23.04.2022 | Pictorial Essay

Diagnostic challenges with central venous catheter studies

verfasst von: Kumar K. Shashi, Michael J. Callahan, Andy Tsai

Erschienen in: Pediatric Radiology | Ausgabe 8/2022

Einloggen, um Zugang zu erhalten

Abstract

A central venous catheter is typically made of silicone rubber or polyurethane and inserted into a large central vein to provide prolonged and direct access to central venous circulation. These catheters provide a safe and effective method to administer intravenous medications, nutritional supplements, fluids and blood products. However, a myriad of complications is associated with central venous catheters, including, but not limited to, mechanical malfunction or fracture, kinking, erroneous placement, line infection, fibrin sheath formation and venous thrombosis. Following clinical and radiographic evaluation, contrast-enhanced line studies constitute the next best diagnostic tool to assess the functionality of central venous catheters. However, there is a lack of standardization in the literature outlining how these studies should be performed. In addition, the interpretation of these studies can be problematic for general pediatric radiologists, many of whom are often not familiar with placement or manipulation of these catheters. In this pictorial review, we highlight the challenges associated with performing and interpreting fluoroscopically guided contrast injection studies, using case studies drawn from a large tertiary children’s hospital database for illustration. Revealing these challenges and understanding their causative mechanisms can improve the performance of these line studies.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Jaffray J, Bauman M, Massicotte P (2017) The impact of central venous catheters on pediatric venous thromboembolism. Front Pediatr 5:5CrossRef Jaffray J, Bauman M, Massicotte P (2017) The impact of central venous catheters on pediatric venous thromboembolism. Front Pediatr 5:5CrossRef
2.
Zurück zum Zitat Racadio JM, Doellman DA, Johnson ND et al (2001) Pediatric peripherally inserted central catheters: complication rates related to catheter tip location. Pediatrics 107:e28–e28CrossRef Racadio JM, Doellman DA, Johnson ND et al (2001) Pediatric peripherally inserted central catheters: complication rates related to catheter tip location. Pediatrics 107:e28–e28CrossRef
3.
Zurück zum Zitat de Jonge RC, Polderman KH, Gemke RJ (2005) Central venous catheter use in the pediatric patient: mechanical and infectious complications. Pediatr Crit Care Med 6:329–339CrossRef de Jonge RC, Polderman KH, Gemke RJ (2005) Central venous catheter use in the pediatric patient: mechanical and infectious complications. Pediatr Crit Care Med 6:329–339CrossRef
4.
Zurück zum Zitat Kim FM, Burrows PE, Hoffer FA, Chung T (1996) Interpreting the results of pediatric central venous catheter studies. Radiographics 16:747–754CrossRef Kim FM, Burrows PE, Hoffer FA, Chung T (1996) Interpreting the results of pediatric central venous catheter studies. Radiographics 16:747–754CrossRef
5.
Zurück zum Zitat Boardman P, Hughes JP (1998) Radiological evaluation and management of malfunctioning central venous catheters. Clin Radiol 53:10–16CrossRef Boardman P, Hughes JP (1998) Radiological evaluation and management of malfunctioning central venous catheters. Clin Radiol 53:10–16CrossRef
6.
Zurück zum Zitat Barnacle A, Arthurs OJ, Roebuck D, Hiorns MP (2008) Malfunctioning central venous catheters in children: a diagnostic approach. Pediatr Radiol 38:363–378, quiz 486–367 Barnacle A, Arthurs OJ, Roebuck D, Hiorns MP (2008) Malfunctioning central venous catheters in children: a diagnostic approach. Pediatr Radiol 38:363–378, quiz 486–367
7.
Zurück zum Zitat Faintuch S, Salazar GM (2008) Malfunction of dialysis catheters: management of fibrin sheath and related problems. Tech Vasc Interv Radiol 11:195–200CrossRef Faintuch S, Salazar GM (2008) Malfunction of dialysis catheters: management of fibrin sheath and related problems. Tech Vasc Interv Radiol 11:195–200CrossRef
8.
Zurück zum Zitat Knutstad K, Hager B, Hauser M (2003) Radiologic diagnosis and management of complications related to central venous access. Acta Radiol 44:508–516CrossRef Knutstad K, Hager B, Hauser M (2003) Radiologic diagnosis and management of complications related to central venous access. Acta Radiol 44:508–516CrossRef
9.
Zurück zum Zitat Crain MR, Horton MG, Mewissen MW (1998) Fibrin sheaths complicating central venous catheters. AJR Am J Roentgenol 171:341–346CrossRef Crain MR, Horton MG, Mewissen MW (1998) Fibrin sheaths complicating central venous catheters. AJR Am J Roentgenol 171:341–346CrossRef
10.
Zurück zum Zitat Tomaszewski M, Kosiak W, Irga N, Połczyńska K (2013) Ultrasound assessment of thrombotic complications in pediatric patients with tunneled central venous catheters. J Ultrason 13:451–459CrossRef Tomaszewski M, Kosiak W, Irga N, Połczyńska K (2013) Ultrasound assessment of thrombotic complications in pediatric patients with tunneled central venous catheters. J Ultrason 13:451–459CrossRef
11.
Zurück zum Zitat Zens T, Nichol P, Leys C et al (2019) Fractured pediatric central venous catheters - Repair or replace? J Pediatr Surg 54:165–169CrossRef Zens T, Nichol P, Leys C et al (2019) Fractured pediatric central venous catheters - Repair or replace? J Pediatr Surg 54:165–169CrossRef
12.
Zurück zum Zitat Cho JB, Park IY, Sung KY et al (2013) Pinch-off syndrome. J Korean Surg Soc 85:139–144CrossRef Cho JB, Park IY, Sung KY et al (2013) Pinch-off syndrome. J Korean Surg Soc 85:139–144CrossRef
13.
Zurück zum Zitat Hayward WA, Haseler LJ, Kettwich LG et al (2011) Pressure generated by syringes: implications for hydrodissection and injection of dense connective tissue lesions. Scand J Rheumatol 40:379–382CrossRef Hayward WA, Haseler LJ, Kettwich LG et al (2011) Pressure generated by syringes: implications for hydrodissection and injection of dense connective tissue lesions. Scand J Rheumatol 40:379–382CrossRef
Metadaten
Titel
Diagnostic challenges with central venous catheter studies
verfasst von
Kumar K. Shashi
Michael J. Callahan
Andy Tsai
Publikationsdatum
23.04.2022
Verlag
Springer Berlin Heidelberg
Erschienen in
Pediatric Radiology / Ausgabe 8/2022
Print ISSN: 0301-0449
Elektronische ISSN: 1432-1998
DOI
https://doi.org/10.1007/s00247-022-05362-2

Weitere Artikel der Ausgabe 8/2022

Pediatric Radiology 8/2022 Zur Ausgabe

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.