Orthopaedic surgeons’ use and knowledge of ionizing radiation during surgical treatment for femoroacetabular impingement

verfasst von: Adriana J. Saroki, Coen Wijdicks, Marc J. Philippon, Asheesh Bedi

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 12/2016

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To better understand how radiograph imaging is currently used throughout perioperative care for femoroacetabular impingement (FAI) and to define surgeon knowledge and perspective on radiation safety when treating FAI.

Methods

An online questionnaire was designed to be completed by hip arthroscopists on the imaging modalities and projections they use during evaluation and treatment of FAI and the associated radiation exposures and safety. A sample of practicing attending orthopaedic surgeons was surveyed via an anonymous survey link emailed to corresponding authors on publications related to FAI. The anonymous survey link was also provided to orthopaedic surgeons at the 2014 Vail Hip Symposium.

Results

Ninety-one surgeons completed the survey. Of these participants, 72 surgeons (79.1 %) indicated they use pre-operative radiographs and intra-operative spot fluoroscopic images during FAI treatment. Thirty-three surgeons (36.3 %) use pre-operative computed tomography (CT). Twenty-three surgeons (25.3 %) use real-time moving fluoroscopy. A majority of surgeons incorrectly answered multiple-choice questions about which C-arm positions and settings result in the lowest doses of radiation to the surgeon or patient. Eighty-three surgeons (91.2 %) indicated they believe most orthopaedic surgeons need to be more informed about radiation safety.

Conclusions

This study gives a quantitative representation of the imaging modalities and projections utilized during perioperative treatment for FAI. This study also identified a lack of knowledge of radiation safety among orthopaedic surgeons treating patients with FAI and demonstrates the need for greater education.

Level of evidence

IV.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Ayeni OR, Belzile EL, Musahl V, Naudie D, Crouch S, Sprague S, Bhandari M (2014) Results of the perception of femoroacetabular impingement by surgeons survey (process). Knee Surg Sports Traumatol Arthrosc 22(4):906–910CrossRefPubMed Ayeni OR, Belzile EL, Musahl V, Naudie D, Crouch S, Sprague S, Bhandari M (2014) Results of the perception of femoroacetabular impingement by surgeons survey (process). Knee Surg Sports Traumatol Arthrosc 22(4):906–910CrossRefPubMed
2.
Zurück zum Zitat Biswas D, Bible JE, Bohan M, Simpson AK, Whang PG, Grauer JN (2009) Radiation exposure from musculoskeletal computerized tomographic scans. J Bone Joint Surg Am 91(8):1882–1889CrossRefPubMed Biswas D, Bible JE, Bohan M, Simpson AK, Whang PG, Grauer JN (2009) Radiation exposure from musculoskeletal computerized tomographic scans. J Bone Joint Surg Am 91(8):1882–1889CrossRefPubMed
3.
Zurück zum Zitat Budd H, Patchava A, Khanduja V (2012) Establishing the radiation risk from fluoroscopic-assisted arthroscopic surgery of the hip. Int Orthop 36:1803–1806CrossRefPubMedPubMedCentral Budd H, Patchava A, Khanduja V (2012) Establishing the radiation risk from fluoroscopic-assisted arthroscopic surgery of the hip. Int Orthop 36:1803–1806CrossRefPubMedPubMedCentral
4.
Zurück zum Zitat Burns S, Thornton R, Dauer LT (2013) Leaded eyeglasses substantially reduce radiation exposure of the surgeon’s eyes during acquisition of typical fluoroscopic views of the hip and pelvis. J Bone Joint Surg Am 95:1307–1311CrossRefPubMed Burns S, Thornton R, Dauer LT (2013) Leaded eyeglasses substantially reduce radiation exposure of the surgeon’s eyes during acquisition of typical fluoroscopic views of the hip and pelvis. J Bone Joint Surg Am 95:1307–1311CrossRefPubMed
5.
6.
Zurück zum Zitat Freudenberg LS, Beyer T (2011) Subjective perception of radiation risk. J Nucl Med 52(Suppl 2):29S–35SCrossRefPubMed Freudenberg LS, Beyer T (2011) Subjective perception of radiation risk. J Nucl Med 52(Suppl 2):29S–35SCrossRefPubMed
7.
Zurück zum Zitat Friedrich MJ (1999) Steps toward understanding, alleviating osteoarthritis will help aging population. JAMA 282(11):1023–1025CrossRefPubMed Friedrich MJ (1999) Steps toward understanding, alleviating osteoarthritis will help aging population. JAMA 282(11):1023–1025CrossRefPubMed
8.
Zurück zum Zitat Ganz R, Parvizi J, Beck M, Leunig M, Nötzli H, Siebenrock KA (2003) Femoroacetabular impingement: a cause for osteoarthritis of the hip. Clin Orthop Relat Res 417:112–120 Ganz R, Parvizi J, Beck M, Leunig M, Nötzli H, Siebenrock KA (2003) Femoroacetabular impingement: a cause for osteoarthritis of the hip. Clin Orthop Relat Res 417:112–120
9.
Zurück zum Zitat Gaymer CE, Achten J, Auckett R, Cooper L, Griffin D (2013) Fluoroscopic radiation exposure during hip arthroscopy. Arthroscopy 29:870–873CrossRefPubMed Gaymer CE, Achten J, Auckett R, Cooper L, Griffin D (2013) Fluoroscopic radiation exposure during hip arthroscopy. Arthroscopy 29:870–873CrossRefPubMed
10.
Zurück zum Zitat Genovese E, Spiga S, Vinci V, Aliprandi A, Di Pietto F, Coppolino F, Scialpi M, Giganti M (2013) Femoroacetabular impingement: role of imaging. Musculoskelet Surg 97(Suppl 2):S117–S126CrossRefPubMed Genovese E, Spiga S, Vinci V, Aliprandi A, Di Pietto F, Coppolino F, Scialpi M, Giganti M (2013) Femoroacetabular impingement: role of imaging. Musculoskelet Surg 97(Suppl 2):S117–S126CrossRefPubMed
11.
Zurück zum Zitat Giordano BD, Baumhauer JF, Morgan TL, Rechtinell GR (2009) Patient and surgeon radiation exposure: comparison of standard and mini-C-arm fluoroscopy. J Bone Joint Surg Am 91(2):297–304CrossRefPubMed Giordano BD, Baumhauer JF, Morgan TL, Rechtinell GR (2009) Patient and surgeon radiation exposure: comparison of standard and mini-C-arm fluoroscopy. J Bone Joint Surg Am 91(2):297–304CrossRefPubMed
12.
Zurück zum Zitat Giordano BD, Grauer JN, Miller CP, Morgan TL, Rechtinell GR (2011) Radiation exposure issues in orthopaedics. J Bone Joint Surg Am 93:e69CrossRefPubMed Giordano BD, Grauer JN, Miller CP, Morgan TL, Rechtinell GR (2011) Radiation exposure issues in orthopaedics. J Bone Joint Surg Am 93:e69CrossRefPubMed
13.
Zurück zum Zitat Larson AN, Rabenhorst B, De La Rocha A, Sucato DJ (2012) Limited intraobserver and interobserver reliability for the common measures of hip joint congruency used in dysplasia. Clin Orthop Relat Res 470(5):1414–1420CrossRefPubMed Larson AN, Rabenhorst B, De La Rocha A, Sucato DJ (2012) Limited intraobserver and interobserver reliability for the common measures of hip joint congruency used in dysplasia. Clin Orthop Relat Res 470(5):1414–1420CrossRefPubMed
14.
Zurück zum Zitat Mauro CS, Voos JE, Kelly BT (2010) Femoroacetabular impingement surgical techniques. Oper Tech Orthop 20(4):223–230CrossRef Mauro CS, Voos JE, Kelly BT (2010) Femoroacetabular impingement surgical techniques. Oper Tech Orthop 20(4):223–230CrossRef
15.
Zurück zum Zitat Mettler FA Jr, Huda W, Yoshizumi TT, Mahesh M (2008) Effective doses in radiology and diagnostic nuclear medicine: a catalog. Radiology 248(1):254–263CrossRefPubMed Mettler FA Jr, Huda W, Yoshizumi TT, Mahesh M (2008) Effective doses in radiology and diagnostic nuclear medicine: a catalog. Radiology 248(1):254–263CrossRefPubMed
16.
Zurück zum Zitat Milone MT, Bedi A, Poultsides L, Magennis E, Byrd JWT, Larson CM, Kelly BT (2013) Novel CT-based three-dimensional software improves the characterization of cam morphology. Clin Orthop Relat Res 471(8):2484–2491CrossRefPubMedPubMedCentral Milone MT, Bedi A, Poultsides L, Magennis E, Byrd JWT, Larson CM, Kelly BT (2013) Novel CT-based three-dimensional software improves the characterization of cam morphology. Clin Orthop Relat Res 471(8):2484–2491CrossRefPubMedPubMedCentral
17.
Zurück zum Zitat Nepple JJ, Martel JM, Kim Y-J, Zaltz I, Clohisy JC (2012) Do plain radiographs correlate with CT for imaging of cam-type femoroacetabular impingement? Clin Orthop Relat Res 470(12):3313–3320CrossRefPubMedPubMedCentral Nepple JJ, Martel JM, Kim Y-J, Zaltz I, Clohisy JC (2012) Do plain radiographs correlate with CT for imaging of cam-type femoroacetabular impingement? Clin Orthop Relat Res 470(12):3313–3320CrossRefPubMedPubMedCentral
19.
Zurück zum Zitat Rehani MM, Ciraj-Bjelac O, Vañó E, Miller DL, Walsh S, Giordano BD, Persliden J (2010) ICRP Publication 117. Radiological protection in fluoroscopically guided procedures performed outside the imaging department. Ann ICRP 40:1–102CrossRefPubMed Rehani MM, Ciraj-Bjelac O, Vañó E, Miller DL, Walsh S, Giordano BD, Persliden J (2010) ICRP Publication 117. Radiological protection in fluoroscopically guided procedures performed outside the imaging department. Ann ICRP 40:1–102CrossRefPubMed
20.
Zurück zum Zitat Ross JR, Bedi A, Stone RM, Sibilsky Enselman E, Leunig M, Kelly BT, Larson CM (2014) Intraoperative fluoroscopic imaging to treat cam deformities: correlation with 3-dimensional computed tomography. Am J Sports Med 42(6):1370–1376CrossRefPubMed Ross JR, Bedi A, Stone RM, Sibilsky Enselman E, Leunig M, Kelly BT, Larson CM (2014) Intraoperative fluoroscopic imaging to treat cam deformities: correlation with 3-dimensional computed tomography. Am J Sports Med 42(6):1370–1376CrossRefPubMed
21.
Zurück zum Zitat Soye JA, Paterson A (2008) A survey of awareness of radiation dose among health professionals in Northern Ireland. Br J Radiol 81:725–729CrossRefPubMed Soye JA, Paterson A (2008) A survey of awareness of radiation dose among health professionals in Northern Ireland. Br J Radiol 81:725–729CrossRefPubMed
Metadaten
Titel
Orthopaedic surgeons’ use and knowledge of ionizing radiation during surgical treatment for femoroacetabular impingement
verfasst von
Adriana J. Saroki
Coen Wijdicks
Marc J. Philippon
Asheesh Bedi
Publikationsdatum
07.08.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 12/2016
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-015-3734-1

Weitere Artikel der Ausgabe 12/2016

Knee Surgery, Sports Traumatology, Arthroscopy 12/2016 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.