Skip to main content
Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy 8/2016

09.04.2015 | Knee

Alignment in knee flexion position during navigation-assisted total knee arthroplasty

verfasst von: Jae-Hyuk Yang, Anshul Dahuja, Jin-Kak Kim, Se-Hyeok Yun, Jung-Ro Yoon

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 8/2016

Einloggen, um Zugang zu erhalten

Abstract

Purpose

The aim of this study was to demonstrate the lower limb alignment in knee flexion position after navigation-assisted total knee arthroplasty using the gap technique and to identify the correlative factors.

Methods

One hundred and twenty consecutive osteoarthritic knees (120 patients) were prospectively enrolled for intraoperative data collection. All TKA surgeries were performed using the navigation system (OrthoPilot™, version 4.0; B. Braun Aesculap, Tuttlingen, Germany). Before and after final prosthesis implantation, the lower limb navigation alignment in both knee extension (0°) and knee flexion (90°) position was recorded. The knee flexion alignment was divided into three groups: varus, neutral and valgus alignment. To determine the factors of the alignment in knee flexion position, preoperative demographics, radiologic and intraoperative data were obtained. Pearson’s correlation (r) analysis was performed to find the correlation. The Knee Society Score and Western Ontario and McMaster Universities Osteoarthritis Index were compared between groups.

Results

Although all postoperative extension alignment was within neutral position (between −2° and +2°), postoperative knee flexion alignment was divided into three groups: varus (≤−3°), 24 cases (20 %); neutral (between −2° and +2°), 85 cases (70.8 %) and valgus (≥+3°) alignment, 11 cases (9.2 %). There were a good correlation of alignment in knee flexion position with the rotation of femoral component relative to posterior condylar axis (r = −0.502, p = 0.000) and weak correlations with posterior femoral cut thickness (lateral condyle) (r = 0.207, p = 0.026), medial flexion (90°) gap after femoral component rotation adjustment (r = 0.276, p = 0.003). Other variables did not show correlations. There were no statistical clinical differences between varus, neutral and valgus knee flexion alignment groups.

Conclusion

About 30 % of the cases showed malalignment of more than 3° in knee flexion position although with neutral alignment in extension position. The knee flexion alignment had a good correlation with the rotation of femoral component relative to posterior condylar axis. Neutral alignment in knee flexion position may be adjusted by femoral component rotation especially by the use of navigation system.

Level of evidence

IV.
Literatur
1.
Zurück zum Zitat Akagi M, Matsusue Y, Mata T, Asada Y, Horiguchi M, Iida H, Nakamura T (1999) Effect of rotational alignment on patellar tracking in total knee arthroplasty. Clin Orthop Relat Res 366:155–163CrossRefPubMed Akagi M, Matsusue Y, Mata T, Asada Y, Horiguchi M, Iida H, Nakamura T (1999) Effect of rotational alignment on patellar tracking in total knee arthroplasty. Clin Orthop Relat Res 366:155–163CrossRefPubMed
2.
Zurück zum Zitat Akagi M, Yamashita E, Nakagawa T, Asano T, Nakamura T (2001) Relationship between frontal knee alignment and reference axes in the distal femur. Clin Orthop Relat Res 388:147–156CrossRefPubMed Akagi M, Yamashita E, Nakagawa T, Asano T, Nakamura T (2001) Relationship between frontal knee alignment and reference axes in the distal femur. Clin Orthop Relat Res 388:147–156CrossRefPubMed
3.
Zurück zum Zitat Arima J, Whiteside LA, McCarthy DS, White SE (1995) Femoral rotational alignment, based on the anteroposterior axis, in total knee arthroplasty in a valgus knee. A technical note. J Bone Joint Surg Am 77:1331–1334PubMed Arima J, Whiteside LA, McCarthy DS, White SE (1995) Femoral rotational alignment, based on the anteroposterior axis, in total knee arthroplasty in a valgus knee. A technical note. J Bone Joint Surg Am 77:1331–1334PubMed
4.
Zurück zum Zitat Asano T, Akagi M, Nakamura T (2005) The functional flexion-extension axis of the knee corresponds to the surgical epicondylar axis: in vivo analysis using a biplanar image-matching technique. J Arthroplasty 20:1060–1067CrossRefPubMed Asano T, Akagi M, Nakamura T (2005) The functional flexion-extension axis of the knee corresponds to the surgical epicondylar axis: in vivo analysis using a biplanar image-matching technique. J Arthroplasty 20:1060–1067CrossRefPubMed
5.
Zurück zum Zitat Bae DK, Song SJ, Heo DB, Tak DH (2013) Does the severity of preoperative varus deformity influence postoperative alignment in both conventional and computer-assisted total knee arthroplasty? Knee Surg Sports Traumatol Arthrosc 21:2248–2254CrossRefPubMed Bae DK, Song SJ, Heo DB, Tak DH (2013) Does the severity of preoperative varus deformity influence postoperative alignment in both conventional and computer-assisted total knee arthroplasty? Knee Surg Sports Traumatol Arthrosc 21:2248–2254CrossRefPubMed
6.
Zurück zum Zitat Bellamy N, Buchanan WW, Goldsmith CH, Campbell J, Stitt LW (1988) Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee. J Rheumatol 15:1833–1840PubMed Bellamy N, Buchanan WW, Goldsmith CH, Campbell J, Stitt LW (1988) Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee. J Rheumatol 15:1833–1840PubMed
7.
Zurück zum Zitat Berger RA, Rubash HE, Seel MJ, Thompson WH, Crossett LS (1993) Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. Clin Orthop Relat Res 286:40–47PubMed Berger RA, Rubash HE, Seel MJ, Thompson WH, Crossett LS (1993) Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. Clin Orthop Relat Res 286:40–47PubMed
8.
Zurück zum Zitat Churchill DL, Incavo SJ, Johnson CC, Beynnon BD (1998) The transepicondylar axis approximates the optimal flexion axis of the knee. Clin Orthop Relat Res 356:111–118CrossRefPubMed Churchill DL, Incavo SJ, Johnson CC, Beynnon BD (1998) The transepicondylar axis approximates the optimal flexion axis of the knee. Clin Orthop Relat Res 356:111–118CrossRefPubMed
9.
Zurück zum Zitat Colle F, Bignozzi S, Lopomo N, Zaffagnini S, Sun L, Marcacci M (2012) Knee functional flexion axis in osteoarthritic patients: comparison in vivo with transepicondylar axis using a navigation system. Knee Surg Sports Traumatol Arthrosc 20:552–558CrossRefPubMed Colle F, Bignozzi S, Lopomo N, Zaffagnini S, Sun L, Marcacci M (2012) Knee functional flexion axis in osteoarthritic patients: comparison in vivo with transepicondylar axis using a navigation system. Knee Surg Sports Traumatol Arthrosc 20:552–558CrossRefPubMed
10.
Zurück zum Zitat Colle F, Lopomo N, Bruni D, Visani A, Iacono F, Zaffagnini S, Marcacci M (2014) Analysis of knee functional flexion axis in navigated TKA: identification and repeatability before and after implant positioning. Knee Surg Sports Traumatol Arthrosc 22:694–702CrossRefPubMed Colle F, Lopomo N, Bruni D, Visani A, Iacono F, Zaffagnini S, Marcacci M (2014) Analysis of knee functional flexion axis in navigated TKA: identification and repeatability before and after implant positioning. Knee Surg Sports Traumatol Arthrosc 22:694–702CrossRefPubMed
11.
Zurück zum Zitat Eckhoff DG, Bach JM, Spitzer VM, Reinig KD, Bagur MM, Baldini TH, Flannery NM (2005) Three-dimensional mechanics, kinematics, and morphology of the knee viewed in virtual reality. J Bone Joint Surg Am 87(Suppl 2):71–80CrossRefPubMed Eckhoff DG, Bach JM, Spitzer VM, Reinig KD, Bagur MM, Baldini TH, Flannery NM (2005) Three-dimensional mechanics, kinematics, and morphology of the knee viewed in virtual reality. J Bone Joint Surg Am 87(Suppl 2):71–80CrossRefPubMed
12.
Zurück zum Zitat Garvin KL, Barrera A, Mahoney CR, Hartman CW, Haider H (2013) Total knee arthroplasty with a computer-navigated saw: a pilot study. Clin Orthop Relat Res 471:155–161CrossRefPubMed Garvin KL, Barrera A, Mahoney CR, Hartman CW, Haider H (2013) Total knee arthroplasty with a computer-navigated saw: a pilot study. Clin Orthop Relat Res 471:155–161CrossRefPubMed
13.
Zurück zum Zitat Griffin FM, Insall JN, Scuderi GR (1998) The posterior condylar angle in osteoarthritic knees. J Arthroplasty 13:812–815CrossRefPubMed Griffin FM, Insall JN, Scuderi GR (1998) The posterior condylar angle in osteoarthritic knees. J Arthroplasty 13:812–815CrossRefPubMed
14.
Zurück zum Zitat Hollister AM, Jatana S, Singh AK, Sullivan WW, Lupichuk AG (1993) The axes of rotation of the knee. Clin Orthop Relat Res 290:259–268PubMed Hollister AM, Jatana S, Singh AK, Sullivan WW, Lupichuk AG (1993) The axes of rotation of the knee. Clin Orthop Relat Res 290:259–268PubMed
15.
Zurück zum Zitat Insall JN, Binazzi R, Soudry M, Mestriner LA (1985) Total knee arthroplasty. Clin Orthop Relat Res 192:13–22PubMed Insall JN, Binazzi R, Soudry M, Mestriner LA (1985) Total knee arthroplasty. Clin Orthop Relat Res 192:13–22PubMed
16.
Zurück zum Zitat Johnson TS, Andriacchi TP, Erdman AG (2004) Sensitivity of finite helical axis parameters to temporally varying realistic motion utilizing an idealized knee model. Proc Inst Mech Eng H 218:89–100CrossRefPubMed Johnson TS, Andriacchi TP, Erdman AG (2004) Sensitivity of finite helical axis parameters to temporally varying realistic motion utilizing an idealized knee model. Proc Inst Mech Eng H 218:89–100CrossRefPubMed
17.
Zurück zum Zitat Kanekasu K, Kondo M, Kadoya Y (2005) Axial radiography of the distal femur to assess rotational alignment in total knee arthroplasty. Clin Orthop Relat Res 434:193–197CrossRefPubMed Kanekasu K, Kondo M, Kadoya Y (2005) Axial radiography of the distal femur to assess rotational alignment in total knee arthroplasty. Clin Orthop Relat Res 434:193–197CrossRefPubMed
18.
Zurück zum Zitat Kang CH, Lee KJ, Bae KC, Cho CH, Lee SW, Shin HK, Lee YK, Bae JS (2012) Results of total knee arthroplasty with NexGen LPS-flex implant using navigation system (brain lab): results with a 5-year follow-up. Knee Surg Relat Res 24:208–213CrossRefPubMedPubMedCentral Kang CH, Lee KJ, Bae KC, Cho CH, Lee SW, Shin HK, Lee YK, Bae JS (2012) Results of total knee arthroplasty with NexGen LPS-flex implant using navigation system (brain lab): results with a 5-year follow-up. Knee Surg Relat Res 24:208–213CrossRefPubMedPubMedCentral
19.
Zurück zum Zitat Kinzel V, Ledger M, Shakespeare D (2005) Can the epicondylar axis be defined accurately in total knee arthroplasty? Knee 12:293–296CrossRefPubMed Kinzel V, Ledger M, Shakespeare D (2005) Can the epicondylar axis be defined accurately in total knee arthroplasty? Knee 12:293–296CrossRefPubMed
20.
Zurück zum Zitat Laskin RS (1995) Flexion space configuration in total knee arthroplasty. J Arthroplasty 10:657–660CrossRefPubMed Laskin RS (1995) Flexion space configuration in total knee arthroplasty. J Arthroplasty 10:657–660CrossRefPubMed
21.
Zurück zum Zitat Matsumoto T, Kuroda R, Kubo S, Muratsu H, Mizuno K, Kurosaka M (2009) The intra-operative joint gap in cruciate-retaining compared with posterior-stabilised total knee replacement. J Bone Joint Surg Br 91:475–480CrossRefPubMed Matsumoto T, Kuroda R, Kubo S, Muratsu H, Mizuno K, Kurosaka M (2009) The intra-operative joint gap in cruciate-retaining compared with posterior-stabilised total knee replacement. J Bone Joint Surg Br 91:475–480CrossRefPubMed
22.
Zurück zum Zitat Matsumoto T, Muratsu H, Tsumura N, Mizuno K, Kuroda R, Yoshiya S, Kurosaka M (2006) Joint gap kinematics in posterior-stabilized total knee arthroplasty measured by a new tensor with the navigation system. J Biomech Eng 128:867–871CrossRefPubMed Matsumoto T, Muratsu H, Tsumura N, Mizuno K, Kuroda R, Yoshiya S, Kurosaka M (2006) Joint gap kinematics in posterior-stabilized total knee arthroplasty measured by a new tensor with the navigation system. J Biomech Eng 128:867–871CrossRefPubMed
23.
Zurück zum Zitat Matziolis G, Krocker D, Weiss U, Tohtz S, Perka C (2007) A prospective, randomized study of computer-assisted and conventional total knee arthroplasty. Three-dimensional evaluation of implant alignment and rotation. J Bone Joint Surg Am 89:236–243CrossRefPubMed Matziolis G, Krocker D, Weiss U, Tohtz S, Perka C (2007) A prospective, randomized study of computer-assisted and conventional total knee arthroplasty. Three-dimensional evaluation of implant alignment and rotation. J Bone Joint Surg Am 89:236–243CrossRefPubMed
24.
Zurück zum Zitat Matziolis G, Pfiel S, Wassilew G, Boenicke H, Perka C (2011) Kinematic analysis of the flexion axis for correct femoral component placement. Knee Surg Sports Traumatol Arthrosc 19:1504–1509CrossRefPubMed Matziolis G, Pfiel S, Wassilew G, Boenicke H, Perka C (2011) Kinematic analysis of the flexion axis for correct femoral component placement. Knee Surg Sports Traumatol Arthrosc 19:1504–1509CrossRefPubMed
25.
Zurück zum Zitat Moon YW, Seo JG, Lim SJ, Yang JH (2010) Variability in femoral component rotation reference axes measured during navigation-assisted total knee arthroplasty using gap technique. J Arthroplasty 25:238–243CrossRefPubMed Moon YW, Seo JG, Lim SJ, Yang JH (2010) Variability in femoral component rotation reference axes measured during navigation-assisted total knee arthroplasty using gap technique. J Arthroplasty 25:238–243CrossRefPubMed
26.
Zurück zum Zitat Moon YW, Seo JG, Yang JH, Shon MS (2008) Analysis of the patellofemoral congruence angle according to the rotational alignment of the femoral component in navigation-guided TKA. Orthopedics 31:62–67 Moon YW, Seo JG, Yang JH, Shon MS (2008) Analysis of the patellofemoral congruence angle according to the rotational alignment of the femoral component in navigation-guided TKA. Orthopedics 31:62–67
27.
Zurück zum Zitat Moyad TF, Hughes RE, Urquhart A (2011) “Grand piano sign,” a marker for proper femoral component rotation during total knee arthroplasty. Am J Orthop 40:348–352PubMed Moyad TF, Hughes RE, Urquhart A (2011) “Grand piano sign,” a marker for proper femoral component rotation during total knee arthroplasty. Am J Orthop 40:348–352PubMed
28.
Zurück zum Zitat Oussedik S, Scholes C, Ferguson D, Roe J, Parker D (2012) Is femoral component rotation in a TKA reliably guided by the functional flexion axis? Clin Orthop Relat Res 470:3227–3232CrossRefPubMedPubMedCentral Oussedik S, Scholes C, Ferguson D, Roe J, Parker D (2012) Is femoral component rotation in a TKA reliably guided by the functional flexion axis? Clin Orthop Relat Res 470:3227–3232CrossRefPubMedPubMedCentral
29.
Zurück zum Zitat Schlatterer B, Linares JM, Chabrand P, Sprauel JM, Argenson JN (2014) Influence of the optical system and anatomic points on computer-assisted total knee arthroplasty. Orthop Traumatol Surg Res 100:395–402CrossRefPubMed Schlatterer B, Linares JM, Chabrand P, Sprauel JM, Argenson JN (2014) Influence of the optical system and anatomic points on computer-assisted total knee arthroplasty. Orthop Traumatol Surg Res 100:395–402CrossRefPubMed
30.
Zurück zum Zitat Siston RA, Cromie MJ, Gold GE, Goodman SB, Delp SL, Maloney WJ, Giori NJ (2008) Averaging different alignment axes improves femoral rotational alignment in computer-navigated total knee arthroplasty. J Bone Joint Surg Am 90:2098–2104CrossRefPubMed Siston RA, Cromie MJ, Gold GE, Goodman SB, Delp SL, Maloney WJ, Giori NJ (2008) Averaging different alignment axes improves femoral rotational alignment in computer-navigated total knee arthroplasty. J Bone Joint Surg Am 90:2098–2104CrossRefPubMed
31.
Zurück zum Zitat Siston RA, Patel JJ, Goodman SB, Delp SL, Giori NJ (2005) The variability of femoral rotational alignment in total knee arthroplasty. J Bone Joint Surg Am 87:2276–2280CrossRefPubMed Siston RA, Patel JJ, Goodman SB, Delp SL, Giori NJ (2005) The variability of femoral rotational alignment in total knee arthroplasty. J Bone Joint Surg Am 87:2276–2280CrossRefPubMed
32.
Zurück zum Zitat Suter T, Zanetti M, Schmid M, Romero J (2006) Reproducibility of measurement of femoral component rotation after total knee arthroplasty using computer tomography. J Arthroplasty 21:744–748CrossRefPubMed Suter T, Zanetti M, Schmid M, Romero J (2006) Reproducibility of measurement of femoral component rotation after total knee arthroplasty using computer tomography. J Arthroplasty 21:744–748CrossRefPubMed
33.
Zurück zum Zitat Tanaka K, Muratsu H, Mizuno K, Kuroda R, Yoshiya S, Kurosaka M (2007) Soft tissue balance measurement in anterior cruciate ligament-resected knee joint: cadaveric study as a model for cruciate-retaining total knee arthroplasty. J Orthop Sci 12:149–153CrossRefPubMed Tanaka K, Muratsu H, Mizuno K, Kuroda R, Yoshiya S, Kurosaka M (2007) Soft tissue balance measurement in anterior cruciate ligament-resected knee joint: cadaveric study as a model for cruciate-retaining total knee arthroplasty. J Orthop Sci 12:149–153CrossRefPubMed
34.
Zurück zum Zitat Vanlommel L, Vanlommel J, Claes S, Bellemans J (2013) Slight undercorrection following total knee arthroplasty results in superior clinical outcomes in varus knees. Knee Surg Sports Traumatol Arthrosc 21:2325–2330CrossRefPubMed Vanlommel L, Vanlommel J, Claes S, Bellemans J (2013) Slight undercorrection following total knee arthroplasty results in superior clinical outcomes in varus knees. Knee Surg Sports Traumatol Arthrosc 21:2325–2330CrossRefPubMed
35.
Zurück zum Zitat Verlinden C, Uvin P, Labey L, Luyckx JP, Bellemans J, Vandenneucker H (2010) The influence of malrotation of the femoral component in total knee replacement on the mechanics of patellofemoral contact during gait: an in vitro biomechanical study. J Bone Joint Surg Br 92:737–742CrossRefPubMed Verlinden C, Uvin P, Labey L, Luyckx JP, Bellemans J, Vandenneucker H (2010) The influence of malrotation of the femoral component in total knee replacement on the mechanics of patellofemoral contact during gait: an in vitro biomechanical study. J Bone Joint Surg Br 92:737–742CrossRefPubMed
36.
Zurück zum Zitat Wai Hung CL, Wai Pan Y, Kwong Yuen C, Hon Bong L, Lei Sha LW, Ho Man SW (2009) Interobserver and intraobserver error in distal femur transepicondylar axis measurement with computed tomography. J Arthroplasty 24:96–100CrossRefPubMed Wai Hung CL, Wai Pan Y, Kwong Yuen C, Hon Bong L, Lei Sha LW, Ho Man SW (2009) Interobserver and intraobserver error in distal femur transepicondylar axis measurement with computed tomography. J Arthroplasty 24:96–100CrossRefPubMed
37.
Zurück zum Zitat Yoon J-R, Oh K-J, Wang JH, Yang J-H (2014) Does patella position influence ligament balancing in total knee arthroplasty? Knee Surg Sports Traumatol Arthrosc. doi:10.1007/s00167-014-2879-7 Yoon J-R, Oh K-J, Wang JH, Yang J-H (2014) Does patella position influence ligament balancing in total knee arthroplasty? Knee Surg Sports Traumatol Arthrosc. doi:10.​1007/​s00167-014-2879-7
38.
Zurück zum Zitat Yoshino N, Takai S, Ohtsuki Y, Hirasawa Y (2001) Computed tomography measurement of the surgical and clinical transepicondylar axis of the distal femur in osteoarthritic knees. J Arthroplasty 16:493–497CrossRefPubMed Yoshino N, Takai S, Ohtsuki Y, Hirasawa Y (2001) Computed tomography measurement of the surgical and clinical transepicondylar axis of the distal femur in osteoarthritic knees. J Arthroplasty 16:493–497CrossRefPubMed
Metadaten
Titel
Alignment in knee flexion position during navigation-assisted total knee arthroplasty
verfasst von
Jae-Hyuk Yang
Anshul Dahuja
Jin-Kak Kim
Se-Hyeok Yun
Jung-Ro Yoon
Publikationsdatum
09.04.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 8/2016
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-015-3589-5

Weitere Artikel der Ausgabe 8/2016

Knee Surgery, Sports Traumatology, Arthroscopy 8/2016 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Medizinstudium Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Aquatherapie bei Fibromyalgie wirksamer als Trockenübungen

03.05.2024 Fibromyalgiesyndrom Nachrichten

Bewegungs-, Dehnungs- und Entspannungsübungen im Wasser lindern die Beschwerden von Patientinnen mit Fibromyalgie besser als das Üben auf trockenem Land. Das geht aus einer spanisch-brasilianischen Vergleichsstudie hervor.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.