Skip to main content
Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy 4/2019

15.09.2018 | Knee

No difference in outcomes and gait analysis between mechanical and kinematic knee alignment methods using robotic total knee arthroplasty

verfasst von: Je-Hyoung Yeo, Jong-Keun Seon, Dong-Hyun Lee, Eun-Kyoo Song

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 4/2019

Einloggen, um Zugang zu erhalten

Abstract

Purpose

The purpose of this study was to compare clinical outcomes and perform gait analysis during walking to identify differences in kinematic and kinetic parameters between two alignment methods in robotic-assisted total knee arthroplasty (TKA).

Methods

Sixty patients were randomly assigned to undergo robotic-assisted TKA using either mechanical (30 patients) or kinematic (30 patients) alignment method. Clinical outcomes including varus and valgus laxities, range of motion (ROM), Hospital for Specific Surgery (HSS), Knee Society Score (KSS), and Western Ontario and McMaster Universities (WOMAC) scores and radiological outcomes were evaluated. Gait analysis of 3D spatiotemporal, kinetic, and kinematic parameters during walking was then performed for 10 age and gender matched patients of each group to determine differences between the two alignment methods.

Results

The median follow-up duration of the mechanical method group was 8.7 (range 8.1–9.4) years and that of the kinematic method group was 8.4 (range 8.0–9.1) years. Clinical outcomes between the two groups showed no significant difference in HSS, WOMAC, ROM, KS pain, or function score at the last follow-up. No significant difference in varus and valgus laxity assessment, mechanical alignment of the lower limb, or perioperative complications was shown between the two groups. In gait analysis, no significant difference in kinematic or kinetic parameters was found except for varus angle (p < 0.05) and mediolateral ground reaction force (p < 0.05).

Conclusions

Results of this study show that mechanical and kinematic knee alignment methods provide comparable clinical and radiological outcomes after robotic total knee arthroplasty with an average follow-up of 8 years. There were no functional difference during walking between the two alignment methods either.

Level of evidence

II.
Literatur
1.
Zurück zum Zitat Bargren JH, Blaha JD, Freeman MAR (1983) Alignment in total knee arthroplasty: correlated biomechanical and clinical observations. Clin Orthop Relat Res 173:178–183 Bargren JH, Blaha JD, Freeman MAR (1983) Alignment in total knee arthroplasty: correlated biomechanical and clinical observations. Clin Orthop Relat Res 173:178–183
2.
Zurück zum Zitat Berend ME, Ritter MA, Meding JB et al (2004) Tibial component failure mechanisms in total knee arthroplasty. Clin Orthop Relat Res 428:26–34CrossRef Berend ME, Ritter MA, Meding JB et al (2004) Tibial component failure mechanisms in total knee arthroplasty. Clin Orthop Relat Res 428:26–34CrossRef
3.
Zurück zum Zitat Bonner TJ, Eardley WG, Patterson P, Gregg PJ (2011) The effect of post-operative mechanical axis alignment on the survival of primary total knee replacements after a follow-up of 15 years. J Bone Jt Surg Br 93:1217–1222CrossRef Bonner TJ, Eardley WG, Patterson P, Gregg PJ (2011) The effect of post-operative mechanical axis alignment on the survival of primary total knee replacements after a follow-up of 15 years. J Bone Jt Surg Br 93:1217–1222CrossRef
4.
Zurück zum Zitat Dorr LD, Boiardo RA (1986) Technical considerations in total knee arthroplasty. Clin Orthop Relat Res 205:5–11 Dorr LD, Boiardo RA (1986) Technical considerations in total knee arthroplasty. Clin Orthop Relat Res 205:5–11
5.
Zurück zum Zitat Dossett HG, Swartz GJ, Estrada NA, LeFevre GW, Kwasman BG (2012) Kinematically versus mechanically aligned total knee arthroplasty. Orthopedics 35:160–169 Dossett HG, Swartz GJ, Estrada NA, LeFevre GW, Kwasman BG (2012) Kinematically versus mechanically aligned total knee arthroplasty. Orthopedics 35:160–169
6.
Zurück zum Zitat Fang DM, Ritter MA, Davis KE (2009) Coronal alignment in total knee arthroplasty. J Arthroplast 24:39–43CrossRef Fang DM, Ritter MA, Davis KE (2009) Coronal alignment in total knee arthroplasty. J Arthroplast 24:39–43CrossRef
7.
Zurück zum Zitat Howell SM, Howell SJ, Kuznik KT, Cohen J, Hull ML (2013) Does a kinematically aligned total knee arthroplasty restore function without failure regardless of alignment category? Clin Orthop Relat Res 471:1000–1007CrossRefPubMed Howell SM, Howell SJ, Kuznik KT, Cohen J, Hull ML (2013) Does a kinematically aligned total knee arthroplasty restore function without failure regardless of alignment category? Clin Orthop Relat Res 471:1000–1007CrossRefPubMed
8.
Zurück zum Zitat Hungerford DS, Kenna RV, Krackow KA (1982) The porous coated anatomic total knee. Orthop Clin N Am 13:103–122 Hungerford DS, Kenna RV, Krackow KA (1982) The porous coated anatomic total knee. Orthop Clin N Am 13:103–122
9.
Zurück zum Zitat Hutt J, Masse V, Lavigne M, Vendittoli PA (2016) Functional joint line obliquity after kinematic total knee arthroplasty. Int Orthop 40:29–34CrossRefPubMed Hutt J, Masse V, Lavigne M, Vendittoli PA (2016) Functional joint line obliquity after kinematic total knee arthroplasty. Int Orthop 40:29–34CrossRefPubMed
10.
Zurück zum Zitat Insall JN, Binazzi R, Soudry M, Mestriner LA (1985) Total knee arthroplasty. Clin Orthop Relat Res 192:13–22 Insall JN, Binazzi R, Soudry M, Mestriner LA (1985) Total knee arthroplasty. Clin Orthop Relat Res 192:13–22
11.
Zurück zum Zitat Insall J. Tria AJ, Scott WN (1979) The total condylar knee prosthesis: the first 5 years. Clin Orthop Relat Res 145:68–77 Insall J. Tria AJ, Scott WN (1979) The total condylar knee prosthesis: the first 5 years. Clin Orthop Relat Res 145:68–77
12.
Zurück zum Zitat Insall J, Scott WN, Ranawat CS (1979) The total condylar knee prosthesis: a report of two hundred and twenty cases. J Bone Jt Surg Am 61:173–180CrossRef Insall J, Scott WN, Ranawat CS (1979) The total condylar knee prosthesis: a report of two hundred and twenty cases. J Bone Jt Surg Am 61:173–180CrossRef
13.
Zurück zum Zitat Ishikawa M, Kuriyama S, Ito H et al (2015) Kinematic alignment produces near-normal knee motion but increases contact stress after total knee arthroplasty: a case study on a single implant design. Knee 22:206–212CrossRefPubMed Ishikawa M, Kuriyama S, Ito H et al (2015) Kinematic alignment produces near-normal knee motion but increases contact stress after total knee arthroplasty: a case study on a single implant design. Knee 22:206–212CrossRefPubMed
14.
Zurück zum Zitat Kanekasu K, Kondo M, Kadoya Y (2005) Axial radiography of the distal femur to assess rotational alignment in total knee arthroplasty. Clin Orhop Relat Res 434:193–197CrossRef Kanekasu K, Kondo M, Kadoya Y (2005) Axial radiography of the distal femur to assess rotational alignment in total knee arthroplasty. Clin Orhop Relat Res 434:193–197CrossRef
15.
Zurück zum Zitat Lee JH, Seol YJ, Jung ST (2012) Utility of gait analysis and functional assessment of prosthetic reconstruction in bone tumor around the knee. J Korean Bone Jt Tumor Soc 18:51–58CrossRef Lee JH, Seol YJ, Jung ST (2012) Utility of gait analysis and functional assessment of prosthetic reconstruction in bone tumor around the knee. J Korean Bone Jt Tumor Soc 18:51–58CrossRef
16.
Zurück zum Zitat Magnussen RA, Weppe F, Demey G, Servien E, Lustig S (2011) Residual varus alignment dose not compromise results of TKAs in patients with preoperative varus. Clin Orthop Relat Res 469:3443–3450CrossRefPubMedPubMedCentral Magnussen RA, Weppe F, Demey G, Servien E, Lustig S (2011) Residual varus alignment dose not compromise results of TKAs in patients with preoperative varus. Clin Orthop Relat Res 469:3443–3450CrossRefPubMedPubMedCentral
17.
Zurück zum Zitat Matsumoto T, Takayama K, Ishida K et al (2017) Radiological and clinical comparison of kinematically versus mechanically aligned total knee arthroplasty. Bone Jt J 99:640–646CrossRef Matsumoto T, Takayama K, Ishida K et al (2017) Radiological and clinical comparison of kinematically versus mechanically aligned total knee arthroplasty. Bone Jt J 99:640–646CrossRef
18.
Zurück zum Zitat Moreland JR (1988) Mechanisms of failure of total knee arthroplasty. Clin Orthop Relat Res 226:49–64 Moreland JR (1988) Mechanisms of failure of total knee arthroplasty. Clin Orthop Relat Res 226:49–64
19.
Zurück zum Zitat Parratte S, Pagnano MW, Trousdale RT, Berry DJ (2010) Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacement. J Bone Jt Surg Am 92:2143–2149CrossRef Parratte S, Pagnano MW, Trousdale RT, Berry DJ (2010) Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacement. J Bone Jt Surg Am 92:2143–2149CrossRef
20.
Zurück zum Zitat Ritter MA, Davis KE, Meding JB et al (2011) The effect of alignment and BMI on failure of total knee replacement. J Bone Jt Surg Am 93:1588–1596CrossRef Ritter MA, Davis KE, Meding JB et al (2011) The effect of alignment and BMI on failure of total knee replacement. J Bone Jt Surg Am 93:1588–1596CrossRef
21.
Zurück zum Zitat Schutte LM, Narayanan U, Stout JL, Selber P, Gage JR, Schwartz MH (2000) An index for quantifying deviations from normal gait. Gait Posture 11:25–31CrossRefPubMed Schutte LM, Narayanan U, Stout JL, Selber P, Gage JR, Schwartz MH (2000) An index for quantifying deviations from normal gait. Gait Posture 11:25–31CrossRefPubMed
23.
Zurück zum Zitat Stahelin T, Kessler O, Pfirrmann C, Jacob HA, Romero J (2003) Fluoroscopically assisted stress radiography for varus–valgus stability assessment in flexion after total knee arthroplasty. J Arthroplast 18:513–515CrossRef Stahelin T, Kessler O, Pfirrmann C, Jacob HA, Romero J (2003) Fluoroscopically assisted stress radiography for varus–valgus stability assessment in flexion after total knee arthroplasty. J Arthroplast 18:513–515CrossRef
24.
Zurück zum Zitat Tew M, Waugh W (1985) Tibiofemoral alignment and the rsults of knee replacement. J Bone Jt Surg Br 67:551–556CrossRef Tew M, Waugh W (1985) Tibiofemoral alignment and the rsults of knee replacement. J Bone Jt Surg Br 67:551–556CrossRef
25.
Zurück zum Zitat Yim JH, Song EK, Khan MS, Sun ZH, Seon JK (2013) A comparison of classical and anatomical total knee alignment methods in robotic total knee arthroplasty: classical and anatomical knee alignment methods in TKA. J Arthroplast 28:932–937CrossRef Yim JH, Song EK, Khan MS, Sun ZH, Seon JK (2013) A comparison of classical and anatomical total knee alignment methods in robotic total knee arthroplasty: classical and anatomical knee alignment methods in TKA. J Arthroplast 28:932–937CrossRef
Metadaten
Titel
No difference in outcomes and gait analysis between mechanical and kinematic knee alignment methods using robotic total knee arthroplasty
verfasst von
Je-Hyoung Yeo
Jong-Keun Seon
Dong-Hyun Lee
Eun-Kyoo Song
Publikationsdatum
15.09.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 4/2019
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-018-5133-x

Weitere Artikel der Ausgabe 4/2019

Knee Surgery, Sports Traumatology, Arthroscopy 4/2019 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.