment arising from femoral component malrotation in knee arthroplasty: effect of rotating-bearing. Clin Biomech 26:52–57CrossRef
12.
Zurück zum Zitat Forster MC (2003) Survival analysis of primary cemented total knee arthroplasty: which designs last? J Arthroplasty 18:265–270PubMedCrossRef Forster MC (2003) Survival analysis of primary cemented total knee arthroplasty: which designs last? J Arthroplasty 18:265–270PubMedCrossRef
13.
Zurück zum Zitat Geiger F, Mau H, Krueger M, Thomsen M (2008) Comparison of a new mobile bearing total knee prosthesis with a fixed bearing prosthesis: a matched pair analysis. Arch Orthop Trauma Surg 128:285–291PubMedCrossRef Geiger F, Mau H, Krueger M, Thomsen M (2008) Comparison of a new mobile bearing total knee prosthesis with a fixed bearing prosthesis: a matched pair analysis. Arch Orthop Trauma Surg 128:285–291PubMedCrossRef
14.
Zurück zum Zitat Grupp TM, Miehlke RK, Hintner M, Schwiesau J, Kaddick C (2011) In vitro knee wear, kinematics and particle morphology among different bearing geometries in a mobile bearing knee system. ASTM JAI 8:1–10 Grupp TM, Miehlke RK, Hintner M, Schwiesau J, Kaddick C (2011) In vitro knee wear, kinematics and particle morphology among different bearing geometries in a mobile bearing knee system. ASTM JAI 8:1–10
15.
Zurück zum Zitat Hollister AM, Jatana S, Singh AK, Sullivan WW, Lupichuk AG (1993) The axes of rotation of the knee. Clin Orthop Relat Res 290:259–268PubMed Hollister AM, Jatana S, Singh AK, Sullivan WW, Lupichuk AG (1993) The axes of rotation of the knee. Clin Orthop Relat Res 290:259–268PubMed
16.
Zurück zum Zitat Hudd A, Kunasingam K, Ricketts D, Bush J (2009) A 5 to 8 year follow-up study of the Rotaglide mobile bearing total knee arthroplasty. Int Orthop 33:675–678PubMedCrossRef Hudd A, Kunasingam K, Ricketts D, Bush J (2009) A 5 to 8 year follow-up study of the Rotaglide mobile bearing total knee arthroplasty. Int Orthop 33:675–678PubMedCrossRef
17.
Zurück zum Zitat Insall JN, Dorr LD, Scott RD, Scott WN (1989) Rationale of the knee society clinical rating system. Clin Orthop Relat Res 248:13–14PubMed Insall JN, Dorr LD, Scott RD, Scott WN (1989) Rationale of the knee society clinical rating system. Clin Orthop Relat Res 248:13–14PubMed
18.
Zurück zum Zitat Ishida K, Matsumoto T, Tsumura N, Kubo S, Kitagawa A, Chin T, Iguchi T, Kurosaka M, Kuroda R (2011) Mid-term outcomes of computer-assisted total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 19:1107–1112PubMedCrossRef Ishida K, Matsumoto T, Tsumura N, Kubo S, Kitagawa A, Chin T, Iguchi T, Kurosaka M, Kuroda R (2011) Mid-term outcomes of computer-assisted total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 19:1107–1112PubMedCrossRef
19.
Zurück zum Zitat Jenny JY, Jenny G (1998) Preservation of anterior cruciate ligament in total knee arthroplasty. Arch Orthop Trauma Surg 118:145–148PubMedCrossRef Jenny JY, Jenny G (1998) Preservation of anterior cruciate ligament in total knee arthroplasty. Arch Orthop Trauma Surg 118:145–148PubMedCrossRef
20.
Zurück zum Zitat Jenny JY, Boeri C (2001) Computer-assisted implantation of total knee prostheses: a case-control comparative study with classical instrumentation. Comput Aided Surg 6:217–220PubMedCrossRef Jenny JY, Boeri C (2001) Computer-assisted implantation of total knee prostheses: a case-control comparative study with classical instrumentation. Comput Aided Surg 6:217–220PubMedCrossRef
21.
Zurück zum Zitat Jenny JY, Clemens U, Kohler S, Kiefer H, Konermann W, Miehlke RK (2005) Consistency of implantation of a total knee arthroplasty with a non-image-based navigation system: a case-control study of 235 cases compared with 235 conventionally implanted prostheses. J Arthroplasty 20:832–839PubMedCrossRef Jenny JY, Clemens U, Kohler S, Kiefer H, Konermann W, Miehlke RK (2005) Consistency of implantation of a total knee arthroplasty with a non-image-based navigation system: a case-control study of 235 cases compared with 235 conventionally implanted prostheses. J Arthroplasty 20:832–839PubMedCrossRef
22.
Zurück zum Zitat Jenny JY, Miehlke RK, Giurea A (2008) Learning curve in navigated total knee replacement. A multi-centre study comparing experienced and beginner centres. Knee 15:80–84PubMedCrossRef Jenny JY, Miehlke RK, Giurea A (2008) Learning curve in navigated total knee replacement. A multi-centre study comparing experienced and beginner centres. Knee 15:80–84PubMedCrossRef
23.
Zurück zum Zitat Jones VC, Barton DC, Fitzpatrick DP, Auger DD, Stone MH, Fisher J (1999) An experimental model of tibial counter face polyethylene wear in mobile bearing knees: the influence of design and kinematics. Biomed Mater Eng 9:189–196PubMed Jones VC, Barton DC, Fitzpatrick DP, Auger DD, Stone MH, Fisher J (1999) An experimental model of tibial counter face polyethylene wear in mobile bearing knees: the influence of design and kinematics. Biomed Mater Eng 9:189–196PubMed
24.
Zurück zum Zitat Kim TK, Chang CB, Kang YG, Chung BJ, Cho HJ, Seong SC (2010) Early clinical outcomes of floating platform mobile-bearing TKA: longitudinal comparison with fixed-bearing TKA. Knee Surg Sports Traumatol Arthrosc 18:879–888PubMedCrossRef Kim TK, Chang CB, Kang YG, Chung BJ, Cho HJ, Seong SC (2010) Early clinical outcomes of floating platform mobile-bearing TKA: longitudinal comparison with fixed-bearing TKA. Knee Surg Sports Traumatol Arthrosc 18:879–888PubMedCrossRef
25.
Zurück zum Zitat Kim YH, Kim JS, Choi Y (2009) Osteolysis after unidirectional and multidirectional mobile-bearing total knee arthroplasty in young patients. J Arthroplasty 24:586–593PubMedCrossRef Kim YH, Kim JS, Choi Y (2009) Osteolysis after unidirectional and multidirectional mobile-bearing total knee arthroplasty in young patients. J Arthroplasty 24:586–593PubMedCrossRef
26.
Zurück zum Zitat Lemaire RG (2010) Mid-term results with a highly congruous mobile-bearing knee prosthesis. Knee Surg Sports Traumatol Arthrosc 18:170–180PubMedCrossRef Lemaire RG (2010) Mid-term results with a highly congruous mobile-bearing knee prosthesis. Knee Surg Sports Traumatol Arthrosc 18:170–180PubMedCrossRef
27.
Zurück zum Zitat Li S, Chen Y, Su W, Zhao J, He S, Luo X (2010) Systematic review of patellar resurfacing in total knee arthroplasty. Int Orthop 35:305–316PubMedCrossRef Li S, Chen Y, Su W, Zhao J, He S, Luo X (2010) Systematic review of patellar resurfacing in total knee arthroplasty. Int Orthop 35:305–316PubMedCrossRef
28.
Zurück zum Zitat Massin P, Heizmann J, Prove S, Dupuy FR, Ponthieux A (2008) Accuracy and reproducibility of computer-assisted measurement of polyethylene wear in knee arthroplasty. Acta Orthop Belg 74:72–82PubMed Massin P, Heizmann J, Prove S, Dupuy FR, Ponthieux A (2008) Accuracy and reproducibility of computer-assisted measurement of polyethylene wear in knee arthroplasty. Acta Orthop Belg 74:72–82PubMed
29.
Zurück zum Zitat Metsovitis SR, Ploumis AL, Chantzidis PT, Terzidis IP, Christodoulou AG, Dimitriou CG, Tsakonas AC (2011) Rotaglide total knee arthroplasty: a long-term follow-up study. J Bone Joint Surg Am 93:878–884PubMedCrossRef Metsovitis SR, Ploumis AL, Chantzidis PT, Terzidis IP, Christodoulou AG, Dimitriou CG, Tsakonas AC (2011) Rotaglide total knee arthroplasty: a long-term follow-up study. J Bone Joint Surg Am 93:878–884PubMedCrossRef
30.
Zurück zum Zitat Morra EA, Greenwald SE (2005) Polymer insert stress in total knee designs during high-flexion activities: a finite element study. J Bone Joint Surg Am 87(Suppl 2):120–124PubMedCrossRef Morra EA, Greenwald SE (2005) Polymer insert stress in total knee designs during high-flexion activities: a finite element study. J Bone Joint Surg Am 87(Suppl 2):120–124PubMedCrossRef
31.
Zurück zum Zitat Narayan K, Thomas G, Kumar R (2009) Is extreme flexion of the knee after total knee replacement a prerequisite for patient satisfaction? Int Orthop 33:671–674PubMedCrossRef Narayan K, Thomas G, Kumar R (2009) Is extreme flexion of the knee after total knee replacement a prerequisite for patient satisfaction? Int Orthop 33:671–674PubMedCrossRef
32.
Zurück zum Zitat Russo A, Bragonzoni L, Trozzi C, Iacono F, Visani A, Marcacci M (2008) Radiostereometric measurement of polyethylene deformation pattern in meniscal bearing TKR at 5 years follow-up. Knee Surg Sports Traumatol Arthrosc 16:142–147PubMedCrossRef Russo A, Bragonzoni L, Trozzi C, Iacono F, Visani A, Marcacci M (2008) Radiostereometric measurement of polyethylene deformation pattern in meniscal bearing TKR at 5 years follow-up. Knee Surg Sports Traumatol Arthrosc 16:142–147PubMedCrossRef
33.
Zurück zum Zitat Seon JK, Song EK, Yoon TR, Park SJ, Bae BH, Cho SG (2007) Comparison of functional results with navigation-assisted minimally invasive and conventional techniques in bilateral total knee arthroplasty. Comput Aided Surg 12:189–193PubMed Seon JK, Song EK, Yoon TR, Park SJ, Bae BH, Cho SG (2007) Comparison of functional results with navigation-assisted minimally invasive and conventional techniques in bilateral total knee arthroplasty. Comput Aided Surg 12:189–193PubMed
34.
Zurück zum Zitat Seon JK, Song EK, Park SJ, Lee DS (2010) The use of navigation to obtain rectangular flexion and extension gaps during primary total knee arthroplasty and midterm clinical results. J Arthroplasty 26:582–590PubMedCrossRef Seon JK, Song EK, Park SJ, Lee DS (2010) The use of navigation to obtain rectangular flexion and extension gaps during primary total knee arthroplasty and midterm clinical results. J Arthroplasty 26:582–590PubMedCrossRef
35.
Zurück zum Zitat Siu D, Cooke TD, Broekhiven LD, Lam M, Fisher B, Saunders G, Challis TW (1991) A standardized technique for lower limb radiography. Practice, applications, and error analysis. Invest Radiol 26:71–77PubMedCrossRef Siu D, Cooke TD, Broekhiven LD, Lam M, Fisher B, Saunders G, Challis TW (1991) A standardized technique for lower limb radiography. Practice, applications, and error analysis. Invest Radiol 26:71–77PubMedCrossRef
36.
Zurück zum Zitat Smith TO, Ejtehadi F, Nichols R, Davies L, Donell ST, Hing CB (2010) Clinical and radiological outcomes of fixed- versus mobile-bearing total knee replacement: a meta-analysis. Knee Surg Sports Traumatol Arthrosc 18:325–340PubMedCrossRef Smith TO, Ejtehadi F, Nichols R, Davies L, Donell ST, Hing CB (2010) Clinical and radiological outcomes of fixed- versus mobile-bearing total knee replacement: a meta-analysis. Knee Surg Sports Traumatol Arthrosc 18:325–340PubMedCrossRef
37.
Zurück zum Zitat Spencer SJ, Baird K, Young D, Tait GR (2011) The Rotaglide mobile bearing knee arthroplasty. A 10- to 13-year review from an independent centre. Knee 19:20–23PubMedCrossRef Spencer SJ, Baird K, Young D, Tait GR (2011) The Rotaglide mobile bearing knee arthroplasty. A 10- to 13-year review from an independent centre. Knee 19:20–23PubMedCrossRef
38.
Zurück zum Zitat Stiehl JB, Hamelynck KJ, Voorhorst PE (2006) International multi-centre survivorship analysis of mobile bearing total knee arthroplasty. Int Orthop 30:190–199PubMedCrossRef Stiehl JB, Hamelynck KJ, Voorhorst PE (2006) International multi-centre survivorship analysis of mobile bearing total knee arthroplasty. Int Orthop 30:190–199PubMedCrossRef
39.
Zurück zum Zitat Van der Bracht H, Van Maele G, Verdonk P, Almqvist KF, Verdonk R, Freeman M (2010) Is there any superiority in the clinical outcome of mobile-bearing knee prosthesis designs compared to fixed-bearing total knee prosthesis designs in the treatment of osteoarthritis of the knee joint? A review of the literature. Knee Surg Sports Traumatol Arthrosc 18:367–374PubMedCrossRef Van der Bracht H, Van Maele G, Verdonk P, Almqvist KF, Verdonk R, Freeman M (2010) Is there any superiority in the clinical outcome of mobile-bearing knee prosthesis designs compared to fixed-bearing total knee prosthesis designs in the treatment of osteoarthritis of the knee joint? A review of the literature. Knee Surg Sports Traumatol Arthrosc 18:367–374PubMedCrossRef
Metadaten
Titel
Single-radius, multidirectional total knee replacement
verfasst von
Jean-Yves Jenny
Rolf Miehlke
Dominique Saragaglia
Robert Geyer
Numa Mercier
Jean-Yves Schoenahl
Birger Thiel
Publikationsdatum
01.12.2013
Verlag
Springer Berlin Heidelberg
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 12/2013
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-012-2178-0

Weitere Artikel der Ausgabe 12/2013

Knee Surgery, Sports Traumatology, Arthroscopy 12/2013 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders gilt das offenbar für weibliche Kranke, wie eine Studie zeigt.

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.