Skip to main content
Erschienen in: Abdominal Radiology 6/2020

02.01.2020 | Practice

Cost-effectiveness of dual-energy CT versus multiphasic single-energy CT and MRI for characterization of incidental indeterminate renal lesions

verfasst von: Bhavik N. Patel, Artem T. Boltyenkov, Maria G. Martinez, Domenico Mastrodicasa, Daniele Marin, R. Brooke Jeffrey, Benjamin Chung, Pari Pandharipande, Avinash Kambadakone

Erschienen in: Abdominal Radiology | Ausgabe 6/2020

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To evaluate the cost-effectiveness of DECT versus multiphasic CT and MRI for characterizing small incidentally detected indeterminate renal lesions using a Markov Monte Carlo decision-analytic model.

Background

Incidental renal lesions are commonly encountered due to the increasing utilization of medical imaging and the increasing prevalence of renal lesions with age. Currently recommended imaging modalities to further characterize incidental indeterminate renal lesions have some inherent drawbacks. Single-phase DECT may overcome these limitations, but its cost-effectiveness remains uncertain.

Materials and methods

A decision-analytic (Markov) model was constructed to estimate life expectancy and lifetime costs for otherwise healthy 64-year-old patients with small (≤ 4 cm) incidentally detected, indeterminate renal lesions on routine imaging (e.g., ultrasound or single-phase CT). Three strategies for evaluating renal lesions for enhancement were compared: multiphase SECT (e.g., true unenhanced and nephrographic phase), multiphasic MRI, and single-phase DECT (nephrographic phase in dual-energy mode). The model incorporated modality-specific diagnostic test performance, incidence, and prevalence of incidental renal cell carcinomas (RCCs), effectiveness, costs, and health outcomes. An incremental cost-effectiveness analysis was performed to identify strategy preference at willingness-to-pay (WTP) thresholds of $50,000 and $100,000 per quality-adjusted life-year (QALY) gained. Deterministic and probabilistic sensitivity analysis were performed.

Results

In the base case analysis, expected mean costs per patient undergoing characterization of incidental renal lesions were $2567 for single-phase DECT, $3290 for multiphasic CT, and $3751 for multiphasic MRI. Associated quality-adjusted life-years were the highest for single-phase DECT at 0.962, for multiphasic MRI it was 0.940, and was the lowest for multiphasic CT at 0.925. Because of lower associated costs and higher effectiveness, the single-phase DECT strategy dominated the other two strategies.

Conclusions

Single-phase DECT is potentially more cost-effective than multiphasic SECT and MRI for evaluating small incidentally detected indeterminate renal lesions.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Berland LL, Silverman SG, Gore RM, et al. Managing incidental findings on abdominal CT: white paper of the ACR incidental findings committee. J Am Coll Radiol. 2010;7(10):754-73.PubMed Berland LL, Silverman SG, Gore RM, et al. Managing incidental findings on abdominal CT: white paper of the ACR incidental findings committee. J Am Coll Radiol. 2010;7(10):754-73.PubMed
2.
Zurück zum Zitat Herts BR, Silverman SG, Hindman NM, et al. Management of the Incidental Renal Mass on CT: A White Paper of the ACR Incidental Findings Committee. J Am Coll Radiol. 2018;15(2):264-73PubMed Herts BR, Silverman SG, Hindman NM, et al. Management of the Incidental Renal Mass on CT: A White Paper of the ACR Incidental Findings Committee. J Am Coll Radiol. 2018;15(2):264-73PubMed
3.
Zurück zum Zitat Carrim ZI, Murchison JT. The prevalence of simple renal and hepatic cysts detected by spiral computed tomography. Clin Radiol. 2003;58(8):626-9.PubMed Carrim ZI, Murchison JT. The prevalence of simple renal and hepatic cysts detected by spiral computed tomography. Clin Radiol. 2003;58(8):626-9.PubMed
4.
Zurück zum Zitat Silverman SG, Israel GM, Herts BR, Richie JP. Management of the incidental renal mass. Radiology. 2008;249(1):16-31.PubMed Silverman SG, Israel GM, Herts BR, Richie JP. Management of the incidental renal mass. Radiology. 2008;249(1):16-31.PubMed
5.
Zurück zum Zitat Silverman SG, Israel GM, Trinh QD. Incompletely characterized incidental renal masses: emerging data support conservative management. Radiology. 2015;275(1):28-42PubMed Silverman SG, Israel GM, Trinh QD. Incompletely characterized incidental renal masses: emerging data support conservative management. Radiology. 2015;275(1):28-42PubMed
6.
Zurück zum Zitat Ljungberg B, Cowan NC, Hanbury DC, et al. EAU guidelines on renal cell carcinoma: the 2010 update. Eur Urol. 2010;58(3):398-406.PubMed Ljungberg B, Cowan NC, Hanbury DC, et al. EAU guidelines on renal cell carcinoma: the 2010 update. Eur Urol. 2010;58(3):398-406.PubMed
7.
Zurück zum Zitat Znaor A, Lortet-Tieulent J, Laversanne M, Jemal A, Bray F. International variations and trends in renal cell carcinoma incidence and mortality. Eur Urol. 2015;67(3):519-30.PubMed Znaor A, Lortet-Tieulent J, Laversanne M, Jemal A, Bray F. International variations and trends in renal cell carcinoma incidence and mortality. Eur Urol. 2015;67(3):519-30.PubMed
8.
Zurück zum Zitat Volpe A, Panzarella T, Rendon RA, Haider MA, Kondylis FI, Jewett MA. The natural history of incidentally detected small renal masses. Cancer. 2004;100(4):738-45.PubMed Volpe A, Panzarella T, Rendon RA, Haider MA, Kondylis FI, Jewett MA. The natural history of incidentally detected small renal masses. Cancer. 2004;100(4):738-45.PubMed
9.
Zurück zum Zitat Capitanio U, Bensalah K, Bex A, et al. Epidemiology of Renal Cell Carcinoma. Eur Urol. 2019;75(1):74-84.PubMed Capitanio U, Bensalah K, Bex A, et al. Epidemiology of Renal Cell Carcinoma. Eur Urol. 2019;75(1):74-84.PubMed
10.
Zurück zum Zitat Israel GM, Bosniak MA. How I do it: evaluating renal masses. Radiology. 2005;236(2):441-50.PubMed Israel GM, Bosniak MA. How I do it: evaluating renal masses. Radiology. 2005;236(2):441-50.PubMed
11.
Zurück zum Zitat Campbell S, Uzzo RG, Allaf ME, et al. Renal Mass and Localized Renal Cancer: AUA Guideline. J Urol. 2017;198(3):520-9.PubMed Campbell S, Uzzo RG, Allaf ME, et al. Renal Mass and Localized Renal Cancer: AUA Guideline. J Urol. 2017;198(3):520-9.PubMed
12.
Zurück zum Zitat Gill IS, Aron M, Gervais DA, Jewett MA. Clinical practice. Small renal mass. N Engl J Med. 2010;362(7):624-34. Gill IS, Aron M, Gervais DA, Jewett MA. Clinical practice. Small renal mass. N Engl J Med. 2010;362(7):624-34.
13.
Zurück zum Zitat Mileto A, Nelson RC, Samei E, et al. Impact of dual-energy multi-detector row CT with virtual monochromatic imaging on renal cyst pseudoenhancement: in vitro and in vivo study. Radiology. 2014;272(3):767-76.PubMed Mileto A, Nelson RC, Samei E, et al. Impact of dual-energy multi-detector row CT with virtual monochromatic imaging on renal cyst pseudoenhancement: in vitro and in vivo study. Radiology. 2014;272(3):767-76.PubMed
14.
Zurück zum Zitat Tappouni R, Kissane J, Sarwani N, Lehman EB. Pseudoenhancement of renal cysts: influence of lesion size, lesion location, slice thickness, and number of MDCT detectors. AJR Am J Roentgenol. 2012;198(1):133-7.PubMed Tappouni R, Kissane J, Sarwani N, Lehman EB. Pseudoenhancement of renal cysts: influence of lesion size, lesion location, slice thickness, and number of MDCT detectors. AJR Am J Roentgenol. 2012;198(1):133-7.PubMed
15.
Zurück zum Zitat Birnbaum BA, Hindman N, Lee J, Babb JS. Multi-detector row CT attenuation measurements: assessment of intra- and interscanner variability with an anthropomorphic body CT phantom. Radiology. 2007;242(1):109-19.PubMed Birnbaum BA, Hindman N, Lee J, Babb JS. Multi-detector row CT attenuation measurements: assessment of intra- and interscanner variability with an anthropomorphic body CT phantom. Radiology. 2007;242(1):109-19.PubMed
16.
Zurück zum Zitat Mileto A, Barina A, Marin D, et al. Virtual Monochromatic Images from Dual-Energy Multidetector CT: Variance in CT Numbers from the Same Lesion between Single-Source Projection-based and Dual-Source Image-based Implementations. Radiology. 2016;279(1):269-77.PubMed Mileto A, Barina A, Marin D, et al. Virtual Monochromatic Images from Dual-Energy Multidetector CT: Variance in CT Numbers from the Same Lesion between Single-Source Projection-based and Dual-Source Image-based Implementations. Radiology. 2016;279(1):269-77.PubMed
17.
Zurück zum Zitat Solomon J, Mileto A, Nelson RC, Roy Choudhury K, Samei E. Quantitative Features of Liver Lesions, Lung Nodules, and Renal Stones at Multi-Detector Row CT Examinations: Dependency on Radiation Dose and Reconstruction Algorithm. Radiology. 2016;279(1):185-94.PubMed Solomon J, Mileto A, Nelson RC, Roy Choudhury K, Samei E. Quantitative Features of Liver Lesions, Lung Nodules, and Renal Stones at Multi-Detector Row CT Examinations: Dependency on Radiation Dose and Reconstruction Algorithm. Radiology. 2016;279(1):185-94.PubMed
18.
Zurück zum Zitat Bosniak MA. The small (less than or equal to 3.0 cm) renal parenchymal tumor: detection, diagnosis, and controversies. Radiology. 1991;179(2):307-17. Bosniak MA. The small (less than or equal to 3.0 cm) renal parenchymal tumor: detection, diagnosis, and controversies. Radiology. 1991;179(2):307-17.
19.
Zurück zum Zitat Graser A, Becker CR, Staehler M, et al. Single-phase dual-energy CT allows for characterization of renal masses as benign or malignant. Invest Radiol. 2010;45(7):399-405.PubMed Graser A, Becker CR, Staehler M, et al. Single-phase dual-energy CT allows for characterization of renal masses as benign or malignant. Invest Radiol. 2010;45(7):399-405.PubMed
20.
Zurück zum Zitat Silverman SG, Mortele KJ, Tuncali K, Jinzaki M, Cibas ES. Hyperattenuating renal masses: etiologies, pathogenesis, and imaging evaluation. Radiographics. 2007;27(4):1131-43.PubMed Silverman SG, Mortele KJ, Tuncali K, Jinzaki M, Cibas ES. Hyperattenuating renal masses: etiologies, pathogenesis, and imaging evaluation. Radiographics. 2007;27(4):1131-43.PubMed
21.
Zurück zum Zitat Hecht EM, Israel GM, Krinsky GA, et al. Renal masses: quantitative analysis of enhancement with signal intensity measurements versus qualitative analysis of enhancement with image subtraction for diagnosing malignancy at MR imaging. Radiology. 2004;232(2):373-8.PubMed Hecht EM, Israel GM, Krinsky GA, et al. Renal masses: quantitative analysis of enhancement with signal intensity measurements versus qualitative analysis of enhancement with image subtraction for diagnosing malignancy at MR imaging. Radiology. 2004;232(2):373-8.PubMed
22.
Zurück zum Zitat Katsuda T, Kuroda C, Fujita M. Reducing misregistration of mask image in hepatic DSA. Radiol Technol. 1997;68(6):487-90.PubMed Katsuda T, Kuroda C, Fujita M. Reducing misregistration of mask image in hepatic DSA. Radiol Technol. 1997;68(6):487-90.PubMed
23.
Zurück zum Zitat Ascenti G, Mazziotti S, Mileto A, et al. Dual-source dual-energy CT evaluation of complex cystic renal masses. AJR Am J Roentgenol. 2012;199(5):1026-34.PubMed Ascenti G, Mazziotti S, Mileto A, et al. Dual-source dual-energy CT evaluation of complex cystic renal masses. AJR Am J Roentgenol. 2012;199(5):1026-34.PubMed
24.
Zurück zum Zitat Kaza RK, Caoili EM, Cohan RH, Platt JF. Distinguishing enhancing from nonenhancing renal lesions with fast kilovoltage-switching dual-energy CT. AJR Am J Roentgenol. 2011;197(6):1375-81.PubMed Kaza RK, Caoili EM, Cohan RH, Platt JF. Distinguishing enhancing from nonenhancing renal lesions with fast kilovoltage-switching dual-energy CT. AJR Am J Roentgenol. 2011;197(6):1375-81.PubMed
25.
Zurück zum Zitat Marin D, Davis D, Roy Choudhury K, et al. Characterization of Small Focal Renal Lesions: Diagnostic Accuracy with Single-Phase Contrast-enhanced Dual-Energy CT with Material Attenuation Analysis Compared with Conventional Attenuation Measurements. Radiology. 2017;284(3):737-47.PubMed Marin D, Davis D, Roy Choudhury K, et al. Characterization of Small Focal Renal Lesions: Diagnostic Accuracy with Single-Phase Contrast-enhanced Dual-Energy CT with Material Attenuation Analysis Compared with Conventional Attenuation Measurements. Radiology. 2017;284(3):737-47.PubMed
26.
Zurück zum Zitat Patel BN, Alexander L, Allen B, et al. Dual-energy CT workflow: multi-institutional consensus on standardization of abdominopelvic MDCT protocols. Abdom Radiol (NY). 2016. Patel BN, Alexander L, Allen B, et al. Dual-energy CT workflow: multi-institutional consensus on standardization of abdominopelvic MDCT protocols. Abdom Radiol (NY). 2016.
27.
Zurück zum Zitat Patel BN, Bibbey A, Choudhury KR, Leder RA, Nelson RC, Marin D. Characterization of Small (< 4 cm) Focal Renal Lesions: Diagnostic Accuracy of Spectral Analysis Using Single-Phase Contrast-Enhanced Dual-Energy CT. AJR Am J Roentgenol. 2017;209(4):815-25PubMed Patel BN, Bibbey A, Choudhury KR, Leder RA, Nelson RC, Marin D. Characterization of Small (< 4 cm) Focal Renal Lesions: Diagnostic Accuracy of Spectral Analysis Using Single-Phase Contrast-Enhanced Dual-Energy CT. AJR Am J Roentgenol. 2017;209(4):815-25PubMed
28.
Zurück zum Zitat Jung DC, Oh YT, Kim MD, Park M. Usefulness of the virtual monochromatic image in dual-energy spectral CT for decreasing renal cyst pseudoenhancement: a phantom study. AJR Am J Roentgenol. 2012;199(6):1316-9.PubMed Jung DC, Oh YT, Kim MD, Park M. Usefulness of the virtual monochromatic image in dual-energy spectral CT for decreasing renal cyst pseudoenhancement: a phantom study. AJR Am J Roentgenol. 2012;199(6):1316-9.PubMed
29.
Zurück zum Zitat Marin D, Boll DT, Mileto A, Nelson RC. State of the art: dual-energy CT of the abdomen. Radiology. 2014;271(2):327-42.PubMed Marin D, Boll DT, Mileto A, Nelson RC. State of the art: dual-energy CT of the abdomen. Radiology. 2014;271(2):327-42.PubMed
30.
Zurück zum Zitat Matsumoto K, Jinzaki M, Tanami Y, Ueno A, Yamada M, Kuribayashi S. Virtual monochromatic spectral imaging with fast kilovoltage switching: improved image quality as compared with that obtained with conventional 120-kVp CT. Radiology. 2011;259(1):257-62.PubMed Matsumoto K, Jinzaki M, Tanami Y, Ueno A, Yamada M, Kuribayashi S. Virtual monochromatic spectral imaging with fast kilovoltage switching: improved image quality as compared with that obtained with conventional 120-kVp CT. Radiology. 2011;259(1):257-62.PubMed
31.
Zurück zum Zitat Yu L, Christner JA, Leng S, Wang J, Fletcher JG, McCollough CH. Virtual monochromatic imaging in dual-source dual-energy CT: radiation dose and image quality. Med Phys. 2011;38(12):6371-9.PubMedPubMedCentral Yu L, Christner JA, Leng S, Wang J, Fletcher JG, McCollough CH. Virtual monochromatic imaging in dual-source dual-energy CT: radiation dose and image quality. Med Phys. 2011;38(12):6371-9.PubMedPubMedCentral
32.
Zurück zum Zitat Patel BN, Vernuccio F, Meyer M, et al. Dual-Energy CT Material Density Iodine Quantification for Distinguishing Vascular From Nonvascular Renal Lesions: Normalization Reduces Intermanufacturer Threshold Variability. AJR Am J Roentgenol. 2019;212(2):366-76.PubMed Patel BN, Vernuccio F, Meyer M, et al. Dual-Energy CT Material Density Iodine Quantification for Distinguishing Vascular From Nonvascular Renal Lesions: Normalization Reduces Intermanufacturer Threshold Variability. AJR Am J Roentgenol. 2019;212(2):366-76.PubMed
33.
Zurück zum Zitat Chandarana H, Megibow AJ, Cohen BA, et al. Iodine quantification with dual-energy CT: phantom study and preliminary experience with renal masses. AJR Am J Roentgenol. 2011;196(6):W693-700.PubMed Chandarana H, Megibow AJ, Cohen BA, et al. Iodine quantification with dual-energy CT: phantom study and preliminary experience with renal masses. AJR Am J Roentgenol. 2011;196(6):W693-700.PubMed
34.
Zurück zum Zitat Mileto A, Marin D, Alfaro-Cordoba M, et al. Iodine quantification to distinguish clear cell from papillary renal cell carcinoma at dual-energy multidetector CT: a multireader diagnostic performance study. Radiology. 2014;273(3):813-20.PubMed Mileto A, Marin D, Alfaro-Cordoba M, et al. Iodine quantification to distinguish clear cell from papillary renal cell carcinoma at dual-energy multidetector CT: a multireader diagnostic performance study. Radiology. 2014;273(3):813-20.PubMed
35.
Zurück zum Zitat Zarzour JG, Milner D, Valentin R, et al. Quantitative iodine content threshold for discrimination of renal cell carcinomas using rapid kV-switching dual-energy CT. Abdom Radiol (NY). 2017;42(3):727-34.PubMed Zarzour JG, Milner D, Valentin R, et al. Quantitative iodine content threshold for discrimination of renal cell carcinomas using rapid kV-switching dual-energy CT. Abdom Radiol (NY). 2017;42(3):727-34.PubMed
36.
Zurück zum Zitat Bellini D, Panvini N, Laghi A, et al. Systematic Review and Meta-Analysis Investigating the Diagnostic Yield of Dual-Energy CT for Renal Mass Assessment. AJR Am J Roentgenol. 2019:1-10. Bellini D, Panvini N, Laghi A, et al. Systematic Review and Meta-Analysis Investigating the Diagnostic Yield of Dual-Energy CT for Renal Mass Assessment. AJR Am J Roentgenol. 2019:1-10.
37.
Zurück zum Zitat Weinstein MC, Siegel JE, Gold MR, Kamlet MS, Russell LB. Recommendations of the Panel on Cost-Effectiveness in Health and Medicine. JAMA. 1996;276(15):1253-8.PubMed Weinstein MC, Siegel JE, Gold MR, Kamlet MS, Russell LB. Recommendations of the Panel on Cost-Effectiveness in Health and Medicine. JAMA. 1996;276(15):1253-8.PubMed
38.
Zurück zum Zitat Health UDo, Services H. Cost-effectiveness in health and medicine: Report to the US Public Health Service by the Panel on cost-effectiveness in health and medicine. Cost-effectiveness in health and medicine: report to the US Public Health Service by the Panel on Cost-Effectiveness in Health and Medicine: US Department of Health and Human Services, 1996. Health UDo, Services H. Cost-effectiveness in health and medicine: Report to the US Public Health Service by the Panel on cost-effectiveness in health and medicine. Cost-effectiveness in health and medicine: report to the US Public Health Service by the Panel on Cost-Effectiveness in Health and Medicine: US Department of Health and Human Services, 1996.
39.
Zurück zum Zitat Sanders GD, Neumann PJ, Basu A, et al. Recommendations for Conduct, Methodological Practices, and Reporting of Cost-effectiveness Analyses: Second Panel on Cost-Effectiveness in Health and Medicine. JAMA. 2016;316(10):1093-103.PubMed Sanders GD, Neumann PJ, Basu A, et al. Recommendations for Conduct, Methodological Practices, and Reporting of Cost-effectiveness Analyses: Second Panel on Cost-Effectiveness in Health and Medicine. JAMA. 2016;316(10):1093-103.PubMed
40.
Zurück zum Zitat Kang SK, Huang WC, Pandharipande PV, Chandarana H. Solid renal masses: what the numbers tell us. AJR Am J Roentgenol. 2014;202(6):1196-206.PubMedPubMedCentral Kang SK, Huang WC, Pandharipande PV, Chandarana H. Solid renal masses: what the numbers tell us. AJR Am J Roentgenol. 2014;202(6):1196-206.PubMedPubMedCentral
41.
Zurück zum Zitat Heilbrun ME, Remer EM, Casalino DD, et al. ACR Appropriateness Criteria indeterminate renal mass. J Am Coll Radiol. 2015;12(4):333-41.PubMed Heilbrun ME, Remer EM, Casalino DD, et al. ACR Appropriateness Criteria indeterminate renal mass. J Am Coll Radiol. 2015;12(4):333-41.PubMed
42.
Zurück zum Zitat Sun M, Abdollah F, Bianchi M, et al. Treatment management of small renal masses in the 21st century: a paradigm shift. Ann Surg Oncol. 2012;19(7):2380-7.PubMed Sun M, Abdollah F, Bianchi M, et al. Treatment management of small renal masses in the 21st century: a paradigm shift. Ann Surg Oncol. 2012;19(7):2380-7.PubMed
43.
Zurück zum Zitat Pandharipande PV, Gervais DA, Hartman RI, et al. Renal mass biopsy to guide treatment decisions for small incidental renal tumors: a cost-effectiveness analysis. Radiology. 2010;256(3):836-46.PubMedPubMedCentral Pandharipande PV, Gervais DA, Hartman RI, et al. Renal mass biopsy to guide treatment decisions for small incidental renal tumors: a cost-effectiveness analysis. Radiology. 2010;256(3):836-46.PubMedPubMedCentral
44.
Zurück zum Zitat Sonnenberg FA, Beck JR. Markov models in medical decision making: a practical guide. Med Decis Making. 1993;13(4):322-38.PubMed Sonnenberg FA, Beck JR. Markov models in medical decision making: a practical guide. Med Decis Making. 1993;13(4):322-38.PubMed
45.
Zurück zum Zitat SEER Incidence Data, 1975-2016. November 2018 ed: National Cancer Institute. SEER Incidence Data, 1975-2016. November 2018 ed: National Cancer Institute.
46.
Zurück zum Zitat Halpern EF, Pandharipande PV. Behind the Numbers: Sensitivity Analysis in Cost-Effectiveness Modeling. Radiology. 2017;284(2):310-2.PubMed Halpern EF, Pandharipande PV. Behind the Numbers: Sensitivity Analysis in Cost-Effectiveness Modeling. Radiology. 2017;284(2):310-2.PubMed
47.
Zurück zum Zitat Briggs AH, O’Brien BJ, Blackhouse G. Thinking outside the box: recent advances in the analysis and presentation of uncertainty in cost-effectiveness studies. Annu Rev Public Health. 2002;23:377-401.PubMed Briggs AH, O’Brien BJ, Blackhouse G. Thinking outside the box: recent advances in the analysis and presentation of uncertainty in cost-effectiveness studies. Annu Rev Public Health. 2002;23:377-401.PubMed
48.
Zurück zum Zitat Ho VB, Allen SF, Hood MN, Choyke PL. Renal masses: quantitative assessment of enhancement with dynamic MR imaging. Radiology. 2002;224(3):695-700.PubMed Ho VB, Allen SF, Hood MN, Choyke PL. Renal masses: quantitative assessment of enhancement with dynamic MR imaging. Radiology. 2002;224(3):695-700.PubMed
49.
Zurück zum Zitat Taouli B, Thakur RK, Mannelli L, et al. Renal lesions: characterization with diffusion-weighted imaging versus contrast-enhanced MR imaging. Radiology. 2009;251(2):398-407.PubMed Taouli B, Thakur RK, Mannelli L, et al. Renal lesions: characterization with diffusion-weighted imaging versus contrast-enhanced MR imaging. Radiology. 2009;251(2):398-407.PubMed
50.
Zurück zum Zitat Klinghoffer Z, Tarride JE, Novara G, et al. Cost-utility analysis of radical nephrectomy versus partial nephrectomy in the management of small renal masses: Adjusting for the burden of ensuing chronic kidney disease. Can Urol Assoc J. 2013;7(3-4):108-13.PubMedPubMedCentral Klinghoffer Z, Tarride JE, Novara G, et al. Cost-utility analysis of radical nephrectomy versus partial nephrectomy in the management of small renal masses: Adjusting for the burden of ensuing chronic kidney disease. Can Urol Assoc J. 2013;7(3-4):108-13.PubMedPubMedCentral
51.
Zurück zum Zitat Faubel S, Patel NU, Lockhart ME, Cadnapaphornchai MA. Renal relevant radiology: use of ultrasonography in patients with AKI. Clin J Am Soc Nephrol. 2014;9(2):382-94.PubMed Faubel S, Patel NU, Lockhart ME, Cadnapaphornchai MA. Renal relevant radiology: use of ultrasonography in patients with AKI. Clin J Am Soc Nephrol. 2014;9(2):382-94.PubMed
52.
Zurück zum Zitat Vogelzang NJ, Pal SK, Ghate SR, et al. Real-World Economic Outcomes During Time on Treatment Among Patients Who Initiated Sunitinib or Pazopanib as First Targeted Therapy for Advanced Renal Cell Carcinoma: A Retrospective Analysis of Medicare Claims Data. J Manag Care Spec Pharm. 2018;24(6):525-33.PubMed Vogelzang NJ, Pal SK, Ghate SR, et al. Real-World Economic Outcomes During Time on Treatment Among Patients Who Initiated Sunitinib or Pazopanib as First Targeted Therapy for Advanced Renal Cell Carcinoma: A Retrospective Analysis of Medicare Claims Data. J Manag Care Spec Pharm. 2018;24(6):525-33.PubMed
53.
Zurück zum Zitat Corwin MT, Hansra SS, Loehfelm TW, Lamba R, Fananapazir G. Prevalence of Solid Tumors in Incidentally Detected Homogeneous Renal Masses Measuring > 20 HU on Portal Venous Phase CT. AJR Am J Roentgenol. 2018;211(3):W173-W7.PubMed Corwin MT, Hansra SS, Loehfelm TW, Lamba R, Fananapazir G. Prevalence of Solid Tumors in Incidentally Detected Homogeneous Renal Masses Measuring > 20 HU on Portal Venous Phase CT. AJR Am J Roentgenol. 2018;211(3):W173-W7.PubMed
54.
Zurück zum Zitat Saad AM, Gad MM, Al-Husseini MJ, Ruhban IA, Sonbol MB, Ho TH. Trends in Renal-Cell Carcinoma Incidence and Mortality in the United States in the Last 2 Decades: A SEER-Based Study. Clin Genitourin Cancer. 2019;17(1):46-57 e5. Saad AM, Gad MM, Al-Husseini MJ, Ruhban IA, Sonbol MB, Ho TH. Trends in Renal-Cell Carcinoma Incidence and Mortality in the United States in the Last 2 Decades: A SEER-Based Study. Clin Genitourin Cancer. 2019;17(1):46-57 e5.
55.
Zurück zum Zitat Sun M, Thuret R, Abdollah F, et al. Age-adjusted incidence, mortality, and survival rates of stage-specific renal cell carcinoma in North America: a trend analysis. Eur Urol. 2011;59(1):135-41.PubMed Sun M, Thuret R, Abdollah F, et al. Age-adjusted incidence, mortality, and survival rates of stage-specific renal cell carcinoma in North America: a trend analysis. Eur Urol. 2011;59(1):135-41.PubMed
56.
Zurück zum Zitat Pandharipande PV, Gervais DA, Mueller PR, Hur C, Gazelle GS. Radiofrequency ablation versus nephron-sparing surgery for small unilateral renal cell carcinoma: cost-effectiveness analysis. Radiology. 2008;248(1):169-78.PubMedPubMedCentral Pandharipande PV, Gervais DA, Mueller PR, Hur C, Gazelle GS. Radiofrequency ablation versus nephron-sparing surgery for small unilateral renal cell carcinoma: cost-effectiveness analysis. Radiology. 2008;248(1):169-78.PubMedPubMedCentral
57.
Zurück zum Zitat Hoyle M, Green C, Thompson-Coon J, et al. Cost-effectiveness of sorafenib for second-line treatment of advanced renal cell carcinoma. Value Health. 2010;13(1):55-60.PubMed Hoyle M, Green C, Thompson-Coon J, et al. Cost-effectiveness of sorafenib for second-line treatment of advanced renal cell carcinoma. Value Health. 2010;13(1):55-60.PubMed
Metadaten
Titel
Cost-effectiveness of dual-energy CT versus multiphasic single-energy CT and MRI for characterization of incidental indeterminate renal lesions
verfasst von
Bhavik N. Patel
Artem T. Boltyenkov
Maria G. Martinez
Domenico Mastrodicasa
Daniele Marin
R. Brooke Jeffrey
Benjamin Chung
Pari Pandharipande
Avinash Kambadakone
Publikationsdatum
02.01.2020
Verlag
Springer US
Erschienen in
Abdominal Radiology / Ausgabe 6/2020
Print ISSN: 2366-004X
Elektronische ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-019-02380-x

Weitere Artikel der Ausgabe 6/2020

Abdominal Radiology 6/2020 Zur Ausgabe

Special Section: The pelvic floor

Fertility-related considerations in endometriosis

Kidneys, Ureters, Bladder, Retroperitoneum

Clinical and imaging features of IgG4-related kidney disease

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.