Skip to main content
Erschienen in: European Journal of Nuclear Medicine and Molecular Imaging 4/2009

01.04.2009 | Original Article

Standardization of the heart-to-mediastinum ratio of 123I-labelled-metaiodobenzylguanidine uptake using the dual energy window method: feasibility of correction with different camera–collimator combinations

verfasst von: Shinro Matsuo, Kenichi Nakajima, Koichi Okuda, Masaya Kawano, Takehiro Ishikawa, Tetsuo Hosoya, Junichi Taki, Seigo Kinuya

Erschienen in: European Journal of Nuclear Medicine and Molecular Imaging | Ausgabe 4/2009

Einloggen, um Zugang zu erhalten

Abstract

Background

Although the heart-to-mediastinum (H/M) ratio in a planar image has been used for practical quantification in 123I-metaiodobenzylguanidine (MIBG) imaging, standardization of the parameter is not yet established. We hypothesized that the value of the H/M ratio could be standardized to the various camera–collimator combinations.

Methods and results

Standard phantoms consisting of the heart and mediastinum were made. A low-energy high-resolution (LEHR) collimator and a medium-energy (ME) collimator were used. We examined multi-window correction methods with 123I- dual-window (IDW) acquisition, and planar images were obtained with IDW correction and the LEHR collimator. The images were obtained using the following gamma camera systems: GCA 9300A (Toshiba, Tokyo), E.CAM Signature (Toshiba/Siemens, Tokyo) and Varicam (GE, Tokyo). Cardiac phantom studies demonstrated that contamination of the H/M count ratio was greater with the LEHR collimator and least with the ME collimator. The corrected H/M ratio with the LEHR collimator was similar to that with ME collimators. The uncorrected H/M ratio with the ME collimator was linearly related to the H/M ratio with IDW correction with the LEHR collimator. The relationship between the uncorrected H/M ratios determined with the LEHR (E.CAM) and the ME collimators was y = 0.56x + 0.49, where y = H/M ratio with the E.CAM and x = H/M ratio with the ME collimator. The average normal values for the low-energy collimator (n=18) were 2.2±0.2 (initial H/M ratio) and 2.42±0.2 (delayed H/M ratio), and for the low/medium-energy (LME) collimator (n=14) were 2.63±0.25 (initial H/M ratio) and 2.87±0.19 (delayed H/M ratio). H/M ratios in previous clinical studies using LEHR collimators are comparable to those with ME collimators.

Conclusion

The IDW-corrected H/M ratios determined with the LEHR collimator were similar to those determined with the ME collimator. This finding could make it possible to standardize the H/M ratio in planar imaging among various collimators in the clinical setting.
Literatur
1.
Zurück zum Zitat Tamaki N. Guidelines for clinical use of cardiac nuclear medicine (JSC 2005). Circ J 2005;69(suppl IV):1125–202. Tamaki N. Guidelines for clinical use of cardiac nuclear medicine (JSC 2005). Circ J 2005;69(suppl IV):1125–202.
2.
Zurück zum Zitat Yamashina S, Yamazaki J. Neuronal imaging using SPECT. Eur J Nucl Med Mol Imaging 2007;34:939–50.PubMedCrossRef Yamashina S, Yamazaki J. Neuronal imaging using SPECT. Eur J Nucl Med Mol Imaging 2007;34:939–50.PubMedCrossRef
3.
Zurück zum Zitat Yamashina S, Yamazaki J. Role of MIBG myocardial scintigraphy in the assessment of heart failure: the need to establish evidence. Eur J Nucl Med Mol Imaging 2004;31:1353–5.PubMedCrossRef Yamashina S, Yamazaki J. Role of MIBG myocardial scintigraphy in the assessment of heart failure: the need to establish evidence. Eur J Nucl Med Mol Imaging 2004;31:1353–5.PubMedCrossRef
4.
Zurück zum Zitat Inoue Y, Suzuki A, Shirouzu I, Machida T, Yoshizawa Y, Akita F, et al. Effect of collimator choice on quantitative assessment of cardiac iodine 123 MIBG uptake. J Nucl Cardiol 2003;10:623–32.PubMedCrossRef Inoue Y, Suzuki A, Shirouzu I, Machida T, Yoshizawa Y, Akita F, et al. Effect of collimator choice on quantitative assessment of cardiac iodine 123 MIBG uptake. J Nucl Cardiol 2003;10:623–32.PubMedCrossRef
5.
Zurück zum Zitat Nakajima K, Matsubara K, Ishikawa T, Motomura N, Maeda R, Akhter N, et al. Correction of iodine-123-labeled meta-iodobenzylguanidine uptake with multi-window methods for standardization of the heart-to-mediastinum ratio. J Nucl Cardiol 2007;14:843–51.PubMedCrossRef Nakajima K, Matsubara K, Ishikawa T, Motomura N, Maeda R, Akhter N, et al. Correction of iodine-123-labeled meta-iodobenzylguanidine uptake with multi-window methods for standardization of the heart-to-mediastinum ratio. J Nucl Cardiol 2007;14:843–51.PubMedCrossRef
6.
Zurück zum Zitat Verberne HJ, Feenstra C, de Jong WM, Somsen GA, van Eck-Smit BL, Busemann Sokole E. Influence of collimator choice and simulated clinical conditions on 123I-MIBG heart/mediastinum ratios: a phantom study. Eur J Nucl Med Mol Imaging 2005;32:1100–7.PubMedCrossRef Verberne HJ, Feenstra C, de Jong WM, Somsen GA, van Eck-Smit BL, Busemann Sokole E. Influence of collimator choice and simulated clinical conditions on 123I-MIBG heart/mediastinum ratios: a phantom study. Eur J Nucl Med Mol Imaging 2005;32:1100–7.PubMedCrossRef
7.
Zurück zum Zitat Yamazaki J, Muto H, Kabano T, Yamashina S, Nanjo S, Inoue A. Evaluation of beta-blocker therapy in patients with dilated cardiomyopathy – clinical meaning of iodine 123-metaiodobenzylguanidine myocardial single-photon emission computed tomography. Am Heart J 2001;141:645–52.PubMedCrossRef Yamazaki J, Muto H, Kabano T, Yamashina S, Nanjo S, Inoue A. Evaluation of beta-blocker therapy in patients with dilated cardiomyopathy – clinical meaning of iodine 123-metaiodobenzylguanidine myocardial single-photon emission computed tomography. Am Heart J 2001;141:645–52.PubMedCrossRef
8.
Zurück zum Zitat Morozumi T, Kusuoka H, Fukuchi K, Tani A, Uehara T, Matsuda S, et al. Myocardial iodine-123-metaiodobenzylguanidine images and autonomic nerve activity in normal subjects. J Nucl Med 1997;38:49–52.PubMed Morozumi T, Kusuoka H, Fukuchi K, Tani A, Uehara T, Matsuda S, et al. Myocardial iodine-123-metaiodobenzylguanidine images and autonomic nerve activity in normal subjects. J Nucl Med 1997;38:49–52.PubMed
9.
Zurück zum Zitat Hattori N, Tamaki N, Hayashi T, Masuda I, Kudoh T, Tateno M, et al. Regional abnormality of iodine-123-MIBG in diabetic hearts. J Nucl Med 1996;37:1985–90.PubMed Hattori N, Tamaki N, Hayashi T, Masuda I, Kudoh T, Tateno M, et al. Regional abnormality of iodine-123-MIBG in diabetic hearts. J Nucl Med 1996;37:1985–90.PubMed
10.
Zurück zum Zitat Nakata T, Wakabayashi T, Kyuma M, Takahashi T, Tsuchihashi K, Shimamoto K. Cardiac metaiodobenzylguanidine activity can predict the long-term efficacy of angiotensin-converting enzyme inhibitors and/or beta-adrenoceptor blockers in patients with heart failure. Eur J Nucl Med Mol Imaging 2005;32:186–94.PubMedCrossRef Nakata T, Wakabayashi T, Kyuma M, Takahashi T, Tsuchihashi K, Shimamoto K. Cardiac metaiodobenzylguanidine activity can predict the long-term efficacy of angiotensin-converting enzyme inhibitors and/or beta-adrenoceptor blockers in patients with heart failure. Eur J Nucl Med Mol Imaging 2005;32:186–94.PubMedCrossRef
11.
Zurück zum Zitat Sakata K, Iida K, Kudo M, Yoshida H, Doi O. Prognostic value of I-123 metaiodobenzylguanidine imaging in vasospastic angina without significant coronary stenosis. Circ J 2005;69:171–6.PubMedCrossRef Sakata K, Iida K, Kudo M, Yoshida H, Doi O. Prognostic value of I-123 metaiodobenzylguanidine imaging in vasospastic angina without significant coronary stenosis. Circ J 2005;69:171–6.PubMedCrossRef
12.
Zurück zum Zitat Nishimura T, Sugishita Y, Sasaki Y. The results of questionnaire on quantitative assessment of 123I-metaiodobenzylguanidine myocardial scintigraphy in heart failure. Kaku Igaku 1997;34:1139–48.PubMed Nishimura T, Sugishita Y, Sasaki Y. The results of questionnaire on quantitative assessment of 123I-metaiodobenzylguanidine myocardial scintigraphy in heart failure. Kaku Igaku 1997;34:1139–48.PubMed
13.
Zurück zum Zitat Matsuo S, Nakamura Y, Matsui T, Matsumoto T, Kinoshita M. Detection of denervated but viable myocardium in cardiac sarcoidosis with I-123 MIBG and Tl-201 SPECT imaging. Ann Nucl Med 2001;15:373–5.PubMedCrossRef Matsuo S, Nakamura Y, Matsui T, Matsumoto T, Kinoshita M. Detection of denervated but viable myocardium in cardiac sarcoidosis with I-123 MIBG and Tl-201 SPECT imaging. Ann Nucl Med 2001;15:373–5.PubMedCrossRef
14.
Zurück zum Zitat Matsuo S, Nakamura Y, Matsumoto T, Takahashi M, Kinoshita M. Detection of coronary microvascular disease by means of cardiac scintigraphy. Can J Cardiol 2002;18:183–6.PubMed Matsuo S, Nakamura Y, Matsumoto T, Takahashi M, Kinoshita M. Detection of coronary microvascular disease by means of cardiac scintigraphy. Can J Cardiol 2002;18:183–6.PubMed
15.
Zurück zum Zitat Matsuo S, Nakamura Y, Tsutamoto T, Kinoshita M. Impairments of myocardial sympathetic activity may reflect the progression of myocardial damage or dysfunction in hypertrophic cardiomyopathy. J Nucl Cardiol 2002;9:407–12.PubMedCrossRef Matsuo S, Nakamura Y, Tsutamoto T, Kinoshita M. Impairments of myocardial sympathetic activity may reflect the progression of myocardial damage or dysfunction in hypertrophic cardiomyopathy. J Nucl Cardiol 2002;9:407–12.PubMedCrossRef
16.
Zurück zum Zitat Matsuo S, Nakae I, Takada M, Murata K, Nakamura Y. Noninvasive identification of myocardial sympathetic and metabolic abnormalities in a patient with restrictive cardiomyopathy in comparison with perfusion imaging. Ann Nucl Med 2002;16:569–72.PubMedCrossRef Matsuo S, Nakae I, Takada M, Murata K, Nakamura Y. Noninvasive identification of myocardial sympathetic and metabolic abnormalities in a patient with restrictive cardiomyopathy in comparison with perfusion imaging. Ann Nucl Med 2002;16:569–72.PubMedCrossRef
17.
Zurück zum Zitat Imamura Y, Fukuyama T, Mochizuki T, Miyagawa M, Watanabe K; Ehime MIBG Heart Failure Study Investigators. Prognostic value of iodine-123-metaiodobenzylguanidine imaging and cardiac natriuretic peptide levels in patients with left ventricular dysfunction resulting from cardiomyopathy. Jpn Circ J 2001;65:155–60.PubMedCrossRef Imamura Y, Fukuyama T, Mochizuki T, Miyagawa M, Watanabe K; Ehime MIBG Heart Failure Study Investigators. Prognostic value of iodine-123-metaiodobenzylguanidine imaging and cardiac natriuretic peptide levels in patients with left ventricular dysfunction resulting from cardiomyopathy. Jpn Circ J 2001;65:155–60.PubMedCrossRef
18.
Zurück zum Zitat Matsuo S, Nakamura Y, Matsumoto T, Nakae I, Takada M, Murata K, et al. Prognostic value of Iodine-123 metaiodobenzylguanidine imaging in patients with heart failure. Exp Clin Cardiol 2003;8:95–8.PubMed Matsuo S, Nakamura Y, Matsumoto T, Nakae I, Takada M, Murata K, et al. Prognostic value of Iodine-123 metaiodobenzylguanidine imaging in patients with heart failure. Exp Clin Cardiol 2003;8:95–8.PubMed
19.
Zurück zum Zitat Matsuo S, Takahashi M, Nakamura Y, Kinoshita M. Evaluation of cardiac sympathetic innervation with iodine-123-metaiodobenzylguanidine imaging in patients with silent myocardial ischemia. J Nucl Med 1996;37:712–7.PubMed Matsuo S, Takahashi M, Nakamura Y, Kinoshita M. Evaluation of cardiac sympathetic innervation with iodine-123-metaiodobenzylguanidine imaging in patients with silent myocardial ischemia. J Nucl Med 1996;37:712–7.PubMed
20.
Zurück zum Zitat Matsuo S, Nakamura Y, Takahashi M, Matsui T, Kusukawa J, Yoshida S, et al. Cardiac sympathetic dysfunction in athlete’s heart detected by 123I MIBG scintigraphy. Jpn Circ J 2001;65:371–4.PubMedCrossRef Matsuo S, Nakamura Y, Takahashi M, Matsui T, Kusukawa J, Yoshida S, et al. Cardiac sympathetic dysfunction in athlete’s heart detected by 123I MIBG scintigraphy. Jpn Circ J 2001;65:371–4.PubMedCrossRef
21.
Zurück zum Zitat Kobayashi H, Momose M, Kanaya S, Kondo C, Kusakabe K, Mitsuhashi N. Scatter correction by two-window method standardizes cardiac I-123 MIBG uptake in various gamma camera systems. Ann Nucl Med 2003;17:309–13.PubMedCrossRef Kobayashi H, Momose M, Kanaya S, Kondo C, Kusakabe K, Mitsuhashi N. Scatter correction by two-window method standardizes cardiac I-123 MIBG uptake in various gamma camera systems. Ann Nucl Med 2003;17:309–13.PubMedCrossRef
22.
Zurück zum Zitat Nagamatsu H, Momose M, Kobayashi H, Kusakabe K, Kasanuki H. Prognostic value of 123I-metaiodobenzylguanidine in patients with various heart diseases. Ann Nucl Med 2007;21:513–20.PubMedCrossRef Nagamatsu H, Momose M, Kobayashi H, Kusakabe K, Kasanuki H. Prognostic value of 123I-metaiodobenzylguanidine in patients with various heart diseases. Ann Nucl Med 2007;21:513–20.PubMedCrossRef
23.
Zurück zum Zitat Nakajima K, Kumita S, Ishida Y, Momose M, Hashimoto J, Morita K, et al. Creation and characterization of Japanese standards for myocardial perfusion SPECT: database from the Japanese Society of Nuclear Medicine working group. Ann Nucl Med 2007;21:505–11.PubMedCrossRef Nakajima K, Kumita S, Ishida Y, Momose M, Hashimoto J, Morita K, et al. Creation and characterization of Japanese standards for myocardial perfusion SPECT: database from the Japanese Society of Nuclear Medicine working group. Ann Nucl Med 2007;21:505–11.PubMedCrossRef
24.
Zurück zum Zitat Motomura N, Ichihara T, Takayama T, Aoki S, Kubo H, Takeda K. Practical compensation method of downscattered component due to high energy photon in 123I imaging. Kaku Igaku 1999;36:997–1005.PubMed Motomura N, Ichihara T, Takayama T, Aoki S, Kubo H, Takeda K. Practical compensation method of downscattered component due to high energy photon in 123I imaging. Kaku Igaku 1999;36:997–1005.PubMed
25.
Zurück zum Zitat Kasama S, Toyama T, Kumakura H, Takayama Y, Ichikawa S, Suzuki T, et al. Spironolactone improves cardiac sympathetic nerve activity and symptoms in patients with congestive heart failure. J Nucl Med 2002;43:1279–85.PubMed Kasama S, Toyama T, Kumakura H, Takayama Y, Ichikawa S, Suzuki T, et al. Spironolactone improves cardiac sympathetic nerve activity and symptoms in patients with congestive heart failure. J Nucl Med 2002;43:1279–85.PubMed
26.
Zurück zum Zitat Bai J, Hashimoto J, Ogawa K, Nakahara T, Suzuki T, Kubo A. Scatter correction based on an artificial neural network for 99mTc and 123I dual-isotope SPECT in myocardial and brain imaging. Ann Nucl Med 2007;21:25–32.PubMed Bai J, Hashimoto J, Ogawa K, Nakahara T, Suzuki T, Kubo A. Scatter correction based on an artificial neural network for 99mTc and 123I dual-isotope SPECT in myocardial and brain imaging. Ann Nucl Med 2007;21:25–32.PubMed
Metadaten
Titel
Standardization of the heart-to-mediastinum ratio of 123I-labelled-metaiodobenzylguanidine uptake using the dual energy window method: feasibility of correction with different camera–collimator combinations
verfasst von
Shinro Matsuo
Kenichi Nakajima
Koichi Okuda
Masaya Kawano
Takehiro Ishikawa
Tetsuo Hosoya
Junichi Taki
Seigo Kinuya
Publikationsdatum
01.04.2009
Verlag
Springer-Verlag
Erschienen in
European Journal of Nuclear Medicine and Molecular Imaging / Ausgabe 4/2009
Print ISSN: 1619-7070
Elektronische ISSN: 1619-7089
DOI
https://doi.org/10.1007/s00259-008-0971-2

Weitere Artikel der Ausgabe 4/2009

European Journal of Nuclear Medicine and Molecular Imaging 4/2009 Zur Ausgabe

Society Communications

Society Communications April 09