The Reliability of a Single Pulse Oximetry Reading as a Screening Test for Congenital Heart Disease in Otherwise Asymptomatic Newborn Infants

verfasst von: J. D. Reich, B. Connolly, G. Bradley, S. Littman, W. Koeppel, P. Lewycky, M. Liske

Erschienen in: Pediatric Cardiology | Ausgabe 5/2008

Einloggen, um Zugang zu erhalten

Abstract

Routine pulse oximetry has been studied to detect children with otherwise undiagnosed congenital heart disease prior to nursery discharge. The reported sensitivities in asymptomatic patients have been less than expected and vary widely, bringing into question the reliability of the test. The purpose of this study was to assess whether routine pulse oximetry contributes to identifying patients with critical congenital heart disease and to determine the reliability of a single pulse oximeter reading in screening asymptomatic newborn infants. Between December 26, 2003, and December 31, 2005, three hospitals in west central Florida performed a pulse oximetry routinely on all newborns at the time of discharge. Patients diagnosed with critical congenital heart disease during the study period were identified to assess whether the pulse oximetry reading initiated their diagnosis. In one hospital, the pulse oximeter data were evaluated for reliability. Downloaded data were compared to a log compiled by the nursery personnel, first without (phase 1) and then with (phase 2) their knowledge and additional training. Results were characterized as reliable, probe placed but reading not verifiable, or no evidence of probe placement. Of the 7962 infants who received oximetry testing, there were 12 postnatal diagnoses of critical congenital heart disease. None was initially identified by routine pulse oximetry. Pulse oximetry reliability improved substantially between phase 1 and phase 2 (38 v. 60%, p < 0.0001). Optimal reliability (>95%) was obtained by a nurse with a degree of LPN or higher performing an assessment of at least 360 seconds. Routine pulse oximetry was neither reliable nor an important diagnostic tool in our cohort. Important human factors (probe placement time, oximetry training, and nursing degree) impact single determination pulse oximetry reliability. With routine surveillance and quality improvement, the reliability of this test can be increased. Future studies to determine the effectiveness of pulse oximetry screening for the diagnosis of congenital heart disease in the asymptomatic newborn population must address these factors. Until such a study demonstrates acceptable sensitivity and clinical value, universal screening should not be instituted.
Literatur
1.
Zurück zum Zitat Abu-Harb M, Wyllie J, Hey E (1994) Presentation of obstructive left heart malformations in infancy. Arch Dis Child 71:F179–F183 Abu-Harb M, Wyllie J, Hey E (1994) Presentation of obstructive left heart malformations in infancy. Arch Dis Child 71:F179–F183
2.
Zurück zum Zitat Arlettaz R, Seraina Bauschatz A, Munkhoff M, Essers B, Bauersfeld U (2006) The contribution of pulse oximetry to the early detection of congenital heart disease in newborns. Eur J Pediatr 165:94–98 Arlettaz R, Seraina Bauschatz A, Munkhoff M, Essers B, Bauersfeld U (2006) The contribution of pulse oximetry to the early detection of congenital heart disease in newborns. Eur J Pediatr 165:94–98
3.
Zurück zum Zitat Bakr AF, Habib HS (2005) Combining pulse oximetry and clinical examination in screening for congenital heart disease. Pediatr Cardiol 26:832–835PubMedCrossRef Bakr AF, Habib HS (2005) Combining pulse oximetry and clinical examination in screening for congenital heart disease. Pediatr Cardiol 26:832–835PubMedCrossRef
4.
Zurück zum Zitat Barker SG (2002) “Motion-resistant” pulse oximetry: a comparison of new and old models. Anesth Analg 95:967–972PubMedCrossRef Barker SG (2002) “Motion-resistant” pulse oximetry: a comparison of new and old models. Anesth Analg 95:967–972PubMedCrossRef
5.
Zurück zum Zitat De-Wahl Granelli A, Mellander M, Sunnegardh J, Sandberg K Ostman-Smith I (2005) Screening for duct-dependent congenital heart disease with pulse oximetry: a critical evaluation of strategies to maximize sensitivity. Acta Paediatr 94:1590–1596PubMedCrossRef De-Wahl Granelli A, Mellander M, Sunnegardh J, Sandberg K Ostman-Smith I (2005) Screening for duct-dependent congenital heart disease with pulse oximetry: a critical evaluation of strategies to maximize sensitivity. Acta Paediatr 94:1590–1596PubMedCrossRef
6.
Zurück zum Zitat Elsas LJ (1996) Newborn screening. In: Rudolph AM (ed) Rudolph’s Pediatrics. Appleton & Lange, Norwalk, CT, pp 282–288 Elsas LJ (1996) Newborn screening. In: Rudolph AM (ed) Rudolph’s Pediatrics. Appleton & Lange, Norwalk, CT, pp 282–288
7.
Zurück zum Zitat Hoffman JIE (1990) Congenital heart disease: incidence and inheritance. Pediatr Clin North Am 37:25–43PubMed Hoffman JIE (1990) Congenital heart disease: incidence and inheritance. Pediatr Clin North Am 37:25–43PubMed
8.
Zurück zum Zitat Hoke TR, Donahue PK, Bawa PK et al (2002) Oxygen saturation as a screening test for critical congenital heart disease. Pediatr Cardiol 23:403–409PubMedCrossRef Hoke TR, Donahue PK, Bawa PK et al (2002) Oxygen saturation as a screening test for critical congenital heart disease. Pediatr Cardiol 23:403–409PubMedCrossRef
9.
Zurück zum Zitat Koppel RI, Druschel C, Carter T et al (2003) Effectiveness of pulse oximetry screening for congenital heart disease in asymptomatic newborns. Pediatrics 111:451–455PubMedCrossRef Koppel RI, Druschel C, Carter T et al (2003) Effectiveness of pulse oximetry screening for congenital heart disease in asymptomatic newborns. Pediatrics 111:451–455PubMedCrossRef
10.
Zurück zum Zitat Kuehl KS, Loffredo CA, Ferencz C (1999) Failure to diagnose congenital heart disease in infancy. Pediatrics 103:743–747PubMedCrossRef Kuehl KS, Loffredo CA, Ferencz C (1999) Failure to diagnose congenital heart disease in infancy. Pediatrics 103:743–747PubMedCrossRef
11.
Zurück zum Zitat Lawless ST (1994) Crying wolf: false alarms in a pediatric intensive care unit. Crit Care Med 22:981–985PubMedCrossRef Lawless ST (1994) Crying wolf: false alarms in a pediatric intensive care unit. Crit Care Med 22:981–985PubMedCrossRef
12.
Zurück zum Zitat Liske MR, Greeley CS, Law DJ, Reich JD (2006) Report of the Tennessee Task Force on Screening Newborn Infants for Critical Congenital Heart Disease. Pediatrics 118:E125CrossRef Liske MR, Greeley CS, Law DJ, Reich JD (2006) Report of the Tennessee Task Force on Screening Newborn Infants for Critical Congenital Heart Disease. Pediatrics 118:E125CrossRef
13.
Zurück zum Zitat Mellander M, Sunnegardh J (2006) Failure to diagnose critical heart disease in newborns before discharge—an increasing problem? Acta Pediatr 95:407–413CrossRef Mellander M, Sunnegardh J (2006) Failure to diagnose critical heart disease in newborns before discharge—an increasing problem? Acta Pediatr 95:407–413CrossRef
14.
Zurück zum Zitat Mitchell SC, Korones SB, Berendes HW (1971) Congenital heart disease in 56,109 births. Incidence and natural history. Circulation 43:323–332PubMed Mitchell SC, Korones SB, Berendes HW (1971) Congenital heart disease in 56,109 births. Incidence and natural history. Circulation 43:323–332PubMed
15.
Zurück zum Zitat Poets CF, Southall DP (1994) Non-invasive monitoring of oxygenation in infants and children: practical considerations and areas of concern. Pediatrics 93:737–746PubMed Poets CF, Southall DP (1994) Non-invasive monitoring of oxygenation in infants and children: practical considerations and areas of concern. Pediatrics 93:737–746PubMed
16.
Zurück zum Zitat Reich JD, Miller S, Brogdon B et al (2003) The use of pulse oximetry to detect congenital heart disease. J Pediatr 142:268–272PubMedCrossRef Reich JD, Miller S, Brogdon B et al (2003) The use of pulse oximetry to detect congenital heart disease. J Pediatr 142:268–272PubMedCrossRef
17.
Zurück zum Zitat Richmond S, Reay G, Abu Harb M (2002) Routine pulse oximetry in the newborn. Neonatal Intensive Care 15:11–17 Richmond S, Reay G, Abu Harb M (2002) Routine pulse oximetry in the newborn. Neonatal Intensive Care 15:11–17
18.
Zurück zum Zitat Richmond S, Wren C (2001) Early diagnosis of congenital heart disease. Semin Neonatol 6:27–35PubMedCrossRef Richmond S, Wren C (2001) Early diagnosis of congenital heart disease. Semin Neonatol 6:27–35PubMedCrossRef
19.
Zurück zum Zitat Rosati E, Chitano G, Dipaola L, De Felice C, Latini G (2005) Indications and limitations for a neonatal pulse oximetry screening of critical congenital heart disease. J Perinat Med 33:455–457PubMedCrossRef Rosati E, Chitano G, Dipaola L, De Felice C, Latini G (2005) Indications and limitations for a neonatal pulse oximetry screening of critical congenital heart disease. J Perinat Med 33:455–457PubMedCrossRef
20.
Zurück zum Zitat Salyer JW (2003) Neonatal and pediatric pulse oximetry. Respir Care 48:386–396PubMed Salyer JW (2003) Neonatal and pediatric pulse oximetry. Respir Care 48:386–396PubMed
21.
Zurück zum Zitat Samanek M, Zborilova B, Hrobonova V (1989) Prevalence, treatment, and outcome of heart disease in live born children: a prospective analysis of 91,823 live-born children. Pediatr Cardiol 10:205–211PubMedCrossRef Samanek M, Zborilova B, Hrobonova V (1989) Prevalence, treatment, and outcome of heart disease in live born children: a prospective analysis of 91,823 live-born children. Pediatr Cardiol 10:205–211PubMedCrossRef
22.
Zurück zum Zitat Thoele DG, Muster AJM, Paul MH (1987) Recognition of coarctation of the aorta: a continuing challenge for the primary care physician. Am J Dis Child 141:1201–1204PubMed Thoele DG, Muster AJM, Paul MH (1987) Recognition of coarctation of the aorta: a continuing challenge for the primary care physician. Am J Dis Child 141:1201–1204PubMed
23.
Zurück zum Zitat Varan B, Tokel K, Yilmaz G (1999) Malnutrition and growth failure in cyanotic and acyanotic congenital heart disease with and without pulmonary hypertension. Arch Dis Child 81:49–52PubMedCrossRef Varan B, Tokel K, Yilmaz G (1999) Malnutrition and growth failure in cyanotic and acyanotic congenital heart disease with and without pulmonary hypertension. Arch Dis Child 81:49–52PubMedCrossRef
24.
Zurück zum Zitat Ward KE, Pryor RW, Matson JR (1996) Delayed detection of coarctation in infancy: implications for timing of newborn follow-up. Pediatrics 86:972–976 Ward KE, Pryor RW, Matson JR (1996) Delayed detection of coarctation in infancy: implications for timing of newborn follow-up. Pediatrics 86:972–976
25.
Zurück zum Zitat Wren C, Richmond S, Donaldson L (1999) Presentation of congenital heart disease in infancy: implications for routine examination. Arch Dis Child 80:F49–F53 Wren C, Richmond S, Donaldson L (1999) Presentation of congenital heart disease in infancy: implications for routine examination. Arch Dis Child 80:F49–F53
Metadaten
Titel
The Reliability of a Single Pulse Oximetry Reading as a Screening Test for Congenital Heart Disease in Otherwise Asymptomatic Newborn Infants
verfasst von
J. D. Reich
B. Connolly
G. Bradley
S. Littman
W. Koeppel
P. Lewycky
M. Liske
Publikationsdatum
01.09.2008
Verlag
Springer-Verlag
Erschienen in
Pediatric Cardiology / Ausgabe 5/2008
Print ISSN: 0172-0643
Elektronische ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-008-9214-3

Weitere Artikel der Ausgabe 5/2008

Pediatric Cardiology 5/2008 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

Niedriger diastolischer Blutdruck erhöht Risiko für schwere kardiovaskuläre Komplikationen

25.04.2024 Hypotonie Nachrichten

Wenn unter einer medikamentösen Hochdrucktherapie der diastolische Blutdruck in den Keller geht, steigt das Risiko für schwere kardiovaskuläre Ereignisse: Darauf deutet eine Sekundäranalyse der SPRINT-Studie hin.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Adipositas-Medikament auch gegen Schlafapnoe wirksam

24.04.2024 Adipositas Nachrichten

Der als Antidiabetikum sowie zum Gewichtsmanagement zugelassene Wirkstoff Tirzepatid hat in Studien bei adipösen Patienten auch schlafbezogene Atmungsstörungen deutlich reduziert, informiert der Hersteller in einer Vorab-Meldung zum Studienausgang.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.